HomeMy WebLinkAbout06110089.4Ih,
U
Oh
O
cn
I
3/4" DIA. x16" SMOOTH
BAR ® 24" O.C.
1/2 x SLAB THICKNESS
c
C
I
C,
a
POLYMER SEALANT
IF COAT OR WRAP TO
rPREVENT BOND.
_ SLAB REINFORCING
PER PLAN
CONSTRUCTION JOINT
1/4" (f) SAWED OR
PREMOLDED JOINT
1* C14
• • 4.
.,
SLAB REINFORCING
PER PLAN
CONTROL JOINT
TYPICAL SLAB ON GRADE JOINTS
NO SCALE
IIVTQQIr)Q
TYPICAL COLUMN
NO SCALE
. I— I-
PLAN
(P. JT. MATERIf
a
c
(DC
I
CS
COL. PER DI At.
P_VTP'QIr)P
SOLATION JOINTS
SHIMS &
LEVELING
IL PER SCHEDULE NUTS I
COLUMN PER YF
Z
V)
I
z
0
Z
= t—
c,
SECTION
0
W
a_
z
to
—3/4" DIA. x V -3"
CH OR BOLTS
554 GR. 36)
HEX NUTS &
SHERS ® EA. END
COLUMN BASE DETAIL @ TS
NO SCALE
SHIMS
LEVELII
'L PER SCHEDULE NUTS
COLUMN PER
PLAN
t
PLAN SECTION
WQ-3 R "BOLTSx V -3"
1554 GR. 36)
UHEX NUTS &
SHERS ® EA. END
COLUMN BASE DETAIL @ WF
NO SCALE
DIM PER ARCH
1/2- EXP. JOINT
MATERIAL
V '
(—/ 4
— — — — — — — — — —
#4 x 1' -0"
DETAIL AT DOOR JAMBS
SCALE: 3/4" = V -0"
GENERA
Reference Architectural, Mechanical, Electrical, and Plumbing drawings for openings, sleeves, curbs, inserts, etc. not
herein indicated. All sleeves or openings required in structural members shall be approved by the Structural Engineer.
The structure has been designed for the final, in— service condition. It shall be the contractor's responsibility through
methods and means of construction to maintain the integrity of the structure during all stages of construction and
insure safe working conditions.
The Contractor shall be responsible for preparation of shop drawings to enable fabrication, erection and construction
all parts of the work in accordance with the drawings and specifications. Shop drawing review by the Structural
Engineer shall be for design conformance only. The Contractor shall be responsible for all dimensions, accuracy, and
fit of work.
FOUNDATIONS
Exterior foundations shall bear a maximum of 3' -0" below finish grade and shall bear on undisturbed soil.
Allowable Soil bearing pressures: 1,500 psf
Foundation excavations shall be made to plan elevations and inspected by a qualified Geotechnical Engineer. Soil
conditions found to be unacceptable shall be modified by one of the following procedures:
1. Remove all unacceptable soil and replace with compacted material as directed by the Geotechnical Engineer.
2. Lower foundations to an acceptable level and install concrete pedestals as directed by the Structural Engineer.
Foundation excavations shall be compacted to a level surface (or formed where soil conditions do not allow). The
excavation shall be protected from weather if concrete placement does not occur within 24 hours of excavation of the
footing.
CONCRETE
Reinforced concrete has been designed in conformance with the Building Code Requirements for Structural Concrete
(ACI 318) and Commentary (ACI 318R).
Concrete mixing, transporting, and placing shall be in accordance with the latest edition of the Specifications for
Structural Concrete for Buildings (ACI 301).
Concrete listed below shall be proportioned with sand fine aggregate and normal weight coarse aggregates (ACI
302.1R) and Type I Portland cement (ASTM C150). Compressive strength (f'c) at 28 days shall conform to the
following:
Spread footings and wall footings 3,000 psi
Sidewalks and exterior slabs 4,000 psi ( 6% + / -1% air entrainment)
Slabs on grade 3,500 psi
Slab on grade construction shall be in conformance with the latest edition of the Guide for Concrete Floor and Slab
Construction (ACI 302.1R) and the following minimum requirements:
Minimum cement content (interior uses) 5 sacks /cys
Minimum cement content (exterior uses) 6 sacks /cys
Maximum w/c ratio (interior uses) 0.48
Maximum w/c ratio (exterior uses) 0.45
Maximum slump prior to addition of plasticizers 3 inches
Maximum slump if plasticizers are not used 4 inches
(measured at point of discharge from pipe)
Do not finish surface until concrete has lost surface water sheen or all free water. Do not sprinkle cement on the
slab surface.
Concrete slabs shall be cured immediately after finishing using a sprayed on liquid curing compound or other methods
approved by the Structural Engineer.
Compressive strength tests shall conform to the requirements of ASTM C39. Specimens shall be taken in accordance
with the latest edition of ASTM C31. Each set shall include one cylinder tested at 7 days, 2 cylinders tested at 28
days and one cylinder retained in reserve. Test results shall be forwarded to the Structural Engineer for review and
comment.
Protect the concrete surface from precipitation and on hot, dry, windy days use wet burlap, plastic membranes or
fogging.
Construction joints between pours shall be prepared by roughening the contact surface to an amplitude of
approximately 1/4 inch, removing all surface laitance.
The contractor shall submit mix designs for each proposed class of concrete for the Structural Engineer to review.
REINFORCING STEEL
Reinforcing steel shall be deformed bars of new billet steel with a minimum yield strength of 60,000 psi conforming to
ASTM A615.
Detailing, fabricating, and placing of reinforcement shall be in accordance with the latest edition of the following
standards: Specifications for Structural Concrete for Buildings (ACI 301), ACI Detailing Manual(SP66).
Reinforcing bars shall not be welded, heated or cut unless shown on the contract documents.
Welded wire fabric shall be smooth wire fabric (ASTM A185), supplied in flat sheets.
Welded wire fabric shall be placed 2" down from the top of the slab for slabs on grade and lapped a minimum of 14
inches on all sides.
Concrete cover shall be as specified in the latest edition of ACI 318, unless notes otherwise on plan. Use standard
bar chairs and spacers to maintain concrete protection specified.
Splicing of reinforcing bars shall conform to latest edition of ACI 318. Use a Class "B" lap at splices unless indicated
elsewhere.
MASONRY
Concrete masonry design conforms to the latest edition of the Building Code Requirements for Concrete Masonry
Structures (ACI 530).
Concrete masonry construction shall be in accordance with the latest edition of the Specification for Concrete Masonry
Construction (ACI 530.1).
Minimum compressive strength (f'm) for concrete masonry units shall be 1,500 psi at 28 days.
Mortar mixes (type M below grade, type M or S above grade) shall be proportioned to meet the requirements of ASTM
C270 or C476.
Masonry walls shall be laterally braced in accordance with all applicable codes and design requirements until roof
construction is permanently installed.
MECHANICAL ANCHORS
Expansion and sleeve anchors shall be carbon steel anchors as manufactured by Hilti Fastening Systems or approved
equal.
Anchors shall be installed per manufacturer's recommendations.
Anchors shall not be installed in concrete until it has attained its specified minimum 28 day compressive strength
(f'c).
GROUT FOR COLUMN BASEPLATES
Grout for column base plates shall be a nonmetallic, non — shrink grout (complying with the requirements of ASTM C827
or CRD— C621), premixed, non — corrosive, non — staining product containing Portland Cement, silica sands, and fluidity
improving compounds. Minimum compressive strength (f'c) at 28 days shall be 4,000 psi.
Compressive strength tests shall conform to the requirements of ASTM C109.
618 East Market Street I
Indianapolis, Indiana 46202
ph 317/264.8162 fx 317/264.8165
a x is a r c h. c o m
Scope Drawings
These drawings indicate the general scope of
the projed in forms of architectural design
concept, the dimensions of the building,
the major architectural elements and the
type of structural, mechanical and electrical
systems. The draw ngs do not necessarily
indicate or describe all work required for
lull performance and completion of the
requirements of the contract On the basis
of the general scope indicated or described,
the trade contractors shall furnish all items
required for the proper execution and
completion of the work.
DRAWN by CJs
CHECKED by CPS
DATE issued 17 OCT. 2006
REVISIONS
SCHNEIDER CORP.
ASHTON FRITZ
8901 OTIS AVENUE
INDIANAPOLIS, IN 46216
(317) 826 -7100
(317) 826 -7200