HomeMy WebLinkAbout0267.98.10CD
rn
N
0
P
a
i
NOTE:
SCUPPER OPENING
TO BE SIZED PER
U.P.C. APPENDIX D
AND LOCAL CODE
REQUIREMENTS
ELASTOMERIC
SEALANT ON
ALL SIDES
SCUPPER FLASHING
BUILDING PARAPET -
2x2x1/8" 'C' CHANNEL
OR UNISTRUT -LAG BOLT
7
TO PARAPET 0 BLK'G &
CUT & BEND 0 90'
ANGLE
PIPE CLAMP -BOLT TO
CHANNEL (2 THUS) /
I �
HOT WATER HEATER FLUE
------- -L - -��
I I
I I
I I
I I I
I I
c0
0
c
c
r
FLUE SUPPORT DETAIL
- CAP SHEET FLASHING SHEET
i
- VERTICAL WALL CAULK AROUND-
PERIMETER -
- I PLY SHEET SET IN ASPHALT BEHIND FLANGE CONTINUOUS
i PREFINISHED --
- 2 REINFORCEMENT PLIES SET IN ASPHALT METAL FLASHING
- 24 GA. G.I. SCUPPER FLASHING- AS REQUIRED
SET PRIMED FLANGES INTO ROOF
CEMENT OVER FIELD PLIES AND
NAIL FLANGES TO ALL SURFACES -SEE DETAIL 13/A6 FOR
USING APPROPRIATE FASTENERS TYPICAL. DIMENSIONS - ONS
SEAL CUT EDGES AT SCUPPER OPENING USING WOVEN GLASS
FABRIC EMBEDDED INTO AND COVERED WITH FLASHING CEMENT
- FIBERGLASS BASE SHEET NAILED TO DECK
OVER ROSIN SLIP SHEET
GRANULE SURFACED FIBERGLASS CAT' SHEET
4" L
3 PLIES TYPE N FIBERGLASS -PLY SHEET
_ ROSEN SHEET
PREFINISHED --
METAL SCUPPER
& DOWNSPOUT
CAP SHEET FLASHING SHEET ( °
C) (�
PLYWOOD DECK
i I
0
0
1/2 " =1' -0"
9
ROOF CRICKET
STUCCO CORNER
ANCHORS W/ NEOPRENE /STL.
BEAD, TYP.
WASHERS 0 1' -4" O.C.
3/4" EXT. ,
PAINTED 22 GA. GALVANIZED CAP
GR. PLYWD OVER
WATERPROOFING MEMBRANE
3" STUCCO, TYP.
(2) 2x6 TREATED WD. TOP
3" X 1 1/2" GALV
PLATES SPLICE PER 2 /AD1
'B'
NEAR SIDE OF PARAPET
TYPE
WINATION BAR-
'END UP UNDER COPING
FIBER CANT
SHING- ANCHORS W/
2x6 WD STUDS
)PRENE /STL WASHERS
J -MTL. STUCCO TRIM
B" O.C.
2" STL PIPE TO BE
WD STUDS
+17' -6"
7/8" STUCCO, TYP.
IV T. 0. P. N
2x6 WD STUDS
N
!' EXT. PLYWOOD
M
FLASHING TURNED UP
HOLD -DN
IIND PLASTER
CLEATS yy/ 1/2'x 2.5"
CCO STOP
WD SCREW 0 24 "o.c.
CAP BELOW
cv ARE TO BE SUPPLIED & INSTALLED
N
c:' BY OTHERS
0
PLAN SECTION DETAIL 3 " =1' -0"
110
N
2x4 WD. BLK'G. �,. ;
MTL FLASH'G W/
20 GA. PAINTED GALV
STUCCO CORNER
10 CAP W/ CONT. CLEAT-
BEAD, TYP.
A6 TURN UP END BEHIND
3/4" EXT. ,
PLASTER
GR. PLYWD OVER
2x6 P.T.D.F.
2x4 WD. BLK'G.
— — WATER PROOFING
EYELET LOCATION AT
MEMBRANE- TURN UP
NEAR SIDE OF PARAPET
BEHIND PLASTER
SEE SHT. A7
2x6 TREATED WD TRIM
_
OVER ROOFING- CHAMFER
2x6 WD STUDS
TOP EDGE, SET IN MASTIC
7/8" STUCCO, TYP.
& LAr SCREW TO WD. STUDS
2" STL PIPE TO BE
0 32 O.C.
ANCHORS W/
7/8" STUCCO, TYP.
NEOPRENE /STL
2x6 WD STUDS
WASHERS 0 8" O.C.
W
THE ROOF SURFACE
INSTALL BASE SHT. & CAP
SHEET TO TOP OF
2X4 DIAG. TO TOP CHORD
PARAPET WALL
o
FLAGPOLE & FLAGPOLE BRACKETS -
cv ARE TO BE SUPPLIED & INSTALLED
o°ar
c:' BY OTHERS
0
(y)
STL PIPE TO BE SECURED TO
D ETAI L 3 " =1' -0"
1 1
PARAPET
8 OVERFLOW SCUPPER
CONTINUOUS CANT STRIP
2x WD BLOCKING
ROOFING OVER 5/8"
PLYWOOD CRICKET OVER
2x FRAMING 0 24' O.C.
ROOF DIAPHRAGM
PLYWOOD
3" =1' -0"
II
II
�I
�JI I
N � �
T_ 4
3" =1' -0"
24 GA. GALV.
METAL REGLE'
AND REMOVAE
FLASHING
COUNTERFLASHING
CAP SHEET
F
24 GA. SCUPPER
FLASHING, SET
PRIMED FLANGES
INTO ROOF CEMENT
OVER FIELD PLIES
AND NAIL FLANGES
7 TO ALL SURFACES
USING APPROPRIATE
FASTENERS
3 PLY BUILT -UP
ROOF OVER 5/8"
CDX PLYWOOD
ROOF DECK, TYP.
'UPPER OVERFLOW SCUPPER
SEE DET. 5/A6
THRU -WALL SCUPPER
& DOWNSPOUT, " " "
SEE DET. 8/A6 3 -6 1 -6 3 11 2 -8 ZZ
E: ALL
MS 0
3HING TO
dt SOLDERED
ALL
'AS 0
;RING TO
bt SOLDERED
5 1 SCUPPER FLASHING
7/8" STUCCO
EXTERIOR PLYWD
0 PARAPET
J -MOLD
6 PLASTER FLASHING DETAIL NTS 2
MIN. 24 GA. G.I. PIPE
ENCLOSURE COVER
MULTI PIPE GROUPING
- = 1- HEAD -NAIL 0
6" - 8" O.C.
SCREW THRU NEOPRENE
WASHER , 3 PER SIDE
CAP SHEET FLASHING
r 1.7- L T
�- 2 REINFORCEMENT PUES
SET IN ASPHALT
F16ER CANT STRIP W/ 4"
LEGS -NAIL TO DECK
AND /OR CURB 0 12" O.C.
CO 2x8 WD CURB SECURED
TO ROOF DECK
f-
MULTIPLE PIPE FLASHING
/ / I
/ /^I �( -- SATELLITE DISH TO BE
NZ / PROVIDED & INSTALLED BY T.B.
1 / �
7 SATELLITE DISH SUPPORT N.T.S. 4 ROOF PLAN
J.
VO 11
\\ A6
\ \ 2' X 3' WALK -MATS r - -
DO NOT MAKE ROOF \ \ H AS STRETCHED TYP. I I
PENETRATIONS EITHER \ \ A10 1 I
SIDE OF VALLEY FOR
DISTANCE OF 18" TYP. \\ \ A6 5' -10"
no
\ \ HVAC
\ \ UNIT #1
\\ °off \ SD1 ROOF SADDLE
x
O\ \ I 1 1 i I
--1 \ 3
L , , \ PE A6
w EF- \\ \ I I
0 100# \ \\ I I
cn
\ \ -
\ \\ 100# 400# 400# `1
\ \ N
YY \ \ \ -
ICE MACHINE
A8 \ CONDENSER
/ F_ -I 8' -8" 2
/ // L J
12' -6" /
EF -2
100#
nrL.,
EF -3
VENT THRU ROOF 100#
SEE SHT. P1 FOR
DIMENSIONAL LOCATION
w SEE DET. 2/A6.1 0
a / Q
/ �° // SATELLITE DISH, SEE DET. 4/A6
AND ROOF FRAMING PLAN
FOR LOCATION SEE DET.
2/A6.1
PARAPET WALLS ARE 47" TO 61' HIGH
/ 9' -4"
/ 3
o
/ I I
/ DO NOT MAKE ROOF I i
/ PENETRATIONS EITHER
SIDE OF VALLEY FOR
/ DISTANCE OF 18" TYP.
/
- HVAC
v UNIT #2
\ / I ROOF LE
v
\ 2' X 3' WALK -MATS I X I r - -' 11
AS STRETCHED TYP. �� i e f - SD 1 I*
\\
\ 6 OF COVERIN
\ SHALL BEAR UL LABELS WITH FIRE
t \\ EXPOSURE CLASS 'A' i
it
\\ SLOPE 1/2- PER FOOT `�' i
\ p� \ 5 114
\ \ 4
\ 3
\ \ 2
a \ \G
\ \ , on
WW
A8
ROOF CRICKET
SEE 6 /A6
THRU-WALL SCUPPER-
& DOWNSPOUT,
/ i
8/A6
MTL FLASH'G W/
SCUPPER-
10
5/A6
xx
1" X 1/4" DRAW BAND
A8
`„
INDICATES
2x6 P.T.D.F.
SET IN NON- HARDENING SEALANT
(TYP.)-
SEE DTL.
�z
co
4.
IN FASTEN FLANGE
zQ_
W
TO PLYWD DECK
�z
z
2" STL PIPE TO BE
_
Q
Q
EXTENDED 2' -6" ABOVE
W
THE ROOF SURFACE
2X4 DIAG. TO TOP CHORD
Q
L_L
OF ADJACENT TRUSSES
�U
0
(y)
STL PIPE TO BE SECURED TO
T
TRUSSES W /SIMPSON PGT2 W/
(4)1/4- LAG BOLTS (TOP & BOT.)
-DRILL & BOLT PIPE TO TRUSS
_
0
W/ 3/8" DIA BOLTS
SIMPSON PGT2
7 SATELLITE DISH SUPPORT N.T.S. 4 ROOF PLAN
J.
VO 11
\\ A6
\ \ 2' X 3' WALK -MATS r - -
DO NOT MAKE ROOF \ \ H AS STRETCHED TYP. I I
PENETRATIONS EITHER \ \ A10 1 I
SIDE OF VALLEY FOR
DISTANCE OF 18" TYP. \\ \ A6 5' -10"
no
\ \ HVAC
\ \ UNIT #1
\\ °off \ SD1 ROOF SADDLE
x
O\ \ I 1 1 i I
--1 \ 3
L , , \ PE A6
w EF- \\ \ I I
0 100# \ \\ I I
cn
\ \ -
\ \\ 100# 400# 400# `1
\ \ N
YY \ \ \ -
ICE MACHINE
A8 \ CONDENSER
/ F_ -I 8' -8" 2
/ // L J
12' -6" /
EF -2
100#
nrL.,
EF -3
VENT THRU ROOF 100#
SEE SHT. P1 FOR
DIMENSIONAL LOCATION
w SEE DET. 2/A6.1 0
a / Q
/ �° // SATELLITE DISH, SEE DET. 4/A6
AND ROOF FRAMING PLAN
FOR LOCATION SEE DET.
2/A6.1
PARAPET WALLS ARE 47" TO 61' HIGH
/ 9' -4"
/ 3
o
/ I I
/ DO NOT MAKE ROOF I i
/ PENETRATIONS EITHER
SIDE OF VALLEY FOR
/ DISTANCE OF 18" TYP.
/
- HVAC
v UNIT #2
\ / I ROOF LE
v
\ 2' X 3' WALK -MATS I X I r - -' 11
AS STRETCHED TYP. �� i e f - SD 1 I*
\\
\ 6 OF COVERIN
\ SHALL BEAR UL LABELS WITH FIRE
t \\ EXPOSURE CLASS 'A' i
it
\\ SLOPE 1/2- PER FOOT `�' i
\ p� \ 5 114
\ \ 4
\ 3
\ \ 2
a \ \G
\ \ , on
WW
A8
ROOF CRICKET
SEE 6 /A6
THRU-WALL SCUPPER-
& DOWNSPOUT,
SEE DET.
8/A6
OVERFLOW
SCUPPER-
S E DET.
5/A6
xx
A8
INDICATES
2x6 P.T.D.F.
WD. NAILERS
(TYP.)-
SEE DTL.
7/A6.
ROOF CRICKET
SEE 6/A6
1
A6.1
12 x24"
TOWER VENT
Li
a
0
1
A6.1
'C' CHANNEL FLUE SUPPORT -
SEE DET. 9/A6
SLOPE
4" DIA. WATER HEATER FLUE
MIN. 2' -0" ABOVE PARAPET
WALL AND MIN. 3' -0" ABOVE
AIR INTAKE SEE DETS. 8/P3 & 4/A6.1
EQUIPMENT RAILS BY G.C.
SEE DIET. 7 /SD 1
WALK -IN FREEZER/
COOLER CONDENSORS
(TYP. OF 2)
1
A6.1
1
A6.1
MIN. 4" LAP 0 PARAPET
CAP FLASHING SEAM (TYP.)
SEE DET. 6/A6.1
A6.1
12 "x24"
TOWER VENT
5 PLY BUILT -UP
ROOFING W/
MINERAL CAP
4" FIBER CANT, TYP.
GEN. NOTES:
1. FOR MMIIMUM CLEARANCES ON VARIOUS PIPES
& PENETRATIONS SEE DET. 3/A6.1
v
v
XX
A8
Cy 1
W
U
4
W U
a �
q
Ld ri
m s
o
Q
u
0
Q
Q
0
W
wz
zQ_
W
�z
z
z
_
Q
Q
J
W
U
Q
L_L
0
�U
0
(y)
T
OWN BY TTP
CHWn BY- TH
aLam TYPE
—50
K
FRAME
JOB NUMMR
97125
PROTOTYPE ISSUE DATE
2/l/97.1
-_J