HomeMy WebLinkAbout06070061.25GENERAL NOTES: DESIGN CRI TERM: A. CODES AND STANDARDS. IBC - 2000 B. DESIGN LOADS. ROOF LIVE LOADS. MINIMUM LIVE LOAD: 20 P.S.F. GROUND SNOW LOAD. Pg = 20 P.S.F. SNOW EXPOSURE FACTOR. Ce = 1.0 SNOW THERMAL FACTOR. Ct = 1.0 SNOW LOAD IMPORTANCE FACTOR: 1.0 ROOF DEAD LOADS.• WOOD FRAMING: DECK, INSULA TION & ROOFING = 7.7 P. S F., FRAMING = 5.6 P. S F, MEP/FP = 6.7 P. S F C. WIND LOAD: BASIC WIND SPEED: 90 M.P.H. WIND LOAD IMPORTANCE FACTOR: I = 1.0 WIND EXPOSURE: C NET UPLIFT = 15 P.S.F D. SEISMIC LOAD: MAPPED SPECTRAL RESPONSE ACCELERATIONS: S (0.2 SEC) = 20% .� SEISMIC USE GROUP: 1 S,(1.D SEC) =9.0 SEISMIC DESIGN CATEGORY C SITE CLASS: D BASIC STRUCTURAL SYSTEM. LIGHT BEARING WALL SEISMIC - RESISTING SYSTEM. WOOD SHEAR WALLS RESPONSE MODIFICA 77ON FACTOR. R = 61 (SHEARWALLS) AMPLIFICATION FACTOR. Cd = 4 (SHEARWALLS) ANALYSIS PROCEDURE. • EQUIVALENT LATERAL FORCE PROCEDURE FOUNDA TIONS: DESIGN, 1. THE FOUNDATION HAS BEEN DESIGNED IN ACCORDANCE WITH THE RECOMMENDATIONS MADE IN THE SUBSURFACE EXPLORA71ON REPORT PREPARED BY THE SCHNEIDER CORPORATION DATED OCTOBER 6, 2005. 2. BACKFILLING: B. BACKFILL UNDER FOUNDA71ONS WITH CONCRETE OR AS APPROVED BY SOILS ENGINEER. SPREAD FOOTINGS. 1. ISOLATED & CONTINUOUS FOOTINGS SHALL BEAR ON NATIVE SOILS, APPROVED EXIS17NG FILL, OR NEW CONTROLLED, COMPACTED FILL CAPABLE OF SUSTAINING A NET BEARING PRESSURE OF 2500 P.S.F. UNDER FULL SERVICE LIVE AND DEAD LOADS. 2 TOP OF FOOTING (T/F) ELEVATIONS ARE SHOWN ON 774E PLANS. J. FOOTINGS SHALL BE POURED INTO AN EARTH - FORMED TRENCH U.N.D.. 4. ALL BEARING MATERIAL SHALL BE INSPECTED BY THE GE07ECHNICAL ENGINEER PRIOR TO CONCRETE PLACEMENT. THE GEOTECHNICAL ENGINEER SHALL BE THE SOLE JUDGE AS TO THE SUITABILITY OF THE BEARING MATERIAL. FOOTING ELEVA 71ONS SHALL BE ADJUSTED AS REQUIRED. CONCRETE.• 1. CONCRETE SHALL HAVE A 28 -DAY COMPRESSIVE STRENGTH AND DENSITY, IN ACCORDANCE WI7H THE FOLLOWING. STRENGTH DENSITY MAX WATER/CEMENT SACKS OF CEMENT P.S.I. P.CF RA TIQ AIN PER YARD ALL OTHER CONCRETE U.N.O.: 4000 145 0.48 6 MINIMUM AIR ENTRAINED CONCRETE SHALL HAVE A MAXIMUM WATER / CEMENT RA 770 OF 0.42. 2 REINFORCING SHALL CONFORM TO A.S. T.M. A615, GR. 60, INCLUDING 71ES AND STIRRUPS J. WELDED WIRE FABRIC SHALL CONFORM TO A.S. T.M. A185. 4. ALL REINFORCING SHALL BE DETAILED, FABRICATED AND PLACED, IN ACCORDANCE WITH A.C.I. DETAILING MANUAL 1994 (SP -66). 5. ALL REINFORCING SHALL BE SUPPORTED IN FORMS, SPACED WITH NECESSARY ACCESSORIES AND SHALL BE SECURELY WIRED TOGETHER, IN ACCORDANCE WITH C R.S I. "REINFORCING BAR DETAILING" (1998). 6. MINIMUM CONCRETE COVER, UNLESS N07ED OTHERWISE. A. UNFORMED SURFACE IN CONTACT WITH THE GROUND: 3 IN. B. FORMED SURFACES EXPOSED TO EARTH OR WEATHER: 1. 1 112 IN. FOR 15 BAR OR SMALLER 2• 2 IN. FOR 16 BAR OR LARGER C. FORMED SURFACES NOT EXPOSED TO EARTH OR WEATHER. 1. WALLS, SLABS. 314 IN. 2. BEAMS, COLUMNS (TO TIES OR STIRRUPS) : 1 112 IN. 8. ALL ABUT71NG CONCRETE MEMBERS SHALL BE DOWELED TOGETHER, UNLESS POURED MONOLITHICALLY. DOWELS SHALL BE EQUAL IN SIZE AND SPACING TO THE REINFORCING IN 774E ADJACENT MEMBER. 9. UNLESS OTHERWISE SHOWN, PROVIDE 314" CHAMFERS AT ALL EDGES THAT ARE EXPOSED TO VIEW IN THE FINISHED STRUCTURE 10. SEE ARCHITECTURAL DRAWINGS FOR DOOR AND WINDOW OPENINGS, DRIP SLOTS, REGLE75, MASONRY ANCHORS, PRECAST BEARING LEDGES, BRICK LEDGE ELEVATIONS AND FOR MISCELLANEOUS EMBEDDED PLATES, BOLTS, ANCHORS, ANGLES, ETC. 11. REFER TO ARCHITECTURAL DRAWINGS FOR CONCRETE FINISHES. WHERE FINISH IS NOT SPECIFIED, CONFORM TO REQUIREMENTS OF A.C.I. 301. 12 MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS SHALL BE REFERRED TO FOR DRAINS, SLEEVES, OUTLET BOXES, CONDUIT, ANCHORS, ETC. THE VARIOUS TRADES ARE RESPONSIBLE FOR PLACING THEIR ITEMS 13. LAP SPLICES SHALL BE IN ACCORDANCE WITH THE FOLLOWING TABLE, UNLESS NOTED OTHERWISE. WHERE CLASSES ARE NOT CALLED OUT ON DRA WNGS, USE CLASS "B" SPLICES SPLICES f c = 4000 P. S1., fy = 60,000 P.S.I. TENSION LAP SPLICE FOR TOP BARS, * GRADE 60 CLASS A, B, LAP SPLICE LENGTH (INCHES) Project Team: (c = 3,000 P.S.I. (c = 4, 000 P. S. (c = 5, 000 P. S. I. BAR SIZE CLASS A B A B A B CATEGORY CATEGORY 4 6 4 1 6 4 1 6 4 1 6 -4-T-6 4 4 1 6 13 13 16 21 14 18 13 16 14 17 22 28 19 24 17 22 15 21 27 35 23 30 21 27 16 25 32 42 28 36 25 33 17 30 39 38 50 49 33 33 43 42 30 39 39 38 18 39 51 43 66 56 44 37 57 48 39 33 51 43 19 49 64 48 83 63 56 42 1 72 55 50 38 65 49 110 63 81 58 106 76 70 50 92 65 63 45 82 59 Ill 77 100 71 130 93 86 62 112 80 77 55 101 72 * "TOP BARS" ARE DEFINED AS ANY BAR WITH MORE THAN 12" OF CONCRETE CAST BELOW THE BAR. TENSION LAP SPLICE FOR ALL OTHER BARS, GRADE 60 CLASS A, B, LAP SPLICE LENGTH (INCHES) Project Team: (c = 3, 000 P. S. L f c = 4,000 P.S.I. (c = 5, 000 P. S, I. BAR SIZE CLASS A B A 8 A B CATEGORY 4 6 4 1 6 4 1 6 4 1 6 4 1 6 4 6 13 ANCM BOLT 13 16 12 16 12 16 1 am 17 22 15 19 13 17 15 POST KkM 21 27 18 23 16 21 1 AT 25 32 22 28 19 25 17 GALWAUM 30 29 39 38 26 25 33 33 23 23 30 29 18 HERDR m 39 33 51 43 34 29 44 37 30 26 39 33 19 49 37 64 48 43 32 56 42 38 29 50 38 110 m9afT 63 1 45 1 81 1 58 1 54 1 39 1 70 1 50 49 35 63 45 Ill ROW 77 1 55 1 1001 71 1 67 1 48 1 86 1 62 60 43 77 55 NOTES, 1. TABLES ARE BASED ON C. R. S 1. CATEGORIES 4 AND 6. WHEN SPACING IS LESS THAN 6 BAR DIAMETERS CENTER TO CENTER AND /OR CONCRETE COVER IS LESS THAN ONE BAR DIAMETER, USE CRS! TABLES WITH APPROPRIATE CRSI CATEGORIES WHERE MINIMUM SPACING IS 6 BAR DIAMETERS CENTER TO CENTER AND WHERE MINIMUM CONCRETE COVER IS ONE BAR DIAMETER USE CATEGORY 6 FOR LONGITUDINAL BARS IN BEAM, COLUMNS AND INNER LAYER OF WALL OR SLABS; USE CATEGORY 4 FOR ALL OTHER BARS 2. ALL SPLICES TO BE CLASS "B" TENSION SPLICE UNLESS OTHERWISE NOTED. J. SPLICE PLAIN WELDED WRE FABRIC BY LAPPING ONE FULL MESH SPACE PLUS 2 INCHES I& FILL SLABS INDICATED ON THE DRAWINGS SHALL BE REINFORCED WITH 6x6- W1. 4xW1. 4 W.W.F., UNLESS NOTED OTHERWISE SEE ARCHITECTURAL DRAWINGS FOR PLAN DIMENSIONS, THICKNESSES, SLOPES TO DRAIN, ETC. 19. REINFORCE ALL CONCRETE NOT OTHERWISE SHOWN WITH THE SAME STEEL AS IN SIMILAR SEC71ONS OR AREAS 20. WERE REINFORCING 1S NOT INDICATED OR DEFINED, INCLUDE FOR BID PURPOSES ONLY: A. WALLS. 15 EACH WAY EACH FACE. SPACING IN INCHES = 140 1(WALL THICKNESS IN INCHES) BUT NOT OVER 18 o.c. B. BEAMS. • 2 -19 CONTINUOUS TOP AND BOTTOM FOR EACH 100 SQUARE INCHES OF BEAM CROSS SECTIONAL AREA AND 14 STIRRUPS SPACED AT a OF BEAM DEPTH FULL LENGTH OF BEAM. C. PILASTERS & PEDESTALS. • 1 -18 VERTICAL PER 50 SQUARE INCHES OF CROSS SECTIONAL AREA AND 13 77ES ®6 o. c. D. STRUCTURAL SLABS. 15 EACH WAY TOP AND BOTTOM. SPACING IN INCHES = 100 1(SLAB THICKNESS IN INCHES) BUT NOT OVER 18 "o.c. ON SHOP DRAWINGS, INDICATE ABOVE REINFORCING AS "PER GENERAL NOTES" SUCH REINFORCING MAY BE REVISED OR RELOCATED BY STRUCTURAL ENGINEER DURING SHOP DRAWING REVIEW. 21. PROVIDE CONCRETE EQUIPMENT PADS, INERTIA BASES AND CURBS AS NOTED ELSEWHERE IN CONTRACT DOCUMENTS UNLESS NOTED, DOWEL PADS WITH 14 x O' -6" PROJEC71NG 3" FROM CONCRETE BELOW AT 18 "o.c. EACH WAY. REINFORCE PADS WITH ,18 EACH WAY TOP AND BOTTOM. STRUCTURAL STEEL: 1. STEEL SHALL CONFORM TO THE FOLLOWING GRADES. ALL WF (U.N.O.). A572 GRADE 50 (FY =50 ALL ANGLE, BASE PLATES, CONN. PLATES (U. N. 0.): A36 (FY=36) STRUCTURAL PIPE. A53 (FY=35) STRUCTURAL TUBE. A500 GRADE B (FY=46) 2 ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE A.I.S C CODE OF STANDARD PRACTICE (1992), EXCEPT AS MODIFIED IN THESE N07ES AND THE PROJECT SPECIFICA 71ONS J. CONNEC77ONS MAY BE BOLTED OR WELDED. THE FABRICATOR IS RESPONSIBLE FOR THE DESIGN, OF CONNECTIONS NOT DESIGNED ON THE DRAWINGS GENERALLY, CONNECTIONS SHOWN ON THE DRAWINGS ARE SCHEMA71C AND ARE ONLY INTENDED TO SHOW THE RELA 77ONSHIP OF MEMBERS CONNECTED. ANY CONNEC7ON THAT IS NOT SHOWN OR IS NOT COMPLETELY DETAILED ON THE DRAWINGS SHALL BE DESIGNED BY THE FABRICATOR. 4. STEEL LINTELS A. LOOSE LINTELS FOR BRICK VENEER SHALL BE THE FOLLOWING UNLESS N07ED 07HERWISE, ONE ANGLE (LLV) PER 4" WIDTH OF MASONRY.• L i = L3 -1 120-1 12x 5116 FOR SPANS LESS THAN 4' -11 " L2 = L5x 3 -1 12x 5116 FOR SPANS BETWEEN 5' -0" AND 7' -11" L3 = L6x 3 -1 12x 5116 FOR SPANS BETWEEN 8' -0" AND 9' -11" L4 = L7x 4x 318 FOR SPANS BETWEEN 10' -0" AND 12' -11" B. EXTERIOR LINTELS WHETHER LOOSE OR ATTACHED TO THE STRUCTURE SHALL BE PRIME PAINTED C. CONTRACTOR SHALL COORDINATE WITH THESE DRAWINGS AND DOCUMENTS OF OTHER DISCIPLINES FOR OPENINGS D. LOOSE LINTELS FOR BRICK VENEER SHALL HAVE 4" MINIMUM BEARING U.N.O. 1. BEARING ENDS OF RADIUSED LINTELS SHALL BE CONTINOUS, FLAT & HORIZONTAL 5. SPLICING OF STEEL MEMBERS, UNLESS SHOWN ON THE DRAWINGS, IS PROHIBITED WITHOUT WRITTEN APPROVAL OF THE ARCHITECT. 6. ANCHORS TO CONCRETE AND MASONRY A. HOLDOWNANCHORS SHALL BE ADHESIVE ANCHORS, ALL OTHER ANCHORS SHALL BE CAST -IN -PLACE OR EXPANSION BOLTS B. ADHESIVE ANCHORS SHALL BE HIL77 HIT HY ADHESIVE ANCHORS OR APPROVED EQUAL. USE HY 150 ADHESIVE WHEN ANCHORING INTO SOLID BASE MATERIAL. USE HY 20 ADHESIVE PLUS A SCREEN TUBE WHEN ANCHORING TO OR THROUGH HOLLOW BASE MATERIAL. ANCHORS SHALL BE PLAIN, UNCOATED EXCEPT PROVIDE GALVANIZED ANCHORS WHERE SUPPORTED ITEM IS GALVANIZED. C. WHEN INSTALLING ANCHORS, DO NOT CUT EXISTING REINFORCING. INSTALL ANCHORS TO ACCOMMODATE THE STANDARD HOLE SIZE IN STEEL. D. ADHESIVE ANCHOR EMBEDMENT DEPTH SHALL BE AS FOLLOWS, U.N.O. THE STANDARD HOLE SIZE IN STEEL. f" ? 5e" EMBED. T" ? : 6f" EMBED. n" ? 5T " EMBED. B" ? 10" EMBED. b" ? 116" EMBED. 1" ? 12f" EMBED. 13 EXPANSION BOLTS. UNLESS NOTED OTHERWISE, EXPANSION BOLTS SHALL HAVE THE FOLLOWING MINIMUM SERVICE LOAD CAPACITIES WHEN DRILLED INTO CONCRETE WITH A MINIMUM DESIGN STRENGTH OF 3500 P.S.I. SERVICE LOAD CAPACITIES SHALL PROVIDE FOR A MINIMUM FACTOR OF SAFETY = 4. DIAMETER SHEAR TENSION 1/2" 2400 LBS 2400 LBS 518" 3290 LBS 38400 LBS 314" 4800 LBS 5100 LBS WOOD: 1. ALL FRAMING LUMBER SHALL BE STRESS GRADED DOUGLAS FIR/LARCH OR SOUTHERN PINE FRAMING LUMBER SHALL CLEARLY EXHIBIT A NATIONALLY RECOGNIZED GRADE STAMP. SOUTHERN PINE LUMBER SHALL BE KILN -DRIED TO A MOISTURE CONTENT OF 15% OR LESS FRAMING LUMBER MINIMUM DESIGN VALUES USE GRADE E PSI STUDS 4th FLOOR STUD 1,200,000 JOISTS, RAFTERS i 1,800,000 BUILT -UP MEMBERS 1 1,800,000 2. ALL METAL CONNECTORS, NAILS AND BOLTS LEFT EXPOSED TO THE WEATHER SHALL BE HOT DIPPED GALVANIZED OR CORROSION RESISTANT METAL. 3 LIGHT GAGE TIMBER CONNECTORS INDICATED ON DRAWINGS ARE NOTED USING THE NOMENCLATURE OF THE "STRONG - RE" CONNECTOR MANUFACTURED BY THE SIMPSON COMPANY. CONNECTORS BY OTHER MANUFACTURERS MAY BE USED PROVIDED THE LOAD CAPACITY EQUALS OR EXCEEDS THE CONNECTOR SPECIFIED. INSTALL CONNECTORS ACCORDING TO MANUFACTURERS RECOMMENDATIONS. IONS 5. BOLTS/NUTS LISTED IN 71MBER CONNECTIONS SHALL CONFORM TO A.S T.M. A30Z PROVIDE STEEL WASHERS UNDER NUT AND BOLT HEAD IN CONTACT NTH WOOD. WASHERS SHALL CONFORM TO N.D.S. REQUIREMENTS FOR TYPE OF CONNECTION. 6. FASTEN WOOD WOOD MEMBERS WITH "COMMON" NAILS IN ACCORDANCE WITH LOCAL BUILDING CODE SCHEDULE UNLESS OTHERWISE DETAILED OR NOTED ON THE DRAWINGS SINKERS, COOLERS, AND OTHER TYPES OF NAILS INCLUDING POWER DRIVEN NAILS, NOT PERMITTED WITHOUT PRIOR APPROVAL FROM ENGINEER. Z ALL STRUCTURAL WOOD PANELS SHALL BE APA RATED SHEATHING OF THE FOLLOWING GRADES AND SPAN RATINGS.• ROOF SHEATHING: EXPOSURE 1, SPAN RA 71NG 32116, 19132 NOMINAL THICKNESS WALL SHEATHING: EXPOSURE 1, SPAN RA 71NG 32116, 7116" THICKNESS 8 ALL WOOD MEMBERS IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED WITH A PRESERVA71 VE TREATED LUMBER CUT IN FIELD TO HAVE CUT ENDS DIPPED IN A COMPA71BLE PRESERVATIVE 9. UNLESS OTHERWISE NOTED ON THE DRAWINGS, FASTEN ROOF AND WALL SHEATHING TO SUPPORTING MEMBERS WITH 8d COMMON NAILS SPACED 6" O. C. ALONG PANEL EDGES AND 12" O.C. AT INTERMEDIATE SUPPORTS INSTALL SOLID WOOD BLOCKING BEHIND ALL EXTERIOR WALL PANEL JOINTS 12 WOOD SILL PLATES ANCHORED TO CONCRETE OR MASONRY SHALL HAVE n" DIAMETER ANCHORS LOCATED WITHIN 1' -0" OF EACH END AND SPACED A MAXIMUM OF 4'4" O.C. BETWEEN. ALL FASTENERS IN CONTACT OR PENETRATING TREATED LUMBER TO BE HOT DIPPED GALVANIZED OR STAINLES STEEL. PREFABRICATED WOOD TRUSSES. 1. ROOF TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH TRUSS PLATE INSTITUTE (TPI) DESIGN SPECIFICA71ON FOR METAL PLATE CONNECTED WOOD TRUSSES AND 714E NATIONAL DESIGN SPECIFICATION FOR ANSI/NFOPA WOOD CONSTRUCTION. PROVIDE TEMPORARY AND PERMANENT BRACING ON ALL TRUSSES AS REQUIRED TO PROVIDE MEMBER AND TRUSS STABILITY. 2 ROOF TRUSSES AND THEIR CONNEC71ONS SHALL BE DESIGNED AND CONSTRUCTED FOR A MAXIMUM LIVE LOAD DEFLECTION OF L1360 AND A MAXIMUM TOTAL LOAD DEFLEC7ION OF L1240 AND TO SAFELY SUPPORT THE FOLLOWING LOADS.• A. TOP CHORD LIVE LOAD ............... 20 PSF B. TOP CHORD DEAD LOAD ...............10 PSF C. TOP CHORD NET UPLIFT ................12 PSF D. BOTTOM CHORD LIVE LOAD ............ 24PSF (AT WALKWAYS ONLY) E BOTTOM CHORD DEAD LOAD ............13 PSF F WIND LOADS IN ACCORDANCE WITH THE APPROPRIATE BUILDING CODE GABLED END TRUSSES SHALL HAVE VER 71CAL MEMBERS SPACED AT 16" O. C. MAXIMUM. G OVERBUILD FRAMING FORMING VALLEYS AND HIPS ON ROOF. H. DRIFTED SNOW LOADS IN ACCORDANCE WITH THE APPROPRIATE BUILDING CODE 3. PROVIDE FRAMING ANCHORS AT ENDS OF ALL ROOF FRAMING MEMBERS TO RESIST UPLIFT LOAD AT EACH BEARING POINT. 4. NO FIELD MODIFICATION OF TRUSS IS PERMITTED UNLESS FABRICATOR PROVIDES CALCULATIONS AND DRAWINGS DETAILING THE MODIFICATIONS CALCULA 7IONS AND DRAWINGS SHALL BE SIGNED AND SEALED BY PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF THE PROJECT. 5. SUBMITTALS SHALL INCLUDE THE FOLLOWING. A. SHOP DRAWINGS PREPARED UNDER THE SUPERVISION OF, AND SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF 774E PROJECT, INDICA71NG SPECIES, SPECIES GROUP, SIZES, AND STRESS GRADES OF LUMBER TO BE USED; PITCH, SPAN, CAMBER, CONFIGURATION, AND SPACING FOR EACH TYPE OF TRUSS REQUIRED, TYPE, SIZE, MATERIAL, FINISH, AND LOCATION OF METAL CONNECTOR PLATES, AND BEARING DETAILS SHOW TRUSS LAYOUT AND ALL REQUIRED TEMPORARY AND PERMANENT BRACING AFFEC71NG THE STRUCTURAL CAPACITY OF THE TRUSSES. B. PROVIDE COMPLETE ENGINEERING DESIGN CALCULATIONS, INCLUDING DESIGN VALUES, DESIGN LOADS, ASSUMED ALLOWABLE STRESSES, AND OTHER INFORMA 71ON NEEDED FOR REVIEW THAT HAVE BEEN SIGNED AND SEALED BY A QUALIFIED PROFESSIONAL ENGINEER RESPONSIBLE FOR THEIR PREPARATION, REGISTERED IN THE STATE OF 714E PROJECT MISCELLANEOUS: DESIGN DRAWINGS SHOW THE INTENT OF REQUIRED CONSTRUCTION AND SPECIFIC CONSTRUCTION AS NEEDED TO FACILITATE CLEAR DETAILING. FOR SPECIFIC CONDITIONS NOT SHOWN, THE CONTRACTOR SHALL PROVIDE DETAILS OF CONSTRUCTION SIMILAR TO THOSE SHOWN. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONS PRIOR TO COMMENCING WORK NOTIFY THE STRUCTURAL ENGINEER IN WR171NG OF DISCREPANCIES OR CONTRADICTIONS ENCOUNTERED PRIOR TO EXECTU71NG ANY EFFECTED CONSTRUCTION. 2. THESE DRAWINGS ARE INTENDED TO BE USED WITH DRAWINGS OF OTHER TRADES CONTRACTOR IS RESPONSIBLE FOR COORDINATING SUCH REQUIREMENTS INTO THEIR SHOP DRAWINGS AND WORK. AREAS OF CONSTRUCTION NOT OTHERWISE DETAILED SHALL BE DETAILED AS IN SIMILAR AREAS OR CONDITIONS 4. NO OPENING SHALL BE MADE IN ANY STRUCTURAL MEMBER WITHOUT THE WRITTEN APPROVAL OF THE ARCHITECT. THE CONTRACTOR 1S RESPONSIBLE FOR LIMITING THE AMOUNT OF CONSTRUCTION LOAD IMPOSED UPON STRUCTURAL FRAMING. CONSTRUCTION LOADS SHALL NOT EXCEED THE DESIGN CAPACITY OF THE FRAMING AT THE TIME THE LOADS ARE IMPOSED. 8. THE STRUCTURE IS DESIGNED TO FUNC71ON AS A UNIT UPON COMPLETION. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND /OR SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND /OR SEQUENCES 7. 10. DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS 12 THE CONTRACTOR SHALL INFORM THE ARCHITECT IN WRITING OF ANY DEWA7101V FROM THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL NOT BE RELIEVED OF THE RESPONSIBILITY FOR SUCH DEVIATION BY THE ARCHITECT'S APPROVAL OF SHOP DRAWINGS, PRODUCT DATA, ETC, UNLESS HE HAS SPECIFICALLY INFORMED THE ARCHITECT OF SUCH DEVIATION AT THE 71ME OF SUBMISSION, AND THE ARCHITECT HAS GIVEN WRITTEN APPROVAL TO THE SPECIFIC DEMARON. 13. ALL THINGS WHICH, IN 774E OPINION OF THE CONTRACTOR, APPEAR TO BE DEFICIENCIES, OMISSIONS, CONTRADICTIONS, OR AMBIGUITIES, IN THE PLANS AND SPECIFICA 71ONS SHALL BE BROUGHT TO THE ATTEN7101V OF THE ARCHITECT. PLANS AND /OR SPECIFICATIONS WILL BE CORRECTED, OR WRITTEN INIERPRETA7101V OF THE ALLEGED DEFICIENCY, OMISSION, CONTRADICTION OR AMBIGUITY WILL BE MADE BY THE ARCHITECT BEFORE THE EFFECTED WORK PROCEEDS. 14. CHECK ALL DIMENSIONS AGAINST REQUIREMENTS OF OTHER CONTRACT DOCUMENTS FIELD VERIFY DIMENSIONS RELATING TO EXISTING CONDITIONS PRIOR TO ORDERING MATERIALS AND FABRI CA 710N. 17. NO MODIFICATION, ALTERATION OR REPAIR SHALL BE MADE WITHOUT PRIOR REVIEW BY THE ARCHITECT. SUBMIT DETAILS AND CALCULATIONS PREPARED BY A PROFESSIONAL ENGINEER REGISTERED IN STATE WHERE PROJECT IS LOCATED AND EMPLOYED BY CONTRACTORS. STANDARD SWW7UWL A61BR£MATJbMS 319 North 4th Street Suite 1000 St. Louis, MO 63102 ,nbaiM J14/k71 --959= Ax Ilf/�71 -tiros Project Team: ADMDUr AM ExlEm W CUMEFACE aF: ADBDOGAL AM. FAR FACE F.F. FlxRHOUISE PA ARiE W AMR FMB! AIL PLAN r ALHN/�RHII ALLK RIME FLOOR LEM3 FFL PU10 Ric ANCM BOLT AR FiMSiH FLOOR SLAB FFS PL yM PW AND A am R. BAST CQVCfffE P.C: ANRF r FDOW FM POST KkM P.T. AROVIECP W ARM FMNMMM FM PIIBMDID JWT FUM RAF AT • FRAiBYIG Flm RADIUS RAa BASOM OW. GALWAUM my AM ANY" REr;T BASE RAW a r GAUGE CA. 1119MEHCE Rff. BEAU AL mt91AL CONDOAcm CC. HERDR m AE FAILS BUS 011011P OR 93000M CONCH W RC BEAM on GRADE at 111130awn AMF Or BARD ED. GG"MN � Dom our m9afT HK RIE1LSbN NEW ROM W NRf Farr HA AMR It BOTTOM OF FMfNG B^ HOt1OI CORE HC ROW W. BOT= aF MLL 19 HOi1M11TA! HOB AM fN BRmIr 1011 WEAL Mail FACE hu.. SCNOULE SAD, BRlDl 1HC 81110111 NSVE FACE LF S 15CM SECT Sam BLOC NHEw W. SEAR CAV ECRW at CAST N PACE MR JWT JL SEAR RILL 9LE CATEGORY CAT. JOST JSr SHORT MY at CEILM as W - TOOO ba x SKAIR AL amvr ML HNao001fT No SLAB SL 03M LINE r FQID s SLAB all OW S.O.G. cam TD aENIEIt c/C UafT NEI NT LT. K SFAC& 9si1 K SRAM SPA CLEW dd.. LNK LA. SPECFEIAOILS 9 CONCEW CONC. LK LOAD LL Sam Sp, COLM COL LAE LOAD LL STAMMO SM 036A M111011111 Cm DRANK Low STEEL SR. OOIfSA11111c V Cffl= LONG LEG HHUMaXTAL L LIL SHRUCRAE OR SMUCRAK SIRUC CIONS N CADU JWT Gd LOW LEG; MORIHCAL LLK SLFFW suppr ComlUm CORT. LM MY LE SrA EBIIP•N. SHK CONMACMR CONTR LOW PONT L.P. INS MESS AK DEAD LOAD DL ALWACRAU7f im TOP OF FWNW TF. DEiorc Ax Aw 1K MP OF T/ DE R EW DIP. MASMW HAS NP OF CDAEAEW fYjj�C DETAL DET MAX RY GROW 1La MP or ASr T/J DLAGt K DIAL MATERIAL UATz XF OF LEDW ?A DGANETFR r MA7iRAf MAX 1OP aFSLAB H sT� rT/SL DONI.S Drs &7AL ML EP OF � fw DOM DILL MED Sm TLS READ T. DRAW= DOM MIMHiI MILL T1FT_t Ttp. EACH EA 1mc11AIIEDUS Me-, L#ILESS NOTED 0*113 T: fLIG,a MOO FAGS E.F. MOim C110111119CM 1LG Wpm BAN" Ka EACH My EE WM FACE IF MSRA" IERT ETiCTAT.AL ELECT NLMK NML 119MCAL EACH FACE KEF. ELEM EW EL N17T N CONWACT KLC. ■N BRACE MR EIEMINSR ELEK NOT TD SCALE ITS NElOLD ■RE FAMW EEF. EOIbU. ED aN a7111}]R aG MW EaNrExr EOUP. aP8= GPM KNOUT Ell ENS= aw.. OPPOSTfE CEP. MIEN SHP DFANSW JWT EA OPPO9fE HAND OFR IL NE01T III 1[[ 1 [if 6B0UP ARCHITECTS Austin Carolinas Denver New York St. Louis: 319 North 4th Street Suite 1000 St. Louis, MO 63102 ,nbaiM J14/k71 --959= Ax Ilf/�71 -tiros Project Team: General Padc Corporation Contractor 1001 Boardwalk Springs Place O'Fallon, MO 63366 P4638) 581 -9500 Fw4638) 581 -9501 Civil The Schneider Corporation Engineer 8901 Otis Avenue Indianapolis, IN 46216 Ph4317) 828 -7100 Foy 0l7) 828 -7200 Electrical Bell Electrical Contractors Design 128 Millwell Drive Engineer Maryland Heights, MO 63043 84314) 739 -7744 FOX014) 739 -M7 Plumbing Tennill and Associates Design 177 Chesterfield Industrial Engineer Blvd. Chesterfield, MO 63005 P#4638) 537 -3999 F *&M) 537 -3998 Structural Alper Audi, Inc Engineer 1804 Borman Circle Drive St. Louis, MO 63146 Pk J314) 432 -MM Fwt(314) 432 -MM Professional Seal: M � The Rd &W kdAwfs wd d and 1n'9h 9hW q*W a* to th• moterlol wW bm shown on ft dw L All aiwa bstrurroft or dh.► doesmsna rwt =MWq int. s.ol *4 not be oom�d.r.a prsposd by We a irircl. ad ft ad,rNd wprowl cn OW co for amh atei shad or >111111 Cd O C L C Cd O -a-P LM 4m+ 3 _� C Cd Cl) _0 CE1 �- C ■� 70 0 U C U 0 0 W OD C � L L. 10 a- This drawing and details on it are the sole property of the architect and may be used for this specific project only. It shall not be loaned, copied or reproduced, in whole or in part. or for any other purpose or project without the written consent of the architect. No. Revision Description Date Sheet Title: GENERAL STRUCTURAL NOTES Project Number Sheet Number: 05267 Drawn y: BB, KP Issue Date: A8003 June 1, 2006