Loading...
HomeMy WebLinkAbout0267.98.11co rn N 0 L0 RAI N ri 53 v ^" V STL DECKING t: WHEELING CORRUGATING E 75 " SO MTL FRAME 0 a 0 VERTICAL SECTION - FRONT EDGE OF AWNING M O FIBERGASS BASE SHEET WM TO WALL VOU ICk WALL CAP SHEET WALL COVERING �---1" HEAD NAIL AT 6--;r O.C. 2 REINFORCEMENT PLIES rt I CAP SHEET rl� FIBER , CANT STRIP W/ 4! LEGS 1' NAJL TO PLYWOOD • 3 PLIES TYPE IV FIBERGLASS FIBERGLASS BASE SHEET NAILED TO DECK OVER ROSIN sup s`7 ask om war, I :r L tVM* ALL S&AG MUST BE SOLDERED 1 /Y' I --- v - MUAL AS SPEC*lED -' � 24 GA. GA, 15 OZ COPPER OR 511 � 1 24 GA STA114LESS STEEL - SECURED A }' GRANULE SURFACED FIBERGLASS CAP SHT. Ylli?u APPROPRIATE FASTENERS -PLYWOOD DECK WALL BASE FLASHING -1•-ff' COPING TO WALL TRANSITION 1 20 GA. G.I. COVER PLATE SET INTO SEALANT BEAD APPLIED ALONG BOTH SIDES OF JOINT - SECURE USING SCREW THRU STEEL /NEOPRENE WASHER CENTERED OVER 1/4' GAP BETWEEN ADJACENT SECTIONS f "E"' ^ ^^"^ ' SECURE OUTSIDE FAC SECTIONS USING TWO THRU SLOTTED HOLES UNDER COVER PLATE SCREW THRU NEOPRE WASHER AT 30" O.C. 0 20 GA. G.I. CAPS FLAS 0 COPING JOINT 0 a 0 to ul SEALED PIPE FLASHING 6 7/8" STUCCO FIN. 1/2- EXT. GR. PLYWD. OVER 2x6's 0 16" O.C. (TYP.) 1.5" SO MTL FRAME GALV STL DECKING MFR: WHEELING CORRUGATING TYPE 75 J. VERTICAL SECTION - TOP OF AWNING FRAME AT FLAT WALL 7/8" STUCCO FIN. }...' 1/2.0 EXT. GR. PLYWD. OVER 2x6 s 0 16 O.C. (TYP.) �- 1.5" SO MTL FRAME ----- GRANULE SURFACED FIBERGLASS CAP SHEET ' 3 PLIES TYPE IV FIBERGLASS PLY SHEEP 1" BOND BREAKER TAPE � T MIN. BUTYL SEALANT TAPE BONDED SECURELY TO ' BOTH SURFACES --- --TALL PIPE OR CLOSED PIPE UNE OR SATELLITE DISH BASE MIN. 2 1/2 L.B. LEAD FLASHING SLEEVE - SET PRIMED FLANGE INTO BED OF ROOF CEMENT (4 I.B. LEAD MAY BE REO'D. FOR SOLDERING) 2 STRIPPING PLIES SET IN ASPHALT PLYWOOD DECK FIBERGLASS BASE SHEET NAILED TO DECK OVER ROSIN SLIP SHEET ry 1 W U E- W4 W U r� V J W 1s m > 0 Q ~ x MINIMM., ClEARAN G.E 1.5 X 1.5 X 3 STL ANGLE ANCHOR TO FRAME /STR n W/ 2 -LAG BOLTS EX T&B VLK I IUAL �itU I IUN - BOTTOM OF AWNING FRAME AT FLAT WALL FLUE THRU ROOF DETAIL u MIN. MIN. •GRANULE •SURFACED FIBERGLASS CAP SHEET • 3 PLIES TYPE IV FIBERGLASS PLY SHEET 1" BOND BREAKER TAPE -Y MIN. BUTYL SEALANT TAPE BONDED SECURELY TO BOTH SURFACES -WATER HEATER FLUE 2 STRIPPING RUES SET IN ASPHALT 24 GA. G.I. FLASHING SLEEVE - SET PRIMED FLANGE INTO BED - OF ROOF CEMENT AND STAGGER NAIL FLANGE O 4" O.C. PLYWOOD DECK FIBERGLASS BASE SHEET NAILED TO DECK OVER ROSIN SLIP SHEET N.T.S.1 Q 0 Ir Q wz zQ __jo wz C� - z Q J � W Q T ( 1 co omvm ff np cmm W. Ri eu�uN+c TYPE K -50 FRAME " 0.440 97125 pROM YK 6%X DATE 2/l/97.1 A6. � o � a w VLK I IUAL �itU I IUN - BOTTOM OF AWNING FRAME AT FLAT WALL FLUE THRU ROOF DETAIL u MIN. MIN. •GRANULE •SURFACED FIBERGLASS CAP SHEET • 3 PLIES TYPE IV FIBERGLASS PLY SHEET 1" BOND BREAKER TAPE -Y MIN. BUTYL SEALANT TAPE BONDED SECURELY TO BOTH SURFACES -WATER HEATER FLUE 2 STRIPPING RUES SET IN ASPHALT 24 GA. G.I. FLASHING SLEEVE - SET PRIMED FLANGE INTO BED - OF ROOF CEMENT AND STAGGER NAIL FLANGE O 4" O.C. PLYWOOD DECK FIBERGLASS BASE SHEET NAILED TO DECK OVER ROSIN SLIP SHEET N.T.S.1 Q 0 Ir Q wz zQ __jo wz C� - z Q J � W Q T ( 1 co omvm ff np cmm W. Ri eu�uN+c TYPE K -50 FRAME " 0.440 97125 pROM YK 6%X DATE 2/l/97.1 A6.