HomeMy WebLinkAbout06010027.6900- TEMP006TIF- 4110!0634941 PM EL. L9' -8» T.O. NEW PARAPET EXISTING 2x PLATE TO REMAIN EL. 18' -0 »» T.Q. EXISTING CMU NEW 1 -1 /2" EIFS SYSTEM FULLY ADHERED TO BRICK EL. 10' -0» 8.0. EIFS E.I.F.S. DRIP EDGE EXISTING CMU TO REMAIN EXISTING BRICK TO REMAIN EXISTING CONC. SIDEWALK TO REMAIN D NEW ROOF MEMBRANE FULLY ADHERED NEW 5/8" EXTERIOR GRADE FIRE RETARDENT PLYWOOD NEW 6' 18 GA. KICKERS 0 16" D.C. MAX REMOVE EXISTING ROOF — MEMBRANE WITHIN LIMITS OF NEW SLOPED ROOFING EXISTING ROOF FRAMING TO REMAIN 3 WALL SECTION A -1 SCALE: 1/2" = 1' 0" EXISTING ROOF SYSTEM TO REMAIN NEW 6' 18 GA. METAL STUD BRACING 0 4' -0" O.C. MAX EL. 19' -8" T.O. NEW PARAPET 11p0 El iffill M i ki, 'U'A EXISTING 2x PLATE M, REMAIN ot I EL. LB -0» T.O. EXISTING CMU — NEW 1 -1/2" EIFS SYSTEM FULLY ADHERED TO BRICK BL. LO'-0" B.O. EIFS 411wwl cTl?lTtA EXISTING CMU TO REMAIN EXISTING BRICK TO REMAIN EXISTING PAVEMENT TO REMAIN PATCH TO MATCH 0 NEW PIER EXISTING ROOF SYSTEM TO REMAIN i 2 WALL SECTION A-1 SCALE: 1/2" = 1 -O" NEW ROOF MEMBRANE FULLY ADHERED NEW 5/8" EXTERIOR GRADE FIRE RETARDENT PLYWOOD NEW 6" 18 GA. KICKERS 0 16" O.C. MAX EXISTING ROOF FRAMING TO REMAIN REMOVE EXISTING ROOF MEMBRANE WITHIN LIMITS OF NEW SLOPED ROOFING ROOF MEMBRANEON 3" RIGID INSULATION PARAPET CAP BEYOND EXISTING ROOF CONSTRUCTION TO REMAIN - REMOVE EXIST. ROOF MEMBRANE WITHIN LIMITS OF NEW SLOPED ROOFING EXISTING ROOF FRAMING TO REMAIN EXISTING CEILING TO REMAIN EXISTING STEEL BEAM TO REMAIN EXISTING 2x FRAMING AND INSULATION TO REMAIN EXISTING ALUMINUM STOREFRONT AND GLAZJNG TO REMAIN EXISTING SLAB TO REMAIN ROOF MEMBRANE ON TAPERED 3" RIGID INSULATION CAP FLASHING BEYOND--------,, I WALL SECTION A -1 SCALE: 1/2* =, 1' -0" WI6x26 (SEE STRUCTURAL DWGS) 4»x4" 18 GA. CONT. ANGLE NEW ROOF MEMBRANE 3" RIGID INSULATION 5/8" EXTERIOR GRADE PLYWOOD f r f f / 3 -5/8" 18 GA METAL y NW OTE I STUD 0 16" O.C. MAX r / f / NEW BATT INSUL TO 1. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS RUN 12" INTO VOID / / AND ELEVATIONS 00 EXISTING ROOF CONSTRUCTION TO - REMAIN - REMOVE EXISTING ROOF MEMBRANE WITHIN LIMITS OF NEW SLOPED ROOFING EXISTING ROOF FRAMING TO REMAIN i 4 WALL SECTION A -1 SCALE: t* = 1; -0*— THREADED ROD PROVIDED BY MANUFACTURER CONCEALED IN TRELLIS VERTICAL TUBE SEE: STRUCTURAL DRAWINGS TRELLIS UNIT BY OTHERS w� o cp C C N W C C �E� an n oQ i2 a� c� .0 Cfj o� Ira co ov CON9i LTANT: FsEAL: cvs/ pharmacy STORE NUMBER: $8 � 1421 S. RANGE LINE ROAD CApMEL, IN 4603 SQUARE FOOTAGE: MAL 0101 AV* WAL FROU" AMA a M I% WA Rue" "or. REVISION$: 10/06/05: ISSUED FOR PERMIT 03/24/05: ISSUED FOR BIDOINls MW KMACM BAK PI.aaI#IINC,« WA c.�. PRA" IST: DA'L'E= I0/06/05 DRAWINt': W" AS NOTED ME$ SECTIONS NOTES, & DETAILS Aml COMM