Loading...
HomeMy WebLinkAbout06080101.5J F 5 Aildl SIM. WALL. LEGEND EXISTING 3 -5/8" MTL. STUD W1 5/S" GYP. EITHER SIDE, UNRATED PARTITION - NEW ro" MTL. STUD W1 5/8" GYP. EITHER SIDE, UNRATED PARTITION - NEW A" n FLOOR PLAN KFY NOTE5: 01 EXISTING: ROOF DRAIN TO REMAIN. FURR -OUT WALL WITH 2 1/2" METAL STUD AND TYPE 'X' GYPSUM BOARD (TIGHT TO COLUMN). 02 WRAP COLUMN TIGHT AT STAFF LOUNGE /CONFERENCE ROOM. HOWEVER, ALLOW SPACE FOR BLOCKING AND ELECTRICAL DEVICES FOR TIME CLOCK, COORDINATE WITH ELECTRICAL. 03 INSTALL NEW 5/8" GYP. BD. OVER 2 1/2" MTL STUD FURR -OUT AT EXISTING BLOCK WALL. CONTRACTOR TO VERIFY SPECIFIED ELECTRICAL BOXES TO FIT IN 2 1/2" FURR -OUT (REF PLAN). GYP. BD. NOT REQUIRED BEHIND DIALYSIS CHASE. 04 CONTRACTOR TO PROVIDE STRUCTURAL ENGINEER FOR ADDED SUPPORT AT EXISTING BAR JOIST STRUCTURE TO ACCOMMODATE: NEW ROOF TOP UNIT, NEW SCREEN AND FOR SUSPENDED TRANSFORMER SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL. 05 CONTRACTOR TO VERIFY IF EXISTING BATT INSULATION IS INSTALLED A l ALL EXISTING TENANT PERIMETER WALLS. REF. ALT 02, SHEET A102. 06 CONTRACTOR TO PROVIDE NEW TYPE 'X' GYP. BD, AT INSIDE PERIMETER WALL THROUGHOUT TENANT SPACE. 07 CONTRACTOR TO PROVIDE NEW SCREEN WALL FOR NEW RTU AT ROOF. NEW SCREEN WALL SHALL MATCH EXISTING SCREEN MATERIAL, COLOR AND HEIGHT ON ROOF. STRUCTURAL SUPPORT TO BE REINFORCED, REF NOTE 4, SHEET A102. pg CONTRACTOR TO PROVIDE FOUR (4) MOISTURE TESTS OF EXISTING CONCRETE SLAB. TESTS SHALL BE LOCATED AT THE FOLLOWING AREAS: TREATMENT AREA STATION 5. STATION 10, DIET SOCIAL OFFICE AND WATER TREATMENT ROOM. TENANT SPACE BEING TESTED SHALL BE FULLY CONDITIONED 48 HOURS (MINIMUM) PRIOR TO ANY TESTING BEING PERFORMED. TEST RESULTS TO BE SENT TO ARCHITECT FOR APPROVAL OF EXISTING SLAB CONDITIONS PRIOR TO INSTALLING NEW FLOOR FINISHES. Og EXTEND EXISTING TENANT DEMISING WALL TO EXTERIOR WALL ABOVE CEILING FOR COMPLETE TENANT SEPARATION. INSTALL BATT INSULATION THROUGHOUT. 10 5/8" OSB OVER METAL STUD AT INSIDE PERIMETER OF WATER TREATMENT. 11 INSTALL NEW FAKE WINDOW MULLION AS NEEDED AT NEW WALL INTERSECTION AT EXISTING GLASS WINDOW. MULLION TO MATCH EXISTING WINDOW FRAME COLOR USE EXPANDABLE CAULK AT GLASS INTERSECTION WITH FAKE MULLION, TYP. AT ALL INTERSECTIONS. 12 INSTALL 5/8" DENS ARMOR PLUS WALL BOARD AT THE FOLLOWING LOCATIONS: A. BEHIND ALL WALL HUNG SINK LOCATIONS. B. JANITOR - ALL WALLS. C. TOILET ROOMS - ALL WALLS. D. WATER TREATMENT ROOM - (REF SHEET A4.01 FOR FRP AND GYP BD LOCATIONS IN THIS ROOM). E. BEHIND DIALYSIS CHASE 48" A.F.F. - TYPE 'X' GYP. BD. ABOVE. F. TEC R OM - ALL WALLS (REF AUTO DOOR WITH PUSH PAD BUTTON A. SEE S A1-02 FOR PUSH BUTTON LOCATIONS, PROVIDE POWER TO DEVICE. O14 DISCONNECT SWITCH TO BE PAINTED TO MATCH EXISTING= BUILDING WALL COLOR REF. ELECTRICAL FOR ADDITIONAL 15 INSTALL NEW 6' -O" HIGH WOOD "SHADOWBOX" FENCING (FOUR SIDES) WITH PAIR V -0" GATE OVER PIER FOOTINGS. MAINTAIN INSIDE CLEARANCE AS NOTED ON PLAN FOR FUTURE EQUIPMENT. STAIN COLOR TO BE DETERMINED BY BUILDING OWNER SUBMIT STANDARD RANGE OF COLORS TO ARCHITECT FOR SELECTIONS. ALTERNATE &: ALT. fl: CONTRACTOR TO INCLUDE ALTERNATE PRICE TO DEMOLISH EXISTING DOOR 118 AND REPLACE WITH NEW V -ro" ALUMINUM STOREFRONT DOOR, PANIC HARDWARE, AUTO - OPENER AND PUSH BUTTON. PRICE SHALL INCLUDE DEMOLITION OF EXISTING EXTERIOR WALL FOR LARGER OPENING AND NEW LINTEL ABOVE. NEW BRICK INSTALLATION TO MATCH EXISTING SIZE, TEXTURE AND COLOR ALT. *2: CONTRACTOR TO INCLUDE ALTERNATE PRICE TO ADD 3" BATT INSULATION INSIDE EXISTING INTERIOR DEMISING WALLS. CONTRACTOR TO VERIFY EXISTING CONDITIONS AND VERIFY IF ANY EXISTING INSULATION IS PRESENT. INFORM ARCHITECT ON FINDINGS. ALT. 03: CONTRACTOR TO INCLUDE ALTERNATE PRICE TO INSTALL NEW CARPET AND PAD AT EXISTING CORRIDOR AT CONSTRUCTION PATH AREA ONLY (MATCH EXISTING PAD AND CARPET STYLE /COLOR). ALT. 04 CONTRACTOR TO INCLUDE ALTERNATE PRICE TO ADHERE I" RIGID INSULATION WITH TAPED JOINTS TO FACE OF EXISTING BLOCK WALL. CONTRACTOR SHALL CONFIRM IF EXISTING BLOCK CELLS ARE INSULATED AND INFORM ARCHITECT ON FINDINGS. REF. "KEY NOTE" 1, SHEET D101. ALT. 05 CONTRACTOR TO INCLUDE ALTERNATE PRICE FOR NEW EXTERIOR (5' -0" WIDE) CONCRETE SIDEWALK FROM STORAGE DOOR TO INTERSECTION OF EXISTING SIDE WALK AT FRONT OF BUILDING AND TO NEW GENERATOR PAD. INCLUDE EXCAVATION OF EXISTING GRADE AND PREP TO ACCOMMODATE NEW SIDE WALK. REF "KEY NOTE" 13, SHEET D101. ALT. % INSTALL 4" CONCRETE PAD FOR (FUTURE) MOBILE GENERATOR AS INDICATED ON PLAN. CONTRACTOR TO FIELD VERIFY LOCATION WITH TENANT OWNER AND BUILDING OWNER PRIOR TO STARTING CONSTRUTION. CONCRETE PAD TO BE LOCATED 25' -0" MINIMUM FROM ANY OPERABLE WINDOW OR DOOR CONTACT ARCHITECT SHALL THE LOCATION OF THE GENERATOR PAD BE CHANGED FOR HIS RECORDS. IN PAF ,, NOTED FLOOR PLAN z J a Z w w W F-- W ry D U W F— U ry Q Z U z Z 1-i Lu }- lu U \ �- l� z Hi 0 0- U U DRAWN: LKK PROJECT ARCHITECT: SPP PROJECT MANAGER LKK REVISIONS: 1 ADD NO 01/01 -21 -06 2 ADD NO. 03 / OS -16 -04 JOB" 05098 FILE: DATE. JULY 21, 2006 1,02 NOTED FLOOR PLAN F CD r 0O :E: co 0 N c•- 00 N (:I) t-- 00 d- Z3 co N O7 co > 00 co o0 co Lo Lo M m CS0 1--- co " W ry D U W F— U ry Q Z U z Z 1-i Lu }- lu U \ �- l� z Hi 0 0- U U DRAWN: LKK PROJECT ARCHITECT: SPP PROJECT MANAGER LKK REVISIONS: 1 ADD NO 01/01 -21 -06 2 ADD NO. 03 / OS -16 -04 JOB" 05098 FILE: DATE. JULY 21, 2006 1,02 NOTED FLOOR PLAN F