GAS METER 1 1/2"
r�\
w U Z v
a cn
1 1/2"
1 1/2"
C' FRYER c
122,000 BTU
FD
1
qn
FUTURE 1
122,000 BTU �
RETHERMALIZER MECHANICAL GAS
RTU -1
235,000
3/4 '
BTU
S
4" VTR
2 2"
FCO
1 FS
1
V
110,000 BTU SHUTOFF VALVE,
/� F
3„ L
G
ANSCO OR HONEYWELL
1 1 /a"
S 1
3 WC 3 1
4" VTR
WATER HEATER
3 2
3
FD
' 1 WC 1
1
GT
75,000 BTU
FS
1
1
WCO
1
WC UR
3
OT
S
i
1
2 FD
1
1
S 1
"
4 3..
4 2 >'
Irm
c
\>
RTU -2
FD
C 1
2
200,000 BTU 1 1/4"
FS
- -
1 �
FS
FCO V 1
1
w e
i3
FD FCO
GAS DEMAND SCHEDULE (X1000)
1 1
m
NOTES;
U
RTU -1 10 TON 235 BTU PIPE SIZED AT 90' FROM
RTU -2 10 TON 235 BTU METER TO MOST REMOTE
1. ALL VENTS TO
BE 2" UNLESS
Q
f-
�
WH -1 75 BTJ OUTLET AND 8" W.0
FRYER 122 BTU
NOTED OTHERWISE
RETHERMALIZER 110 BTU
FUTURE 122 BTU
S
HD 1 A
2. ALL DRAIN LINES
TO GREASE TRAP
TOTAL DEMAND 901 BTU
1
TO BE CAST IRON
"K"
0
OR TYPE COPPER.
(n
Q
0
- -
U
GAS RISER DIAGRAM
N.T.S 3
WASTE DIAGRAM
N.T.S.
1
Q
REDUCED PRESSURE PRINCIPLE
W z
BACKFLOW PREVENTER
W
z Q
METALBESTOS
FLUE CAP
HOT
1 WH
--j
SEE DETAIL 9/A6. ^ ��
2 4
WATER HEATER FLUE - COLD
THRU ROOF -CLASS G
"B"
1
SHUT -OFF VALVE
IN YARD BOX.
0
W
z
SHEET METAL
PARAPET
BOLT TO
GAS VENT
COMB. TdcP RELIEF
U�
z
COLLAR
6" 1. D. PVC
VALVE PER LOCAL
CHASE FROM ABOVE
CEILING WITH 45'
CODE
2--�
STORM COLLAR
STUBOUT
y!
1 1 /2" PIPE DRAIN TO
ROOF FLASHING
3/4"
1 NEAREST FLOOR SINK
m
Q
CLIP ANGLE
FLUSH
CHECK VALVE I
WATER
LJ
(ROOF
CUT WITH
WALL AND FILL
FILTER 1 1/2"
�' FILTER SYSTEM
�� SOV BY PBLG.
t
WITH FOAM. �,,� STUD
Z L
WALL
RUN T &P TO
SEE DETAIL 5/P3 AND 9/P3
co
T
N
a rn
FLOOR DRAIN
-
OVERSIZED
FRAME ROOF
FIN. FLOOR w �j a
V) : o
W/TURNED
DIN ELL yI I
v 3/4„
REVtsaNs
BUCKET
OPENING BY GC
METALBESTOS TYPE "B"
N
0
DOUBLE WALL
WALL SECTION
0
o FULL SIZE DIRT LEG
5
9 O
\
WC
2
NOTE: SEE PLAN
FOR FLUE SIZE AND ROUTING.
3
Lo 3 / 4" DRAIN "AMTROL" THERM- X -TROL
w ST -12 EXPANSION TANK
3
1/4"
4
S `
s UR
1
FLUE THRU ROOF DETAIL N.T.S.
Q
U
PVC SYRUP CHASE
N.T.S.
6
WATER HEATER PIPING N.T.s.
4
1
4 " ,� � 3/4"
O
3/4"
ON LINE SERVING
A
1 /2„ ,, WC 1 /2"
�—
ALIGN W EDGE OF RACK
/
WATER OUTLET:
3/4" COPPER W/
° °
3/4" COLD 1/2" (FOR
CARBO TOR1
v
1 1 2" 1
fWATER
INLET:
3/4" COPPER W/
3"
SHUT -OFF VALVE &
3/4" FPT ELBOW
WATER INLET PLASTIC LINE)
W/ BACKFLOW TO
1/2"
1
1 /2„ I WC 3/4" ✓�
1
L
SHUT —OFF VALVE &
,----OUTLET
2
1
3/4" FPT ELBOW
F G. TOWARDS FLR
FTG. TOWARDS FLR
PREVENTOR POST MIX,
COFFEE, TEA,
1.
3/4" 2 H
1/2" FPT ELBOW
FTG. TOWARDS FLR
2X4 WALL
FCB
'*�_ 3/4" OUTLET
��
14 3/4° 1 /2„
" 1
1 /2
C-4 W/ BACKFLOW
( 3/4"
LAVATORY
PREVENTOR
`n (TO ICE
„
3/4 1 /2
BY: np
WATER OUTLET:
MACHINE)
1 /2"
MW
Q)
1 /2" TO DRINK SY
T.
LC
1/2"
BY: TN
Li
1/2- PLASTIC LINE
1
THERMOSTATIC MIXING VALVE
BUILDING TYPE
�
®
HYDROTEX #HBLO1 (800)922 -9883
Li
K- rJ 0
S ELECTO SYSTEM
CD
94" °
MFS /620 -S WITH SCALE -OUT
FRAME
r
80 3/4"
FLOOR MOUNT UPRIGHT
HIGH FLOW WATER FILTRATION SYSTEM
1/2-
0
5 >,
SUPPORT. SEE SPEC. L/1
P1.
N 2a" CLEARANCE
"WIDE
3/4"
JOB NUMBER
U-
SHEET
1. OVERALL DIMENSIONS 25 1/2 X 9" DEEP X 32" HIGH.
97125
0
w BAG & BOX RACK -�
INTERIOR FACE OF
4x4 WELDED BASE PLATE
2. UNIT SHALL BE SUPPLIED & INSTALLED BY OWNER.
3. ROUGH -INS SHALL BE PROVIDED BY THE CONTRACTOR.
, O T �
I \`i�
PROTOTYPE ISSUE DATE
Q
PERIMETER WALL
W/ (4) 1/2" HILTI KWIK BOLT II.
4. INSTALLATION MUST COMPLY WITH ANY EXISTING STATE OR LOCAL
1 /2•.
1. ALL WATER PIPING
FACE OF ELEC.
PANEL FURRING
OR EQUAL BY G.C.
PLUMBING CODES.
5. THE UNIT MUST BE PROTECTED AGAINST FREEZING.
I SIZES
A D V U S T PIPE PER LOCAL
3/4"
1 A
TO BE OVERHEAD
2/l/97.1
Mo
o FINISH FLOOR
6. USE ONLY TEFLON (HIGH -LOW TEMPERATURE) TAPE TO SEAL THREADED
HB 1 /2"
UNLESS INDICATED.
4 "1
SHEET NUMBER
n (-s-- 39 1 /4"
--
DOPE.
I T REQUIREMENTS 1 2. SAME AS NOTES
�' WALL SECTION
7. DO NOTN INSTALL HERE LINE PRESSURE EXCEEDS 125 PSI OR WHERE
ELEVATION NOTE:
SEE
DETAIL 5/P3
TEMPERATURE EXCEEDS P 100 ING PLAN SHEET P2.
P3
SYRUP RACK
N.T.S.
9
LAVATORY SUPPORT
N.T.S.
WATER FILTER SYSTEM N.T.s.
5
HOT COLD WATER RISER DIAGRAM
N.T.S.
2