Loading...
HomeMy WebLinkAbout05110017 Exterior Elevations Rcv. no dateEl. ti 0 M M O O N Lo r e- - J DIVISION 1 - GENERAL REQUIREMENTS DIVISION 5 - METALS 1.1 THESE GENERAL NOTES ARE ORGANIZED BASE UPON THE CONSTRUCTION 5.1 STRUCTURAL STEEL FRAMING MEMBER. REF. STRUCTURAL DRAWINGS. DIVISI SPECIFICATIONS INSTITUTE'S 16 DIVISION FORMAT. 5.2 STRUCTURAL STEEL GIRT. 7 1 5.3 STEEL JOIST. REFERENCE STRUCTURAL DRAWINGS. 7 2 DIVISION 2 - SITEWORK 5.4 STEEL DECKING. REFERENCE STRUCTURAL DRAWINGS. 7 3 5.5 6 STEEL STUDS. SEE STRUCTURAL NOTES. 2.1 FINISH GRADE. 5.6 4; STEEL STUDS. SEE STRUCTURAL . URAL NOTES. 75 2.2 DRAINAGE FILL. 5.7 6 18 GA. STEEL STUDS 0 16 O.C., CROSS BRACING AS REQ D. 7.6 5 2.3 COMPACTED EARTH. 5.8 18 GA. CLIP ANGLE. 2.4 CONCRETE SIDEWALK. 5.9 RELIEF ANGLE 7.7 5.10 8 STEEL STUDS AND /OR JOISTS. 7.8 5.11 VERTICAL LADDER Wf 1/2"x2 1/2" FLAT BAR RAIDS 18" APART W/ 7.9 DIVISION 3 - CONCRETE 3 4 "0 NON -SLIP RUNGS AT 12 O . "AT LEAST 7 CLEAR FROM 7.10 TIE WALL ANCHOR WITH 1/2 x2 12 L- SHAPED FLAT BAR AT 5 -0 O.C. MAXIMUM. 7.12 3.1 CONCRETE SLAB ON VAPOR BARRIER. SEE STRUCTURAL 5.12 MISCELLANEOUS STEEL REFERENCE STRUCTURAL DRAWINGS. 7.13 3.2 CONCRETE FOOTING FOUNDATION WAS, SEE STRUCTURAL 5.13 STEEL LINTEL PAINT AND PRIME TO MATCH BRICK 7.14 3.3 CONCRETE PIER. EFERENCE STRUCTURAL DRAWINGS. 5.14 4" DIAMETER STEEL POST BOLLARD W / CONC. FILL. 7.15 3.4 PRECAST INSULATED WALL SYSTEM 7,16 3.5 STEEL RtINFORCING, REFERENCE STRUCTURAL DRAWINGS 7.17 3.6 CONCRETE CURB. 7.18 DIVISION 4 - MASONRY 7'19 4.1 HORIZONTAL JOINT REINFORCEMENT SEE STRUCTURAL PLANS. DIVISION 6 - WOOD AND PLASTICS 7.20 4.2 8x8x 16 NOMINAL NORMAL WEIGHT CONCRETE MASONRY UNIT. 7.21 6.1 TREATED WOOD BLOCKING. 7.22 4,3 8x8x16 RIBBED SPLIT-FACED CMU. 6.2 W00,� SHIM. 7.23 4.4 ALUMINUM FLASHING - MIN. 26 GA. 6.3 3/4 TREATED EXTERIOR GRADE PLYWOOD SHEATHING. 7.24 4.5 PEA GRAVEL. 6.4 WOOD BLOCKING. 7.25 4,6 8" PRECAST INSULATED PANEL. SEE ELEVATIONS FOR FINISHES. 6.5 P ATIC LAMINATE ON 3/4" PARTICLE BOARD, ALL EXPOSED SURFACES. 6.6 3/4 PLYWOOD. 7.26 6.7 WOOD FRAMING PER SIZE NOTED 7.27 6.8 FIRE- TREATED WOOD 7.28 7.29 ON 7 - THERMAL AND AOISTURE PROTECTION DIVISION 8 - DOORS AND WINDOWS FLUID APPLIED WA- ERPROOFING. 8.1 STEEL DOOR. 1 112" PERIMETEF EXTRUDED POLYSTYRENE INSULATION. 8.2 STEEL DOOR - THERMAL RATED. 2" RIGID INSULATION. 8.3 STEEL DOOR FRAME. 6 MIL POLYETHYLENE VAPOR BARRIER. 8.4 GROUT BY DOOR INSTALLER. 6 ", R -19 PAPER - BACKED BATT INSULATION. 8.5 ALUMINUM DRIP EDGE. R -13 MINIMUM PAPER - BACKED BATT INSULATION. 8.6 OVERHEAD ROLLING STEEL DOOR, W /ELEC. OPERATOR. 26 CG A. PREFINISH RIBBED METAL SIDING 8.7 WEATHERSTRIPPING. 3/4' STEEL RUNNER CHANNELS 8.8 ALUMINUM STOREFRONT -CLEAR ANODIZED #14 R -12.5 MIN. POLYISOCYANU RATE ROOF INSULATION. 8.9 ALUMINUM THRESHOLD. BUILT -UP INSULATION TO ACHIEVE POSITIVE DRAINAGE. 8.10 &UMINUM ENTRANCE W/ CLEAR ANOD #14 MEDIUM STYLE DOOR. LAP SEALANT. 8.11 1 INSULATING GLASS. TERMINATION BAR. 8.12 1/4- TEMPERED GLASS. COUNTER FLASHING, 8.13 ALUMINUM FRAME CLEAR ANODIZED. PREFINISHED METAL DOWNSPOUT. ALUMINUM BOX SCUPPER FULLY ADHERED EPDM FLEXIBLE SHEET ROOFING SYSTEM. DIVISION 9 - FINISHES FLASHING WITH STAINLESS STEEL CLAMP RING. PREMANUFACTURED AND PREFINISHED METAL GRAVEL STOP 9.1 5/8" FIBERGLASS REINFORCED EXTERIOR GYPSUM BOARD SHEATHING. WITH CONTINUOUS HOLD DOWN CLIP. 9.2 5/8" gYPSUM WALL BOARD. PREMANUFACTURE0 AND PREFINISHED METAL COPING WITH 9.3 3, 5/8 x 25 GA. METAL STUDS Q 16" O.C. PREFABRICATED ANCHOR PLATE. 9.4 6 x 25 GA. METAL STUDS 0 16 O.C. PREFINISHED METAL FLASHING 9.5 METAL STUD KICKERS AS REQUIRED. SEALANT WITH BACKER ROD. 9.6 J MOLD EDGE TRIM. SEALANT JOINT. 9.7 1/2" RESILIENT CHANNEL ISOLATION JOINT WITH PREFORMED JOINT FILLER AND SEALANT. 9.8 ACOUSTICAL BLANKETS WATER CUT -OFF IAASTIC SEALANT. 9.9 PAINTED FINISH. SPRAY -ON FIRE PROOFING TO ACHIEVE 1 HR. RATING ON STRUCTURAL 9.10 SUSPENDED "GYPSUM BOARD CEILING. STEEL MEMBERS AND 1 HR. RATING ON METAL ROOF DECK. 9.11 4 ;5 GA. CH STUDS 0 24 O.C. WITH 1" GYPSUM LINER PANEL LATE( TOPPING TO ACHIEVE POSITIVE DRAINAGE. 9.12 3[4 MET. FURRING 5/8 CEMENT BOARD 9.13 A�c%%OUSTICAL SEALANT 3Y4" INSULATION BOARD SHEATHING. 9.14 1 1/2" 25 GA. METAL FRAMING. DLL FLASHING. 9.15 5/8 GYPSUM WALL BOARD, MOISTURE RESISTANT. 9.16 8 METAL STUDS ® 16 O.C. - SEE STRUCTURAL FOR GAUGES. DIVISION 10 - SPECIALTIES 10.1 DOOR OR WALL SIGNAGE 10.2 FIRE EXTINGUISHER CABINET DIVISION 11 - EQUIPMENT 11.1 4" DIAMETER STEEL PIPE BOLLARD W /CONCRETE FILL DIVISION 15 - MECHANICAL - ALL PLANS BY OTHERS. 15.1 HVAC UNIT - SUSPENDED 15.2 INTAKE OR EXHAUST GRILLE. SEE HVAC DRAWINGS. 15.3 PLUMBING WASTE PIPING, SEE PLUMBING DRAWINGS. 15.4 FAUCET SET - SINGLE LEVER 15.5 STEEL SINK BOWL 15.6 METERS 15.7 FLUSH VALVE TOILET SOUTH ENTRY SIDE ELEVATION - BUILDING #1 SCALE: 1/16' - 1'-0'+/- 432' Ir Ir b N b N 45' 15 30' WEST ELEVATION - BUILDING #2 SCALE: 1/16'= 1' -0" +/- as EAST ELEVATION - BUILDING #2 SCALE: 1116' = 1' -0' +/- NORTH ELEVATION - BUILDING #1 320' NORTH ENTRY SIDE ELEVATION - BUILDING #2 SCALE: 1/16' = 1' -0" +/- 320' SOUTH ELEVATION - BUILDING #2 SCALE: 4/16' = 1' -0" +I-