Loading...
HomeMy WebLinkAbout06080001.27- - -- 4 SECOND FLOOR PLAN I,Bw� I e -0� N PLAN NORTH GENERAL NOTES �� >> HV J � Q W u p ,z 1. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS AND JOB � U � F- CONDITIONS. ANY DEVIATION FROM WHAT IS NOTED N � z = Q o � u; ,u �? F- Z � H IN DRAWINGS SHALL BE BROUGHT TO THE ATTENTION O � w � � OF THE ARCHITECT IMMEDIATELY. � a _ U �Q?��W� 2. ALL DIMENSIONS SHOWN ARE FACE OF BRICK, N z u � � �, Q � MASONRY OR METAL STUD FRAMING- UNLESS NOTED � � O � = Z O u� OTHERWISE. o � w = H_Q 3. PROVIDE DEEP LEG DEFLECTION TRACK AT ALL =LJ � t- '�++W��izU METAL STUD CONNECTIONS WITH STRUCTURE o ? a m � � ,,; ABOVE- TYPICAL. Q Z� O a j �°oV 4. PROVIDE FIRE RATED WOOD BLOCKING IN METAL U O � F- Z „� _ STUD WALLS FOR ANY WALL SUPPORTED ITEMS. � N � Z � O U 5. PROVIDE APPROVED FIRE RATED STOPPING MATERIALS � � w � O Z IN ANY OPENINGS IN FIRE RATED ASSEMBLIES. t7 U � Q � N O 6. REFER TO DOOR AND WINDOW SCHEDULES FOR ALL � � ? Q � v O MATERIALS, FINISHES AND HARDWARE INFORMATION. 7. REFER TO EXTERIOR ELEVATIONS FOR ALL BRICK THAT MATERIAL WAS NOT REVIEWED BY THE MASONRY AND OTHER EXPANSION JOINT LOCATIONS. '1' 8. ALL MATERIALS LOCATED IN CEILING PLENUM SHALL BE RATED FOR SUCH INSTALLATION OR PROTECTED TO PROVIDE COMPLIANCE. THIS INCLUDES BUT IS � � NOT LIMITED TO POWER AND LOW VOLTAGE WIRING, � TELECOMMUNICATIONS CABLING, PLUMBING SUPPLY m AND DRAIN LINES AND SUPPORTING BRACKETS N AND /OR BLOCKING FOR CEILING HUNG ITEMS. a 9. PRIOR TO ORDERING ANY PRODUCTS - CONTRACTOR v SHALL SUBMIT SAMPLES TO THE ARCHITECT OF ALL � FINISH MATERIALS TO BE USED ON 7HE PROJECT. m °o THE CONTRACTOR SHALL BEAR SOLE RESPONSIBILITY � cUn � `" FOR ANY MATERIALS ORDERED INCORRECTLY WHEN N THAT MATERIAL WAS NOT REVIEWED BY THE � '1' ARCHITECT. O �' Z � -' 10. PROVIDE CONCRETE FILLED STEEL PIPE BOLLARDS m `° U � AT ALL REQUIRED UTILITY EQUIPMENT LOCATIONS Z "' Q SUCH AS GAS METERS, ELECTRICAL � u W � TRANSFORMERS.PANELS ETC. COORDINATE WITH � _ _, � UTILITY COMPANY AND CONTRACTORS -WHEN D u U H APPLICABLE -FOR NECESSARY LOCATIONS. REFER TO CML DRAWINGS FOR BOLLARD SPECIFlCATIONS AND ADDITIONAL INFORMATION. KEYED NOTES ODENOTES STEEL LADDER TO ROOF. LOCATION IS NOT SPECIFIED HERE. DASHED LINES INDICATE APPROXIMATE LOCATION OF TENANT'S JANITORIAL ROOM WHERE THE LADDER WILL BE PLACED, FIELD DETERMINE LADDER'S EXACT PLACEMENT AND COORDINATE WITH STRUCTURAL DRAWINGS. OCHASE WAIL. CONSTRUCT FROM 3�" MEZAL STUDS WITH ONE LAYER OF �" GYP BOARD AT OUTSIDE FACE. OREFER TO DRAWING A1.3 FOR STAIR PLANS AND NOTES. OINDICATES APPROX LOCATION AND SIZE OF ENTRY CANOPY BELOW. OCOORDINATE REQUIRED CLEAR HOISTWAY DIMENSIONS WITH ELEVATOR INSTALLER PRIOR TO PLACING WALL ASSEMBLIES. DIMENSIONS AS SHOWN FOR HOISTWAY ARE FINISHED DIMS. z O w ```\`��tttt���ur • ,�.��QN_...... . �: cJ =�° . � :W � O =�Nzo •� U w W m J cV 00 °o O mot' Q z Q z J J_ J m Z U_ > 00 d' 00 00 � O� M M � f\ � t� 1� � M M W CTO "' _� � O�� �(7�(r' V• W ��...... � Q. , b ��'�-. � ,,� ys -� �" ���''�rrl���rt,tt��`� W U i � I� J a J Q U � W Z � W J � � Z m O W a U W LL J oa z W Z Z O. J Z Z W 4. D az za ao cz � J � � � � OU ACG05002 a t