HomeMy WebLinkAbout0959.95.40�`- ROOFTOP UNIT CABINET GASKET BY ROOFTOP UNIT MFR. 3' CANT STRIP BY G.C. / DISCONNECT WOOD NAILE BY ROOFTOP UNIT MFR. / BUILT —UP ROOF BY G.C. BY FAN MR / ROOF INSULATION BY G.C. ROOF CURB BY ROOFTOP UNIT MFR. / 11 mil 1111111111 /i 1-1/2' RIGID / / /i // / / // // / /i // / INSULA INSULATION BY G.C. / / / / / PREFM CURB LJ_ LJ L PITCHED ROOF TYPICAL C NO SCALE �- METAL DECK BY G.C. -- METAL CHANNEL FILLERS BY M.C. URB D M EXHAUST FAN DETAIL r3""� NO SCALE M2.� AIR COOLED CONDENSING 1. ALL PIPING AND PIPING COMPONENTS UNIT ARE BY M.C. 2. PITCH ALL HORIZONTAL LINES A MINIMUM OF 1/f IN 10 FEET IN CHARGING VALVE DIRECTION OF REFRIGERANT FLOW 3. INSULATE ALL SUCTION LINES. 4. UNIT MANUFACTURER SHALL PROVIDE REFRIGERANT PIPING SCHEMATIC INCLUDING ALL LINES & VALVE SIZES AND EXACT LINES THRU ROOF LINE ROUTING. THIS MUST BE SUBMITTED USE PIPE ENTRY BY M.C. BEFORE CONSTRUCTION BEGINS. CURB. SEE SPEC. ` \ \� 5. ONLY ONE REFRIGERANT CIRCUIT SHOWN SECOND CIRCUIT SHALL BE SIMILAR. .Nt2IE: PIPING do VALUING ARRANGEMENT FOR 6 TONS AND GREATER ROOF NO SCALE ?UN ALUMINUM ROOF KHAUST FAN DROVIDE BIRD SCREEN AIN. It :DRAFT DAMPER SHEETMETAL DUCT XI -IAUST FAN DETAILri_� RAIN CAP (BIRD PROOF) HE16W AS crm WITH REQkJRED BY HARDENING CODE MASTIC OR I PLASTIC SEALER SUPPORT FLUE FROM ROOF STRUCTURE AS REQUIRED. STORM COLLAR ROW FLASHING z--- ROOFING TYPE 'B' FLUE GAS FLUE DETAIL rZ� NO SCPLE M2.1 r� { z I CURB CAP PTCHED TO DRAIN W/ ANTI— CONDENSATE COATING NEOPRENE GASKET WOOD NALER---�v PVC VENT CAP W1 ALUMINUM BACK- DRAFT-DAMPER { EVAPORATOR COIL THERMAL EXPANSION VALVE � tIWD LINE 1' RIGID INSULATION UCTIQN LINE (3 PCF DENSITY) SOLENOID VALVE PRE - CHARGED LINES FURNISHED BY EQUIPMENT MFR 00000 CPVC VENT PIPE (REFER PLAN ZE) Y It HIGH PREFABRICATED CURB r— ROOF SIGHT GLASS I FILTER DRYER r�� OIL TRAP USE SHORT, RADIUS ELBOWS. ROOF OPENIN } TOP OF TRAP SHALL BE A MIN. FRAMING (TYP J OF 1-1/2" BELOW LOWEST POINT OF EVAPORATOR COIL, PIING DIAGRAIVI DRYER VENT HIGH HAT DETAIL 6 REFRIGERANT NO SCALE NO SCALE M2.1 M2.1 J _ _ ■ �C _o (` YPICA) PO � U— 1 Q RTU -1 O RD Fi 0 27'x27' : I ACCU -1 i4,2. DN EQUIPMENT RAILS 14 "x37' 3 DISHWASHER DN" r M2.1 EXHAUST BY KITCHEN EQ. • 4 1 ti'M E CONTRACTOR 0 r2 ROOF CAP FROM EF -3 p r2 DUCT SUPPO (TYPICAL) M NT CC -1 ON PERIMETER S&=.i IN LATED ROOF Cl. R8 RD O n KITCHEN EXHAUST BY KITCHEN EQ. CONTRACTOR 30" x16" DN 10'1 I.D. FLUE 4 M2.1 Is CLUBHOUSE /ROOF P - HVAC PLAN TES' �1 DUCTWORK EXPOSED TO WEATHER. PROVIDE ONE (1) LAYER OF INSULATION BOARD AND APPLY PROTECTIVE COVERING PER SPECIFICATION. �2 M.C. SHALL PENETRATE SLOPED ROOF WITH THE USE OF A INSULATED ROOF CURB. COORDINATE PENETRATION WITH STRUCTURE AND G.C. FIELD VERIFY EXACT PENETRATION LOCATION AND COORDINATE WITH G.C. Browning Day Mullins Dierdort Inc 334 North Senate Avenue Indiana �olRS Indiana 46204 317.635.5050 FAX 317.634.5409 z ROTZ ENGINEERS INC. Cog Y�char+tor aM EMalded 8A¢ni�a . NDI�IIdAPOLJS. MIOtMik Ono \`\� ,u►�uriurrr 15895 - STATE VD Ai, PRAIRIE VIEW GOLF CLUB ,CO FLUE • o .D -. 5= Drawn SOL Checked GAMa ■ AS PKiI'm Date 9—d-95 REFRIGERANT J LINES DOWN TO { { DN W/ PIPE ENTRY CURB -.. _ M _ i 10'1 I.D. FLUE 4 M2.1 Is CLUBHOUSE /ROOF P - HVAC PLAN TES' �1 DUCTWORK EXPOSED TO WEATHER. PROVIDE ONE (1) LAYER OF INSULATION BOARD AND APPLY PROTECTIVE COVERING PER SPECIFICATION. �2 M.C. SHALL PENETRATE SLOPED ROOF WITH THE USE OF A INSULATED ROOF CURB. COORDINATE PENETRATION WITH STRUCTURE AND G.C. FIELD VERIFY EXACT PENETRATION LOCATION AND COORDINATE WITH G.C. Browning Day Mullins Dierdort Inc 334 North Senate Avenue Indiana �olRS Indiana 46204 317.635.5050 FAX 317.634.5409 z ROTZ ENGINEERS INC. Cog Y�char+tor aM EMalded 8A¢ni�a . NDI�IIdAPOLJS. MIOtMik Ono \`\� ,u►�uriurrr 15895 - STATE VD Ai, PRAIRIE VIEW GOLF CLUB Revision Project No. 5= Drawn SOL Checked GAMa Scale AS PKiI'm Date 9—d-95 Revision