HomeMy WebLinkAbout06080101.24IN IL IK Id IE ID PLUMBING LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION - COLD WATER 1 RISER IDENTIFICATION - - HOT WATER D CAP ON LINE - - - HOT WATER RECIRCULATION 0 PIPE TURNED UP • COLD WATER (UNDERGROUND) -0 PIPE TURNED DOWN • • HOT WATER (UNDERGROUND) -- i BALANCING VALVE • • • HOT WATER RECIRCULATION (UNDERGROUND) FLOOR SERVICE BASIN BALL VALVE 1/2" — W — WASTE LINE (ABOVE FLOOR OR BELOW GROUND) pQ GATE VALVE -- - - V - - -- VENT PIPE (ABOVE OR BELOW FLOOR) P -7 CHECK VALVE D DRAIN LINE AS SHOWN GAS COCK FLOOR DRAIN MECHANICAL ROOM ---� CLEANOUT (ABOVE CEILING) JAS SHOWN PRESSURE REDUCING VALVE FLOOR SINK HALF GRATE ^ CLEANOUT AS SHOWN P -10 UNION IN PIPE 1/2" — v CLEANOUT (EXTERIOR) SHOCK ABSORBER — —R0 R.O. WATER P -12 ICE MAKER CONNECTION BOX — BICARB BICARB CONCENTRATE — P -13 — PRIMARY PRIMARY CONCENTRATE 1/2" 1-1/2" —SECONDARY— SECONDARY CONCENTRATE 1 to 1 — P -15 DISH WASHER CONNECTION — PLUMBING GENERAL NOTES I 1. CONTRACTOR IS RESPONSIBLE FOR CONNECTION OF HOT AND COLD WATER, AND WASTE AND VENT TO AND FROM ALL PLUMBING FIXTURES AND EQUIPMENT SHOWN ON ARCHITECTURAL DRAWINGS. REFER TO FIXTURE CONNECTION SCHEDULE FOR MINIMUM PIPE SIZES TO CLOSEST MAINS. 2. CONTRACTOR SHALL COORDINATE EQUIPMENT CONNECTIONS WITH EQUIPMENT DRAWINGS AND SUPPLIER. INSTALL EQUIPMENT AND MAKE FINAL CONNECTIONS FURNISHING: CUTOFF VALVES, P- TRAPS, P.R.V.'S AND PIPING AS REQUIRED. 3. CONTRACTOR SHALL FURNISH AND INSTALL SHOCK ABSORBERS ON ALL FLUSH VALVE FIXTURES AND ALL LINES SERVING QUICK CLOSING VALVES AS REQUIRED BY MANUFACTURERS RECOMMENDATIONS AND AS SHOWN ON DRAWINGS. 4. CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINES INVOLVED SO AS TO AVOID ANY PIPE ROUTING PROBLEMS. 5. ALL VENTS SHALL BE A MINIMUM OF 25' -0" AWAY FROM ALL FRESH AIR INTAKES ON A/C UNITS, OPERABLE WINDOWS, AND DOORS. 6. VENTS AND WASTE STACKS LESS THAN (3) INCHES SHALL NOT BE ROUTED THROUGH ROOF. PROVIDE INCREASES ON LINES BELOW ROOF SLAB. 7. FURNISH AND INSTALL DEEP SEAL P -TRAPS ON FLOOR DRAINS NOT EQUIPPED WITH AN AUTOMATIC TRAP PRIMER SYSTEM IN ALL AREAS SUBJECT TO VAPORIZING OF THE P -TRAP. 8. PROVIDE SHUT -OFF VALVES ON ALL HOT AND COLD WATER BRANCH LINES AT CONNECTION TO MAINS WHETHER SHOWN ON PLANS OR NOT. 9. ALL FIXTURES, EQUIPMENT AND PIPING SHOWN ON THESE DRAWINGS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND THEIR AMENDMENTS, AUTHORITIES HAVING JURISDICTION, AND THE OWNER'S INSURING AGENCY. 10. PROVIDE A MAXIMUM 6" DIRT LEG ON THE RO SYSTEM AT EACH DIALYSIS BOX CONNECTION. 11. PROVIDE 90' LONG SWEEP ELBOWS AT ALL CHANGES IN DIRECTION OF ALL DIALYSIS (TREATED WATER) PIPING. 12. WATER BOXES AND MAINTENANCE BOXES ARE OWNER PROVIDED AND INSTALLED BY CONTRACTOR. 13. CUTTING OF DIALYSIS LOOP PIPING WITH A HACKSAW SHALL NOT BE PERMITTED, USE ONLY TOOLS APPROVED BY THE PROJECT MANAGER WHEN CUTTING DIALYSIS LOOP PIPING. 14. INSTALL WATER HEATERS SO THAT TANK CLEANOUT HAND HOLE IS ACCESSIBLE TO MAINTENANCE PERSONNEL. PLUMBING DEMOLITION NOTES 1. CONTRACTOR SHALL REMOVE EXISTING SERVICES SUCH AS WATER, WASTE, AND VENT PIPING SERVING FIXTURES AND /OR CONNECTIONS TO EQUIPMENT WHICH IS TO BE REMOVED OR RELOCATED AS INDICATED AND SHOWN ON THE ARCHITECTURAL DRAWINGS. PERMANENTLY SEAL AND CAP SERVICES NEXT TO MAIN SERVICE LINES ABOVE CEILING, IN WALLS, OR BELOW FLOORS. EXISTING PLUMBING FIXTURES AND RELATED ITEMS WHICH ARE TO BE REMOVED, SHALL BE SUBMITTED TO THE OWNER. ITEMS THAT THE OWNER WISHES TO RETAIN SHALL BE DELIVERED TO STORAGE WHERE DIRECTED BY OWNER. ITEMS THAT THE OWNER DOES NOT WISH TO RETAIN SHALL BE LEGALLY DISPOSED OF. 2. THESE DRAWINGS WERE DERIVED FROM LIMITED FIELD OBSERVATIONS AND MAY NOT BE ALL INCLUSIVE OF THE CONDITIONS THAT EXIST. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS AND PIPE ROUTING PRIOR TO SUBMITTAL OF BID. 3. EXISTING FIXTURES, EQUIPMENT, SERVICES, AND CONNECTIONS THAT ARE SHOWN TO REMAIN AS IS THAT ARE DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED TO LIKE NEW CONDITION OR REPLACED AS REQUIRED TO PROVIDE ORIGINAL OPERATION. 4. PENETRATIONS THROUGH EXISTING WALLS AND FLOORS SHALL BE SLEEVED AND /OR PATCHED AS DIRECTED BY THE SPECIFICATIONS. 5. EXISTING PLUMBING SERVICES: WATER, WASTE, VENT, AND RAIN WATER LINES NOT SHOWN ON DRAWINGS SHALL REMAIN AS IS, UNLESS NOTED OTHERWISE. 6. EXISTING FIXTURES, EQUIPMENT CONNECTIONS AND SERVICE LINES SUCH AS: WATER, WASTE, VENT, AND RAIN WATER, SHALL BE FIELD VERIFIED FOR EXACT LOCATIONS, IF DEVIATIONS ARE FOUND, CONTRACTOR SHALL BRING THEM TO THE ARCHITECT'S ATTENTION FOR COORDINATION. SPRINKLER NOTE REWORK EXISTING SPRINKLER SYSTEM TO PROVIDE A COMPLETE 100% HYDRAULICALLY CALCULATED, AUTOMATIC WET PIPE SPRINKLER SYSTEM. AS SPECIFIED UNDER DIVISION 13915 OF THE SPECIFICATIONS, SERVING THE ENTIRE RENOVATED AREA, AND EXCLUDING NO SPACES. THE SYSTEM SHALL BE INSTALLED TO MEET INSURING AGENCY GUIDELINES, NFPA 13, THE REQUIREMENTS OF THESE DOCUMENTS, AND STATE AND LOCAL CODE REQUIREMENTS. SPRINKLER HEAD LAYOUT AND PIPE ROUTING SHALL BE BASED UPON NEW FLOOR PLAN. (EXISTING FIRE ALARM PANEL, PULL STATIONS, STANDPIPE, AND RELATED EQUIPMENT SHALL REMAIN.) PLUMBING FIXTURE CONNECTION SCHEDULE TYPE DESCRIPTION CW HW W P -1 WATER CLOSET— PUBLIC. BARRIER FREE —FLUSH TANK 1 — 4" P -2 LAVATORY WALL HUNG — BARRIER FREE 172"r 1 2 1-1/4" P -3 SINK 19 "x21 " S.S. SINGLE COMPARTMENT 1/ 2 1 2 1-1/2" P -4 SINK 19"x21"x10 -1 2" S.S. SINGLE COMPARTMENT 1/2" 1/2" 1 -1/2" P -5 FLOOR SERVICE BASIN 1/2" 1/2" 3" P -6 EMERGENCY EYEWASH 3/4" — 1 -1/2" P -7 FLOOR DRAIN GENERAL PURPOSE — — AS SHOWN P -8 FLOOR DRAIN MECHANICAL ROOM — — JAS SHOWN P -9 FLOOR SINK HALF GRATE — — AS SHOWN P -10 TRAP PRIMER 1/2" — — P -11 SHOCK ABSORBER — — — P -12 ICE MAKER CONNECTION BOX 1/2 — — P -13 SINK 19 "x21 " S.S. SINGLE COMPARTMENT— GARBAGE DISPOSAL 1/2" 1/2" 1-1/2" P -14 COMBINATION EMERGENCY SHOWER EYEWASH 1 to 1 — P -15 DISH WASHER CONNECTION — — — P -16 BED PAN WASHER WATER HEATER SCHEDULE SYSTEM TYPE REQ'D MFGR. M NOEL E.W.T L.W.T. ST (GALLONS) CAPACITY RECOVERY GA(CFH) D SIZE REMARKS RECIRC. B & G NBF- 10S /LW 2 10 FIELD SET TIMED BACK WASH W.C.O. PROVIDED BY OWNER INSTALLED BY CONTRACTOR 115/60/1 PROVIDE WITH UNION CONNECTIONS „ 78X H PROVIDE AMTROL #ST -12 -C HWRP HOT WATER RECIRC. PUMP I.E. INVERT ELEVATION TMV -2 1 LAWLER 86004 341 GPH 140' 105' THERM- X -TROL EXPANSION TANK WH -1 GAS 1 LOCHINVAR TNR300 -100 40' 140' M 0 100' AT 300 PROVIDE VERT. DIRECT VENTING Z I— LL_ 29„ D 4" AIR INLET - 4" VENT MIXING VALVE SCHEDULE SYSTEM NO; REQ D MFGR. MODEL NO. CW E.W.T. HW E.W.T. TW L.W.T. OUT ET FLOW GPM SYSTEM PRESS. DROP REMARKS TMV -1 HWRP -1 RECIRC. B & G NBF- 10S /LW 2 10 FIELD SET TIMED BACK WASH W.C.O. PROVIDED BY OWNER INSTALLED BY CONTRACTOR 115/60/1 PROVIDE WITH UNION CONNECTIONS F.E. FIRE EXTINGUISHER HWRP HOT WATER RECIRC. PUMP I.E. INVERT ELEVATION TMV -2 1 LAWLER 86004 40' 140' 105' 30 10 PSI 0 39 GPM VALVE #802 PUMP SCHEDULE SYSTEM TYPE MANUFACTURER MODEL NO. G.P.M HEAD FT. PUMP SUCTION FT. PUMP DISCHARGE FT. H.P. ELECTRICAL REMARKS HWRP -1 RECIRC. B & G NBF- 10S /LW 2 10 FIELD SET TIMED BACK WASH W.C.O. 55 W 115/60/1 PROVIDE WITH UNION CONNECTIONS F.E. FIRE EXTINGUISHER HWRP HOT WATER RECIRC. PUMP I.E. INVERT ELEVATION F.D. FLOOR DRAIN A.P. ACCESS PANEL P -1, ETC. WATER SOFTENER SCHEDULE SYSTEM MANUFACTURER MODEL NO. SERVICE FLOW RATE (G.P.M.) MAX. GRAINS SOFTENER TANK SIZE BRINE TANK SIZE SERVICE PIPE SIZE REMARKS DOMESTIC HW CULLIGAN HC- 120 -1.5T 29 GPM 0 15 PSI LOSS 120 16" DIA 24" DIA 1 -1/2" FIELD SET TIMED BACK WASH W.C.O. WALL CLEANOUT MW MAKE -UP WATER F.E. FIRE EXTINGUISHER HWRP HOT WATER RECIRC. PUMP I.E. PLUMBING ABBREVIATIONS CW COLD WATER RPBP REDUCED PRESSURE BACKFLOW PRVENTER HW HOT WATER P.R.V. PRESSURE REDUCING VALVE HWR HOT WATER RECIRC E.C.O. EXTERIOR CLEANOUT VTR VENT THRU ROOF C.O. CLEANOUT W WASTE INTERIOR /UNDERGROUND W.C.O. WALL CLEANOUT MW MAKE -UP WATER F.E. FIRE EXTINGUISHER HWRP HOT WATER RECIRC. PUMP I.E. INVERT ELEVATION F.D. FLOOR DRAIN A.P. ACCESS PANEL P -1, ETC. FIXTURE IDENTIFICATION A.F.F. ABOVE FINISHED FLOOR F.S. FLOOR SINK A.F.G. ABOVE FINISHED GRADE =T- T- M PLUMBING INDEX SHEET NO. SHEET TITLE FILE NAME PO.00 PLUMBING LEGENDS /SCHEDULES AND NOTES P000_SCHED IP200—UG P2.00 PLUMBING UNDERGROUND C:) P2.01 PLUMBING FLOOR PLAN P201—PIPING P3.01 PLUMBING DIALYSIS PIPING PLAN P301— DIALYSIS P6.01 PLUMBING DETAILS P601— DETAILS P6.02 PLUMBING DETAILS P602— DETAILS C) M ~ 00 2214 METROCENTER BLVD. SUITE 128 NASHVILLE, TN 37228 OFFICE 615.256.7038 FAX 615.256.7132 J 3 0 w w O a_ M t O ti p 00 CN 00 Z C:) N Z C) M ~ 00 Q Op C.0 '> L0 Lo =T- T- M CUCflCO v— Z I— LL_ U z U J Q 8 WE LJ Q z Q z J w 12 ry Q U z w U O z O_ F- U D ry Cn z O U W LLJ rM ��..1 ry z O U f— C!) z O U i AWN: LKK JJECT ARCHITECT: SPP IPROJECT MANAGER: LKK SIONS: )B# 05098 LE: (DATE: JULY 21, 2006 1 I NO. PF-10000001fA STRTE i ::B Q' t�•�� `!MDIA�•' � Plumbing Schedules P0.00 ©I