HomeMy WebLinkAbout06110089.32D C B A a 07 I< M Cn r-+ (D N M cQ CD CD i i' i MECH. ROOM 103 7. � f E1 -150 fV N MEDIUM PRESSURE SUPPLY DUCT FOR FUTURE TENANT FINISH (TYP) 6 ( _ C OPEN 80/14 SCREENED OFFICE 110 24/12 11 16/12 18/18 UP U �I - 14/4 [ I 14/12 - WOMENA 104 L, D2 -150 F-1 -150 PL E1-300 44/12 - t' El VAV -2 12/8 R2 VAV TRANSFER DUCT N � j STAIR 21 ' N II ST -2. r OPEN OFFICE 109 �I i RETURN OPENING ABOVE CEILING LINE 16/12` M ........... .... .. ` E1 -150 MEN 60/14 UP I D2 -150 10 a 1131 -150 62 -150 ! 8P1 120 CORRIDOR 2 ......................... 102 —U — -- VAv -1 T 24/12 16/12 3 120 _120 t,9 VAV -1 N S 1- 250 - - — TYP OF ECH -1 VU C 100 3.2' 3.8 ; FIRST FLOOR HVAC PLAN SCALE: 1/8" = V -0" 16/12 OPEN MEDIUM PRESSURE OFFICE SUPPLY DUCT FOR FUTURE TENANT 108 FINISH (TYP) STAIR 1 i �ir ? ' EWH -1 1 618 East Market Street I Indianapolis, Indiana 46202 ph 317/264.8162 fx 317/264.8165 a xi s a r c h. c o m GENERAL NOTES: 1. ALL SUPPLY DUCTWORK UPSTREAM OF VAV BOXES SHALL BE 4" PRESSURE CLASS. 2. ALL SUPPLY DUCTWORK DOWNSTREAM OF VAV BOXES, RETURN DUCTWORK, AND EXHAUST DUCTWORK SHALL BE 2" PRESSURE CLASS. 3. ALL SUPPLY DUCTWORK NOT SHOWN AS LINED SHALL BE WRAPPED WITH 1 -1/2" FIBERGLASS INSULATION (MIN. R-4). 4. DIMENSIONS ON DUCTWORK SHOWN LINED ARE OUTSIDE DUCT DIMENSIONS. 5. COORDINATE DUCT ROUTING WITH ALL OTHER TRADES BEFORE FABRICATION. 6. INSTALL DUCTWORK NO LOWER THAN 9' -7" TO ALLOW FOR FUTURE TENANT FINISH CEILING HEIGHT OF 9' -0". PLAN NOTES: O1 UP TO 2ND FLOOR - SEE SHEET H2.2 FOR CONTINUATION. O 14/12 LINED TRANSFER DUCT ABOVE CEILING LINE - MOUNT AS HIGH AS POSSIBLE. Scope Drawings These drawings indicate the general scope of the project in terms of orchikchrrol design concept, the dimensions of the building, the major arch tectural elements and the type ofstructural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all wads required for full performance and completion of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all ft ins required for the proper execution and completion of the work DRAWN by DES CHECKED by WRS DATE issued 17 OCT 2006 REVISIONS THE SCHNEIDER CORP. ASHTON FRITZ 8901 OTIS AVENUE INDIANAPOLIS, IN 46216 (317) 826 -7100 (317) 826 -7200 STRUCTURAL DESIGN, INC. CHUCK SCHAEFER 337 MAIN STREET BEECH GROVE, IN 46107 (317) 822.0204 (317) 822.0206 VECTOR CONSULTING BEN DEREMIAH 212 W. 10TH ST., SUITE D -395 INDIANAPOLIS, IN 46202 (317) 632.4444 (317) 632.4960 UJ Z z • w U > CN M IWZw0 I� w� U U .� UQ — �= —caw 0 N °e WW N Q � I~ tlr� No. e : 10200105 STATE OF 0.. STATE S�4.►111. NAL�" �\\. klA; P44:5 FIRST FLOOR PLAN HVAC SCALE AS NOTED H2.7 0