HomeMy WebLinkAbout0959.95.38�:.
6
DAMPER LOCATION OF BACKDRAFT
FAN MOTOR
iod '1 44
STL ANGLE
SUPPORTS
AS REQD.
j = DISCONNECT SWITCH SHALL
EXTERIOR i��AL BE PROVIDED BY FAN
WALL HOUSING MANUFACTURER.
PROPELLER WALL
EXHAUST FANDETAIL
NO SCALE M1.1
TYPE '8' FLUE
HIGH EFFICIENCY
UPFLOW FURNACE
FILTER RACK W/
1" PLEATED FILTER
PRIMED do PAINTED STEEL
FRAME BASE ('TYP -)
INTERNN.Y UNED
RETURN AIR PLENUM---,.,,
3 /i' THICK NEOPRENE
PAD BENEATH FURNACE
DUCT (SIZE VARIES)
DX COOLING COIL
/-W/ INSULATED CASING
REFRIGERANT
PIPING
RS
RL
31,' CONDENSATE TO
/— JANITOR'S SINK
i'
INTERNALLY UNED
RETURN AIR DUCT
FURNACE INSTALLATION DETAILr2
NO SCALE M1.1
n
.fft - &.AAAV
4
CLUBHOUSEZLOWER LEVEL PLAN - HVAC
e va=
PLAN NOTES:
1 SECURE VERTICAL PORTION OF DUCT TO WALL
HOLD DUCT TIGHT TO CEILING AND WALL
3 UNIT SHALL BE SUSPENDED FROM STRUCTURE. HOLD TIGHT TO CEILING. PROVIDE
SPRING TYPE ISOLATORS AT ALL POINTS OF SUSPENSION.
0
Browning Day Mullins Dlerdod Inc
334 North Senate Avenue
Indianapolis Indiana 46204
317.635.500
FAX 317.634.5409
1
ROTZ ENGINEERS INC.
I � '11 INDWOPOM M" "n4
15885
to STATE a8z
OF +.
DA
p1p Aid tt,l!
PRAIRIE
VIEW
GOLF
CLUB
Project No.
5=
Drawn
SOL
Checked
QAMC
Scale
AS NIM
Date
Revision