HomeMy WebLinkAbout0267.98.40c� u7 CV O I Y vl C4 2 V w U Z H W GAS METER 1 1/2" r�\ w U Z v a cn 1 1/2" 1 1/2" C' FRYER c 122,000 BTU FD 1 qn FUTURE 1 122,000 BTU � RETHERMALIZER MECHANICAL GAS RTU -1 235,000 3/4 ' BTU S 4" VTR 2 2" FCO 1 FS 1 V 110,000 BTU SHUTOFF VALVE, /� F 3„ L G ANSCO OR HONEYWELL 1 1 /a" S 1 3 WC 3 1 4" VTR WATER HEATER 3 2 3 FD ' 1 WC 1 1 GT 75,000 BTU FS 1 1 WCO 1 WC UR 3 OT S i 1 2 FD 1 1 S 1 " 4 3.. 4 2 >' Irm c \> RTU -2 FD C 1 2 200,000 BTU 1 1/4" FS - - 1 � FS FCO V 1 1 w e i3 FD FCO GAS DEMAND SCHEDULE (X1000) 1 1 m NOTES; U RTU -1 10 TON 235 BTU PIPE SIZED AT 90' FROM RTU -2 10 TON 235 BTU METER TO MOST REMOTE 1. ALL VENTS TO BE 2" UNLESS Q f- � WH -1 75 BTJ OUTLET AND 8" W.0 FRYER 122 BTU NOTED OTHERWISE RETHERMALIZER 110 BTU FUTURE 122 BTU S HD 1 A 2. ALL DRAIN LINES TO GREASE TRAP TOTAL DEMAND 901 BTU 1 TO BE CAST IRON "K" 0 OR TYPE COPPER. (n Q 0 - - U GAS RISER DIAGRAM N.T.S 3 WASTE DIAGRAM N.T.S. 1 Q REDUCED PRESSURE PRINCIPLE W z BACKFLOW PREVENTER W z Q METALBESTOS FLUE CAP HOT 1 WH --j SEE DETAIL 9/A6. ^ �� 2 4 WATER HEATER FLUE - COLD THRU ROOF -CLASS G "B" 1 SHUT -OFF VALVE IN YARD BOX. 0 W z SHEET METAL PARAPET BOLT TO GAS VENT COMB. TdcP RELIEF U� z COLLAR 6" 1. D. PVC VALVE PER LOCAL CHASE FROM ABOVE CEILING WITH 45' CODE 2--� STORM COLLAR STUBOUT y! 1 1 /2" PIPE DRAIN TO ROOF FLASHING 3/4" 1 NEAREST FLOOR SINK m Q CLIP ANGLE FLUSH CHECK VALVE I WATER LJ (ROOF CUT WITH WALL AND FILL FILTER 1 1/2" �' FILTER SYSTEM �� SOV BY PBLG. t WITH FOAM. �,,� STUD Z L WALL RUN T &P TO SEE DETAIL 5/P3 AND 9/P3 co T N a rn FLOOR DRAIN - OVERSIZED FRAME ROOF FIN. FLOOR w �j a V) : o W/TURNED DIN ELL yI I v 3/4„ REVtsaNs BUCKET OPENING BY GC METALBESTOS TYPE "B" N 0 DOUBLE WALL WALL SECTION 0 o FULL SIZE DIRT LEG 5 9 O \ WC 2 NOTE: SEE PLAN FOR FLUE SIZE AND ROUTING. 3 Lo 3 / 4" DRAIN "AMTROL" THERM- X -TROL w ST -12 EXPANSION TANK 3 1/4" 4 S ` s UR 1 FLUE THRU ROOF DETAIL N.T.S. Q U PVC SYRUP CHASE N.T.S. 6 WATER HEATER PIPING N.T.s. 4 1 4 " ,� � 3/4" O 3/4" ON LINE SERVING A 1 /2„ ,, WC 1 /2" �— ALIGN W EDGE OF RACK / WATER OUTLET: 3/4" COPPER W/ ° ° 3/4" COLD 1/2" (FOR CARBO TOR1 v 1 1 2" 1 fWATER INLET: 3/4" COPPER W/ 3" SHUT -OFF VALVE & 3/4" FPT ELBOW WATER INLET PLASTIC LINE) W/ BACKFLOW TO 1/2" 1 1 /2„ I WC 3/4" ✓� 1 L SHUT —OFF VALVE & ,----OUTLET 2 1 3/4" FPT ELBOW F G. TOWARDS FLR FTG. TOWARDS FLR PREVENTOR POST MIX, COFFEE, TEA, 1. 3/4" 2 H 1/2" FPT ELBOW FTG. TOWARDS FLR 2X4 WALL FCB '*�_ 3/4" OUTLET �� 14 3/4° 1 /2„ " 1 1 /2 C-4 W/ BACKFLOW ( 3/4" LAVATORY PREVENTOR `n (TO ICE „ 3/4 1 /2 BY: np WATER OUTLET: MACHINE) 1 /2" MW Q) 1 /2" TO DRINK SY T. LC 1/2" BY: TN Li 1/2- PLASTIC LINE 1 THERMOSTATIC MIXING VALVE BUILDING TYPE � ® HYDROTEX #HBLO1 (800)922 -9883 Li K- rJ 0 S ELECTO SYSTEM CD 94" ° MFS /620 -S WITH SCALE -OUT FRAME r 80 3/4" FLOOR MOUNT UPRIGHT HIGH FLOW WATER FILTRATION SYSTEM 1/2- 0 5 >, SUPPORT. SEE SPEC. L/1 P1. N 2a" CLEARANCE "WIDE 3/4" JOB NUMBER U- SHEET 1. OVERALL DIMENSIONS 25 1/2 X 9" DEEP X 32" HIGH. 97125 0 w BAG & BOX RACK -� INTERIOR FACE OF 4x4 WELDED BASE PLATE 2. UNIT SHALL BE SUPPLIED & INSTALLED BY OWNER. 3. ROUGH -INS SHALL BE PROVIDED BY THE CONTRACTOR. , O T � I \`i� PROTOTYPE ISSUE DATE Q PERIMETER WALL W/ (4) 1/2" HILTI KWIK BOLT II. 4. INSTALLATION MUST COMPLY WITH ANY EXISTING STATE OR LOCAL 1 /2•. 1. ALL WATER PIPING FACE OF ELEC. PANEL FURRING OR EQUAL BY G.C. PLUMBING CODES. 5. THE UNIT MUST BE PROTECTED AGAINST FREEZING. I SIZES A D V U S T PIPE PER LOCAL 3/4" 1 A TO BE OVERHEAD 2/l/97.1 Mo o FINISH FLOOR 6. USE ONLY TEFLON (HIGH -LOW TEMPERATURE) TAPE TO SEAL THREADED HB 1 /2" UNLESS INDICATED. 4 "1 SHEET NUMBER n (-s-- 39 1 /4" -- DOPE. I T REQUIREMENTS 1 2. SAME AS NOTES �' WALL SECTION 7. DO NOTN INSTALL HERE LINE PRESSURE EXCEEDS 125 PSI OR WHERE ELEVATION NOTE: SEE DETAIL 5/P3 TEMPERATURE EXCEEDS P 100 ING PLAN SHEET P2. P3 SYRUP RACK N.T.S. 9 LAVATORY SUPPORT N.T.S. WATER FILTER SYSTEM N.T.s. 5 HOT COLD WATER RISER DIAGRAM N.T.S. 2