HomeMy WebLinkAbout06110089.41PLUMBING FIXTURE ROUGH -IN SCHEDULE TAG FIXTURE DESCRIPTION HW CW TRAP W V MOUNTING HEIGHT WC -1 WATER CLOSET - FLOOR OUTLET, FLUSH VALVE, ADA / 1" INTEGRAL 3" 2" 17' TO SEAT WC -2 WATER CLOSET - FLOOR OUTLET, FLUSH VALVE p 1" INTEGRAL 3" 2" 15' TO SEAT UR -1 URINAL - WALL HUNG, FLUSH VALVE, ADA I�I 3/4" INTEGRAL 2" 1 1/2' 17' TO RIM L -1 LAVATORY- DROP -IN, ADA 112" 1/2" 1 1/4" 1 1/2' 1 1/2' MOUNT IN COUNTERTOP L -2 LAVATORY- DROP -IN 1/2" 1/2" 1 1/4" 1 1/2" 1 1/2' MOUNT IN COUNTERTOP MB -1 MOP BASIN 3/4" 314" 3" 3" 1 1/2' MOUNT FAUCET 36" ABOVE FINISHED FLOOR EWC -1 ELECTRIC WATER COOLER G 1/2" 1 1/4" 1 1/2" 1 1/2' 36' TO BUBBLER HYDA WALL HYDRANT - FREEZE RESISTANT ECO 3/4" - - - 18' ABOVE ADJACENT GRADE HYD -2 POST HYDRANT - FREEZE RESISTANT 3/4" - - - 18' ABOVE ADJACENT GRADE SYMBOLS AND ABBREVIATIONS - COLD WATER - - HOT WATER - - - HOT WATER RETURN 140' HOT WATER (140° F) ZURN; WADE; WATTS; JOSAM STORM WATER (SUSPENDED) / STORM WATER (BURIED) I I SANITARY WASTE (SUSPENDED) //�- -- SANITARY WASTE (BURIED) - - - - SANITARY VENT LINE p DRAIN LINE J.R. SMITH 4021S (CARPET) NATURAL GAS LINE OWATER METER m BACKFLOW PREVENTER I�I WATER SHUT -OFF VALVE 4- GAS SHUT -OFF VALVE -1M CIRCUIT SETTER/HOT WATER BALANCING VALVE ­4V_- CHECK VALVE SECURED COVER. TEMP /PRESSURE RELIEF VALVE p-- -- ELBOW UP �---- ELBOW DOWN CAST -IRON BODY, DOUBLE FLANGED HOUSING, HEAVY -DUTY TEE UP ECO TEE DOWN ---� END CAP BRONZE PLUG, GASKET SEAL. UNION CW COLD WATER HW HOT WATER TW TEMPERED WATER V VENT W WASTE G NATURAL GAS FD FLOOR DRAIN FCO FLOOR CLEANOUT WCO WALL CLEANOUT ECO EXTERIOR CLEANOUT VTR VENT THROUGH ROOF CD Q M ,y CD -�s M CD CD rn DRAINAGE FITTING SCHEDULE TAG DESCRIPTION MANUFACTURER TRIM & ACCESSORIES FLOOR DRAIN: J.R. SMITH 2O05Y -A; AMERICAN STANDARD MADERA CAST -IRON, FLASHING COLLAR, BOTTOM NO-HUB OUTLET ZURN; WADE; WATTS; JOSAM FDA STRAINER: W -5 100 NICKEL BRONZE, ROUND, FLAT, ADJUSTABLE B SEAT: BENEKE 527; OLSONITE; CHURCH FLOOR CLEANOUT: J.R. SMITH 4221S (CONCRETE) W -10 CAST -IRON BODY, ROUND ADJUSTABLE SECURED NICKEL J.R. SMITH 4021S (CARPET) FCO BRONZE TOP, BRONZE PLUG, GASKET SEAL. J.R. SMITH 4141S (TILE) 5020 FLOOR MOUNTED, BATTERY POWERED SENSOR OPERATED ZURN; WADE; WATTS; JOSAM P.D.I CERTIFIED WALL CLEANOUT: J.R. SMITH 4720; WCO CHROME PLATED BRONZE ROUND FRAM AND ZURN; WADE; WATTS; JOSAM 400 SECURED COVER. DRAWN by DES EXTERIOR CLEANOUT: AMERICAN STANDARD 6561.017; FLUSH VALVE: SLOAN OPTIMA PLUS 8186 -1.0; CAST -IRON BODY, DOUBLE FLANGED HOUSING, HEAVY -DUTY J.R. SMITH 4251S; ECO SECURED SCORIATED CAST -IRON COVER WITH LIFTING RING, ZURN; WADE; WATTS; JOSAM FLUSH VALVE, ADA BRONZE PLUG, GASKET SEAL. CARRIER: J.R. SMITH, ZURN, WATTS, WADE, - ROOF DRAIN: J.R. SMITH 1015Y -C -R -CID; JOSAM CAST IRON, ADJUSTABLE EXTENSION SLEEVE, FLASHING ZURN; WADE; WATTS; JOSAM RD -1 CLAMP AND GRAVEL STOP, REVERSIBLE COLLAR, SUMP WHITE VITREOUS CHINA BOWL, COUNTER MOUNTED, RECEIVER, UNDERDECK CLAMP, BOTTOM NO -HUB OUTLET. STRAINER/TAILPIECE: MCGUIRE 155WC; ZURN DOME: KOHLER PTRAP: MCGUIRE 8902; ZURN CAST IRON. OVERFLOW ROOF DRAIN: J.R. SMITH 1045Y -C -R -CID; CAST IRON, ADJUSTABLE EXTENSION SLEEVE, FLASHING ZURN; WADE; WATTS; JOSAM RD -2 CLAMP AND GRAVEL STOP, REVERSIBLE COLLAR, SUMP (ADA ONLY) RECEIVER, UNDERDECK CLAMP, 2" EXTERIOR WATER DAM, MOP BASIN: MUSTEE 63M; APPROVED BOTTOM NO -HUB OUTLET. 009M2QT 1" 24" X 24" X 10" DEEP MOLDED FIBERGLASS BASIN, 3" IPS DOME: CAST IRON. HOSE & BRACKET: MUSTEE 65.7000 PLUMBING FIXTURE SCHEDULE TAG FIXTURE DESCRIPTION FIXTURE TRIM & ACCESSORIES WADE NO. WATER CLOSET: AMERICAN STANDARD MADERA FLUSH VALVE: SLOAN OPTIMA PLUS 8111; ZURN 3/4" FLOOR MOUNTED, BATTERY POWERED SENSOR OPERATED 2234.015; ELJER; KOHLER W -5 100 FLUSH VALVE, OPEN FRONT SEAT (NO COVER) B SEAT: BENEKE 527; OLSONITE; CHURCH WC -1 5010 W -10 200 P.D.I CERTIFIED WATER CLOSET: AMERICAN STANDARD MADERA FLUSH VALVE: SLOAN OPTIMA PLUS 8111; ZURN 5020 FLOOR MOUNTED, BATTERY POWERED SENSOR OPERATED 16 Y" 2305.100; ELJER; KOHLER P.D.I CERTIFIED D FLUSH VALVE, OPEN FRONT SEAT (NO COVER), ADA 61 - 113 SEAT: BENEKE 527; OLSONITE; CHURCH WC -2 400 P.D.I CERTIFIED DRAWN by DES URINAL: AMERICAN STANDARD 6561.017; FLUSH VALVE: SLOAN OPTIMA PLUS 8186 -1.0; ROUTE DRAIN TO FLOOR DRAIN WALL HUNG, BATTERY POWERED SENSOR OPERATED ELJER; KOHLER ZURN URA FLUSH VALVE, ADA 57 GPM @ 15PSI PRESSURE DROP CARRIER: J.R. SMITH, ZURN, WATTS, WADE, - JOSAM PROVIDE WITH AIR GAP FITTING LAVATORY: AMERICAN STANDARD FAUCET: DELTA 501 -WF; APPROVED EQUAL WHITE VITREOUS CHINA BOWL, COUNTER MOUNTED, AQUALYN 0476.028; ELDER; STRAINER/TAILPIECE: MCGUIRE 155WC; ZURN FAUCET LEDGE OVERFLOW, MANUAL OPERATING FAUCET. KOHLER PTRAP: MCGUIRE 8902; ZURN L -1, 2 STOPS: MCGUIRE 2165LK; ZURN PROTECTIVE COVER: TRUEBRO LAVGUARD; SLOAN (ADA ONLY) ROUTE DRAIN TO FLOOR DRAIN MOP BASIN: MUSTEE 63M; APPROVED FAUCET: CHICAGO 897- 1- 099XK; T &S BRASS; ZURN 009M2QT 1" 24" X 24" X 10" DEEP MOLDED FIBERGLASS BASIN, 3" IPS EQUAL HOSE & BRACKET: MUSTEE 65.7000 MB -1 CAST BRASS DRAIN WITH 16 -GA STAINLESS STEEL DOME MOP HANGER: MUSTEE 65.600 PROVIDE WITH AIR GAP FITTING STRAINER AND LINT BASKET. (IRRIGATION) (WILKINS; FEBCO) ELECTRIC WATER COOLER: OASIS PRAM; HAWS; HALSEY CARRIER: J.R. SMITH; ZURN; WADE; WATTS; JOSAM BARRIER FREE MODULAR UNIT; WALL HUNG, STAINLESS TAYLOR; ACORN AQUA P -TRAP: MCGUIRE 8902; BRASS CRAFT; ZURN STEEL TOP, POWDER COATED STEEL CABINET, GRID STOPS: MCGUIRE 2165LK; BRASS CRAFT; ZURN EWC -1 STRAINER, PUSH BAR OPERATED, ANGLE STREAM BUBBLER, 8 GPH, 115-60-1,1/4 HP, 4.6 FLA ROUTE DRAIN TO FLOOR DRAIN WALL HYDRANT: WOODFORD 65; JR SMITH; WATTS 009M2QT 3/4" BRASS BODY, WITH CHROME PLATED FINISH, STAINLESS ZURN; WATTS; WADE; JOSAM - STEEL OPERATING STEM, ANTI - SIPHON BACKFLOW HYDA PREVENTER, AUTOMATIC DRAINING, WALL CLAMP, FREEZE (POST HYDRANT) (WILKINS; FEBCO) PROOF DESIGN, LOOSE KEY HANDLE, 3/q' INLET, Y/4" HOSE THREAD OUTLET. POST HYDRANT: WOODFORD Y34; JR SMITH; BRADFORD WHITE M- 2- HE40S6DS FREEZE RESISTANT, 3/4" INLET, %" HOSE THREAD OUTLET. ZURN; WATTS; WADE; JOSAM 208 -1 -60 HYD -2 4.5 - - WATER HAMMER ARRESTER SCHEDULE TAG I.P.S. F.U. RATING J.R. SMITH NO. WADE NO. ZURN NO. REMARK A 3/4" 1 11 5005 W -5 100 P.D.I CERTIFIED B V 12 32 5010 W -10 200 P.D.I CERTIFIED C 1" 33 60 5020 W -20 300 P.D.I CERTIFIED D 1" 61 - 113 5030 W -50 400 P.D.I CERTIFIED PLUMBING EQUIPMENT SCHEDULE UNIT ELECTRICAL DATA GAS DATA NOTES TAG SPECIFICATION NAME MANUFACTURER MODEL # WEIGHT CAPACITY V -PH -HZ HP KW MBH IN MBH OUT 2. ALL UNDERLINED EQUIPMENT IS SCHEDULED, SEE P6.1 FOR indiwle or describe off work required for full performance and completion of #w SCHEDULES. requirements of the contract on#wbasis of the general scope indicated or described, the trade contractors shall fumish of/ rwns 3. CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER required for ifhe proper execution and completion afthewod TRADES PRIOR TO INSTALLATION. DRAWN by DES 4. MECHANICAL CONTRACTOR SHALL COORDINATE WITH CHECKED by CKC ROUTE DRAIN TO FLOOR DRAIN RPZ 1 BACKFLOW PREVENTER WATTS 009M2QT 1 112" 57 GPM @ 15PSI PRESSURE DROP - - PROVIDE WITH AIR GAP FITTING (DOMESTIC SERVICE) (WILKINS; FEBCO) ROUTE DRAIN TO FLOOR DRAIN RPZ -2 BACKFLOW PREVENTER WATTS 009M2QT 1" 15 GPM @ 15PSI PRESSURE DROP PROVIDE WITH AIR GAP FITTING (IRRIGATION) (WILKINS; FEBCO) ROUTE DRAIN TO FLOOR DRAIN RPZ -3 BACKFLOW PREVENTER WATTS 009M2QT 3/4" 5 GPM @ 15PSI PRESSURE DROP - PROVIDE WITH AIR GAP FITTING (POST HYDRANT) (WILKINS; FEBCO) WH -1 WATER HEATER BRADFORD WHITE M- 2- HE40S6DS 40 GALLON STORAGE; 20 GPH @ 90' F RISE 208 -1 -60 - 4.5 - - SET OUTLET TEMP AT 140 "F (LOCHINVAR; A.O. SMITH) TMV -1 THERMOSTATIC MIXING VALVE LAWLER 801 #72999 14 GPM @ 4 PSI DROP; 1 GPM MINIMUM FLOW - - SET OUTLET TEMP AT 120eF (LEONARD; POWERS) CP -1 CIRCULATOR PUMP ARMSTRONG ARMFLOW E713 - 4 GPM @ 17 FT. HD. 120 -1 -60 1/6 - ALL BRONZE BODY (TACO, B &G) ET -1 EXPANSION TANK THERM- X -TROL ST -5 2.0 GALLON TANK CAPACITY - (WATTS; TACO) 618 East Market Street Indianapolis, Indiana 46202 ph 317/264.8162 fx 317/264.8165 a xi s a r c h. c o m Scope Drawings GENERAL NOTES: 6@protrowinformscaMtdIodur vesiIgn of the project in Mans of orehiMCiural design concept the dimensions of the building, 1. THESE NOTES APPLY TO ALL PLUMBING DRAWINGS. "majoratural,mec anc land ct type of siructurol, mechanical and ekcirical "ms. The drawings do not necessonly 2. ALL UNDERLINED EQUIPMENT IS SCHEDULED, SEE P6.1 FOR indiwle or describe off work required for full performance and completion of #w SCHEDULES. requirements of the contract on#wbasis of the general scope indicated or described, the trade contractors shall fumish of/ rwns 3. CONTRACTOR SHALL COORDINATE WORK WITH ALL OTHER required for ifhe proper execution and completion afthewod TRADES PRIOR TO INSTALLATION. DRAWN by DES 4. MECHANICAL CONTRACTOR SHALL COORDINATE WITH CHECKED by CKC APPROPRIATE TRADE TO CUT AND PATCH FINISHED AREAS DATE issued 17 00 2006 AS REQUIRED, UNLESS OTHERWISE NOTED ON DOCUMENTS. REVISIONS 5. PROVIDE SLEEVES FOR ALL PIPING THAT PENETRATES FULL HEIGHT WALLS, WHETHER SHOWN OR NOT. 6. PROVIDE A CHECK VALVE ON HOT AND COLD WATER BRANCH LINES SERVING ALL MOP SINKS, WHETHER SHOWN THE SCHNEIDER CORP. ON NOT. 7. INSULATE ALL PLASTIC PIPING IN RETURN AIR PLENUMS TO ASHTON FRITZ MAINTAIN 2V50 FIRE SMOKE RATING AND AS DIRECTED IN I 8901 OTIS AVENUE SPECIFICATIONS. INDIANAPOLIS, IN 46216 8. ALL PLUMBING SYSTEMS TO BE INSTALLED TO MEET THE I (317) 826 -7100 REQUIREMENTS OF INDIANA PLUMBING CODE, 1999 (317) 826 7200 (UNIFORM PLUMBING CODE, 1997 WITH INDIANA AMMENDMENTS). STRUCTURAL DESIGN, 9. PIPE ROUTINGS INDICATED ON DRAWINGS ARE I INC. DIAGRAMMATIC AND ARE A SUGGESTED METHOD OF DESIGN. CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL COORDINATION, LAYOUT, CODE COMPLIANCE AND DESIGN. CHUCK SCHAEFER 337 MAIN STREET 10. COORDINATE VENT PENETRATIONS WITH MECHANICAL BEECH GROVE, IN 46107 ROOF TOP EQUIPMENT, REFER TO "H" SERIES DRAWINGS. I (317) 822.0204 OFFSET VENTS AS REQUIRED TO MAINTAIN MINIMUM 10' -0" (317) 822.0206 SEPARATION FROM AIR INTAKES. VECTOR CONSULTING 11. PROVIDE BUILDING SANITARY DRAINS, BUILDING STORM DRAINS AND DOMESTIC WATER SERVICE TO A POINT 5' -0" OUTSIDE BUILDING. COORDINATE UTILITIES WITH BEN DEREMIAH SITE /CIVIL ENGINEERS DRAWINGS. I 212 W. 10TH ST., SUITE D -395 INDIANAPOLIS, IN 46202 (317) 632.4444 (317) 632.4960 PIPING &INSULATION: PIPE MATERIAL: 1. DOMESTIC HOT & COLD WATER: TYPE L COPPER PIPE & FITTINGS 2. SANITARY WASTE & VENT: SCHEDULE 40 PVC DWV (SOLID CORE) PIPE & FITTINGS 3. STORM: SCHEDULE 40 PVC DWC (SOLID CORE) PIPE & FITTINGS 4. FIRE PROTECTION: 2"& SMALLER - SCHEDULE 40 STEEL 2Y2" & LARGER - SCHEDULE 10 STEEL W PIPE INSULATION: Z Z LU 1. DOMESTIC COLD WATER: FIBERGLASS 1" THICK WITH ASJ JACKET U CN 2. ALL PVC LINES IN RETURN AIR PLENUM: I W Z LU 0 FLEXIBLE ELASTOMERIC Y2" THICK. s / D NOTE: INSTALLATION OF INSULATION ON PVC LINES IN I w/ �Lu RETURN AIR PLENUMS SHALL START AT V -0" ABOVE FINISHED FLOOR. I � O C U U .� FIRE PROTECTION GENERAL NOTES: 1. SPRINKLER SYSTEM SHALL BE HYDRAULICALLY CALCULATED, FULLY SUPERVISED, AND INSTALLED ACCORDING TO NFPA 13. I . W W 2. CONTRACTOR SHALL OBTAIN FLOW TEST DATA FROM (n G UTILITY PRIOR TO DESIGN AND HYDRAULIC CALCULATION I I"� OF SPRINKLER SYSTEM. W N U \./ 3. ALL SPRINKLER SYSTEM ITEMS REQUIRED BY CODE SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR WHETHER SHOWN ON THE DRAWINGS AND SPECIFICATIONS OR NOT. 06 4. PIPE ROUTINGS INDICATED ON DRAWINGS ARE DIAGRAMMATIC AND ARE A SUGGESTED METHOD FOR DESIGN. CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL COORDINATION, LAYOUT, CODE COMPLIANCE, AND DESIGN. V 5. PROVIDE UPRIGHT HEADS IN UNFINISHED SPACES (IE: ' �■ THOSE WITH EXPOSED STRUCTURE), CONCEALED HEADS IN FINISHED SPACES (IE: THOSE WITH LAY -IN OR HARD CEILINGS), SIDEWALL HEADS WHERE IMPRACTICAL TO INSTALL CONCEALED OR UPRIGHT TYPE, OR AS INDICATED I ��1►iiliii► OTHERWISE ON THE DRAWINGS. ,���`��p.M•R: SJ 6. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR I �: �U'••� -� COORDINATION OF CEILING MOUNTED ITEMS. I _ N0. - 7. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE TO - a 10200105 ATTEND ALL BUILDING WALK- THROUGH'S (AFTER BUILDING I�. STATE OF IS OCCUPIED AND PRIOR TO THE END OF THE 1 YEAR iOi�•., '��` �iyDIANP � . WARRANTY PERIOD ) BY THE BUILDING FIRE MARSHAL AND I %���'S+••••••••••'��G�`� IS RESPONSIBLE FOR MAKING ANY MODIFICATIONS TO THE ��ii�NAiL`������`� SYSTEM REQUIRED AS A RESULT OF THIS BUILDING INSPECTION. �J ►II� 8. KNOX BOX WILL BE LOCATED NEAR FRONT ENTRANCE. SEE ARCHITECTURAL DRAWINGS. PLUMBING SCHEDULES SCALE AS NOTED i P6.1 0