1. FURNISH ALL LABOR, MATERIAL & APPURTENANCES NECESSARY FOR A COMPLETE
AND OPERATIONAL SYSTEM AS SHOWN OR REQUIRED.
2. ALL WORK SHALL CONFORM TO APPLICABLE CODES AND AUTHORITIES HAVING
JURISDICTION. THE HVAC CONTRACTOR SHALL SECURE AND PAY FOR ALL
PERMITS, TESTS AND INSPECTIONS AS REQUIRED BY AUTHORITIES HAVING
JURISDICTION FOR HIS OWN WORK.
3. WORKMANSHIP SHALL REPRESENT THE HIGHEST STANDARD OF THE INDUSTRY.
4. GUARANTEE ALL MATERIAL & WORKMANSHIP FOR A PERIOD OF ONE YEAR AFTER
ACCEPTANCE.
5. PERFORM ALL TESTS, ADJUSTMENTS, ETC. AS REQUIRED BY EQUIPMENT
MANUFACTURER OR AUTHORITIES HAVING JURISDICTION.
6. BALANCE SUPPLY & RETURN AIR QUANTITIES AS REQUIRED FOR COMFORT
CONDITIONING.
7. INSULATE ALL SUPPLY AIR DUCTWORK IN ATTIC WITH 12" THICK DUCT WRAP/
VAPOR BARRIER INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
8. SHEET METAL DUCTWORK SHALL BE 24 GAUGE MINIMUM GALVANIZED SHEET
METAL FABRICATED AND INSTALLED IN ACCORDANCE WITH SMACNA. SEAL ALL
SEAMS WITH DUCT TAPE.
9. FLEXIBLE DUCT SHALL BE FACTORY FABRICATED METAL AIR DUCT AS MADE BY
,ATCO - VAL_.,LEX INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
10. CONDENSATE DRAIN PIPING SHALL BE PVC PIPE & FITTINGS OR AS REQUIRED
BY LOCAL CODE.
11. PROPOSALS SHALL BE BASED ON MATERIAL & EQUIPMENT LISTED. ONLY THOSE
SUBSTITUTIONS OFFERED AT BID TIME WILL BE GIVEN CONSIDERATION.
12. SUBMIT MANUFACTURER'S 0 & M MANUALS FOR ALL HVAC EQUIPMENT
13. HVAC CONTRACTOR SHALL PACK & SEAL ALL HVAC OPENINGS IN INSULATED WALLS
AND CEILINGS AIR -TIGHT WITH INSULATION.
GENERAL NOTES:
1. COORDINATE ALL GRILLE, REGISTER, EQUIPMENT, DUCT, ETC. LOCATIONS WITH
OTHER TRADES.
2. CONTROL WIRING FURNISHED & INSTALLED BY THE HVAC CONTRACTOR.
3. POWER WIRING FURNISHED & INSTALLED BY THE ELECTRICAL CONTRACTOR.
4. FURNISH ALL CUTTING REQUIRED FOR OWN WORK.
�. LOWER FLOOR - DUCTS RUN BETWEEN OR THRU FLOOR /CEILING JOISTS. TOP
FLOOR - DUCTS RUN IN ATTIC & INSULATED WITH 12" THICK FIBERGLASS
WITH VAPOR BARRIER.
6. EXHAUST FAN DUCTS UP IN CHASE WALL TO ATTIC WITH ROOF CAP.
7. ALL UNITS TYPICAL UNLESS NOTED OTHERWISE.
FIRE DAMPERS SHALL BE INSTALLED IN ALL CEILING DIFFUSERS AND IN
FURNACE BONNET AT CEILING.
9. DRYER VENT DOWN THRU CEILING 6 ".
10. 6" PVC UP THRU SLAB FOR REFRIGERANT LINES.
11. PROVIDE SHEET METAL FITTINGS FOR BRANCHES OFF MAIN DUCT.
12. BOXES SHOW CFM & DUCT SIZES FOR TOP FLOORS.
13. NUMBERS SHOWN ON AIR DEI ICES ARE HART & COOLEY
EQUIPMENT:
FURNACES: LOWER FLOORS: CARRIER 40RC018300CF, 7.5 KW 23011
TOP FLOORS: CARRIER 40RCO24300CF, 7.5 KW, 230/1
CONDENSERS: LOWER FLR: CARRIER 38TG018 230/1
TOP FLOOR: CARRIER 38TG024 23011