HomeMy WebLinkAbout0267.98.27cD rn N O Ln 04 INTERNAL A, UNIT WIRING ME LINE VOLT EXIST. A/C UNIT 24 VAC CONTROL TRANSFORMER. RELAY VATIC DAMPER MOTOR CKT. I 24 VAC. 18 GA. INSULATED B -26 WIRING IN CONTROL PANEL KITCHEN BY E.C. (TYP. FOR KITCHEN LIGHT [:AC ONLY) CKT L � o E 208/240 -3 -60 O KITCHEN LIGHTS CIRCUIT BREAKER HOOD FIRE (TYPICAL) EXTINGUISHER CONTROL PANEL O HOOD O R -1 E LIGHTS ME O /SEE HOOD FIRE PROTECTION SYSTEM WIRING DETAIL 8 /H1. N - DOUBLE POLE KITCHEN LIGHT/ HOOD FAN SWITCH. EF -1 O �n w HVAC UNIT RTS451 TEST STATION CONTROL PANEL / I—APA 451 ANNUNCIATOR SMOKE DETECTORS LOCATED IN SUPPLY AND RETURN AIR DUCTS. WIRED TO SHUTDOWN AC UNITS UPON DETECTION OF SMOKE (TYP.) SUPPLIED BY TACO BELL, INSTALLED BY GC. TO EMS CONTROL RELAY FOR HVAC I 120 -1 -60 CKT. A -15 UNIT POWER I I o l SAMPLING TUBES IN I - SUPPLY AIR DUCT. I I' C R G W1 W2 Y1 Y2 120 -1 -60 CKT. A -15 A/C TERMINAL STRIP O O l SAMPLING TUBES IN RETURN AIR DUCT IF Of 3 m Li m REQUIRED BY CODE. TO TERMINAL STRIP IN EMS INTERFACE PANEL C R G W1 W2 Y1 Y2 EMS TERMINAL STRIP TYPICAL A/C UNIT WIRING DIAGRAM (CONTROLLED BY EMS) N.T.S. 2 0 Lo O w to w CIRCUIT O :•e LINE VOLTAGE WIRING & CONDUIT BY E.C. DOUBLE POLE WALL SWITCH IN WOMEN'S BATHROOM DOUBLE POLE WALL SWITCH IN MEN'S BATHROOM MEN'S ROOM LIGHT WOMEN'S ROOM LIGHT E 120 -1 -60 0 DISC. SWITCH EF -3 WIRING DIAGRAM CIRCUIT O BREAKER WALL SWIT FOR KITCH LIGHT AND ROOM LIGh (TYPICAL) 120 -1 -60 O EF -3 N.T.S.) 3 EF -2 WIRING DIAGRAM COORDINATE THE PLACEMENT OF THE SQUARE DUCT WITH ALL TRADES. TOP OF DUCT ELEV. AT 12' -0" A.F.F. S -2 � 1050 S -1 NOTE: DOUBLE DRIVE THRU OPTION TO BE INSTALLED 8' ON THIS PROJECT SEE DRAWINGS 03 AND 04 FOR LAYOUT AND DETAILS. 100 14 "� RT =1 I, 1 42 "x84" HOOD L� (SEE NOTE #4) GREASE DUCT FIELD FABRICATED. XX AS 9 "x9" GREASE DUCT DOWN TO HOOD. SEE H1 FOR EXACT DUCT LOCATION IN HOOD. 9 "x9" GREASE DUCT UP THRU ROOF TO EF -1. S -1 100 ° E -1 N 100 STEAM HOOD 10 "0 200 CFM STEAM HOOD (!1000 6 "0 200 CFM' t0 "0 S -3 . 75 1 "0 S -4 SUPPLY = 3200 CFM RETURN = 2400 CFM OUTSIDE AIR = 800 CFM NOTES: 1. ALL DUCTWORK SHALL BE EXTERNALLY INSULATED 2. ALL SUPPLY /RETURN ROUND DUCTS SHALL BE RIGID WITH THE EXCEPTION OF THE LAST 5' -0" WHICH CAN BE FLEX 3. SMOKE DETECTOR SHALL BE INSTALLED IN THE SUPPLY AND RETURN AIR PLENUMS AND SHALL DEACTIVATE ROOFTOP UNITS UPON SENSING SMOKE. 4. ENCLOSE ENTIRE GREASE DUCT FROM HOOD TO EF -1 IN FIRE SHAFT. SEE DETAILS 4 /H1 AND 8/A4. 5. ALL EXHAUST DUCTS TO BE RIGID. 6. ALL BRANCH DUCTS FEEDING INDIVIDUAL DIFFUSERS TO HAVE DAMPERS AT TAKE -OFFS FOR AIR BALANCING. N.T.S�4�MECHANICAL -PLAN No E.4 rP 'AV I ON �- MVD (TYP.) u EMS PULLBOX, COORDINATE LOC. & CLEARANCES WITH ELEC. CONTRACTOR AND SHT. E -6 n 10' HOLE THRU SHEAR WALL o i N 6 "0 E -1 100 T 6 "0 n0 4' -0" E -1 20 75 6 "0 RlU- 2x12 E_H. I P TO 8F -2. COMBUSTION AIR VENTS SIZE PER LOCAL CODES SUPPLY = 4000 CFM RETURN = 3100 CFM OUTSIDE AIR = 900 CFM XX AS (2) 14'0 RETURN DUCTS TRANSITION TO 48 "x24" RETURN GRILLE. 1000 10 EXHAUST AIR UP THRU ROOF TO EF -3. 36'x48" STEP DOWN CONCENTRIC DIFFUSER. LENNOX RTD11 -135 SUPPLY AIR & RETURN AIR DUCT FIELD FABRICATED) UP THRU ROOF TO RTU -2. (RETURN GRILLE TO BE HINGED AND FILTER BACKED FOR HEAT i PIPE STORES) VESTIBULE OPTION TO BE INSTALLED ON THIS PROJECT SEE DRAWINGS I 01A AND 01B FOR LAYOUT AND DETAILS. CONCENTRIC DIFFUSER. 28 "x 18' SUPPLY AIR & RETURN AIR DUCT CONNECTIONS. 1/4"= l' -0" r� W F" z H Z V zZ V W a v1 q r� V 11 17 I J � � LLJ m 0 QPE DRAWN BY: Tip CHECKED BY: TH BUILDING TYPE K -5o FRAME JOB NUMBER 97 125 PROTOTYPE ISSUE DATE 2/1/97.1 SHEET NUMBER M2 FN21596.d Q z Ir Q -� W z U� z J W =J —1 Q Q 0 — U z W Q Z rr W Q = o�d 0 Ir U W T � U aEV�IONs DRAWN BY: Tip CHECKED BY: TH BUILDING TYPE K -5o FRAME JOB NUMBER 97 125 PROTOTYPE ISSUE DATE 2/1/97.1 SHEET NUMBER M2 FN21596.d