HomeMy WebLinkAbout06110089.2C I' ,Ali P1 TI FOOTING o MARK O� (W x D) REINF. WF1 2' -6" x 2' -6" o CD WF2 1' -6" r-L II 2 — #5 CONT. BOT fT 1' -3" U #5 E. W. BOT F3 5' -3" x 5' -3" x 0 M #5 E. W. BOT C 5-3" I 2' -6" 5 — #5 E. W. BOT F5 t CD 2' -6" o — #5 E. W. BOT co ANCHOR AT GYP. BOARD SHEARWALL PER DETAIL SHEET S2.4 co 0 M Z cQ 0 CD F CD a U ri ;r. P O I 0 N z O I 0 o LO N N �*/i1111 JI I _ I _ I I I 9" • 1 WF1 19' -3" WALL FOOTING SCHEDULE MARK SIZE (W x D) REINF. WF1 2' -6" x 2' -6" x 8' -9" x 3 — #5 CONT. BOT WF2 1' -6" x 2' -6" F2 2 — #5 CONT. BOT COLUMN FOOTING SCHEDULE MARK SIZE NOTES: REINF. F1 8' -9" x 8' -9" x 1' -3" 8 — #6 E. W. BOT F2 7' -3" x 7' -3" x 1' -3" 8 — #5 E. W. BOT F3 5' -3" x 5' -3" x V -0" 5 — #5 E. W. BOT F4 5-3" x 5' -3" x 2' -6" 5 — #5 E. W. BOT F5 4' -0" x 4' -0" x 2' -6" 4 — #5 E. W. BOT 20' -0" 100' -0" 2 i I F2.1 1'-3 9 " 16, -0" _ 1 20' -0 -0" 0 4 FOUNDATION PLAN Il e� 20' -0" NOTE: ALL EXTERIOR DIMENSIONS SHOWN ARE TO OUTSIDE FACE OF C.M.U. 19' -3" 113 1 9' -0" 618 East Market Street I Indianapolis, Indiana 46202 ph 317/264.8162 fx 317/264.8165 a x i s a r c h. c o m Scope Drawings These drawings indicate the general scope of the project in terms of orchitedurol design concept, the dimensions of the building, the major orchitedural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. DRAWN by CIS CHECKED by CPS DATE issued 17 OCT. 2006 REVISIONS SCHNEIDER CORP. ASHTON FRITZ 8901 OTIS AVENUE INDIANAPOLIS, IN 46216 (317) 826 -7100 (317) 826 -7200 ( STRUCTURAL DESIGN, INC. CHUCK SCHAEFER 337 MAIN STREET BEECH GROVE, IN 46107 (317) 822.0204 (317) 822.0206 VECTOR CONSULTING BEN DEREMIAH 212 W. 10TH ST., SUITE D -395 INDIANAPOLIS, IN 46202 (317) 632.4444 (317) 632.4960 W z Z W �z a o LU LU � O ,v VLu�= -y W LU LU LU ix ~ � V H No. * 870367 i �• STATE OF Ii�'�iC •• .!ND IAN?;.••' • •����� ONiii����`�� State Design Release Set FOUNDATION PLAN SCALE AS NOTED Ln F1.1 N NOTES: 1). TOP OF SLAB EL. 100' -0" U.N.O. 2). TOP OF EXT. FOOTING ELEVATION 99' -4" U.N.O. 3). TOP OF INT. FOOTING ELEVATION 99' -4" U.N.O. 4). SEE ARCH. DWGS. FOR LOCATION OF DOOR OPENINGS AND SIZES. 5). • DENOTES SIMPSON HDQ8 TIE DOWN ANCHOR AT PLYWOOD SHEARWALL PER DETAIL SHEET S2.4 6). # DENOTES SIMPSON HTT22 TIE DOWN ANCHOR AT GYP. BOARD SHEARWALL PER DETAIL SHEET S2.4 20' -0" NOTE: ALL EXTERIOR DIMENSIONS SHOWN ARE TO OUTSIDE FACE OF C.M.U. 19' -3" 113 1 9' -0" 618 East Market Street I Indianapolis, Indiana 46202 ph 317/264.8162 fx 317/264.8165 a x i s a r c h. c o m Scope Drawings These drawings indicate the general scope of the project in terms of orchitedurol design concept, the dimensions of the building, the major orchitedural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. DRAWN by CIS CHECKED by CPS DATE issued 17 OCT. 2006 REVISIONS SCHNEIDER CORP. ASHTON FRITZ 8901 OTIS AVENUE INDIANAPOLIS, IN 46216 (317) 826 -7100 (317) 826 -7200 ( STRUCTURAL DESIGN, INC. CHUCK SCHAEFER 337 MAIN STREET BEECH GROVE, IN 46107 (317) 822.0204 (317) 822.0206 VECTOR CONSULTING BEN DEREMIAH 212 W. 10TH ST., SUITE D -395 INDIANAPOLIS, IN 46202 (317) 632.4444 (317) 632.4960 W z Z W �z a o LU LU � O ,v VLu�= -y W LU LU LU ix ~ � V H No. * 870367 i �• STATE OF Ii�'�iC •• .!ND IAN?;.••' • •����� ONiii����`�� State Design Release Set FOUNDATION PLAN SCALE AS NOTED Ln F1.1 N