HomeMy WebLinkAbout06110089.40PRESSURE GAU THERMOMETER - (TYPICAL) TMV -1 ASME TEMPERATURE AND PRESSURE RELIEF VALVE 3/4" TERMINATE RELIEF OVER FLOOR DRAIN TANK DRAIN VALVE 1" 1" SEE FLOOR PLANS — — — f —� FOR CONTINUATION 1 I' I [ ' CP -1 17 144.4 I 34J Cv 1" a �-- BALANCE VALVE 1„ N.O41— 3/a" 1" ET -1 1-7-71 0 ELEMENT ACCESS PANEL (TYP) I� DETAIL 'A' W HA FLOOR ELECTRIC WATER HEATER PIPING NO SCALE ZONE CONTROL VALVE WITH TAMPER SWITCH AND FLOW SWITCH THRU -WALL FIRE DEPARTMENT SIAMESE CONNECTION DOUBLE CHECK DETECTOR ASSEMBLY (DCDA) LIKE AMES 3000SS OR EQUAL. Q GRADE 4" SEE CIVIL DWGS F FOR CONTINUATION ww co Cn w 0 U a 0 CHECK VALVE DETAIL 'D' FIRE PROTECTION SPRINKLER SCHEMATIC NO SCALE mss, CD Cr M w CID (D M cQCID CID w Cn w a a W 0 J m 0 I SIZED PER HYDRAULIC CALCULATIONS TEST /DRAIN — 2" DRAIN FLOOR DRAIN THRU WALL @24" ABOVE ADJACENT GRADE. BRONZE PLUG 2" COMPACTED SAND BED - 1 Ilj 11 Y III 1 WYE AND 1/8 BEND WITH WITH CLEANOUT EXTENSION TO GRADE (SWING JOINT). CLEANOUT BOX WITH SOLID COVER 18 "x18 "x6 "D CONCRETE PAD GRADE BACKFILL - -_ DEPTH TO SEWER VARIES WYE AND 1/8 BEND IF PLACED IN SEWER LINE. 1/4 BEND IF PLACED AT END OF SEWER LINE. Y FLOW 1 I � DETAIL 'B' EXTERIOR CLEANOUT NO SCALE RISING STEM VALVES (TYP) WATER METER - COORD. — WITH UTILITY CO. REQ'TS (TYP) 2" I 24" 2" 24" 1 1" I 2" 2" DOMESTIC WATER FROM UTILITY _ WATER MAIN CAP OUTSIDE BUILDING—' FOUNDATION FOR FUTURE IRRIGATION SYSTEM 1" IRRIGATION TO POST HYDRANT — -- �--- -� TO BUILDING :y4 I 2" I RPZ -3 /e r2" RPZ -1 Lill FLOOR DRAIN —A� DETAIL 'C' 1" AIR GAP ASSEMBLY (TYP) v FLOOR NOTE: COORDINATE WATER METER INSTALLATION WITH VEOLIA WATER COMPANY REQUIREMENTS. WATER METER & BACKFLOW PREVENTER NO SCALE 2" 'o" I / �2 �2e -1Y2" I 1Y2" FROM MOP SINK Vo' THRU 1ST FLOOR DETAIL 'E' WASTE & VENT PIPING NO SCALE 4" 618 East Market Street Indianapolis, Indiana 46202 ph 317/264.8162 fix 317/264.8165 a x i s a r c h c o m Scope Drawings These drawings indcote the general scope of the project in terms of orchitedumf design concept, the dmrensiom of the building, the major architectural elements and the "a of smuciuml, mechanical and eAedrical systems. The drawings do not necessarily indicate or describe all wank required for lull performance and completion of the requirements of the contract. On the basis of the general scope indurated or dstcribed, the made contractors shall furnish ad items required for the proper exenrtion and completion of the work DRAWN by DES CHECKED by CKC DATE issued 17 OCT 2006 REVISIONS THE SCHNEIDER CORP. ASHTON FRITZ 8901 OTIS AVENUE INDIANAPOLIS, IN 46216 (317) 826 -7100 (317) 826 -7200 STRUCTURAL DESIGN, INC. CHUCK SCHAEFER 337 MAIN STREET BEECH GROVE, IN 46107 (317) 822.0204 (317) 822.0206 VECTOR CONSULTING BEN DEREMIAH 212 W. 10TH ST., SUITE D -395 INDIANAPOLIS, IN 46202 (317) 632.4444 (317) 632.4960 I W 0 Z zw U >CN Q M LU 7 w o — (!) "O oc w = J C Q p I ::Eu u .� C U �41% — w W a� � WW N D IOW =v IQ � IN `o No. : a' 10200105•` STATE OF . NAk- PLUMBING DETAILS SCALE AS NOTED I- P�.1 0