HomeMy WebLinkAbout06110089.33D I r C: B A.1 A 2 3 4 18/18 DOWN TO 1ST FLOOR OMEN OFFICE 206 24/12 16/12 24/12 MEDIUM PRESSURE SUPPLY DUCT FOR FUTURE TENANT 3.2 3.8' MEDIUM PRESSURE SUPPLY DUCT FOR FUTURE TENANT FINISH (TYP) 16/12 ROOM 203 1 RnmmD3 -2 0 .:.•....... ...`E1 -275 ', Ir tl El 15 6 80 N1ti► I r G1 -150 At , , E1 f _._. (60/14 r ; T VAV -3 DOWN 52/26 LINED UP TO RTU TO 1ST FLOOR SECOND FLOOR HVAC PLAN SCALE: 1/8" = 1' -0" I STAIR 1 p I ST-1 i 618 East Market Street I Indianapolis, Indiana 46202 ph 317/264.8162 fx 317/264.8165 a x i s a r c h. c o m GENERAL NOTES: 1. ALL SUPPLY DUCTWORK UPSTREAM OF VAV BOXES SHALL BE 4" PRESSURE CLASS. 2. ALL SUPPLY DUCTWORK DOWNSTREAM OF VAV BOXES, RETURN DUCTWORK, AND EXHAUST DUCTWORK SHALL BE 2" PRESSURE CLASS. 3. ALL SUPPLY DUCTWORK NOT SHOWN AS LINED SHALL BE WRAPPED WITH 1 -1/2" FIBERGLASS INSULATION (MIN. R-4). 4. DIMENSIONS ON DUCTWORK SHOWN LINED ARE OUTSIDE DUCT DIMENSIONS. 5. COORDINATE DUCT ROUTING WITH ALL OTHER TRADES BEFORE FABRICATION. 6. INSTALL DUCTWORK NO LOWER THAN 9' -7" TO ALLOW FOR FUTURE TENANT FINISH CEILING HEIGHT OF 9' -0 ". PLAN NOTES: 0 UP TO ATTIC; COORDINATE EXACT LOCATION OF PENETRATION WITH TRUSSES. O2 14/12 LINED TRANSFER DUCT ABOVE CEILING. Scope Drawings These drawings indicate the general scope of the project in temrt of orchiMcNral design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and Actricol systems. The drawings do not necessarily indicate or describe all work required for full pedomance and comple&n of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. DRAWN by DES CHECKED by VVRS DATE issued 17 OCT 2006 REVISIONS THE SCHNEIDER CORP. ASHTON FRITZ 8901 OTIS AVENUE INDIANAPOLIS, IN 46216 (317) 826 -7100 (317) 826 -7200 STRUCTURAL DESIGN, INC. CHUCK SCHAEFER 337 MAIN STREET BEECH GROVE, IN 46107 1 (317) 822.0204 (317) 822.0206 VECTOR CONSULTING BEN DEREMIAH 212 W. 10TH ST., SUITE D -395 INDIANAPOLIS, IN 46202 (317) 632.4444 (317) 632.4960 W I Z 1Z . Lu U QN M IWZw0 Lu O U U so W --� C - U Q — w w a� C� N E WW N - W v =v Q � dS I~ No. 1 10200105 *4 STATE OF : �/ JS�ONA.. � `11 =3 fffl1111111�1� CD Cr SECOND FLOOR PLAN m ly HVAC N SCALE AS NOTED m aa CID CD H2.2 (a 101 .0 12/4 1 16/10 16/10 1 I -- -�.... - MECH. N E 75 „�, D3 -300 VAV- 10 E1 -150H N ROOM - ' 2 ` � 100 N ' , 200 �,,� E1 -250 120 /20 L1141EI ;, E11 48/20 LIMED = -- / - _\ 48/20 LINED UP TO RTU 70/20 SCREENED OPENING ABOVE CEILING 44/12 DOWN TO 1ST - - - - -- - - FLOOR 24/12 MEDIUM PRESSURE SUPPLY DUCT FOR FUTURE TENANT 3.2 3.8' MEDIUM PRESSURE SUPPLY DUCT FOR FUTURE TENANT FINISH (TYP) 16/12 ROOM 203 1 RnmmD3 -2 0 .:.•....... ...`E1 -275 ', Ir tl El 15 6 80 N1ti► I r G1 -150 At , , E1 f _._. (60/14 r ; T VAV -3 DOWN 52/26 LINED UP TO RTU TO 1ST FLOOR SECOND FLOOR HVAC PLAN SCALE: 1/8" = 1' -0" I STAIR 1 p I ST-1 i 618 East Market Street I Indianapolis, Indiana 46202 ph 317/264.8162 fx 317/264.8165 a x i s a r c h. c o m GENERAL NOTES: 1. ALL SUPPLY DUCTWORK UPSTREAM OF VAV BOXES SHALL BE 4" PRESSURE CLASS. 2. ALL SUPPLY DUCTWORK DOWNSTREAM OF VAV BOXES, RETURN DUCTWORK, AND EXHAUST DUCTWORK SHALL BE 2" PRESSURE CLASS. 3. ALL SUPPLY DUCTWORK NOT SHOWN AS LINED SHALL BE WRAPPED WITH 1 -1/2" FIBERGLASS INSULATION (MIN. R-4). 4. DIMENSIONS ON DUCTWORK SHOWN LINED ARE OUTSIDE DUCT DIMENSIONS. 5. COORDINATE DUCT ROUTING WITH ALL OTHER TRADES BEFORE FABRICATION. 6. INSTALL DUCTWORK NO LOWER THAN 9' -7" TO ALLOW FOR FUTURE TENANT FINISH CEILING HEIGHT OF 9' -0 ". PLAN NOTES: 0 UP TO ATTIC; COORDINATE EXACT LOCATION OF PENETRATION WITH TRUSSES. O2 14/12 LINED TRANSFER DUCT ABOVE CEILING. Scope Drawings These drawings indicate the general scope of the project in temrt of orchiMcNral design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and Actricol systems. The drawings do not necessarily indicate or describe all work required for full pedomance and comple&n of the requirements of the contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. DRAWN by DES CHECKED by VVRS DATE issued 17 OCT 2006 REVISIONS THE SCHNEIDER CORP. ASHTON FRITZ 8901 OTIS AVENUE INDIANAPOLIS, IN 46216 (317) 826 -7100 (317) 826 -7200 STRUCTURAL DESIGN, INC. CHUCK SCHAEFER 337 MAIN STREET BEECH GROVE, IN 46107 1 (317) 822.0204 (317) 822.0206 VECTOR CONSULTING BEN DEREMIAH 212 W. 10TH ST., SUITE D -395 INDIANAPOLIS, IN 46202 (317) 632.4444 (317) 632.4960 W I Z 1Z . Lu U QN M IWZw0 Lu O U U so W --� C - U Q — w w a� C� N E WW N - W v =v Q � dS I~ No. 1 10200105 *4 STATE OF : �/ JS�ONA.. � `11 =3 fffl1111111�1� CD Cr SECOND FLOOR PLAN m ly HVAC N SCALE AS NOTED m aa CID CD H2.2 (a 101 .0