HomeMy WebLinkAboutCS1.215510 CH ILLED WATER P IP ING
.01 INSTALL SYSTEM USING HARD COPPER TYPE "L" PIPE, WROUGHT
COPPER FITTINGS WITH SOLD ER JO INTS .
.02 SOLDER FILLER METALS: ASTM B -32, SILVABRITE 100 (ENGELH.aRD)
95.5 PERCENT TIN, 4 PERCENT COPPER, 0.5 PERCENT SILVER (IR
WATERSAFE (CANFIELD). 95 PERCENT TIN, 4 PERCENT COPPER. "I
PERCENT SILVER.
15891 DUCTWORK
.01 DOWNSTREAM OF VVU BOXES: FABRICATE FROM GALVANIZED SH. _ET
METAL COMPLY WITH ANSI /ASTM A -527, LOCK FORMING QUALITY, WITH
ANSI /ASTM A -525, G90 ZINC COATING. MILL PHOSPHATIZED F( R
EXPOSED LOCATIONS.
FABRICATE DUCTWORK OF GAGES AND REINFORCEMENT COIrPLY IN ,,
WITH SMACNA "HVAC" DUCT CONSTRUCTION STAiCARDS FOR 2"
PRESSURE CLASS.
.02 PROVIDE DUCT LINER, 1 " FIBROUS GLASS COMPLYING WITH THI,.RMAL
INSULATION MANUFACTURER ASSOCIATION (TIMA) AHC -101 AND UL 181
RATED. PROVIDE DUCT LINER IN SUPPLY AND RETURN AS IN) ICATED
ON THE DRAWINGS.
.03 UPSTREAM OF VVU BOXES: MATCH EXISTING DUCT AND F ITT I: CGS .
.04 DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS.
.05 USE FLEX DUCT, WITHOUT SHARP BENDS, ONLY AS FINAL
CONNECTION TO DIFFUSER, MAXIMUM 3' -0" LONG. FLEX DI]T MUST
BE SUITABLE FOR MOUNTING IN A NON- COMBUSTIBLE RETURN
CEILING PLENUM.
15932 AIR OUTLETS AND INLETS
.01 PROVIDE DIFFUSERS. REGISTERS AND GRILLES SIMILAR IN C JAL ITY ,
APPEARANCE, STYLE AND PERFORMANCE TO THE MODEL NUIBERS
INDICATED ON THE DRAWINGS.
.02 ACCEPTABLE MANUFACTURERS:
ANEMOSTAT
BARBER - COLEMAN
KRUEGER
T ITUS
15990 TESTING, ADJUSTING AND BALANCING
.01 QUALIFICATIONS: AN INDEPENDENT FIRM CERTIFIED BY AS ,;OC . AIR
BALANCE COUNCIL (AABC) IN THOSE TESTING AND BALANN,, ING
DISCIPLINES SIMILAR TO THOSE REQUIRED FOR THIS PRO... =CT .
.02 TEST, ADJUST AND BALANCE SYSTEM TO ENSURE PROPE I AIR DUCT
PRESSURES.
.03 TEST, ADJUST AND BALANCE ALL FANS AND VARIABLE SIR VOLUME
UNITS (VVU) TO ENSURE PROPER AIR FLOW SETTNVGS. OPERATE
EACH FAN TO ENSURE PROPER AIR FLOW IN APPROPR IATI .
D IRECT ION.
.04 TEST, ADJUST AND BALANCE ALL FAN COIL UNITS TO `NSURE PROPER
CHILLED WATER FLOW RATE SETTINGS.
.05 PREPARE AND SUBM IT REPORT OF TEST RESULTS, INCL JD ING
INSTRUMENTATION CALIBRATION REPORTS, IN FORMAT
RECOMMENDED BY APPLICABLE STANDARDS.
.06 ENSURE ALL RETURN AIR LIGHT FIXTURES ARE OPEN.
I
15300 FIRE PROTECTION
.01 MODIFICATIONS, DESIGN, AND INSTALLATION SHALL COMPLY WITH,
BUT NOT LIMITED TO, THE FOLLOWING CODES AND AUTHORITIES. IF
CONFLICTS OCCUR BETWEEN THE FOLLOWING AUTHORITIES, OR
OTHERS NOT LISTED, THE MOST STRINGENT SHALL GOVERN:
LOCAL CODES AND ORDINANCES
STATE CODES AND ORDINANCES
NATIONAL FIRE PROTECTION ASSOCIATION
STATE AND LOCAL FIRE MARSHAL
.02 RELOCATE, MODIFY, AND ADD FIRE SPRINKLER HEADS AS REQUIRED
TO COMPLY WITH AUTHORITIES HAVING JURISDICTION.
.03 FIELD ESTABLISH LOCATION OF EXISTING FIRE SPR II:KLER HEADS,
SIZE. ROUTING, AND HEIGHT OF EXISTING PIPING.
.04 PROVIDE FIRE SPRINKLER HEADS AND ESCUTCHEONS THAT MATCH
EXISTING IN AREA OF MODIFICATIONS.
15411 DOMESTIC COLD WATER (CW) AND HOT WATER (HW)
.01 INSTALL SYSTEM USING HARD COPPER TYPE "L" PIPE, WROUGHT
COPPER FITTINGS WITH SOLDER JOINTS.
.02 SOLDER FILLER METALS: ASTM B -32, SILVABRITE 100 (ENGELHARD)
95.5 PERCENT TIN, 4 PERCENT COPPER, 0.5 PERCENT SILVER OR
WATERSAFE (CANFIELD) , 95 PERCENT TIN, 4 PERCENT COPPER, 1
PERCENT SILVER.
15412 DRAINAGE AND VENT PIPING
.01 PIPING SHALL BE SERVICE WEIGHT HUB AND SPIGOT SOIL PIPE AND
FITTINGS WITH ASTM A -74 RUBBER GASKET OR SERVICE WEIGHT "NO
HUB" CAST IRON SOIL PIPE AND FITTINGS WITH C ISP 1 310 -82 HUBLESS
CAST IRON SOIL PIPE COUPLINGS.
.02 COPPER D WV PIPING WITH CAST BRONZE FITTINGS AND SOLDER
JOINTS ACCEPTABLE FOR VENT PIPING.
15440 PLUMBING FIXTURES
.01 PROVIDE PLUMBING FIXTURES AS INDICATED ON THE DRAWINGS.
PLUMBING FIXTURES AND TOILET SEATS SHALL BE WHITE WHERE
APPLICABLE. EXPOSED PIPING AND SUPPLY FITTINGS SHALL BE
CHROMIUM PLATED. WALL PENETRATIONS SHALL BE FITTED WITH
CHROMIUM PLATED ESCUTCHEONS.
PLUMBING FIXTURES SHALL BE AS MANUFACTURED BY AMERICAN
STANDARD OR ACCEPTED EQUAL UNLESS OTHERWISE INDICATED.
.02 WATER CLOSET (WC -1):
A. 2257.103: "AFWALL AQUAMETER" WITH DIRECT -FED SIPHON JET
ACTION, ELONGATED BOWL, OFF -FLOOR MOUNTING (WALL
HUNG), 1 1/2" TOP SPUD, VITREOUS CHINA THAT FLUSHES ON
1.5 GALLONS.
B. 111: SLOAN ROYAL LOW CONSUMPTION QUIET FLUSH VALVE
WITH 1" SCREWDRIVER ANGLE CHECK STOP, ADJUSTABLE
TAILPIECE, VACUUM BREAKER FLUSH CONNECTION, SPUD
COUPLING, WALL AND SPUD FLANGES THAT FLUSHES WITH 1.5
GALLONS PER FLUSH.
C. 1955- SS /C:; BEMIS CONTOURED SEAT, HEAVY DUTY INJECTION
MOLDED, SOLID PLASTIC, OPEN FRONT, LESS COVER,
SELFSUSTA IN ING CHECK HINGES.
D. W -310: WADE SERIES HIGH -ROUGH SINGLE OR DOUBLE
ADJUSTABLE VERTICAL CARRIER FITTING WITH 4" SIDE INLET.
E. W-340: WADE SERIES SINGLE OR DOUBLE ADJUSTABLE
VERTICAL CARRIER FITTING WITH 4" SIDE INLET.
.03 WATER CLOSET (WC -2):
A. SAME AS WC -1 EXCEPT MOUNTED FOR HANDICAPPED USE.
.04 URINAL (UR -1):
A. 6540.017: "ALLBROOK" VITREOUS CHINA WATER SAVER (1.5
GALLONS PER FLUSH) SIPHON JET URINAL WITH FLUSHING RIM,
1 1/4" INLET SPUD, OUTLET CONNECTION THREADED 2" INSIDE
AND WALL HANGER AND MOUNTED FOR HANDICAPPED USE.
B. 180 -1.5: SLOAN ROYAL WATER SAVER QUIET FLUSH VALVE
WITH 1" SCREWDRIVER ANGLE CHECK STOP, ADJUSTABLE
TAILPIECE, VACUUM BREAKER FLUSH CONNECTION, SPUD
COUPLING FOR 1 1/4" TOP SPUD, WALL AND SPUD FLANGES
THAT FLUSHES WITH 1.5 GALLONS PER FLUSH.
C. W -400: WADE SERIES UNIVERSAL HANGER PLATE CARRIER
WITH PIPE UPRIGHTS AND BLOCK BASE FEET.
.05 LAVATORY (LAV -1):
A. 0355.12 "LU�_FRNE" 20" x 18 ", VITREOUS CHINA LAVATORY,
FRONT OVERFLOW, ANTI-SPLASH RIM, CAST IN SOAP DISH, 4"
CENTERS MODIFIED FOR CONCEALED ARM CARRIER.
B. 2238.129: "HERITAGE" LAVATORY FAUCET WITH 4" WRIST
HANDLES, GOOSENECK SPOUT WITH AERATOR.
C. 2167: McGUIRE CHROME PLATED ANGLE SUPPLY WITH 1/2" O.D.
x 12" FLEXIBLE RISER AND 112" IPS x 1/2" O . D . WHEEL HANDLE
STOP WITH ESCUTCHEON.
D. 4429.015 1 1/4" x 1 112" CAST BRASS "P" TRAP, CLEANOUT PLUS,
SLIP INLET, OUTLET TO WALL WITH INSIDE PIPE THREADS.
E. 4446,019 1 1/2" x 6" PIPE NIPPLE THREADED BOTH ENDS, CAST
BRASS ESCUTCHEON, CHROME FINISH.
F. W -520 WADE SINGLE CONCEALED ARM LAVATORY CARRIER
WITH NON -SLIP LOCKING DEVICES.
G. INSULATE DRAIN AND SUPPLY PIPING.
.06 DOUBLE COMPARTMENT STAINLESS STEEL SINK (SK -1):
A. LR -3322: ELKAY DOUBLE COMPARTMENT SINK 18 GAUGE, TYPE
302 STAINLESS STEEL, 7 1/2" BOWL DEPTH, POLISHED SATIN
FINISH, 3/16" DROP LEDGE, SOUND GUARD UNDERCOATING; 3
HOLES.
B. LK -2433: ELKAY HI -ARC 2- HANDLE DECK - MOUNTED FAUCETS,
10" HIGH SWING SPOUT, AERATOR AND WING HANDLES.
C. LK -35: ELKAY STANDARD DUO STRAINER WITH ONE -PIECE
STAINLESS CONICAL STRAINER BASKET WITH NEOPRENE
STOPPER, C.P. BRASS, 1 -1/2" O.D. TAILPIECE, TWO (2) REQUIRED.
D. LK -500: ELKAY 1 -1/2" SATIN CHROME TUBING "P" TRAP WITH
CLEANOUT, WASTE ARM TO WALL AND WALL FLANGE.
E. 2165 -LK: McGUIRE 1/2" BY 3/8" O.D. CHROME PLATED ANGLE
SUPPLY STOP WITH LOOSE KEY STOP, ESCUTCHEON AND 3/8"
FLEXIBLE RISER, TWO (2) REQUIRED.
.07 LAVATORY (LAV -2):
A. COUNTER MOUNTED LAVATORY.
B. FIXTURE, TRIM, AND ACCESSORIES TO MATCH EXISTING
ADJACENT LAVATORIES.
.08 HUB DRAIN (HD-1) : JOSAM SERIES 88210-2" WITH FUNNEL INLET AND
P -TRAP.
15458 WATER HEATER (EWH -1 &2)
.01 PROVIDE ELECTRIC WATER HEATER COMPLETE WITH MOUNTING
SHELF AS INDICATED ON THE DRAWINGS.
.02 HEATER: ENERGY SAVER MODEL, 120 VOLT, SINGLE PHASE, HEAVY
STEEL JACKET, GLASS LINED TANKS, SEPARATE RELIEF VALVE
TAPPINGS, 1500 WATT HEATER ELE .4ENT .
.03 MANUFACTURER /MODEL: LOCHINVAR MODEL JRC006E OR APPROVED
EQUAL.
DIVISION 10
10160 TOILET PART IT IONS
.01 TOILET PARTITIONS: FLOOR MOUNTED METAL UNITS WITH BAKED
ENAMEL FINISH; SANYMETAL ACADEMY SERIES OR EQUAL.
.02 URINAL SCREENS: WALL HUNG METAL UNITS WITH BAKED ENAMEL
FINISH; SANYMETAL TYPE C OR EQUAL.
.03 COLORS: SUBMIT MANUFACTURER'S STANDARD COLORS FOR
SELECTION.
.04 FIELD MEASURE PRIOR TO FABRICATION.
.05 FURNISH INSERTS AND ANCHORAGES WHICH MUST BE BUILT INTO
OTHER WORK.
.06 HARDWARE: FURNISH HARDWARE FOR EACH COMPARTMENT IN
PARTITION SYSTEM, AS FOLLOWS:
A. HINGES; CUTOUT INSET TYPE, ADJUSTABLE TO HOLD DOOR
OPEN AT ANY ANGLE UP TO 90. PROVIDE GRAVITY TYPE,
SPRING- ACTION CAM TYPE, OR CONCEALED TORSION ROD
TYPE, TO SUIT MANUFACTURER'S STANDARDS.
B. LATCH AND KEEPER: MANUFACTURER'S STANDARD
SURFACE - MOUNTED LATCH UNIT, DESIGNED FOR EMERGENCY
ACCESS, WITH COMBINATION RUBBER-FACED DOOR STRIKE
AND KEEPER.
C. COAT HOOK /BUMPER MANUFACTURER'S STANDARD UNIT,
COMBINATION HOOK AND RUBBER - TIPPED BUMPER, SIZED TO
PREVENT DOOR HITTING MOUNTED ACCESSORIES.
D. DOOR PULL: MANUFACTURER'S STANDARD UNIT FOR
OUT-SWING DOORS.
.07 PROVIDE 2' -0" DOOR WIDTHS TYPICAL AND 2' -8" DOOR WIDTHS ON
HANDICAPPED STALLS.
.08 PROVIDE ALL ITEMS FOR A COMPLETE INSTALLATION. INSTALL PER
MANUFACTURER'S RECOMMENDATIONS.
10650 OPERABLE PARTITIONS
.01 SUBMITTALS
A. SUBMIT SHOP DRAWINGS SHOWING LOCATION AND EXTENT OF
OPERABLE PARTITIONS. INCLUDE PLANS, ELEVATIONS, AND
LARGE SCALE DETAILS OF ANCHORAGES, AND ACCESSORY
ITEMS. INDICATE LOCATION OF EACH UNIT WITH BUILDING,
CONDITIONS AT OPENINGS, TYPICAL AND SPECIAL DETAILS,
LOCATION AND INSTALLATION REQUIREMENTS FOR HARDWARE.
B. SUBMIT CERTIFICATE INDICATING THAT SUPPORT FRAMING
SYSTEM HAS BEEN DESIGNED BY AN ENGINEER LICENSED IN
THE STATE OF OHIO.
.02 OPERABLE PARTITION: HUFCOR SERIES 7500.
A. PANELS: TOP SUPPORTED, CENTER STACK, HINGED PAIRS, 3
5/8" THICK PANELS WITH CLEAR ANODIZED TRIM, MECHANICAL
TOP AND BOTTOM SEALS, TACKABLE SURFACE (3/8" PIN DEPTH
MIN.) ENTIRE AREA COMPOSED OF CORK ON GYPSUM BOARD
COVERED WITH CONTRACTOR- FURNISHED WALLCOVERING.
B. TRACK: HEAVY DUTY WITH 4 STEEL B.B. WHEELS AND NYLON
TIRES.
C. SUPPORT: DESIGN AND FABRICATE STEEL SUPPORT FRAMING
SYSTEM ABOVE CEILING TO SUPPORT OPERABLE PARTITION.
D. STACKING: SURFACE STACKING, NO POCKET.
.03 INSTALLAT ION
A. INSTALL OPERABLE PARTITIONS USING METHOD INDICATED IN
STRICT COMPLIANCE WITH MANUFACTURER'S WRITTEN
INSTALLATION INSTRUCTIONS; COMPLYING AS APPLICABLE
WITH ANSI E557, STANDARD RECOMMENDED PRACTICE FOR
ARCHITECTURAL APPLICATION AND INSTALLATION OF
OPERABLE PARTITIONS.
B. LUBRICATE BEARINGS AND SLIDING PARTS; ADJUST TO ENSURE
SMOOTH, EASY OPERATION.
10810 TOILET ACCESSORIES
.01 MANUFACTURER: BOBRICK OR ACCEPTED EQUAL.
.02 TOWEL DISPENSER AND DISPOSAL: 8-3944.
.03 SOAP DISPENSER: B -4112.
.04 TOILET TISSUE DISPENSER: B-2:18.
.05 GRAB BARS: B -6293 AND B- 6206 -36.
.06 USE CONCEALED FASTENINGS WHEREVER POSSIBLE.
.07 PROVIDE ANCHORS, BOLTS AND OTHER NECESSARY FASTENERS, AND
ATTACH UNITS SECURELY TO WALL AND PARTITIONS IN LOCATIONS AS
SHOWN OR DIRECTED. ATTACH ACCESSORIES TO WOOD BLOCKING
WHERE REQUIRED, (COORDINATE WITH DIVISION 6 SECTION "ROUGH
CARPENTRY ") . COMPLY WITH THE MANUFACTURER'S INSTALLATION
INSTRUCTIONS FOR EACH TYPE OF SUBSTRATE CONSTRUCTION.
DIVISION 15
15010 BASIC MECHANICAL REQUIREMENTS
.01 COMPLY WITH, BUT NOT BE LIMITED TO, THE FOLLOWING CODES AND
AUTHORITIES. IF CONFLICTS OCCUR BETWEEN THE DRAWINGS AND
AUTHORITIES, THE MOST STRINGENT SHALL GOVERN:
LOCAL CODES AND ORDINANCES
STATE CODES AND ORDINANCES
DEPARTMENT OF HEALTH AND REHABILITATIVE SERVICE
NATIONAL FIRE PROTECTION ASSOCIATION
LOCAL UTILITY COMPANY REQUIREMENTS
.02 OBTAIN AND PAY FOR ALL PERMITS AND CERTIFICATES OF
INSPECTION ION AND APPROVAL, AND COST OF UTILITY SERVICES.
15140 SUPPORTS AND ANCHORS
.01 SECURELY SUPPORT PIPING WITH CLEVIS OR RING TYPE HANGERS
MANUFACTURED BY FEE & MASON, GRINNEL, ELCEN OR AUTO -GRIP AT
10' -0" O.C. MAXIMUM.
.02 SUPPORT INSULATED PIPING WITH HANGERS SIZED TO FIT OUTSIDE
OF INSULATION. AT EACH HANGER PROVIDE A 16 GAGE 5htEl METAL
GUARD SHAPED TO FIT OUTSIDE DIAMETER OF INSULATION. SIZE
GUARD TO COVER ONE HALF THE INSULATiON CIRCUMFERENCE AND
LENGTH OF 2.5 TIMES THE INSULATION OUTSIDE DIAMETER, MINIMUM.
.03 PROVIDE ANCHORS FOR RODS OF TYPE. SIZE AND SPACING AS
REQUIRED TO PROVIDE ADEQUATE SUPPORT.
.04 PIPE HANGERS: CLEVIS TYPE AS MANUFACTURED BY GRINNELL: USE
TO HANG ALL PIPING AT ROOF STRUCTURE OR IN CEILING SPACE.
PERFORATED PIPE STRAP IS NOT PERMITTED.
15250 MECHANICAL INSULATION
.01 INSULATE POTABLE COLD AND HOT WATER PIPING AND CHILLED
WATER PIPING WITH 1" FIBERGLASS PIPE COVERING HAVING ALL
SERVICE VAPOR BARRIER JACKET. INSULATE CONDENSATE DRAIN
PIPING WITH 1/2" FIBERGLASS PIPE COVERING HAVING AN ALL
SERVICE VAPOR JACKET OR 1/2" ARMAFLEX. OWENS - CORNING 25ASJ.
SEAL JOINTS WITH VAPOR BARRIER TAPE AND ADHESIVE.
.02 COVER FITTINGS, VALVES , INSULATION ENDS, INCLUDING FLANGES
WITH 7 1/4 LB. PER CU. FT. DENSITY FIBERGLASS PREMOLDED
FITTINGS OR SEGMENTS OF THICKNESS EQUAL TO INSULATION ON
ADJOINING PIPE. TIGHTLY FITTED AND WIRED IN PLACE. APPLY A
COAT OF INSULATING CEMENT TO PRODUCE A SMOOTH SURFACE.
WHEN CEMENT DRIES, APPLY A COAT OF APPROVED VAPOR SEAL
MASTIC AND WRAP WITH FITTING TAPE , 50% OVERLAP, WHILE MASTIC
IS STILL TACKY. APPLY SECOND COAT OF MASTIC, WORK WELL INTO
MESH OF TAPE AND TROWEL SMOOTH, OR COVER WITH ZESTON
FITTINGS.
09300 TILE
.01 REFER TO FINISH MATERIAL CODES FOR TILE TYPES, SIZES & COLORS
AND ROOM FINISH SCHEDULE FOR LOCATIONS.
.02 BASE AND TRIM: PROVIDE SPECIAL SHAPES AND PREFABRICATED
CORNERS.
.03 SETTING MATERIAL:
A. WALL TILE: LATEX ADHESIVE.
B. FLOOR TILE: LATEX - MODIFIED PORTLAND CEMENT TH INSET .
.04 GROUT;
A. WALL TILE: UNSANDED WALL TILE GROUT WITH LATEX
ADDITIVE.
B. FLOOR TILE: SANDED FLOOR TILE GROUT WITH LATEX
ADD IT IVE .
.05 LEVELING COMPOUND: QUICK SETTING. NON SHRINK INK MATERIAL AS
RECOMMENDED BY TILE MANUFACTURER.
.06 WATERPROOF MEMBRANE: NOBLESEAL "TS CPE" OR COMPOTITE
"COMPOSEAL GOLD ".
.07 PREPARE SUBSTRATE AND INSTALL TILE IN ACCORDANCE WITH TILE
MANUFACTURERS RECOMMENDATIONS AND THE TILE COUNCIL OF
AMERICA'S HANDBOOK.
.08 INSTALL WATERPROOF MEMBRANE IN ALL FLOOR TILE LOCATIONS ON
ELEVATED SLABS. INSTALL PER MANUFACTURER'S
RECOMMEND AT IONS.
09510 ACOUSTICAL CEILINGS
.01 COORDINATION : COORDINATE LAYOUT AND INSTALLATION OF
ACOUSTICAL CEILING UNITS AND SUSPENSION SYSTEM COMPONENTS
WITH OTHER WORK SUPPORTED BY OR PENETRATING THROUGH,
CEILINGS, INCLUDING LIGHT FIXTURES, HVAC EQUIPMENT, FIRE-
SUPPRESSION SYSTEM COMPONENTS, PARTITIONS SYSTEM, ETC.
.02 CEILING PANELS: REUSE EXISTING PANELS & SUPPLEMENT AS
REQUIRED FROM LANDLORD STOCK.
.03 METAL SUSPENSION SYSTEM; EXISTING GRID TO REMAIN.
.04 ATTACHMENT DEVICES: SIZE FOR FIVE (5) TIMES DESIGN LOAD
INDICATED IN ASTM C -635, TABLE 1, DIRECT HUNG.
.05 INSTALL MATERIALS IN ACCORDANCE WITH MANUFACTURER'S
PRINTED INSTRUCTIONS, AND TO COMPLY WITH GOVERNING
REGULAT IONS , FIRE RESISTANCE RATING REQUIREMENTS AS
INDICATED, AND INDUSTRY STANDARDS.
09650 RESILIENT FLOORING
.01 REFER TO FINISH MATERIAL CODES FOR RESILIENT FLOORING TYPES,
SIZES AND COLORS AND TO ROOM FINISH SCHEDULE FOR LOCATIONS.
.02 PREPARE SUBSTRATE AND INSTALL RESILIENT FLOORING IN
ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
09680 CARPET
.01 REFER TO FINISH MATERIAL CODES FOR CARPET AND CARPET TILE
TYPES, SIZES, PATTERNS AND COLORS AND TO ROOM FINISH
SCHEDULE AND FLOOR PLANS FOR LOCATIONS.
.02 ADHESIVE: WATER RESISTANT, NON STAINING TYPE AS
RECOMMENDED BY CARPET MANUFACTURER.
.03 SEAMING CEMENT: HOT MELT SEAMING ADHESIVE AS RECOMMENDED
BY MANUFACTURER TO FORM SECURE, INVISIBLE SEAMS.
.04 INSTALL CARPET PARALLEL TO LONG DIMENSION OF FLOOR WITH
MINIMUM OF END OR BUTT SEAMS.
.05 INSTALLATION: APPLY ADHESIVE UNIFORMLY TO SUBSTRATE IN
ACCORDANCE WITH MANUFACTURER'S INSTRUCTION. BUTT CARPET
EDGES TIGHTLY TOGETHER TO FORM SEAMS WITHOUT GAPS. ROLL
ENTIRE CARPET AREA LIGHTLY TO ELIMINATE AIR POCKETS AND
ENSURE UNIFORM BOND. REMOVE ADHESIVE PROMPTLY FROM FACE
OF CARPET.
.06 INSTALL CARPET TILE IN ACCORDANCE WITH MANUFACTURER'S
PRINTED INSTRUCTIONS. PROVIDE DOUBLE -STICK TAPE OR ADHESIVE
INSTALLATION ONLY WHERE SPECIFICALLY REQUIRED BY USE OR
PROJECT COND IT IONS.
09900 PAINTING
.01 PAINT PRODUCTS INDICATED ARE BASED ON SHERW IN WILLIAMS.
COMPARABLE PRODUCTS FROM OTHER MANUFACTURES MlAY BE
USED IF ACCEPTABLE TO OWNER.
.02 INTERIOR FERROUS METAL:
A. ONE COAT METAL PRIMER
B. TWO COATS
C. SPOT PRIME & ALKYD ENAMEL. APPLY ONE COAT ALKYD
ENAMEL AT EXISTING INTERIOR METAL.
.03 INTERIOR GYPSUM BOARD
A. ONE COAT PROMAR 200 LATEX PRIMER.
B. TWO COATS PROMAR 200 LATEX EG -SHEL
.04 INTERIOR WOODWORK:
A. ONE COAT WALL AND WOOD PRIMER.
B. TWO COATS PRO- CLASSIC ALKYD SEMI -GLOSS ENAMEL.
.05 ACCESSORIES: SOLVENTS, THINNERS, SPACKLING COMPOUND AND
OTHER ITEMS AS REQUIRED TO COMPLETE PAINTING.
.06 FOLLOW PAINT MANUFACTURER'S RECOMMENDATIONS FOR
PREPARATION AND INSTALLATION METHODS.
09950 WALLCOVERINGS
.01 WALLCOVERINGS: REFER TO FINISH MATERIAL CODES.
.02 FOR WALL AREAS REQUIRING PATCHING OR OTHER WORK, REMOVE
EXISTING WALLCOVERING BACK TO NEAREST INSIDE CORNER AND
REPLACE WITH NEW. DO NOT SPLICE OR OVERLAP NEW MATERIALS
WITH EXISTING MATERIALS IN THE SAME PLANE.
.03 PRIME AND SEAL SUBSTRATES IN ACCORDANCE WITH THE
WALLCOVERING MANUFACTURER'S RECOMMENDATIONS FOR TYPE OF
SUBSTRATE. APPLY A SURFACE SEALER TO GYPSUM BOARD WHICH
WILL PERMIT SUBSEQUENT REMOVAL OF WALLCOVERING WITHOUT
DAMAGE TO PAPER FACING.
.04 INSTALLATION: PLACE PANELS CONSECUTIVELY IN THE ORDER CUT
FROM ROLLS, INCLUDING FILLING SPACES ABOVE OR BELOW
OPENINGS. HANG BY REVERSING ALTERNATE STRIPS EXCEPT ON
MATCH PATTERNS.
VERIFY THAT COLORS AND PATTERNS OF WALLCOVERINGS ARE
THOSE SPECIFIED BEFORE BEGINNING INSTALLATION.
A. APPLY ADHESIVE TO THE BACK OF THE WALLCOVERING AND
PLACE IN ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS.
B. INSTALL SEAMS PLUMB, AND AT LEAST 6 INCHES AWH� FROM
CORNERS. HORIZONTAL SEAMS WILL NOT BE PERMITTED,
OVERLAP SEAMS AND DOUBLE -CUT OR BUTT AS
RECOMMENDED BY MANUFACTURER TO ENSURE TIGHT
CLOSURE.
C. ROLL, BRUSH OR USE A BROAD KNIFE TO REMOVE AIR
BUBBLES, WRINKLES, BLISTERS, AND OTHER DEFECTS. CUT
WALLCOVERING EVENLY TO THE EDGES OF WALL
PENETRATIONS.
D. TRIM SALVAGES AS REQUIRED TO ENSURE COLOR UNIFORMITY
AND PATTERN MATCH.
i
= i
i
w
U
w
Q
0
w
'° y�i� L
0
ge pp -c
;.• M z g
$ 425" O
N
c2o: T--0 3 `a cl
00
� �C3
U Q U IU - O o
Ly T O C
d � d CL
N C O O
t� O•S U
o°
a� c�DhL
-0 LLI
>� D FE L t� u
0 3 v N
0-0 p N O U[[
pp�� U �_ O
vii C V D O O N v
7 m �O O_
N
_ cr
LL z_
0
W
z
z
Ix
W
LLI w
z
t�
z N
W °
N
W �0
�oo
Imo-'
u
L
F_ z�Q�
z
! U N
a'
< UL
Ci
t~ V
i
0
et%
a
V
L
W
V
V
W
10.
V.
co
LL '-
�
O
�.
Ca X s
a
.J Z
Z Z
aC
Z 0 --
co)
0
Z ui Wcc
V
cr Z v
DATABASE db.52042Qa8
DRAWN GOF
CHECKED GPH
Q. C. REVIEW
_I
DRAWING 081595
DATE
JOB
NUMBER 6204.20
PRINT
DATE
C1.2