HomeMy WebLinkAboutM0.1PLUMBING FIXTURE CONNECTION SCHEDULE —ST— ST CHI CO �O SPEC 15440 MARK FIXTURE A CONNECTION PIPE SIZES z 0 BASIS OF DESIGN W REMARKS AND ABBREVIATIONS CW HW _ S _ _ _ _ _ MANLFACTURER MODEL WC -1 WATER CLOSET 1" - c 4" U O M REFER SPECS REFER SPECS WH, FV, OFS WC -2 WATER CLOSET 1" - 4" REFER SPECS REFER SPECS WH, FV, OFS, HC UR -1 URINAL 3/4" - 2" REFER SPECS REFER SPECS WH, FV, HC LAV -1 LAVATORY 1/2" 1/2" 1 1/4" REFER SPECS REFER SPECS WH, GNS, WB, HC LAV -2 LAVATORY 1/2" 1/2" 1 1/4" REFER SPECS REFER SPECS CT SK -1 DOUBLE COMPARTMENT SINK 1/2" 1/2" 1 1/2" REFER SPECS REFER SPECS CT, SS, SW OREMARKS ABBREVIATIONS CPSK CUP SINK CT COUNTER TOP FM FLOOR MOUNTED FP FOOT PEDALS FT FLUSH TANK FV GNS HC 0 OFS FLUSH VALVE SLF GOOSENECK SPOUT SS HANDICAPPED STD OVAL SW OPEN FRONT SEAT TLD SINGLE LEVER FAUCET STAINLESS STEEL STANDARD SWING SPOUT TANK LOCKING DEVICE WB WH WRIST BLADES WALL HUNG 1/2" MANUAL AIR VENT PRESSURE /TEMPERATURE PORT MODULATING 2 -WAY I TEMPERATURE CONTROL VALVE '\_-1 /2" DRAIN ►4 CHR CHS CALIBRATED BALANCING VALVES TO BE LOCATED MIN 5 P PE D IA UPSTREAM & 10 PIPE D IA DOWNSTREAM OF STRAIGHT PIPE NOTES: 1. LOCATE PIPING TO PERMIT ACCESS TO UNIT DOORS & PERMIT COIL REMOVAL. DETAIL CHILLED WATER COOLING COIL PIPING (2 -WAY VALVE) i LEGEND GENERAL NOTES J - - - -- V - CW - - HW - - - -- HWC FP s —ST— ST - - - -- V - CW - - HW - - - -- HWC FP FP �lL CO CHI CO �O FD -1 M HD A WHA IE FCU O i /ZZ CR CHS CHR T'STAT 6" D SANITARY OR WASTE PIPING STORM DRAINAGE PIPING VENT PIPING COLD WATER PIPING (DOMESTIC) HOT WATER PIPING (DOMESTIC 120 ° F ) HOT WATER CIRCULATING (DOMESTIC 120 °F ) FIRE PROTECTION PIPING CLEANOUT (FLOOR) CLEANOUT (IN RISE) FLOOR DRAIN - # INDICATES TYPE HUB DRAIN WATER HAMMER ARRESTER (LETTER INDICATES TYPE) GATE VALVE BALL VALVE CALIBRATED BALANCING VALVE STRAINER WITH BLOWOFF VALVE PRESSURE GAGE WITH GAGE VALVE INVERT ELEVAT ION SYSTEM TURNING UP SYSTEM TURNING DOWN BRANCH CONNECTION FROM BOTTOM BRANCH CONNECTION FROM TOP RISE OR DROP IN SYSTEM NEW FAN COIL UN IT NEW OR RELOCATED THERMOSTAT EXISTING THERMOSTAT NEW OR RELOCATED SUPPLY DIFFUSER EXISTING SUPPLY DIFFUSER RETURN GR ILLE EXISTING RETURN GRILLE DUCT TRANSITION VOLUME DAMPER RIGID DUCT EXISTING TO BE REMOVED CONDENSATE RETURN CHILLED WATER SUPPLY CHILLED WATER RETURN THERMOSTAT ROUND DUCT SIZE DUCT CAP A. ARROWS SHOWN ON DUCTWORK INDICATE CHANGE IN DUCT SIZE AND FLOW DIRECTIONS. B. DRAWINGS ARE SCHEMATIC IN NATURE AND SHOW DESIGN INTENT. ALL EXISTING EQUIPMENT AND PIPING LOCATIONS ARE TO BE FIELD VERIFIED. IF CHANGES ARE REQUIRED DUE TO DIFFERING FIELD CONDITIONS. SKETCHES OF SUGGESTED MODIFICATIONS ARE TO BE SUBMITTED TO OWNER OR A/E FOR APPROVAL PRIOR TO ANY CHANGES. C. ROUTE PIPING AS TIGHT TO STRUCTURE AS POSSIBLE WHILE MAINTAINING PROPER SLOPE. D. REPAIR ANY WORK DAMAGED AS A RESULT OF WORK REQUIRED BY THIS CONTRACT. E. SEAL PENETRATIONS TH#1GH FULL HEIGHT PART IT IONS WITH NON-HARDENING SEALANT. F. PROVIDE MANUAL VOLUME DAMPERS IN ALL DIFFUSER INLET DUCTS AND AS SHOWN. ALL DIFFUSERS TO HAVE DAMPER ADJUSTMENT ACCESSIBLE THROUGH THE FACE. G. INSTALL DUCTWORK AS HIGH AS POSSIBLE. H. REFER TO "A" DRAWINGS FOR MECHANICAL EQUIPMENT LOCATIONS IN THE CEILING. J. PROVIDE REQUIRED DUCT TRANSITION TO CONNECT EXISTING WORK TO NEW DUCTWORK. K. HANG ALL PIPING AND DUCTWORK INDEPENDENTLY OF EACH OTHER AND THE CEILING GRID. L. MAINTAIN 9" VERTICAL CLEARANCE SPACE BETWEEN THE BOTTOM OF PIPING, PIPING INSULATION, OR DUCTWORK AND THE CEILING. M. WORK SHOWN IN HEAVY LINES INDICATE NEW OR RELOCATED WORK. WORK SHOWN IN LIGHT LINES INDICATE EXISTING WORK TO REMAIN. CROSS-HATCHING INDICATES EXISTING DUCTWORK AND EQUIPMENT TO BE REMOVED OR RELOCATED. N. INSTALL ALL EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. P. ALL EXPOSED DUCTWORK SHALL BE PAINTED. REF "A" DWG FOR COLOR, ETC. Q. LOCATE ALL THERMOSTATS AND EMS SENSORS AS SHOWN, MOUNTED AT THE SAME ELEVATION AS THE EXISTING STATS. R. DIFFUSERS SHOWN AS BEING REMOVED OR RELOCATED FROM BELOW DUCTWORK SHALL HAVE BRANCH DUCTWORK CAPPED AS HIGH AS POSSIBLE. SEAL ALL CAPPED BRANCHES AIRTIGHT. INSULATE TO MATCH EXISTING DUCT INSULATION. S. COORDINATE WITH BUILDING OWNER FOR FURNISHING AND/OR INSTALLING ANY CONTROL DEVICES (INCLUDING FCU CONTROL VALVES. VVU ACTUATORS, THERMOSTATS, AND ACCESSORIES) REQUIRED FOR INTERFACING WITH THE EXISTING EMS. T. PROVIDE HARD COPPER TUBING WITH SOLDER JOINTS FOR CONDENSATE DRAINS. P ITCH DOWN IN FLOW DIRECTION AT 1/8" PER FOOT. U. MODIFY SPRINKLER SYSTEM AS REQUIRED TO ACCOMMODATE WALL AND CEILING CONSTRUCTION AND IN ACCORDANCE WITH NFPA 13. V. MODIFY FIRE PROTECTION PIPING AND HEADS IN THE ELEVATOR LOBBY AND HIGH DENSITY FILING AREAS ON BOTH THE 4TH AND 5TH FLOORS AS FOLLOWS: 1. ELEVATOR LOBBIES a) MODIFY PIPING AND HEADS TO ACCOMMODATE RA ISED CE IL ING . 2. HIGH DENSITY F IL ING AREAS a) RAISE ALL PIPING TO ACCOMMODATE HEIGHT OF HIGH DENSITY FILES. RE -ROUTE PIPING AROUND THIS AREA AS REQUIRED. b) SPRINKLER HEAD DEFLECTOR PLATES MUST BE AT 1 ' -6" ABOVE HIGH DENSITY FILES. W. ALL DIFFUSERS SHOWN ARE ASSUMED TO BE "TITUS" TMS -8' DIA NECK, UNLESS NOTED OTHERWISE. WHERE EXISTING STOCK IS DEPLETED, PROVIDE NEW OF SAME TYPE, STYLE, COLOR, ETC. X. PRIOR TO ANY DEMOLITION WORK , MEASURE AND RECORD THE AIR FLOW RATE (CFM) OF THE ROOF TOP FAN EXHAUSTING AIR FROM THE PUBLIC RESTROOMS BEHIND THE ELEVATORS. AT THE COMPLETION OF THE PROJECT, BALANCE THE EXHAUST FAN TO THE PREVIOUS AIR FLOW RATE PLUS 200 CFM. (FOR THE ADDITIONAL FOURTH FLOOR REST ROOM). Y. PRIOR TO ANY DEMOLITION OR NEW WORK. RECORD AIRFLOW READINGS IN EACH BRANCH DUCT AT SUPPLY RISERS AT EACH FLOOR (4 , 5 , 6) . AT COMPLETION OF WORK, REBALANCE BRANCH DUCTS TO ORIGINAL AIR QUANTITY. DRAWING NOTATION EQU IPMENT MARK POINT OF CONNECT ION ( 0)- KEYNOTE BUBBLE XX)= ROOM NAME AND NUMBER ROOM NAME ROOM NUMBER w 0 p 0 0 1 > (V d L L O fl- � _c I- � O O& L 7 C L j p �d o- o�ado a) Lplp V L ��� L) . ............. �lL 4. L- 0 x w y F- > (V d L L O fl- � _c I- � O O& L 7 C L j p �d o- o�ado a) Lplp V L ��� L) v �o rr� ~ V � z 0 r. `s o W z J U) a V W LL z N U 0 J0 IO 0 J z z IL a :5 Q Z z o Z O 44 W a- o W c� o ac a W W W Z t J — I= a V DATABASE db.520420m8 DRAWN MKR /BJG CHECKED TtJ fi Q. C. REVIEW DRAWING 81595 DATE XB NUME BER R 5204.20 PRINT DATE moul W 0 x w F- z 0 z_ W z(D U) w° N W No c U O M '� Hw- a z� U � L) � rn z ch Q �ULn v �o rr� ~ V � z 0 r. `s o W z J U) a V W LL z N U 0 J0 IO 0 J z z IL a :5 Q Z z o Z O 44 W a- o W c� o ac a W W W Z t J — I= a V DATABASE db.520420m8 DRAWN MKR /BJG CHECKED TtJ fi Q. C. REVIEW DRAWING 81595 DATE XB NUME BER R 5204.20 PRINT DATE moul