HomeMy WebLinkAbout0267.98.54co rn u7 N 0 uo 5 R", n 3 0 i which are not to be plastered. B. Protect stucco from deterioration and damage during the remainder of the construction period. 09210.37 GUARANTEE: A. Guarantee all stucco work (interior and exterior) for a period of two (2) years from the dote of acceptance by the Owner. END DIVISION 9 - FINISHES SECTION 09250 GYPSUM BOARD 09250.1 GENERAL 09250.11 RELATED DOCUMENTS A. Drawing, Specification Division 1 and Contract 09250.12 DESCRIPTION OF WORK: A. Types of Work Includes: 1. Gypsum board applied to wood framing and furring. 2. Finishing (joint tape- and - compound treatment). 3. Gypsum board ceiling on direct suspension system. 09250.13 QUALITY ASSURANCE: A. Gypsum Board Standard is GA -216 by Gypsum Association. B. Where gypsum board systems with fire resistance ratings are required to comply with governing regulation, provide materials and installation identical with applicable assemblies which have been tested and listed by recognized authorities. 09250.14 PRODUCT HANDLING: A. Deliver, identify, store and protect gypsum drywall materials to comply with manufacturer's recommendations. 09250.2 PRODUCTS 09250.21 GYPSUM BOARD PRODUCTS: A. Exposed Gypsum Board: Regular type with tapered long edges and thickness of 5/8 except where otherwise indicated. 1.Sheet Size: Maximum length available which will minimize end joints. 2.All Gypsum Board: Type X conforming to ASTM C36 for fire rating. 3.Gypsum Board Installed in Toilet Rooms and Walls Receiving Ceramic Tile: Water- resistant. 4.Gypsum Board Base for Stainless Steel: U.S.G. "Durock." 09250.22 TRIM ACCESSORIES: A. Provide standard trim accessories of types indicated for gypsum board work, formed of galvanized steel, with either knurled and perforated flanges for nailing or stapling, and beaded for concealment of flanges in joint compound. 09250.23 JOINT TREATMENT MATERIALS: A. Type recommended by the manufacturer for the application indicated. B. Joint Tape: Perforated type. C. Joint compound: Ready -mixed vinyl -type for interior use. 09250.24 MISCELLANEOUS MATERIALS: A. Provide auxiliary materials for gypsum board work of the type and grade recommended by the manufacturer of the gypsum board. B. Textured Finish Materials: Latex based texturing material containing fine aggregate; manufactured by U.S. Gypsum. 09250.25 DIRECT SUSPENSION SYSTEM: A. Direct Suspension System: Manufacturers standard zinc- coated system of furring runners, furring tees and accessories designed for concealed support of ceiling. Equal to U.S.G. Co. standard system. 09250.3 EXECUTION 09250.31 GENERAL GYPSUM BOARD INSTALLATION REQUIREMENTS: A. Locate exposed end -butt joints as for from center of wall and ceilings as possible. B. Install exposed gypsum board with face side out. Butt boards together for a light contact at edges and ends with not more than 1/16" open space between boards. C. Locate either edge or end joints over supports. Position boards so that both tapered edge joints abut, and mill -cut or field -cut end joints abut. Stagger vertical joints over different studs on opposite side of partitions. Locate end -butt joints as far as possible from center of wall and ceiling. D. Attach gypsum board to framing and blocking as required for additional support at openings and cutouts. E. Space fasteners in gypsum boards in accordance with referenced standards and manufacturers recommendations. F. Attach gypsum board directly to direct -hung metal support system for ceilings with member spacing 16" o.c. maximum. 09250.32 METHODDS OF GYPSUM BOARD APPLICATION: A. Install exposed gypsum board in single layer application as follows. 1.On paritions /walls over 8' - 1 " apply gypsum board vertically (parallel). 2.On partitions /walls 8' - 1 " less in height apply gypsum board horizontally (perpendicular); use maximum length sheets possible to minimize end joints. 3.On ceilings, apply prior to installation of partitions /walls. B. Where gypsum board is base for thin -set ceramic tile, and in toilet rooms, install water - resistant board. C. Where gypsum board is base for stainless steel, install Durock. D. Apply gypsum boards to supports with screws or nails for walls and screws only for ceilings. 09250.33 INSTALLATION OF DRYWALL FINISHING: A. Apply treatment at gypsum board joints (both directions), flanges of trim accessories, penetrations, fastener heads, surface defects and elsewhere as required to prepare work for decoration. 1.Apply joint tape at joints between gypsum boards, except where a trim accessory is indicated. 2.Apply joint compound in 3 coats (not including prefill of openings in base), and sand between last 2 coats and after last coat. B. Tape joints at water- resistant gypsum board base for ceramic tile, prefinished panels and textured finish. C. Spray apply textured finish where indicated, in accordance with manufacturer's instructions. END DIVISION 9 - FINISHES SECTION 09300 TILE 09300.1 GENERAL 09300.11 RELATED DOCUMENTS; A. Drawings, Specifications Division 1 and Contract. 09300.12 DESCRIPTION OF WORK: A. Tile includes ceramic surfacing units mode from clay or other ceramic materials and includes: 1. Glazed Wall Tile: As specified on drawings. 2. Quarry Tile: As specified on drawings. B. Tile Council of America Standard 137.1 is basis for requirements. 09300.13 QUALITY ASSURANCE: A. Provide products of the following: 1. Glazed Wall Tile: As specified on drawings. 2. Quarry Tile: As specified on drawings. B. Tile Council of America Standard 137.1 is the basis for requirements. 09300.14 PRODUCT HANDLING: I A. Deliver packaged materials and store in onginol containers with seals unbroken and labels intact until time c` use. #272606 -ZXA. Color: Flat white #050. Enamel Underbody" (217)' Finish Benjamin Moore "Satin Impervo Enamel" 09300.15 JOB CONDITIONS: 1.Provide commercial qua lity,hot-dipped galvanized steel body,painted (235). "Porch A. Maintain environmental conditions and protect work during and aluminum cap, stainless steel DX clips, exposed aluminum face pre- F. Equipment Touch Up: Benjamin Moore and Floor Enamel" after installation in accordance with manufacturer's recommendations. finished in manufacturer ?s standard baked enamel white paint finish. (122). G. Shop and Touch Up Primer (Structural Steel): SSPC 15, Type 1, 09300.2 PRODUCTS D. Alternate for regions requiring fire rated suspension systems: red oxide 09300.21 TILE PRODUCTS: USG Interiors, Inc. by Donn with exposed cross runners coped to lay flush No. # 272606 Color: Flat A. Glazed Wall Tile: 4 1/4" x 4 1/4 ". with main runners. -ZXLA white #050. 09900.3 EXECUTION B. Quarry Tile: 1/2" thick of sizes noted on drawings. 1.Provide commercial quolity,hot- dipped galvanized steel body,painted aluminum cap, stainless steel DX clips, exposed aluminum face pre- 09900.31 INSPECTION: C11 W 1. Where shown "Abrasive ", provide manufacturer's standard abrasive- finished in manufacturer ?s standard baked enamel white paint A. Examine areas and conditions under which painting work is to be W W surfaced tile. finish. applied and notify Architect of conditions detrimental to proper and Z E, 04 C. Provide trim shapes of some material and finish as field tile, E. Provide compression post as detailed at seismic zones 3 and 4. timely completion of work. Z x Z t \ and as follows: 1. Base: Sanitary cove units. 09510.23 MISCELLANEOUS MATERIALS: 09900.32 SURFACE PREPARATION: V W � � O 2. Extemal Comers: Bullnose shapes, with a 1/4" radius. A. Provide standard spring steel hold -down clips. A. Perform preparation and cleaning procedures in accordance with C., 09300.22 MORTAR AND GROUT: paint manufacturer s instructions, for each particular substrate v1 A. Latex - Portland Cement Mortar: Latex modified portland cement dry- 09510.3 EXECUTION condition. set mortar. B. Remove and reinstall hardware, hardware accessories, plates, B. Organic Adhesive: Proper type for intended use as certified by 09510.31 INSPECTION: lighting, fixtures, and similar items in place and not to be finish - adhesive manufacturer with primer - sealer where recommended by A. Examine conditions under which acoustical ceiling work is to be painted, or provide surface - applied protection. q manufacturer. performed and notify Architect of unsatisfactory conditions. C. Seal tops, bottoms, and cut -outs of unprimed wood doors with a n 'tti C. Epoxy Adhesive: Two- component epoxy resin and hardener. heavy coat of varnish or equivalent sealer. D. Latex - Portland Cement Grout: Proprietary compound composed of portland cement with latex additive. 09900.33 MATERIAL PREPARATION: 1.Provide product with latex additive which is compatible with latex A. Mix and prepare painting materials in accordance with additive in latex - portland cement mortar. 09510.32 PREPARATION: manufacturer's directions. 2.Colors: As noted on the drawings. A. Establish layout of acoustical units to balance border widths at B. Stir materials before applications to produce a mixture of 09300.3 EXECUTION opposite edges of each ceiling. Avoid use of less- than -half width uniform density, and stir as required during application. units at borders and comply with reflected ceiling plans whenever 09300.31 TILE INSTALLATION STANDARDS: possible. 09900.34 APPLICATION: A. Comply with applicable requirements of the following American A. Apply paint in accordance with manufacturer's directions. Use National Standards Institute standards. 09510.33 INSTALLATION: applicators and techniques best suited for substrate and type of 1.A108.4 for tile installed with organic adhesive. A. Install materials in accordance with manufacturer's printed material being applied. Spray application is recommended for general 2.A108.5 for the installed with dry-set portland cement mortar or instructions, and comply with governing regulations, fire resistance exterior stucco painting. latex - portland cement mortar. rating requirements as indicated, and industry standards applicable to B. Paint surfaces behind movable equipment and furniture same as 3.A108.6 for tile installed with epoxy adhesive, work. similar exposed surfaces. Paint surfaces behind permanently -fixed B. Comply with manufacturer's instructions for mixing and B. Install suspension systems with hangers supported only from equipment or furniture with prime coat. installation of proprietary materials. building structural members. Locate hangers near each end and space C. Finish exterior doors on tops, bottoms and side edges some as 4' -0" along each carrying channel or direct -hung runner, unless exterior faces, unless otherwise indicated. 09300.32 TABLE BASE SETTING STANDARDS: otherwise indicated, leveling to tolerance of 1/8" in 12 -0 ". D. Sand lightly between each succeeding enamel coat. A. Layout core center line locations after floor the is laid and cured. B. Drill cores 3 -1/2" deep into concrete 1.Secure wire hangers by looping and wire- tying, either directly to inserts, E. Apply sufficient time between successive coatings to permit ro slab. structures or to eye- screws, or other devices which are proper drying. C. Remove cores and prepare holes to receive non - shrink setting material. secure. F. Apply first -coat material to surfaces as soon as practical. Setting material should be non- ferrous composition hydraulic cement or non - shrink C. Install edge moldings at perimeter of acoustical ceiling area and G. Apply materials at not less than manufacturer's recommended grout. Approved products and manufacturer's are: 1. "Pourrock" by Minwax "Thorogrip" at locations where necessary to conceal edges of acoustical units. spreading rate. 2. by Thord Systems D. Set top of table support bracket at 27 -3/4" A.F.F. Table top shall be at 1.Attoch moldings to substrate at intervals not over 16" o.c. and not H. Apply one (1) coat of primer (if indicated) and two (2) coats of " A.F.F. more than 3 from ends, leveling with ceiling suspension system to the finish paint or other paint indicated for all items interior and 6 E. E. Fill holes 50% full and install base. Shim and brace posts plumb and level, Allow time tolerance of 1 /8" in 12' -0 ". Miter corners accurately and connect securely. exterior to be pointed. 1.Tint the first finish coat to a shade lighter than the final coat J $ set up per manufacturers instructions. W !� F. After initial set up, remove shims and fill remainder of hole to top of D. install acoustical panels in co- ordination with suspension system, with edges concealed by support of suspension members. Scribe noted on the schedule. I. Perform kitchen touch -up m concrete slab. equipment as necessary. G. Allow 24 hours minimum for supports to cure. Follow set up time per and cut panels to fit accurately at borders and at penetrations. 0 " manufacturer's instruction. 1.Install hold -down clips in all areas. 09900.35 CLEAN -UP AND PROTECTION: U H. Install floor the grout over support setting material. Match color, depth, A. During progress of work, remove from site discarded paint Q g and texture of floor the grout. 09510.34 ADJUST AND CLEAN: materials, rubbish, cans and rags at end of each work day. I- 09300.33 INSTALLATION: A. Clean exposed surfaces of acoustical ceilings including trim, B. Protect work of other tradesman, whether to be painted or not A. Extend the work into recesses and under or behind equipment and edge moldings, and suspension members; comply with manufacturers against damage by painting and finishing work. � fixtures, to form a complete covering without interruptions. instructions for cleaning and touch -up of minor finish damage. C. At the completion of work of other trades, touch -up and restore B. Accurately form intersections and returns. Perform cutting and END all damaged or defaced painted surfaces. drilling of tile without marring visible surfaces. Carefully DIVISION 9 - FINISHES END Q grind cut edges of the abutting trim, finish or built -in items for DIVISION 10 - SPECIALTIES straight aligned surfaces. Carefully grind cut edges of tile abutting SECTION 09900 PAINTING Q trim, finish or built -in items for straight aligned joints. SECTION 10000 BUILDING SPECIALTIES 0 C. Install tile using the following setting beads as shown or 09900.1 GENERAL scheduled. 10000.1 GENERAL 1.Quarry Tile Floors: Dry-set portland cement mortar or latex- 0990.11 RELATED DOCUMENTS: (� Q portland cement mortar over concrete. A. Drawings, Specifications Division 1, Contract. 10000.11 RELATED DOCUMENTS: W Z 2.Glazed Wall Tile: Organic adhesive. 3.Quarry Tile Floors in Cooler: Set A. Drawings, Specifications, Division 1 and Contract. z with epoxy adhesive. 09900.12 DESCRIPTION OF WORK: Q D. Unless otherwise shown, lay the in grid pattern. Align joints A. The extent of work includes painting and finishing of interior 10000.12 DESCRIPTION OF WORK: 0 _ when adjoining tiles on floor, base, walls and trim are some size. and exterior exposed items and surfaces throughout project as A. Building specialties include the following items: _ Q W Layout tile work and center the fields in both directions in each indicated on the drawings. 1. Portable fire extinguishers. Z space. Adjust to minimize tile cutting. Provide uniform oint 1 1.Surface preparation, priming, and coats of paint specified are in 2. Toilet accessories including grab bars, mop rock, and - widths, unless otherwise shown. addition to shop - priming and surface treatment specified under monitor poles. U Z E. Install expansion joints maximum 16 foot o.c. in each direction. other sections of work. 3. Tube for "As- built" drawings. J 09300.33 CLEANING AND PROTECTION: B. Consult drawings to verify items provided by owner and installed _ < A. Upon completion of placement and grouting, clean all tile 09900.13 DELIVERY AND STORAGE: by contractor. W CE surfaces so they are free of foreign matter. A. Deliver materials to job site in original, new and unopened _ U B. Leave finished installation clean and free of cracked, chipped, packages and containers bearing manufacturer's name and label. 10000.13 QUALITY ASSURANCE: broken, unbonded, or otherwise defective the work. A. Provide portable fire extinguisher units conforming with ANSI /UL W (� C. Prohibit foot and wheel traffic from using tiled floors for at 09900.14 JOB CONDITIONS: 711, Q least three (3) day after grouting is completed. D. Cover floors A. Apply water -base paints only when temperature of surfaces to be all tile with Kraft Paper" in all areas and do not painted and surrounding air temperatures are between 50 degrees F (10 10000.14 COORDINATION: remove the paper until final clean -up at completion of construction. degrees C) and 90 degrees F (32 degrees C), unless otherwise permitted A. Coordinate the work with the placement of interval wall by paint manufacturer's painted instructions. reinforcement to receive anchor attachments. END B. Apply solvent- thinned paints only when temperature of surfaces to B. Coordinate locations of the work with other work to avoid T DIVISION 9 - FINISHES be pointed and surrounding air temperatures are between 45 degrees F interference and to assure proper operation and servicing units. (7 degrees C) and 95 degrees F (35 degrees C), unless otherwise REVISKNs SECTION 09510 ACOUSTICAL CEILINGS permitted by paint manufacturers painted instructions. 10000.2 PRODUCTS C. Do not apply paint in snow, rain fog or mist. 09510.1 GENERAL 10000.21 PORTABLE FIRE EXTINGUISHERS: 09510.11 RELATED DOCUMENTS: 09900.2 PRODUCTS A. Dry Chemical Type: UL 299, stainless steel tank, with pressure a /24/4s 2/115/9642 A. Drawings, Specifications Division 1 and Contract 09900.21 COLORS AND FINISHES: gauge; size and classification as indicated on drawings. B. Provide with manufacturer's standard chromed bracket. A. Paint colors, surface treatments, and finishes, are indicated in 09510.12 DESCRIPTION OF WORK: "schedules" on the contract Documents. 10000.22 TOILET ACCESSORIES: A. Extent of each type of acoustical ceiling is shown and scheduled B. Provide finish coats which are compatible with prime paints used. A. Extent of each accessory is indicated on drawings. on drawings and includes: Notify Regional Construction Manager of any anticipated problems using B. Proprietary names are used to designate design and construction 1. Vinyl faced panel ceilings, exposed suspension. specified coating systems with substrates primed by others. of specific products. Similar items of the following manufacturer's 2. Acoustical lay -in panel ceilings, exposed suspension. C. Do not apply paint in snow, rain, fog or mist. are acceptable: 09510.13 QUALITY ASSURANCE: 09900.22 MATERIAL QUALITY: 1. Bobrick 2. Bradley A. Where acoustical ceilings and components of roof or beam A. Products of a single manufacturer are listed but products of one 3. Watrous assemblies are required for compliance with governing regulations, T of the following manufacturers will be accepted so long as they are C. Master key all accessories. provide acoustical materials and application or suspension bearing UL similar in quality and identical in finish (color and texture): Classification Marking for applicable UL design number listed in UL "Fire 1.Benjamin -Moore 10000.23 TUBE FOR "AS- BUILT" DRAWINGS: Resistance Index" 2.Pratt and Lambert A. Provide 6 inch diameter PVC tube with removable caps on each end 09510.14 JOB CONDITIONS: 3.Pittsburgh length to match drawing size. A. Do not install interior acoustical ceilings until space is 09900.23 EXTERIOR PAINT SYSTEMS: B. Provide with two brackets. enclosed and weatherproof, wet -work in space is completed, work above A. Concrete and Stucco: Finish - Benjamin Moore "Moorgard Latex 10000.3 EXECUTION ceilings is completed, and ambient conditions of minimum 60 degrees F House Paint" (103). temperature and maximum 40 percent F humidity are continuously B. Ferrous Metal: Primer - Benjamin Moore "Iron Clad Retardo Rust 10000.3 EXAMINATION: maintained. Inhibitive Paint" (163); Finish - Benjamin Moore " Moorgard Latex House DRAWN BY: TIP Paint" (103). A. Examine substrates and other conditions under which installation CHECKED BY: TH 09510.2 PRODUCTS C. Galvanized Metal: Primer - Benjamin Moore "Iron Clad Galvanized is to occur, and notify Architect of conditions detrimental to proper Metal Primer" (155), Finish - Benjamin Moore "Moorgard Latex House and timely completion of work.DW TYPE 09510.21 CEILING UNITS: Paint" (103). A. Provide United States Gypsum 1/2" x 24" x 48" white stipple shell D. Pavement Markings: Pratt & Lambert "Traffic Paint ". 10000.32 INSTALLATION: K-50 vinyl faced fire code panels with square edge for kitchen and office. E. Masonry. Finish - Benjamin Moore "Moorgio" (096); 2 coats. A. Install accessory and fire extinguisher units in accordance with B. Provide United States Gypsum 3/4 x 24" x 24" #412 Frost manufacturer's instructions, using fasteners which are appropriate to FRAME Acoustone lay -in panels with square edge where shown on the Drawings. 09900.24 INTERIOR PAINT SYSTEMS: substrate and recommended by manufacturer of unit. Install units JOB NUMBER C. Alternate for regions requiring fire rated panels United A. Gypsum Board: Primer - Benjamin Moore "Latex Quick Dry Prime plumb and level, firmly anchored in locations indicated. States Gypsum 3/4 x 24" x 24 #413 Frost Acoustone lay -in Seal" (201); Finish - Benjamin Moore Latex semi qloss enamel (1065). B. Install all items in accordance with manufacturer's instructions, panels with square edge where shown on the Drawings. B. Wood Shelves: Primer - Benjamin Moore Alkyd Enamel Underbody" ANSI A117.1, ADA, and local codes. 97125 (217): Finish - Benjamin Moore Quick Dry Industrial Enamel (071). 09510.22 CEILING SUSPENSION MATERIALS: C. Ferrous Metal (Employee Side): Primer - Benjamin Moore "Iron 10000.33 ADJUST AND CLEAN: PROTOTYPE ISSUE DATE A. Coordinate with other work supported by or penetrating through ceilings, including light fixtures and HVAC equipment. Clad Retardo Rust Inhibitive Paint" (163); finish - Benjamin Moore "Satin Improvo Enamel" (235). A. Adjust units for proper operations and verify that mechanisms function 2/1/97.1 smoothly. B. Type of System: Either direct -hung, or indirect -hung suspension D. Galvanized Metal: Primer - Benjamin Moore "Iron Clad Galvanized B. Clean and polish all exposed surfaces of factory finished units system, at contractor's option. Metal Primer" (155); Finish - Benjamin Moore " Impervo High Gloss after removing protective coatings. SHEET NUMBER C. Exposed Suspension Systems: USG Interiors, Inc. by Donn with Enamel" (133). exposed cross runners coped to lay flush with main runners. No. E. Wood Doors (Employee Side): Primer - Benjamin Moore "Alkyd END SP10