Loading...
HomeMy WebLinkAbout08050061.27go to °o? x-`° B f OC n a� i , a ` �f 'f 13 M a _ N v o ; 'z CL m o r n Cii CONTRACT LUMBER REV. DATE REMARKS GUNSTRA 15590 W. 'NORTHMELD DR. SHEET rz�4M ' � "�� BROMISBURG, IN 46772 1 _ 2 _ _ FAX ((3177) 852-8996 5 89 Walsh Engineering Services, P.C. Project No. 06246 8826 Southeastern Ave,, Wanamaker, TN 46239 December 7, 2006 'hone: 317 -862 -4738 Fax: 317 - 862 -4758 E -mail: eng @,walengsvc.com Dave Wilson Contract Lumber 1590 W. Northfield Dr. Brownsburg, IN 46112 Re: Gunstra - Monon and Main :Dear Dave: Per your request, we analyzed the cantilevered deck beams on the above referenced project. The treated, No. 2 Yellow fine 2 -2x10 beams are 15' -10 %s" long. 'l. 'hc overall width of the deck is 12' -3 %z" with the beam cantilevered 4' -2'/" past the end of the floor truss. There are a total of 4 beams-, with two of the beams connecting to each side of the same truss. The 2x10 that connects to the floor truss is to have a 14d nails at a maximum of 12" o.c. into the bottom chord of the truss. Use 3 -16d nails at 16" o.c. to connect the second 2x10. This concludes the scope of engineering work requested. If further technical assistance is needed, please call. 0%J1u11ti�hri�i ST Sincerely,, r'rQ� No Walsh Engineering Services, P.C. • ( ,pso�aaa • ./ .,^- �^ o.. STATE OF 'yN "/O �. Katherine Halley -Ames, P.E. /�NA�`N' Engineer s = Sao= Mark Walsh, P.E. President •,�•? ••' DAPR0JF('T9\0624610624b -1 .wpd 1 E 'v Ci— U G now v �r� 'I ----; ! FLOOR TRUSS — --9. - @---- 12,,3 1/27 qto 1m ,m r cor �� pr r Cl co co a rL in CL o � o 0 C N � _ N v o ; 'z CL m o r n Cii CONTRACT LUMBER REV. DATE REMARKS GUNSTRA 15590 W. 'NORTHMELD DR. SHEET rz�4M ' � "�� BROMISBURG, IN 46772 1 _ 2 _ _ FAX ((3177) 852-8996 5 89 Walsh Engineering Services, P.C. Project No. 06246 8826 Southeastern Ave,, Wanamaker, TN 46239 December 7, 2006 'hone: 317 -862 -4738 Fax: 317 - 862 -4758 E -mail: eng @,walengsvc.com Dave Wilson Contract Lumber 1590 W. Northfield Dr. Brownsburg, IN 46112 Re: Gunstra - Monon and Main :Dear Dave: Per your request, we analyzed the cantilevered deck beams on the above referenced project. The treated, No. 2 Yellow fine 2 -2x10 beams are 15' -10 %s" long. 'l. 'hc overall width of the deck is 12' -3 %z" with the beam cantilevered 4' -2'/" past the end of the floor truss. There are a total of 4 beams-, with two of the beams connecting to each side of the same truss. The 2x10 that connects to the floor truss is to have a 14d nails at a maximum of 12" o.c. into the bottom chord of the truss. Use 3 -16d nails at 16" o.c. to connect the second 2x10. This concludes the scope of engineering work requested. If further technical assistance is needed, please call. 0%J1u11ti�hri�i ST Sincerely,, r'rQ� No Walsh Engineering Services, P.C. • ( ,pso�aaa • ./ .,^- �^ o.. STATE OF 'yN "/O �. Katherine Halley -Ames, P.E. /�NA�`N' Engineer s = Sao= Mark Walsh, P.E. President •,�•? ••' DAPR0JF('T9\0624610624b -1 .wpd 1 E 'v Ci— U G now v �r� 'I