HomeMy WebLinkAbout06010027.6900- TEMP006TIF- 4110!0634941 PM
EL. L9' -8»
T.O. NEW PARAPET
EXISTING 2x PLATE TO
REMAIN
EL. 18' -0 »»
T.Q. EXISTING CMU
NEW 1 -1 /2" EIFS
SYSTEM FULLY ADHERED
TO BRICK
EL. 10' -0»
8.0. EIFS
E.I.F.S. DRIP EDGE
EXISTING CMU TO REMAIN
EXISTING BRICK TO
REMAIN
EXISTING CONC.
SIDEWALK TO REMAIN
D
NEW ROOF MEMBRANE FULLY
ADHERED
NEW 5/8" EXTERIOR GRADE
FIRE RETARDENT PLYWOOD
NEW 6' 18 GA. KICKERS 0
16" D.C. MAX
REMOVE EXISTING ROOF —
MEMBRANE WITHIN LIMITS
OF NEW SLOPED ROOFING
EXISTING ROOF
FRAMING TO REMAIN
3 WALL SECTION
A -1 SCALE: 1/2" = 1' 0"
EXISTING ROOF SYSTEM TO
REMAIN
NEW 6' 18 GA. METAL STUD
BRACING 0 4' -0" O.C. MAX
EL. 19' -8"
T.O. NEW PARAPET
11p0 El
iffill M i ki, 'U'A
EXISTING 2x PLATE M,
REMAIN
ot I
EL. LB -0»
T.O. EXISTING CMU —
NEW 1 -1/2" EIFS
SYSTEM FULLY ADHERED
TO BRICK
BL. LO'-0"
B.O. EIFS
411wwl cTl?lTtA
EXISTING CMU TO REMAIN
EXISTING BRICK TO
REMAIN
EXISTING PAVEMENT TO
REMAIN PATCH TO
MATCH 0 NEW PIER
EXISTING ROOF
SYSTEM TO
REMAIN
i
2 WALL SECTION
A-1 SCALE: 1/2" = 1 -O"
NEW ROOF MEMBRANE FULLY
ADHERED
NEW 5/8" EXTERIOR GRADE
FIRE RETARDENT PLYWOOD
NEW 6" 18 GA. KICKERS 0
16" O.C. MAX
EXISTING ROOF
FRAMING TO
REMAIN
REMOVE EXISTING
ROOF MEMBRANE
WITHIN LIMITS OF
NEW SLOPED
ROOFING
ROOF MEMBRANEON 3" RIGID
INSULATION
PARAPET CAP BEYOND
EXISTING ROOF CONSTRUCTION TO
REMAIN - REMOVE EXIST. ROOF
MEMBRANE WITHIN LIMITS OF NEW
SLOPED ROOFING
EXISTING ROOF FRAMING TO
REMAIN
EXISTING CEILING TO REMAIN
EXISTING STEEL BEAM TO REMAIN
EXISTING 2x FRAMING AND
INSULATION TO REMAIN
EXISTING ALUMINUM STOREFRONT
AND GLAZJNG TO REMAIN
EXISTING SLAB TO REMAIN
ROOF MEMBRANE ON TAPERED 3" RIGID
INSULATION
CAP FLASHING BEYOND--------,,
I WALL SECTION
A -1 SCALE: 1/2* =, 1' -0"
WI6x26 (SEE STRUCTURAL DWGS)
4»x4" 18 GA. CONT. ANGLE
NEW ROOF MEMBRANE
3" RIGID INSULATION
5/8" EXTERIOR GRADE PLYWOOD f r f
f /
3 -5/8" 18 GA METAL
y
NW OTE I STUD 0 16" O.C. MAX r /
f /
NEW BATT INSUL TO
1. CONTRACTOR TO FIELD VERIFY ALL DIMENSIONS RUN 12" INTO VOID /
/
AND ELEVATIONS
00
EXISTING ROOF CONSTRUCTION TO -
REMAIN - REMOVE EXISTING ROOF
MEMBRANE WITHIN LIMITS OF NEW
SLOPED ROOFING
EXISTING ROOF FRAMING TO REMAIN
i
4 WALL SECTION
A -1 SCALE: t* = 1; -0*—
THREADED ROD PROVIDED
BY MANUFACTURER
CONCEALED IN TRELLIS
VERTICAL TUBE SEE:
STRUCTURAL DRAWINGS
TRELLIS UNIT BY
OTHERS
w�
o
cp
C C N
W C
C
�E�
an n
oQ i2
a�
c�
.0
Cfj
o�
Ira co
ov
CON9i LTANT:
FsEAL:
cvs/
pharmacy
STORE NUMBER: $8 �
1421 S. RANGE LINE ROAD
CApMEL, IN 4603
SQUARE FOOTAGE:
MAL 0101 AV*
WAL
FROU" AMA
a
M I%
WA
Rue"
"or.
REVISION$:
10/06/05: ISSUED FOR PERMIT
03/24/05: ISSUED FOR BIDOINls
MW KMACM BAK
PI.aaI#IINC,« WA c.�.
PRA" IST:
DA'L'E= I0/06/05
DRAWINt': W" AS NOTED
ME$
SECTIONS NOTES, & DETAILS
Aml
COMM