Loading...
HomeMy WebLinkAboutC80434.00" 2.00" 12.00" 20.00" ‘ 18.00" 15.00" 18.00"16.00" 30.00" 26.00" REMOVABLE WATERTIGHT ACCESS PORT, 10" OPENING 10.00" 1" PVC ANTI-SIPHON PIPE ADAPTER BMP, INC. 53 MT. ARCHER ROAD, LYME, CT. 06371 (800) 504-8008 FAX: (860)434-3195 DESCRIPTION DRAWING NUMBER DATE SCALE 24R SNOUT OIL & DEBRIS STOP 24R 09/13/99 NONE FRONT SIDE PLAN U.S.PATENT #6126817ADDITIONAL PATENTS PENDING &'5+)0'&61(+6 Ä&+#/ 5647%674'5 RECOMMENDED SUMP DEPTH 2.5 TO 3X OUTLET PIPE I.D. DESCRIPTION DRAWING NUMBER DATE SCALE ANTI-SIPHON DEVICE OIL- DEBRIS HOOD INSTALLATION REQUIREMENTS (TYPICAL) 04/13/05 NONE OUTLET PIPE SNOUT OIL-DEBRIS HOOD INSTALLATION REQUIREMENTS FOR SNOUT HOODS INSTALLED IN STORMWATER QUALITY IMPROVEMENT STRUCTURES MOUNTING FLANGE 1" PVC ANTI-SIPHON PIPE ADAPTER REMOVABLE WATERTIGHT ACCESS PORT, 6"-10" OPENING OUTLET PIPE (HIDDEN) CONFIGURATION DETAIL TYPICAL INSTALLATION FOAM GASKET W/ PSA BACKING (TRIM TO LENGTH) MOUNTING FLANGE DETAIL B GASKET COMPRESSED BETWEEN HOOD AND STRUCTURE (SEE DETAIL B) INSTALLATION NOTE: POSITION HOOD SUCH THAT BOTTOM FLANGE IS A DISTANCE OF 1/2 OUTLET PIPE DIAMETER (MIN.) BELOW THE PIPE INVERT. MINUMUM DISTANCE FOR PIPES < 12" I.D. IS 6". STAINLESS BOLT ANCHOR SHIELD EXPANSION CONE (NARROW END OUT) DRILLED HOLE DETAIL A 1/2 D INSTALLATION DETAIL INSPECTION REQUIREMENTS: 1. MANUFACTURER: ALL HOODS AND TRAPS FOR CATCH BASINS AND WATER QUALITY STRUCTURES SHALL BE PROVIDED BY: BEST MANAGEMENT PRODUCTS, INC. 53 MT. ARCHER RD. LYME, CT 06371 TOLL FREE: (800) 504-8008 OR (877) 434-3197 WEB SITE: www.bmpinc.com 2. CONFIGURATION: ALL HOODS SHALL BE EQUIPPED WITH A WATERTIGHT ACCESS PORT, A MOUNTING FLANGE, AND AN ANTI-SIPHON VENT AS DRAWN. (SEE CONFIGURATION DETAIL) 3. PIPE COVERAGE: THE SIZE OF THE HOOD SHALL PERMIT THE O.D. OF THE OUTLET PIPE TO BE COVERED COMPLETELY. 4. HOOD POSITION: THE BOTTOM OF THE HOOD SHALL EXTEND DOWNWARD A MINIMUM DISTANCE EQUAL TO 1/2 THE OUTLET PIPE I.D. WITH A MINIMUM DISTANCE OF 6" FOR PIPES <12" I.D. GREATER INSERTION DEPTH IS PERMISSIBLE. 5. ANTI-SIPHON VENT: VENT WITH ELBOW AND FEMALE ADAPTER SHALL EXTEND ABOVE HOOD BY MINIMUM OF 3" AND A MAXIMUM OF 24" ACCORDING TO STRUCTURE CONFIGURATION. 6. MOUNTING SURFACE PREPARATION: THE SURFACE OF THE STRUCTURE WHERE THE HOOD IS MOUNTED SHALL BE FINISHED SMOOTH AND FREE OF LOOSE MATERIAL. 7. SNOUT/SRUCTURE INTERFACE: THE HOOD SHALL BE SECURELY ATTACHED TO STRUCTURE WALL WITH 3/8' STAINLESS STEEL BOLTS. OIL-RESISTANT GASKET AS SUPPLIED BY MANUFACTURER MUST BE INSTALLED TO PROVIDE PROPER SEAL. (SEE DETAIL "B") 8. ACCESSORIES: IF OIL BOOMS OR FLOW DEFLECTORS ARE SPECIFIED, THEY MUST BE INSTALLED AND PRESENT FOR INSPECTION. 9. INSTALLATION INSTRUCTIONS: INSTRUCTIONS SHALL BE FURNISHED UPON REQUEST OF INSPECTOR WITH MANUFACTURER SUPPLIED INSTALLATION KIT. INSTALLATION KIT SHALL INCLUDE: A. INSTALLATION INSTRUCTIONS B. PVC ANTI-SIPHON VENT PIPE, FEMALE ADAPTER WITH NUT, O-RING GASKETS C. OIL-RESISTANT CRUSHED CELL FOAM GASKET WITH PSA BACKING D. 3/8" STAINLESS STEEL BOLTS E. ANCHOR SHIELDS (SEE BELOW FOR MULTI-PART SNOUTS 36F, 48F, 54R, 96F AND SPLIT SNOUTS ONLY) F. STAINLESS NUTS AND BOLTS PLUS GASKET TO SECURE TOP AND BOTTOM OF SNOUT. D FRONT VIEW SIDE VIEW INRQ-SN SNOUT OIL-WATER-DEBRIS SEPARATOR US Patent # 6126817 CANADIAN Patent # 2285146 *NOTE- SUMP DEPTH TO BE MIN. OF 2.5 TIMES THE OUTLET PIPE I.D. (E.G. 24" PIPE= 5' SUMP) 3' MIN FOR PIPES 12" I.D. OR LESS SEE NOTE* GASKET MUST BE VISIBLE BETWEEN SNOUT AND STRUCTURE WALL BOLTS TO BE POSITIONED UNIFORMLY AROUND PERIMETER OF SNOUT TO ENSURE OPTIMAL COMPRESSION OF GASKET DESCRIPTION DRAWING NUMBER DATE SCALE BMP, INC. 53 MT. ARCHER ROAD, LYME, CT. 06371 (800) 504-8008 FAX: (860)434-3195 SUSPENDED SOLIDS SETTLE ON BOTTOM OIL & FLOATABLE DEBRIS ON SURFACE CANNOT EXIT PIPE "SNOUT" OIL & DEBRIS STOP ANTI-SIPHON DEVICE SNOUT INLINE INSTALLATION 09/17/99 NONE SC-IN INFLOWOUTFLOW GRATE SNOUT U.S.PATENT #6126817 ADDITIONAL PATENTS PENDING DESCRIPTION DRAWING NUMBER DATE SCALE SOLIDS SETTLE ON BOTTOM ANTI-SIPHON DEVICE OIL- DEBRIS HOOD SPECIFICATION AND INSTALLATION (TYPICAL) 09/08/00 NONE OUTLET PIPE SNOUT OIL-DEBRIS HOOD HOOD SPECIFICATION FOR CATCH BASINS AND WATER QUALITY STRUCTURES MOUNTING FLANGE 1" PVC ANTI-SIPHON PIPE ADAPTER REMOVABLE WATERTIGHT ACCESS PORT, 6"-10" OPENING OUTLET PIPE (HIDDEN) CONFIGURATION DETAIL TYPICAL INSTALLATION FOAM GASKET W/ PSA BACKING (TRIM TO LENGTH) MOUNTING FLANGE DETAIL B GASKET COMPRESSED BETWEEN HOOD AND STRUCTURE (SEE DETAIL B) INSTALLATION NOTE: POSITION HOOD SUCH THAT BOTTOM FLANGE IS A DISTANCE OF 1/2 OUTLET PIPE DIAMETER (MIN.) BELOW THE PIPE INVERT. MINUMUM DISTANCE FOR PIPES < 12" I.D. IS 6". STAINLESS BOLT ANCHOR SHIELD EXPANSION CONE (NARROW END OUT) DRILLED HOLE DETAIL A ANCHOR W/ BOLT (SEE DETAIL A) 1/2 D INSTALLATION DETAIL NOTES: 1. ALL HOODS AND TRAPS FOR CATCH BASINS AND WATER QUALITY STRUCTURES SHALL BE AS MANUFACTURED BY: BEST MANAGEMENT PRODUCTS, INC. 53 MT. ARCHER RD. LYME, CT 06371 (860) 434-0277, (860) 434-3195 FAX TOLL FREE: (800) 504-8008 OR (888) 354-7585 WEB SITE: www.bestmp.com OR PRE-APPROVED EQUAL 2. ALL HOODS SHALL BE CONSTRUCTED OF A GLASS REINFORCED RESIN COMPOSITE WITH ISO GEL COAT EXTERIOR FINISH WITH A MINIMUM 0.125" LAMINATE THICKNESS. 3. ALL HOODS SHALL BE EQUIPPED WITH A WATERTIGHT ACCESS PORT, A MOUNTING FLANGE, AND AN ANTI-SIPHON VENT AS DRAWN. (SEE CONFIGURATION DETAIL) 4. THE SIZE AND POSITION OF THE HOOD SHALL BE DETERMINED BY OUTLET PIPE SIZE AS PER MANUFACTURER'S RECOMMENDATION. 5. THE BOTTOM OF THE HOOD SHALL EXTEND DOWNWARD A DISTANCE EQUAL TO 1/2 THE OUTLET PIPE DIAMETER WITH A MINIMUM DISTANCE OF 6" FOR PIPES <12" I.D. 6. THE ANTI-SIPHON VENT SHALL EXTEND ABOVE HOOD BY MINIMUM OF 3" AND A MAXIMUM OF 24" ACCORDING TO STRUCTURE CONFIGURATION. 7. THE SURFACE OF THE STRUCTURE WHERE THE HOOD IS MOUNTED SHALL BE FINISHED SMOOTH AND FREE OF LOOSE MATERIAL. 8. THE HOOD SHALL BE SECURELY ATTACHED TO STRUCTURE WALL WITH 3/8' STAINLESS STEEL BOLTS AND OIL-RESISTANT GASKET AS SUPPLIED BY MANUFACTURER. (SEE INSTALLATION DETAIL) 9. INSTALLATION INSTRUCTIONS SHALL BE FURNISHED WITH MANUFACTURER SUPPLIED INSTALLATION KIT. INSTALLATION KIT SHALL INCLUDE: A. INSTALLATION INSTRUCTIONS B. PVC ANTI-SIPHON VENT PIPE AND ADAPTER C. OIL-RESISTANT CRUSHED CELL FOAM GASKET WITH PSA BACKING D. 3/8" STAINLESS STEEL BOLTS E. ANCHOR SHIELDS OIL AND DEBRIS D FRONT VIEW SIDE VIEW SP-SN SNOUT OIL-WATER-DEBRIS SEPARATOR US Patent # 6126817 *NOTE- SUMP DEPTH OF 36" MIN. FOR < OR= 12" DIAM. OUTLET. FOR OUTLETS >OR= 15", DEPTH = 2.5-3X DIAM. SEE NOTE* DESCRIPTION DRAWING NUMBER DATE SCALE BMP, INC. 53 MT. ARCHER ROAD, LYME, CT. 06371 (800) 504-8008 FAX: (860)434-3195 VARIES "SNOUT" OIL/DEBRIS STOP BY BMP, INC. INSTALLED PER MFG. SPECIFICATION BOTTOM OF HOOD 1/2 PIPE I.D. BELOW INVERT OF PIPE (6" MIN.) SNOUT SIZING CHART 09/09/05 NONE SP-SI Ws Dp OUTLET PIPE DIAMETER (I.D.) RULE # 1- AT AN ABSOLUTE MINIMUM, STRUCTURE INTERNAL DIMENSIONS MUST BE AT LEAST LARGE ENOUGH TO ACCOMODATE EXTERNAL DIMENSIONS OF THE SNOUT, AND ALLOW FOR A PERSON TO INSTALL IT. REFER TO BMP, INC. CAD DETAILS FOR PART DIMENSIONS. RULE #2- USE ONLY "F" SERIES SNOUTS FOR RECTANGULAR OR SQUARE STRUCTURES, AVAILABLE IN 12", 18", 24", 30", 48", 72" AND 96" SIZES. USE ONLY "R" SERIES SNOUTS FOR ROUND STRUCTURES, AVAILABLE IN 12", 18", 24", 30", AND 54" SIZES. *SUMP DEPTH (Ds)- SUMP DEPTH SHOULD BE A MINIMUM OF 36" FOR ANY NEW CONSTRUCTION FOR PIPES 12" AND LESS. FOR 15"-18" PIPE MIN. DEPTH SHOULD BE 48". OPTIMAL SIZING IS AT LEAST 2.5X TO 3X OUTLET PIPE DIAMETER (Dp) FOR MAXIMUM POLLUTANT REMOVAL EFFICIENCY AND MINIMAL CLEANOUT FREQUENCY. STRUCTURE DIMENSIONS- PLAN DIMENSIONS FOR A STRUCTURE SHOULD BE UP TO 7X AREA OF OUTLET PIPE FOR MAXIMUM POLLUTANT REMOVAL EFFICIENCY AND MINIMAL CLEANOUT FREQUENCY. (SEE "MAINTENANCE CONSIDERATIONS" DOCUMENT FOR MORE INFORMATION) IMPORTANT NOTICE: DO NOT CONFUSE PIPE O.D WITH PIPE I.D. A SNOUT FITS OVER A PIPE, NOT IN IT. THUS, SNOUT MUST BE SIZED TO FIT OVER PIPE OPENING IN STRUCTURE. SNOUTS ARE AVAILABLE FOR ROUND STRUCTURES TO ACCOMODATE PIPES OF 54" O.D. MAX. FOR PIPES 54" O.D. AND ABOVE, USE SQUARE OR RECTANGULAR STRUCTURES. SIZING EXAMPLES: OUTLET HOLE SIZE SNOUT SIZE 11.9" O.D. OR LESS 12 F or R (R FITS 36"-48" DIAM STRUCTURE) 12.0"-17.9" O.D. 18 F or R (R FITS 48"-60" DIAM STRUCTURE) 18.0"-23.9" O.D. 24 F or R (R FITS 48"-60" DIAM STRUCTURE) 24.0"-29.9" O.D. 30 F or R (R FITS 60"-72" DIAM STRUCTURE) 30.0"-35.9" O.D. 36F 30.0"-47.9" O.D. 48 F 30.0"-53.9" O.D. 54R/72 (FITS 72" DIAM STRUCTURE ONLY) 48.0"-71.9" O.D. 72F 72"-95.9" O.D. 96 F WIDTH OF STRUCTURE ANTI-SIPHON VENT STACK SIZED ACCORDING TO TOP OF STRUCTURE OR GRATE. 3" MIN. HEIGHT. Ds 36.00" MIN.* DESIGN PARAMETER GUIDELINES FOR WATER QUALITY IMPROVEMENT