HomeMy WebLinkAbout0959.95.20r,
I
c�0
a�
I
M
b
9' -6"
18' -6•
17' -0'
102' -0"
25' -4 1 1,C
57' -0'
I��Illfl��l�l;llllll��
I I I 1 I I I I 1 I I I I 1 I I I I
I 1 I I I I 1 1 1 I I I I I I I I I I 1 I I 1 I I 1 I
�_ktj_ I
I I I I I I I I I I I I I I
1 1 I 1 I I 1 I I I I I I I I I I I I I I 1
I HOR�ONTAL BRIDGING III 1 1 1 1 1 1 1 1 1 1 1 1 1 1
I 1 1 1 1� -L1J-
-cv
1 1 I I I 18K6 0 T -o" O.C.
1 I I 1 1 I I I( I I I I I I I I I 1
— V I— __ � I i ' I 1 I 1 I 1 I 1 I 1 I 1 I I I I I I I I ► t 1
I I
o—I- - -- STUB PIPE
N I
w21 x62
-- -- -- -4-
-I-- --
- -- - r_ -7 - -- 17' - 1011 /�' �' — -- I -- - -�-- -- - --1 -- �-
-� O -- ____ __-II– - - --r -- �_
Cq
W12x19
-_4- -_ - - -i- -- --{ --
- -J-- -° -- --1 —bo - --
- STAIRWELL �" - - ---� - - - - -j--- b
- -- I- o —I -- -- b O - - -� -- --- -I---- 0 - --� —e -i --
-� I 3t PIPE STUB I I
- -- -;- b -I -- - -- COL'S. (TYP) - - -1 -- -- -i --'00_ I -°D
N —I -- 1' - -- W12x19 __ —t -- -- 7- -- —� 7
- -- I- o —I -- - -- RIFY'W ARCH._ I -_ - - -� -- --I- -- ?c --F -- --I --
-'1-
- A I z$ I I
CJ
—UJ— I -- I N
log
Cq C-41
r 1z
- -- I - --
=Z -- -- -- - -- - -
- r - t, Z w21 xs2 3.0 PIPE STUB
it
m ��yp t I I I
-- I I I COLS ( r) I I I I I
- -- —� -- {-- O I Its I I I ► I I 1
1 1 I I I I I I I I t 1 1 I I I
- -- - -- L- -- 7' 1 7'111 "I 115 -IC I 1 ' I 1 120'+f
END OF — J —I--+- — —
BEAM I 1 I I I 1 1 I 1 1 I 1 I 1 I I I I I I
`"'p) I 1 I 1 I I I I 1 I I I I I I I I I I
( C5 IIIIIIIIIIIIII
r I I I I I 1 1 1 1 1 1 1 t I 1 t I 1
I
1J_L1J_I I I 1 1 1 1
I I I I I I I 6 0 2' -0" O.C.I I I I I I
I I I I ,SK
I 1 1 I I I I I 1 1I I
I I 1 I I I I I I I I I I
I I I I 1 1 1 1 I I I 1 I I I I I I
28'-d*
I
45' -0•
5T--d'
102' -('
FLOOR FRAMING PLAN.
SCALE: 11a -11-v NORTH
TS 21/2x21/2x1/4
DECK SUPPORT --�
18K4
b
b
f3*9 STD. PIPE
STUB COL. BEYOND
W21
�-1 It CAP !�
'-- TS6x6 COL
SECTION ri`
SCALE: 3/4 " =1' -0" 51.2
Rte,
•�
Project No.
I
�
c
SW
Checked
MJL
SW
bI I SW
n
i%
FE
n
SW
WI
8d NAILS —
0 6" O.C.
TYPICAL AT
ALL PANEL
EDGES
8d NAILS -
0 12" O.C.
IN FIELD
OF PANEL
- 2 x BLOCKING 0 PANEL JOINTS
H WALL STUDS-
2X 0 16" O.C.
II SEE ARCH FOR SIZE
n
F 4'x8' PLYWOOD
PANEL ( C -D, C -C, OR
STRUCTURAL II )
1/2` DLk A.B. O 2' -0" O.C. TYP.
ALL PLYWOOD PANEL EDGES SHALL
BE SUPPORTED BY A MINIMUM OF
2" NOMINAL FRAMING.
TYP. PLYWOOD WALL SHEATHING
SW
NAILING PATTERN
NO SCALE
SW
SW
ALL EXTERIOR WALLS TO BE SHEAR WALLS.
INTERIOR WALLS AS SHOWN ON THIS PLAN
TO BE SHEAR WALLS. INTERIOR SHEAR WALLS
TO BE FASTENED CONTINUOUSLY TO ROOF
FRAMING AND ANCHORED TO FLOOR SLAB.
SEE 1/S1.2 FOR SHEAR WALL DETAILS.
SW sw
SW
sw
SW SW
SW
El
SHEAR WALL PLAN
NOT TO SCALE
SW
SW
Browning Day Mullins Dierdorf Inc
334 North Senate Avenue
Indianagolis Indiana 46204
317.635.5050
FAX 317.634.5409
STRUCTURAL CONSULTANT
I AWSON
ASSOCIATES
ENGINEERING
CONSULTANTS
650 EAST CARMEL DRIVE
SUITE 310
CARMEL, INDIANA 46032
317- 574 -9409
FAX 317- 574 -9431
zzz
No. *:
21487
0 SPATE of
I �
tv %c
it-
PRAIRIE
VIEW
GOLF
CLUB
Clubhouse—
Floor Framing Plan
S e-0
Project No.
9443 95OBS12
Drawn
JDF
Checked
MJL
Scale
1/8" =1' -0"
Date
9 -21 -95
Revision
-
Clubhouse—
Floor Framing Plan
S e-0