co rn PLUMBING GENERAL NOTES N 1. INSTALLATION SHALL CONFORM TO THE ENERGY CONSERVATION DESIGN MANUAL STANDARDS FOR NEW o NON- RESIDENTIAL BUILDINGS. 2. CONTRACTOR SHALL VERIFY DEPTH, SIZE, LOCATION OF ALL EXISTING UTILITIES IN FIELD BEFORE Y STARTING WORK. 3. CONTRACTOR SHALL COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER TRADES SO AS TO AVOID UNNECESSARY DELAY OR INTERFERENCES. 4. ALL PLUMBING WORK AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE ORDINANCE & REGULATIONS HAVING JURISDICTION. CONTRACTOR SHALL OBTAIN ALL APPROVALS REQUIRED FROM REGULATING AGENCIES BEFORE STARTING WORK. 5. SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED. 6. ALL PLUMBING WORK & MATERIALS SHALL MEET THE REQUIREMENTS OF THE LATEST EDITIONS OF THE LOCAL PLUMBING CODE, UNLESS OTHERWISE REQUIRED BY THE DEPARTMENT OF BUILDING & SAFETY. 7. CONTRACTOR SHALL FURNISH & INSTALL ALL BACKFLOW PROTECTION DEVICES REQUIRED BY AGENCIES HAVING JURISDICTION. 8. CONTRACTOR PROVIDES CONDENSATE DRAIN FROM A/C UNITS TO APPROVED DRAIN POINT, GAS PIPING TO UNITS AND FINAL CONNECTIONS. 9. OBTAIN AND PAY FOR ALL PERMITS, FEES & INSPECTIONS REQUIRED BY GOVERNING AUTHORITIES. 10. DOMESTIC WATER PIPING: ABOVE GROUND COPPER TYPE "L ". BELOW GROUND OUTSIDE OF BUILDING COPPER TYPE "K ". 11. GAS PIPING: INSIDE BUILDING ABOVE GROUND SCHEDULE 40 BLACK STEEL PIPE. BELOW GROUND OUTSIDE OF BUILDING CLASS 315 SDR 13.5 GAS PIPE. 12. SOIL PIPING: BELOW SLAB INSIDE BUILDING, SERVICE WEIGHT COATED CAST IRON HUBLESS PIPE & FITTING. COPPER TYPE "K ", ABS OR PVC PIPING. MAY BE USED IF APPROVED BY LOCAL CODES. 13. CONDENSATE DRAIN PIPING: COPPER TYPE "M ". 14. INSULATE DOMESTIC HOT /COLD WATER PIPING WITH 1/2" THICKNESS AEROTUBE BY JOHN- MANVILLE PIPE INSULATION, OR APPROVED EQUAL. INCREASE THICKNESS IF REQUIRED TO MEET CODE. 15, REFER TO KITCHEN EQUIPMENT (EQ -1) DRAWINGS FOR PLUMBING ROUGH--IN SCHEDULE & FOR ADDITIONAL WORK TO BE FURNISHED & INSTALLED BY CONTRACTOR. 16. INSTALL SHUT -OFF VALVES ON ALL HOT & COLD WATER LINES. ALL EXPOSED LINES TO BE CHROME PLATED. 17. ALL DRAIN, WATER & GAS LINES SHALL BE KEPT TIGHT TO THE UNDERSIDE OF EQUIPMENT & SECURED IN PLACE. 18. ALL DRAIN LINES FROM PREP LINE TO BE PIPED SEPARATELY TO FLOOR SINK. 19. THE EQUIPMENT ROUGH -INS AS SHOWN ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE. HOWEVER, IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN, THEREFORE, THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE CONTRACTOR TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY ON THE CONTRACTOR. 20. CONTRACTOR SHALL VERIFY THE LOCATION OF THE SANITARY SEWER ON THE SITE PLAN AND SHALL REVISE SEWER SYSTEM AS REQUIRED. 21. REFER TO H -1 & M SHEETS FOR HVAC AND HOOD PLUMBING REQUIREMENTS. 22. ALL DRAINS SHALL BE PROVIDED WITH P- TRAPS. KEY NOTES �l CHOICE OF FLOOR SINK OR HUB DRAIN IS DEPENDENT UPON LOCAL CODE. 1 " GAS LINE FOR FUTURE 0 6" AFF W/ VALVE. �3 1" GAS STUB -OUT FOR RETHERMAUZER, 110,000 BTUH. WITH 3/4" CONNECTION 0 6" AFF. ® 1" GAS STUB -OUT FOR FRYER, 122,000 BTUH. WITH 3/4" CONNECTION 0 6" AFF. 05 1 1/4" GAS UTR TO HVAC UNITS ON ROOF. © PROVIDE WASTE LINES FROM PREP LINE TO FS, 1" AIR GAP MIN. O PROVIDE CONDENSATE LINE & DRAIN LINE FROM ICE MACHINE TO FS. 1 " AIR GAP MIN. ® PROVIDE WASTE LINES FROM BEVERAGE UNIT TO HD /FS, 1 " AIR GAP MIN.. 0 INDIRECT WASTE CONNECTION FOR PREP SINK (S -3) TO FS. 1 " AIR GAP MIN. MAKE DIRECT CONNECTION, IF REQUIRED BY CODE. 10 1" GAS DOWN TO WATER HEATER, 75,000 BTUH. 11 ALL HORIZONTAL CONDENSATE LINES SHALL REMAIN INSIDE THE COOLER BOX AND ONLY BE MOUNTED OUTSIDE FOR ITS FINAL VERTICAL RUN TO THE FLOOR SINK. 12 3/4" COPPER CONDENSATE DRAIN DOWN TO MOP SINK. 1" AIR GAP MIN. 13 3/4" COPPER CONDENSATE DRAIN FROM HVAC UNITS ON ROOF TO SPILL AT MOP SINK. 14 112" CONDUIT ABOVE CEILING TO FUSIBLE LINK IN HOOD. 15 3/8" FIRE EXTINGUISHER PIPE ABOVE CEILING TO HOOD. 16 REMOTE PULL STATION CABLE ABOVE CEILING. 17 ALL DRAIN LINES ON INLET TO GREASE TRAP TO BE CAST IRON OR TYPE "K" COPPER. 18 HORIZONTAL FLUE ABOVE CEILING, COORDINATE INSTALLATION WITH TRUSS WEBBING. DISABLED ACCESS NOTES 1. TOILET FLUSH CONTROLS SHALL BE OPERABLE WITH ONE HAND & SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. CONTROLS FOR THE FLUSH VALVES SHALL BE MOUNTED NO MORE THAN 44" ABOVE THE FLOOR, THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. 2. A CLEAR FLOOR SPACE 30" WIDE BY 48" LONG SHALL BE PROVIDED IN FRONT OF THE LAVATORY TO ALLOW A FORWARDS APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL EXTEND INTO KNEE & TOE SPACE UNDERNEATH THE LAVATORY. 3. HOT WATER & DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACE UNDER LAVATORIES. 4. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND & SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO .ACTIVATE THE CONTROLS SHALL BE NO GREATER THAT 5 LBS /FT LEVER OPERATED. PUSH -TYPE & ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGN, SELF CLOSING VALVES ARE ALLOWED IF THE FAUCETS REMAIN OPEN FOR AT LEAST 10 SECONDS. 5. MIRRORS SHALL BE MOUNTED WITH THE BOTTOM EDGE NOT MORE THAN 40" FROM THE FLOOR. 6. LOCATE HAND DRYER OPERABLE PARTS NOT MORE THAN 40" FROM THE FLOOR 7. LOCATE TOILET TISSUE DISPENSERS ON THE WALL WITHIN 12" OF THE FRONT EDGE OF THE TOILET SEAT. 8. GRAB BARS, FASTENERS & MOUNTING DEVICES SHALL BE DESIGNED FOR 250 LB /LINEAR FT LOAD. PLUMBING FIXTURE SCHEDULE SOIL COLD HOT WASTE WATER ITEM FIXTURE OR VENT I WATER WATER FU FU DESCRIPTION (AMERICAN STANDARD FIXTURE EXCEPT AS NOTED) WASTE WC WATER 4" 2" 1 " -- -- 6 10 AMERICAN STANDARD CADET 17" H EL. 1.6 /FV ELONGATED BOWL, 1.6 GALLON FLUSH VALVE TOILET #3043.102 W /BOLT CAPS 0 1 �a CLOSET w m Q z C) SEAT: AMERICAN STANDARD WAVE #0150.075.020. SLOAN ROYAL FLUSH VALVE #111 1.6 GPF. z I/WC\WATER -- -- AMERICAN STANDARD MADERA AQUAMETER 1.6 /FV ELONGATED BOWL, 1.6 GALLON 2 CLOSET 4 2 1 6 10 FLUSH VALVE TOILET #2234.015 W /BOLT CAPS SEAT: AMERICAN STANDARD WAVE #0150.075.020_ SI OAN ROYAI FI USH VAI VF !Ii 1 1 1 h r,PF UR AMERICAN STANDARD, ALLBROOK #6541.32, VITREOUS CHINA WATER SAVER (1.0 GAL. /FLUSH) SIPHON JET URINAL 1 URINAL 2" 2" 3/4" -- -- 2 5 WITH FLUSHING RIM, 3/4" INLET SPUD, OUTLET CONNECTION THREADED 2" INSIDE, WALL HANGER SLOAN ROYAL 186 -1 FLUSH VALVE. CONTRACTOR TO VERIFY CALIFORNIA APPROVAL OF HANDICAPPED URINAL. L AMLKIUAN 51ANUARU LUCERNE #0.556.015, VITREOUS CHINA, FRONT OVERFLOW. SMITH FLOOR MOUNT LAVATORY 1 LAVATORY 2" 2" 1/2 11 1 /2" 1 1 SUPPORT #700 -16 -Z. FAUCET: AMERICAN STANDARD #6801.000 WITH 0000.372H HANDLES AND FLOW RESTRICTOR SEE DETAIL 7/P3. S -1: INNOVATORS INTERNATIONAL WAL SINK, MODEL WSF 1417 S HAND 2" 2" 112" 1 /2" 1 1 WALL HUNG, INCLUDES A 6" GOOSENECK FAUCET BPSRA E 50-CP INCLUDES: SELF LIR IM COUNTER SINK, TWO T HANDLE SINK 1 GOOSENECK FAUCET, AND BASKET STRAINER. S MOP j,' SINK AND FAUCET SUPPLIED BY OWNER AND INSTALLED BY G.C. 2 SINK 3 2 1 /2 1/2 3 3 (SINK - FIAT MSB2424, FAUCET - CHICAGO #897) S PREP SINK, FAUCET AND DRAIN SUPPLIED BY OWNER AND INSTALLED BY G.C., 3 SINK 2 2 1 /2 1/2 3 3 WATER AND DRAIN LINES SUPPLIED AND INSTALLED BY G.C. (SINK - ADVANCE, FAUCET - CHICAGO) S POT SINK, FAUCET AND DRAIN SUPPLIED BY OWNER AND INSTALLED BY G.C., 4 SINK 2 2 1 /2 1/2$' 3 4 WATER AND DRAIN LINES SUPPLIED AND INSTALLED BY G.C. (SINK - METCRAFT, FAUCET - FISHER) GT GREASE _ _ _ _ _ _ 1 TRAP 4 -- -- -- -- -- -- SEE SITE PLAN FOR GREASE TRAP SIZE AND LOCATION. FS FLOOR JOSAM #49033 CAST IRON FLOOR SINK W /ACID RESISTING PORCELAIN ALL FLOOR SINK BOWLS TO BE PVC EXCEPT AT 1 SINK 3 2 -- -- -- -- 3 -- -- ENAMELED INTERIOR, SEDIMENT BUCKET - "31 ", NIKALOY 3/4 GRATE - "4" RETHERMALIZER AND MINILINES. ALTERNATE WADE NO. W- 9143 -16 -27 SEE DETAIL 1 SHEET #P2 FD FLOOR JOSAM #32123 COATED CAST IRON W /NIKALOY TOP (VANDAL PROOF TOP) 1 DRAIN 3 2 -- -- -- -- 3 -- -- (ALTERNATE WADE NO. W- 1313 -1) SEE DETAIL 2 SHEET #P2. WH WATER RHEEM GLASSLINED WATER HEATER MODEL G76 -75C GAS FIRED, 75,500 BTU /HR INPUT, 75 GAL STORAGE, -- -- -- -- -- -- -- -- -- -- -- -- 4" DIA. VENT THRU ROOF, FIBERGLASS INSULATION, COMB PRESS & TEMP RELIEF,CEC APPROVED. 1 HEATER PIPE FULL SIZE DISCHARGE TO MOP SINK. FCO FLOOR WADE W- 6004 -Z, CAST IRON W /ADJUSTABLE HOUSING, ROUND HEAVY CAST IRON VANDAL PROOF TOP. -- - -- -- -- -- 1 CLEANOUT (ALTERNATE JOSAM NO. 58014 -15) CO WALL _ _- WADE #W- 8480 -R6 & #8550 -E, WITH BRASS PLUG AND ROUND STAINLESS STEEL SECURED ACCESS COVER. -- -- -- -- -- -- - 1 CLEANOUT (ALTERNATE JOSAM NO. 58713) HB HOSE __ __ __ __ 3/4" __ __ __ __ 5 WADE #W- 8604 -89, NON FREEZE W /LOCK BOX GALV. CASING W/ NICKEL BRASS FACE, VACUUM BREAKER. WADE #860OL6, 1 BIBB 175 (L6 =6" STUDWALL), (ALTERNATE JOSAM NO. 71000 -6) HD HUB 3,f 2„ __ __ CAST IRON PIPE HUB INSTALLED FLUSH W /CONC. FLOOR.PROVIDE 1 DRAIN 3 W/ FUNNEL & "P" -TRAP. BFP REDUCED PRESSURE BACKFLOW PREVENTION -- -- -- -- 3/4 „ -- -- - 1 CLA -VAL MODEL RP -2, BRONZE CONSTRUCTION, PIPE RELIEF DRAIN TO EXTERIOR 1 DEVICE NOTES: 1. CONTRACTOR SHALL VERIFY THE LOCATION OF THE SANITARY SEWER ON SITE PLAN AND SH REVISE SEWER SYSTEM AS RD 2. ALL VENTS TO BE 2" UNLESS OTHERWISE NOTED. NOTE: DOUBLE DRIVE THRU OPTION TO BE INSTALLED ON THIS PROJECT SEE DRAWINGS 03 AND 04 FOR LAYOUT AND DETAILS. PLUMBING PLAN 2" GAS ABOVE C GAS MET VERIFY L W /UTILIT' 1 1/2" ( TO COOK SOLENOIC WASTE /GAS 1/4 " =1' -0" • �QZj rn00 C / W pp Eb x W 0 �a w m Q z C) z _Q � W Z CL_ __j W z 0 0 D W 0 Q z Z z J � _z m r� C5 f- U o �wzw� Q W W Z M 5 Q � U U W 00 ry W Q It W I- Y = Z U O r)" > < O Cn r- • DRAWN BY: CHECI�D BY: BUILDING TYPE K -50 FRAME JOB NUMBER 97125 PROTOTYPE ISSUE DATE 2/1/97.01 SHEET NUMBER P1 �QZj rn00 C / W pp Eb x W 0 �a w m Q z Wz dW Q W CL_ __j DRAWN BY: CHECI�D BY: BUILDING TYPE K -50 FRAME JOB NUMBER 97125 PROTOTYPE ISSUE DATE 2/1/97.01 SHEET NUMBER P1 Q 0 ry Q z Wz dW zQ CL_ __j z D (Wry 0 Q z Z z III � m r� Q � U DRAWN BY: CHECI�D BY: BUILDING TYPE K -50 FRAME JOB NUMBER 97125 PROTOTYPE ISSUE DATE 2/1/97.01 SHEET NUMBER P1