HomeMy WebLinkAbout08050061.253/4" x 24 SHEATHING OVER 2" x 12" FYPON 7 449 -16 CROWN TRIM 1 x 8 TRIM ON TOP OF 1 x 8 TRIM 1 1/2 " DIAM. HALF ROUND 1 x 12 TRIM FYPON # COR 5 X 10 CORBEL CUT STONE WINDOW HEAD (SEE ELEV.) CUT STONE ON STEEL ANGLE ' VATH FLASHING BELOW CUT STONE CAULK TAL COPING CONTINUE EPDM UP & OVER NAILER 1 x 12 TRIM SQUARE A C VENT. (3) PER TOWNHO UNIT 12 3 f — PRE— ENGININRW ROOF TRUSS @ 24 0. . (2) LAYERS 5/$" GYP, D. ON BOTTOM OF TRUSSES BATT INSUL. (R30) FULLY ADHERED 4' -0" 2 1/4" 4' -0" E.P.D.M. OVER FIRE TREATED FIRE TREATED ROOF SHEATING W/ PLYWOOD PLYWOOD SPACERS FIBERGLASS SHINGLES (20 YEAR, 3 TAB) ON 15# BLDG. FELT OVER 1/2" ROOF SHEATHING MAINTAIN 2 CLEAR AIR SPACE FOR VENTING I� 11 11141 WOOD ROOF TRUSSES T/ PLATE BLOW INSUL TION UNDER & C\ ER ANY H VAC DUCTS. LOCATED IN ATTIC MAINTAIN R-30 AND BACKER ROD BTW. WIND. AND ANGLE. 2 -2x10 HEADER W/ (1) 1/2" OLI PLYWOOD FILLER VINYL SINGLE HUNG WINDOW j W/ TRANSOM. CAULK o0 PERIMETER OF EACH FACE (TYP.) DRYWALL WRAP SIDE AND HEAD RETURNS. r7 .-• I q SILL FLASHING u DRIP OVER 1 X TRIM i -A2 TRIM " HALF ROUND 'X' PATTERN TYP. WALL CONSTRUCTION: FIBER CEMENT PANELS ON TYVEK AIR BARRIER ON 7/16" SHEATHING ON 2x4 STUDS AT 16" O.C. WITH 3 1/2" R13 BATT INSULATION AND (1) LAYER 5/8" GYPSUI%,I BD. 1x2 TRIM FLASHING % /,'/' DRIP @WINDOW HEAD BRICK 01\1 STEEL "NGLE WITH FLASHING BELOW BRICK. CAULK AND BACKER ROD B T W. WIND. AND ANGLE. METAL FLASHING FROM BENEATH THRESHOLD FLASHING OVER STORE FR RT TRIMI TO DRIP EDGE AT TERMINATION 0 1 14 CROWN MOLD. 1 x TRIM 11T"' CROWN 3/4" OSB Rlf'r JOIST 1 1/2" HALF ROUND ON 1xi2 TRIM AND 1x4 TRIM 014 " SHEATHING ON 2x LADDER ! CAULK AMID BACKER C ROD BNJ, VVIND. AND ANGLE. 3/8" SOFFIT BOARD BRICK Y-NEER WITH WALL TIES AT 32" HORIZ. AND 16" VERT. W/ AIR SPACE AND WEEPS 8' -0" HIGH ATRIUM DOOR CD Q. cr < 4" and 6" STANDARD CONC. BLK. m m � f II FINISHED GRADE, I. m VERIFY IN FIELD rn CD 0 /4" T &G OSB SUBFLOOR FLOOR TRUSS @ 24" O.C. I 3rd.FLR. T/ LATE � ONE LAYER 5/8 "GYP. BD. ON BOTTOM OF TRUSSES HEADER BATT INSUL. (R19) " F.C. GYP. BRD. ATRIUM DOOR W/ c TRANSOM LITE r- 0 l THRESHOLD FLASHING 3/4" T &G OSB SUBFLO (R BATT INSUL. (R19) FLOOR TRUSS @ 24" 0 C. 2nd FLO. R . T /BEARIN HEADER co r O r 4" CONC. SLAB ON T. i 6 MIL POLYETHYLENE VAPOR BARRIER ON 12" PEA GRAVEL BED LOWER LEY 2" RIGID PERIM. INSUL. 10" CONC. LINE BLK. 0 U /W v 0 ry Q W� o 0 Il rmy ( W r i 00 i �I �I co (TYPICAL) m N m z m t- �U D < z 0 0 � m W I N T/ PLATE T /BEARING 10 .�•..,..:::���-•: .:•_: -,•,ter- •.._.:- �:.•.: _.,..�:::�.:�w.:....«..: -;•. _,.:..: -,_ GENE AL. NOTES: 7 1.) iCE &WATER SHIELD 36" @ 3.) DOWNSPOUTS TO TIE TO SITE EAVE, VALLEY & CRICKETS STORM DRAINAGE SYSTEMS, THROUGH BOOTS AND SUBSURFACE CONDUITS 2.) FLASH @ VERTICAL SURF -ACES 6" I UP & 6" HORIZONTAL 4.) DRAFT STOPS BETWEEN UNITS TO ROOF DECKING 5/8" F.C. DRYWALL ON 2x4 WALLS W/ DRAFT STOP TO ROOF DECK. CONTINUE DRAFT STOP INTO EAVES, TYP. PROVIDE GABLE TRUSS FOR SHEATHING. R -30 INSULATION • 25 MSG gaiv.scl. RESILIENT CHANNEL (2) LAYER 5/8" TYPE 'X' GYPSUM BD. CEILING ON BOTTOM OF TRUSSES. 2 .1 �- PROVIDE 1- SIMPSON HD2A o HOLD DOWN @ EACH END OF WALL (EACH SIDE) 2x10 ON 2 HR. UNIT SEP. ' WALL SEE WALL SECTION SHEET VENEER PER DRAWINGS FOR FLOOR /CEILING CONSTRUCTION TYVEC AIR BARRIER ON 9 7/16 ". EXTERIOR SHEATHING I $" GYP. BD. SHEATHING R -13 BATT INSULATION l(1) LAYER - 5/8" STANDARD ' 5/8" TYPE Y. GYP. BD. SHEATHING GYP, BD. BOARD CEILING TYP. WALL CONSTRUCTION ON BOTTOM OF TRUSSES. tf-IN PL-AI\l DETAIL AT EXTERIOR iriv— r) — UNIT SEPARATION WALL_ 2x4 SJUD WALL AT AT 12 0. C. 10" CONC. BLOCK — GROUT TOP COURSE SOLID SEE WALL SECTION SHEET e"19 NIL CONS RUCCTION (LING (1) LAYER 5/8" TYPE 'X' GYP. CAD, BOTH WALLS (1 ) LAYER 5/8" TYPE 'X' GYP. BD. BOTH WALLS GARAGE " • •• :. �'� �.,'• ANCHOR STRAPS 'DUNDEE '��' : . -. .4 y': #AS2' WITHIN 12" OF CORNER AND EVERY 2' -8" 10" C0NC. LINE BLK. A " ..�. •`a,. y; .,•f, •; • ..• POURED � � .:; '•a�; « •= C°r! GRADE BEAM UNIT SEPARATION WALL_ SECTION SCALE: 3/4 " =1' -0" 2 HR. RATED UNIT SEPARATION WALL (UL# BXUV.U311) 50 TO 54 STC (est.) NOTE: SEE OVERALL BUILDING PLANS FOR LOCATION OF 2 —HR. CONSTRUCTION NOTE: EXTERIOR WALLS ARE NON —RATED CONSTRUCTION HAVING 5/8" GYPSUM BOARD, TYPICAL - 5/8" TYPE 'X' GYPSUM BD. 2 1 /4" 2 1/4" NOTE: ANCHOR BOLTS MUST NOT EXCEED 6' -0" O.C. AND SHALL BE LOCATED WITHIN 12" . FROM THE ENDS OF EACH PLATE SECTION AND WITHIN 12" FROM EVERY CORNER NOTE: FIRECAULK ALL PENETRATIONS IN RATED ASSEMBLIES — 5/8" TYPE 'X' GYPSUM BRD. 5/8" TYPE 'X' GYPSUM BRD. MIN. WOOL INSUL. EACH SIDE (EACH SIDE) FLOOR CONSTRUCTION PER WALL SECTION SHEET (TRUSS DIRECTION MAY VARY) 3rd FLR. MIN. WOOL INSUL. EACH SID 5/8" TYPE 'X' GYP. 6D. ON BOTTOM OF FLR. TRUSSES MIN. WOOL INSUL. EACH SIDE 5/8" TYPE 'X' GYPSUM BD. FLOOR/CEILING ASSEMBLY ,UNIT SEPARATION WALL SCALE: 1 1/2"=l'-O" NOTE: INSTALLATION PER LISTING REQUIREMENTS — NO MATERIAL SUBSITUTIONS -IANNEL (U.L. #BXUV.Ul) GA FILE #WP3240 FLOORZCEILING ASSEMBLY UNIT SEPARATION WALL (UL �BXUV.U31i) SCALE: 1 1/2"=l'—O" NOTE: INSTALLATION PER LISTING REQUIREMENTS — NO MATERIAL SUBSITUTIONS v 1� O r, •S. < g L 0 `atuiutt ",i,,r � E • 836 x t S'-/A- ~0 r 5r i NO •R.:. ITS :: ~ J :�.. POURED CONC. :� . `: ,••.'' .::. `• GRADE _I y_ • ._ BEAM 2" RIGID PERIM. INSUL. 10" CONC. LINE BLK. 0 U /W v 0 ry Q W� o 0 Il rmy ( W r i 00 i �I �I co (TYPICAL) m N m z m t- �U D < z 0 0 � m W I N T/ PLATE T /BEARING 10 .�•..,..:::���-•: .:•_: -,•,ter- •.._.:- �:.•.: _.,..�:::�.:�w.:....«..: -;•. _,.:..: -,_ GENE AL. NOTES: 7 1.) iCE &WATER SHIELD 36" @ 3.) DOWNSPOUTS TO TIE TO SITE EAVE, VALLEY & CRICKETS STORM DRAINAGE SYSTEMS, THROUGH BOOTS AND SUBSURFACE CONDUITS 2.) FLASH @ VERTICAL SURF -ACES 6" I UP & 6" HORIZONTAL 4.) DRAFT STOPS BETWEEN UNITS TO ROOF DECKING 5/8" F.C. DRYWALL ON 2x4 WALLS W/ DRAFT STOP TO ROOF DECK. CONTINUE DRAFT STOP INTO EAVES, TYP. PROVIDE GABLE TRUSS FOR SHEATHING. R -30 INSULATION • 25 MSG gaiv.scl. RESILIENT CHANNEL (2) LAYER 5/8" TYPE 'X' GYPSUM BD. CEILING ON BOTTOM OF TRUSSES. 2 .1 �- PROVIDE 1- SIMPSON HD2A o HOLD DOWN @ EACH END OF WALL (EACH SIDE) 2x10 ON 2 HR. UNIT SEP. ' WALL SEE WALL SECTION SHEET VENEER PER DRAWINGS FOR FLOOR /CEILING CONSTRUCTION TYVEC AIR BARRIER ON 9 7/16 ". EXTERIOR SHEATHING I $" GYP. BD. SHEATHING R -13 BATT INSULATION l(1) LAYER - 5/8" STANDARD ' 5/8" TYPE Y. GYP. BD. SHEATHING GYP, BD. BOARD CEILING TYP. WALL CONSTRUCTION ON BOTTOM OF TRUSSES. tf-IN PL-AI\l DETAIL AT EXTERIOR iriv— r) — UNIT SEPARATION WALL_ 2x4 SJUD WALL AT AT 12 0. C. 10" CONC. BLOCK — GROUT TOP COURSE SOLID SEE WALL SECTION SHEET e"19 NIL CONS RUCCTION (LING (1) LAYER 5/8" TYPE 'X' GYP. CAD, BOTH WALLS (1 ) LAYER 5/8" TYPE 'X' GYP. BD. BOTH WALLS GARAGE " • •• :. �'� �.,'• ANCHOR STRAPS 'DUNDEE '��' : . -. .4 y': #AS2' WITHIN 12" OF CORNER AND EVERY 2' -8" 10" C0NC. LINE BLK. A " ..�. •`a,. y; .,•f, •; • ..• POURED � � .:; '•a�; « •= C°r! GRADE BEAM UNIT SEPARATION WALL_ SECTION SCALE: 3/4 " =1' -0" 2 HR. RATED UNIT SEPARATION WALL (UL# BXUV.U311) 50 TO 54 STC (est.) NOTE: SEE OVERALL BUILDING PLANS FOR LOCATION OF 2 —HR. CONSTRUCTION NOTE: EXTERIOR WALLS ARE NON —RATED CONSTRUCTION HAVING 5/8" GYPSUM BOARD, TYPICAL - 5/8" TYPE 'X' GYPSUM BD. 2 1 /4" 2 1/4" NOTE: ANCHOR BOLTS MUST NOT EXCEED 6' -0" O.C. AND SHALL BE LOCATED WITHIN 12" . FROM THE ENDS OF EACH PLATE SECTION AND WITHIN 12" FROM EVERY CORNER NOTE: FIRECAULK ALL PENETRATIONS IN RATED ASSEMBLIES — 5/8" TYPE 'X' GYPSUM BRD. 5/8" TYPE 'X' GYPSUM BRD. MIN. WOOL INSUL. EACH SIDE (EACH SIDE) FLOOR CONSTRUCTION PER WALL SECTION SHEET (TRUSS DIRECTION MAY VARY) 3rd FLR. MIN. WOOL INSUL. EACH SID 5/8" TYPE 'X' GYP. 6D. ON BOTTOM OF FLR. TRUSSES MIN. WOOL INSUL. EACH SIDE 5/8" TYPE 'X' GYPSUM BD. FLOOR/CEILING ASSEMBLY ,UNIT SEPARATION WALL SCALE: 1 1/2"=l'-O" NOTE: INSTALLATION PER LISTING REQUIREMENTS — NO MATERIAL SUBSITUTIONS -IANNEL (U.L. #BXUV.Ul) GA FILE #WP3240 FLOORZCEILING ASSEMBLY UNIT SEPARATION WALL (UL �BXUV.U31i) SCALE: 1 1/2"=l'—O" NOTE: INSTALLATION PER LISTING REQUIREMENTS — NO MATERIAL SUBSITUTIONS v 1� O r, •S. < g L 0 `atuiutt ",i,,r � E • 836 x t S'-/A- ~0 r 5r i NO