About
06110089.31
HVAC SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES ABBREVIATIONS ABBREVIATIONS ACC AIR COOLED CONDENSER LID LINEAR SLOT SUPPLY AIR DIFFUSER ACCU AIR COOLED CONDENSING UNIT LF LINEAR FEET ACHP AIR COOLED HEAT PUMP LR LINEAR SLOT RETURN AIR DIFFUSER AFF ABOVE FINISHED FLOOR LVR LOUVER AHU AIR HANDLING UNIT LWT LEAVING WATER TEMPERATURE APPROX APPROXIMATELY MAT MIXED AIR TEMPERATURE ARCH ARCHITECT MAU MAKEUP AIR UNIT AS AIR SEPARATOR MAX MAXIMUM ATM ATMOSPHERIC MBH 1000 BTU PER HOUR B BOILER MC MECHANICAL CONTRACTOR BCU BLOWER COIL UNIT MCA MINIMUM CIRCUIT AMPACITY BDD BACK DRAFT DAMPER MECH MECHANICAL BHP BRAKE HORSEPOWER MFR MANUFACTURER BLDG BUILDING MIN MINIMUM BOD BOTTOM OF DUCT MISC MISCELLANEOUS BTU BRITISH THERMAL UNIT MT MOUNT BTUH BTU PER HOUR N/A NOT APPLICABLE BTM BOTTOM NC NOISE CRITERIA °C DEGREES CELSIUS NG NATURAL GAS CEIL CEILING NPSH NET POSITIVE SUCTION HEAD CFM CUBIC FEET PER MINUTE OA OUTDOOR AIR CH CHILLER OAT OUTDOOR AIR TEMPERATURE CO CLEAN OUT P PUMP COP COEFFICIENT OF PERFORMANCE PD PRESSURE DROP CRAC COMPUTER ROOM AIR CONDITIONER PH PHASE CT COOLING TOWER PSI POUNDS PER SQUARE INCH CUH CABINET UNIT HEATER PSIA POUNDS PER SQUARE INCH ABSOLUTE CW COLD WATER PSIG POUNDS PER SQUARE INCH GAGE DB DRY BULB PRIES PRESSURE DIA OR 0 DIAMETER PTAC PACKAGED TERMINAL AIR CONDITIONER DWG DRAWING PTHP PACKAGED TERMINAL HEAT PUMP DX DIRECT EXPANSION PWR POWER EAT ENTERING AIR TEMPERATURE RA RETURN AIR EBB ELECTRIC BASEBOARD RAT RETURN AIR TEMPERATURE EC ELECTRICAL CONTRACTOR RAC ROOM AIR CONDITIONER EDH ELECTRIC DUCT HEATER RCP RADIANT CEILING PANEL EER ENERGY EFFICIENCY RATION RD ROUND SUPPLY AIR DIFFUSER EF EXHAUST FAN RG RETURN AIR GRILLE EFF EFFICIENCY RH RELIEF HOOD EG EXHAUST AIR GRILLE RHC REHEAT COIL EL ELEVATION RPM REVOLUTIONS PER MINUTE ELEC ELECTRIC RTU ROOFTOP UNIT ENT ENTERING SA SUPPLY AIR EQUIP EQUIPMENT SAN SANITARY ESP EXTERNAL STATIC PRESSURE SAT SUPPLY AIR TEMPERATURE ET EXPANSION TANK SO SQUARE SUPPLY AIR DIFFUSER EWH ELECTRIC WALL HEATER SENS SENSIBLE HEAT EWT ENTERING WATER TEMPERATURE SF SUPPLY FAN EX EXISTING SG SUPPLY AIR GRILLE EXH EXHAUST SPEC SPECIFICATION F FURNACE SQFT SQUARE FEET of DEGREES FAHRENHEIT STD STANDARD FCU FAN COIL UNIT TCC TEMPERATURE CONTROL CONTRACTOR FD FIRE DAMPER/FLOOR DRAIN TEMP TEMPERATURE FOB FLAT ON BOTTOM TO TEMPERATURE DIFFERENCE FOT FLAT ON TOP TOD TOP OF DUCT FPM FEET PER MINUTE TSP TOTAL STATIC PRESSURE FPVAV FAN - POWERED VAV BOX TSTAT THERMOSTAT FTR FIN TUBE RADIATION TOT TOTAL HEAT GAL GALLONS TYP TYPICAL GALV GALVANIZED UH UNIT HEATER GC GENERAL CONTRACTOR UR URINAL GFI GROUND FAULT INTERRUPTER UV UNIT VENTILATOR GPH GALLONS PER HOUR V VOLT GPM GALLONS PER MINUTE VAV VARIABLE AIR VOLUME GSHP GROUND SOURCE HEAT PUMP VD VOLUME DAMPER HB HOSE BIB VEL VELOCITY HOA HAND - OFF - AUTOMATIC VERT VERTICAL HP HORSEPOWER VFD VARIABLE FREQUENCY DRIVE HTG HVAC HEATING HEATING VENTILATING AND AIR CONDITIONING VOL VPAC VOLUME VERTICAL PACKAGED AIR CONDITIONER HVU HEATING AND VENTILATING UNIT VTR VENT THROUGH ROOF HW HOT WATER VVT VARIABLE VOLUME AND TEMPERATURE HX HEAT EXCHANGER W/ WITH HZ HERTZ WB WET BULB IH INTAKE HOOD WC WATER CLOSET IN INCH WG WATER GAUGE INCL INCLUDING WH WALL HYDRANT INSUL INSULATION WSHP WATER SOURCE HEAT PUMP KW KILOWATT WT WEIGHT KWH KILOWATT HOUR WTR WATER LAT LEAVING AIR TEMPERATURE WPD WATER PRESSURE DROP LAV LAVATORY XFMR TRANSFORMER LB POUND YCO YARD CLEAN OUT r-r CD a CT M r--1. CD c. CD CD CA's CWR CS CR HWS HAIR HCS HCR HPWS HPWR HPS MPS LPS HPC MPC LPC PC CD D MU AN FOD FOS FOR FOV RL RS RD HGB CPR G PIPING LEGEND CHILLED WATER SUPPLY CHILLED WATER RETURN CONDENSER WATER SUPPLY CONDENSER WATER RETURN HEATING WATER SUPPLY HEATING WATER RETURN HEATING /CHILLED WATER SUPPLY HEATING /CHILLED WATER RETURN HEAT PUMP WATER SUPPLY HEAT PUMP WATER RETURN HIGH PRESSURE STEAM MEDIUM PRESSURE STEAM LOW PRESSURE STEAM HIGH PRESSURE CONDENSATE RETURN MEDIUM PRESSURE CONDENSATE RETURN LOW PRESSURE CONDENSATE RETURN PUMPED CONDENSATE CONDENSATE DRAIN DRAIN MAKEUP WATER ATMOSPHERIC VENT FUEL OIL DISCHARGE FUEL OIL SUCTION FUEL OIL RETURN FUEL OIL VENT REFRIGERANT LIQUID REFRIGERANT SUCTION REFRIGERANT DISCHARGE HOT GAS BYPASS CHILLER PRESSURE RELIEF DISCHARGE NATURAL GAS DIRECTION OF FLOW DIRECTION OF PITCH EXISTING PIPE PIPE TO BE REMOVED DUCTWORK SYMBOLS O RTU -1 O FCU -1 © AHU -1 S2 -200 AA—* I pro `D PIPING SYMBOLS r r rrr CAP CD I� CLEAN OUT N co DROP REDUCER ^ RISE TEE - BOTTOM CONNECTION TEE - SIDE CONNECTION f f TEE - TOP CONNECTION I I 2 -WAY CONTROL VALVE 3 -WAY CONTROL VALVE AIR VENT - AUTOMATIC AIR VENT - MANUAL BALL VALVE -� rF-- BUTTERFLY VALVE -i CHECK VALVE -+<>- FLOW CONTROL VALVE - AUTOMATIC FLOW CONTROL VALVE - MANUAL GATE VALVE P PRESSURE GAUGE PRESSURE REDUCING VALVE P/T PLUG RELIEF VALVE 444"' STRAINER W/ BLOW DOWN VALVE THERMOMETER UNION THERMOSTAT /SENSOR WITH CONTROLLED DEVICE TAG RELATIVE HUMIDITY SENSOR WITH CONTROLLED DEVICE TAG CO2 SENSOR WITH SYSTEM DEVICE TAG DIFFUSER/GRILLE TAG SHOWING DEVICE TYPE AND CFM AIRFLOW DIRECTION MANUAL VOLUME DAMPER MOTORIZED DAMPER FIRE DAMPER SMOKE DAMPER COMBINATION FIRE AND SMOKE DAMPER ROUND FLEXIBLE DUCTWORK DUCT SIZE (36" ROUND SHOWN); 360 /36/206 DENOTES 36 "x20" FLAT OVAL BOD= 9' -10" BOTTOM OF DUCT ELEVATION ABOVE FINISHED FLOOR ELBOW WITH TURNING VANES ACCESS DOOR AD DUCT SIZE (36 "x20" RECTANGULAR, FIRST DIMENSION LISTED IS DIMENSION SHOWN IN VIEW) 36/20 LINED DUCT INTERNALLY LINED WITH INSULATION (DUCT DIMENSIONS SHOWN ARE OUTSIDE DIMENSIONS) SUPPLY DUCT UP SUPPLY DUCT DOWN RETURN /EXHAUST DUCT UP RETURN /EXHAUST DUCT DOWN DRAWING SYMBOLS O 2 H401 2 H401 CONNECT TO EXISTING DRAWING REVISION NUMBER PLAN NOTE NUMBER SECTION NUMBER WITH SHEET REFERENCE DETAIL NUMBER WITH SHEET REFERENCE GENERAL HVAC NOTES 1. ALL WORK SHALL COMPLY WITH THE MOST RECENT FEDERAL, STATE, AND LOCAL CODES. 2. DRAWINGS ARE SCHEMATIC IN NATURE AND SHOW GENERAL AREAS FOR PIPING AND DUCTWORK ROUTING. COORDINATE PIPING AND DUCTWORK WITH ALL OTHER TRADES (FIRE PROTECTION, PLUMBING, STRUCTURAL, ELECTRICAL, ETC.) BEFORE FABRICATION. DUCTWORK ELEVATIONS SHOWN ON DRAWINGS ARE FOR REFERENCE ONLY, AND SHALL BE COORDINATED WITH OTHER TRADES BEFORE FABRICATION. 3. COORDINATE ALL OPENINGS IN ROOF, FLOORS, OR WALLS WITH GENERAL CONTRACTOR AND STRUCTURAL CONTRACTOR PRIOR TO ANY WORK. 4. ANY CONFLICT OR DISCREPANCY BETWEEN DRAWINGS AND SPECIFICATIONS SHALL DEFAULT TO THE INFORMATION ON THE DRAWINGS. 5. EQUIPMENT AND MANUFACTURERS SCHEDULED ARE INTENDED TO SHOW A MINIMUM STANDARD OF QUALITY, AND ARE NOT INTENDED TO LIMIT COMPETITION. REFERENCE THE SPECIFICATIONS FOR OTHER APPROVED MANUFACTURERS. IF THE CONTRACTOR PROVIDES EQUIPMENT OTHER THAN BY THE MANUFACTURER SHOWN ON THE DRAWINGS, THEN IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSURE THAT THE EQUIPMENT FITS IN THE DELEGATED SPACE (INCLUDING ANY REQUIRED CLEARANCES) AND TO PROVIDE ANY ADDITIONAL WORK OR ACCESSORIES RESULTING FROM THE SUBSTITUTED EQUIPMENT. 618 East Market Street Indianapolis, Indiana 46202 ph 317/264.8162 fx 317/264.8165 91 a x is a r c h c o m Scope Drawings These drawings indicate the general scope of the project in terms of orchitecturol design concept, the dimensions of the building, As major areh lecturol elements and the type of structural, mechanical and electrical systems The drawings do not necessonly indicate or describe all work required for full performance and completion of the requirements of the connaA On the basis of the general scope indicated or described, the trade contractors shall furnish of hems required for the proper execution and completion of the work DRAWN by DES CHECKED by WRS DATE issued 17 OCT 2006 REVISIONS THE SCHNEIDER CORP. ASHTON FRITZ 8901 OTIS AVENUE INDIANAPOLIS, IN 46216 (317) 826 -7100 (317) 826 -7200 STRUCTURAL DESIGN, INC. ' CHUCK SCHAEFER 337 MAIN STREET BEECH GROVE, IN 46107 (317) 822.0204 (317) 822.0206 I VECTOR CONSULTING BEN DEREMIAH 212 W. 10TH ST., SUITE D -395 INDIANAPOLIS, IN 46202 (317) 632.4444 (317) 632.4960 W I0 Z) Z IZ w -U Q CN � M LLI Z W O - (D -'O I � LU Q O C U U .� C U Q — W W- — LU a� I�Nw E W r-- 0 W U Ia � IN t 1Dl l l l fs No. ° 10200105 •= ��• STATE OF \� 0% � � AfDIAtk �4lNA1�0���� HVAC LEGEND SCALE AS NOTED I HO. I 0