06020015 Carmel Arts Building Mechanical Plans (18in x 13in reduced prints) issue date 3/10/06
CD CL Cr M Du cn CD M cc =F (D (D 00 NORTH FIRST FLOOR HVAC PLAN X TAG XX CFM 45' TYPICAL SPIRAL DUCT MOOUNTED REGISTER DETAIL Mt.t N.T.S GENERAL NOTES - I 1. ALL EXPOSED ROUND DUCT TO BE GASKET SPIRAL AS MANUFACTURED BY LINDAB (OR EQUAL). 2. ALL OUTSIDE AIR DUCT TO BE INSULATED WITH 11" FSK DUCT WRAP. 3. PROVIDE FLEXIBLE DUCT CONNECTORS ON SUPPLY AIR FAN COIL CONNECTIONS. 4. ALL DUCTWORK TO BE PER SMACNA 1" PRESSURE CLASS, SEAL CLASS C. 5. PROVIDE MANUAL VOLUME DAMPERS WITH LOCKING QUADRANT HANDLES ON ALL BRANCH LINES TO ALLOW SYSTEM TO BE COMPLETELY BALANCED. 6. COORDINATE FINAL LOCATIONS OF ALL DEVICES WITH ARCHITECTS REFLECTED CEILING PLAN AND OTHER TRADES. 7. MAXIMUM LENGTH OF FLEXIBLE DUCT NOT TO EXCEED 10' -0 ". KEYNOTES Ot PROVIDE MOTORIZED OUTDOOR AIR DAMPER INTERLOCK TO BLOWER. 2O PROVIDE 21/20 TO 14/20 LINED REDUCING 90 ON RETURN AIR OPENING. SCREEN INTAKE WITH WIRE MESH. MECHANICAL SYMBOL SCHEDULE [fl]A MOTORIZED OUTDOOR AIR DAMPER -� MANUAL AIR BALANCING DAMPER 8 ELECTRIC THERMOSTAT C= FIRE DAMPER ® SUPPLY AIR GRILLE zRETURN AIR GRILLE ® EXHAUST AIR GRILLE FL FAN LIGHT COMBO BY E.C. ACCU— AIR COOLED CONDENSING UNIT CH— CABINET UNIT HEATER D— DIFFUSER EF— EXHAUST FAN EG— EXHAUST GRILLE F— FURNACE HVAC— HEATING VENTILLATION AIR CONDITIONING UNIT MAU— MAKE UP AIR UNIT L— LOUVER RAD— RADIANT HEATER RF— RELIEF FAN RG— RETURN AIR GRILLE TG— TRANSFER AIR GRILLE UH— UNIT HEATER A.F.F. ABOVE FINISHED FLOOR XX "xXX" RECTANGULAR DUCT Xm ROUND DUCT BV BRICK VENT COLOR BY ARCH. N Drawn By H 03/10/06 DW DG �s W CS z Ir a ~ J r r^ v J era F O V) V Mechanical Engineers GY��Gooderum and Associates 874 Cheltenham Way Avon, Indiana 46123 Phone: (317) 506 -8151 Fox: (317) j45 -5761 ENGINEERING Structural Engineers LYNCH, HARRISON, BRUMLEVE 550 Virginia Avenue Indianapolis, Indiana 46203 (317) 706 -2075 1- ry Q r Z W J w � Q � Q � U Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical syslems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contructars shall furnish all items required for the proper execution and completion of the work Drawing Title: FIRST FLOOR HVAC PLAN Revisions: Issue Date Drawn By Checked By 03/10/06 DW DG Certified By. \e \ \eµtl li l I I I I I n l n f f llll�lll� 3qt No. 10200395] VAT[ IF l ' , V \y f 1U1NA 111111Pn;iteVAPA Drawing Number. M101 Project Number. 25429 r-r a vQ M r* CD 1 3 M cc -3, CD CD cc N Drawn By H 03/10/06 DW DG x w C8 f--i 1;,;, W R V x J;; Un F �o V J V Mechanical Engineers GY6Gooderum and Associates 874 Cheltenham Way Avon, Indiana 46123 Phone: (317) 506 -8151 ENGINEERING Fax: (317) 145 -5761 Structural Engineers LYNCH, HARRISON, BRUMLEVE 550 Virginia Avenue Indianapolis, Indiana 46203 (317) 706 -2075 ry Q ry Z ___J Q Iz Q � U Scope Drawings: These drawings indicate the general scope of the project in terms of arch,tectural design concept, the dimensions of the building, the major architeclurol elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contructors shall furnish all items required for the Proper execution and completion of the work, Drawing Title: SECOND FLOOR HVAC PLAN Revisions: Issue Date Drawn By Checked By 03/10/06 DW DG Certified By �a, \ \ \N \N\11NI11111 I IIII �Illll4 r �r q� Nor 10200395- a sTea W I llll�l�1111111111\ Drawing Number. M102 Project Number. 25429 r-« CD a �G M W Cn - fD 3 CD rn cc ID THIRD FLOOR NORTH HVAC PLAN 1 /4' = 1'-0' GENERAL NOTES 1. ALL ROUND DUCT TO BE WRAPPED WITH 1 -1/2" FSK DUCT WRAP. 2. PROVIDE FLEXIBLE DUCT CONNECTORS ON SUPPLY AIR DUCT CONNECTIONS TO FAN COIL UNITS. 3. ALL DUCTWORK TO BE PER SMACNA 1" PRESSURE CLASS, SEAL CLASS C. 4. PROVIDE MANUAL VOLUME DAMPERS WITH LOCKING QUADRANT HANDLES ON ALL BRANCH LINES TO ALLOW SYSTEM TO BE COMPLETELY BALANCED. 5. COORDINATE FINAL LOCATIONS OF ALL DEVICES WITH ARCHITECTS REFLECTED CEILING PLAN AND OTHER TRADES. 6. MAXIMUM LENGTH OF FLEXIBLE DUCT NOT TO EXCEED 10' -0 ". KEYNOTES O PROVIDE 4" ALUMINUM DRYER VENT PIPE. ROUTE PIPE UP WALL AND THROUGH ROOF. TERMINATE WITH GOOSENECK TOPPER. 0 6" 0 BLOWER. rOUTE INSULATED FRESH AIR DUCT UP THROUGH ROOF. TERMINATE WITH RAIN PROOF TOPPER. MECHANICAL SYMBOL SCHEDULE F� MOTORIZED OUTDOOR AIR DAMPER —� MANUAL AIR BALANCING DAMPER Q ELECTRIC THERMOSTAT © FIRE DAMPER ® SUPPLY AIR GRILLE zRETURN AIR GRILLE ® EXHAUST AIR GRILLE FL EXHAUST/LIGHT COMBINATION FIXTURE BY E.C. ACCU— AIR COOLED CONDENSING UNIT CH— CABINET UNIT HEATER D— DIFFUSER EF— EXHAUST FAN EG— EXHAUST GRILLE F— FURNACE HVAC— HEATING VENTILLATION AIR CONDITIONING UNIT MAU— MAKE UP AIR UNIT L— LOUVER RAD— RADIANT HEATER RF— RELIEF FAN RG— RETURN AIR GRILLE TG— TRANSFER AIR GRILLE UH— UNIT HEATER A.F.F. ABOVE FINISHED FLOOR XX "xXX" RECTANGULAR DUCT X0 ROUND DUCT N ii-i-wil Drawn By and Associates GY6Gooderum 874 Cheltenham Way Avon, Indiana 46123 ENGINEERING W W W F O c� U Mechanical Engineers Drawn By and Associates GY6Gooderum 874 Cheltenham Way Avon, Indiana 46123 ENGINEERING Phone: (317 506 -8151 Fax: (317) 145 -5761 Structural Engineers LYNCH, HARRISON, BRUMLEVE 550 Vlrginla Avenue Indianapolis, Indiana 46203 (317) 706 -2075 i-- Q n-, z � w w � w Q af Q U U Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept. the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or descr,bed, the trade contractors shall furnish all items required for the proper e.ecution and completion of the work, Drawing Title: THIRD FLOOR NORTH HVAC PLAN Revisions: Issue Date Drawn By Checked By 03/10/06 DW DG Certified By. `.,e \1e,Ne n 11111 full rrel /r o��p1 -9 qQ No,# 10200395= i Ill ar Drawing Number: M103 Project Number. 25429 r-r a Cr M 03 CD 3 CD (D :3. A GENERAL NOTES 1. ALL ROUND DUCT TO BE WRAPPED WITH 1 -1/2" FSK DUCT WRAP. 2. PROVIDE FLEXIBLE DUCT CONNECTORS ON SUPPLY AIR DUCT CONNECTIONS TO FAN COIL UNITS. 3. ALL DUCTWORK TO BE PER SMACNA 1" PRESSURE CLASS, SEAL CLASS C. 4. PROVIDE MANUAL VOLUME DAMPERS WITH LOCKING QUADRANT HANDLES ON ALL BRANCH LINES TO ALLOW SYSTEM TO BE COMPLETELY BALANCED. 5. COORDINATE FINAL LOCATIONS OF ALL DEVICES WITH ARCHITECTS REFLECTED CEILING PLAN AND OTHER TRADES. 6. MAXIMUM LENGTH OF FLEXIBLE DUCT NOT TO EXCEED 10' -0". KEYNOTES O PROVIDE 4" ALUMINUM DRYER VENT PIPE. ROUTE PIPE UP WALL AND THROUGH ROOF. TERMINATE WITH GOOSENECK TOPPER. 2O 6" 0 BLOWER. rOUTE INSULATED FRESH AIR DUCT UP THROUGH ROOF. TERMINATE WITH RAIN PROOF TOPPER. MECHANICAL SYMBOL SCHEDULE 1i� MOTORIZED OUTDOOR AIR DAMPER --J MANUAL AIR BALANCING DAMPER Q ELECTRIC THERMOSTAT © FIRE DAMPER ® SUPPLY AIR GRILLE zRETURN AIR GRILLE ® EXHAUST AIR GRILLE FL EXHAUST/LIGHT COMBINATION FIXTURE BY E.C. ACCU— AIR COOLED CONDENSING UNIT CH— CABINET UNIT HEATER D— DIFFUSER EF— EXHAUST FAN EG— EXHAUST GRILLE F— FURNACE HVAC— HEATING VENTILLATION AIR CONDITIONING UNIT MAU— MAKE UP AIR UNIT L— LOUVER RAD— RADIANT HEATER RF— RELIEF FAN RG— RETURN AIR GRILLE TG— TRANSFER AIR GRILLE UH— UNIT HEATER A.F.F. ABOVE FINISHED FLOOR XX "xXX" RECTANGULAR DUCT X0 ROUND DUCT N Drawn By H GY�� W ENGINEERING Phone: (317) 506 -8151 Fax: (317) j45 -5761 W W � CS z I� Ilk W ,,U^ `.�) $ F O V) U Mechanical Engineers Drawn By Gooderum and Associates GY�� 874 Cheltenham Way Avon, Indiana 46123 ENGINEERING Phone: (317) 506 -8151 Fax: (317) j45 -5761 Structural Engineers LYNCH, HARRISON, BRUMLEVE 550 Virginia Avenue Indianapolis, Indiana 46203 (317) 706 -2075 Ii-- Q r z J W W w � Q :2 Q � U U Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe aft work required for full performance and completion of the requirements of the Conlrort. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution rind completion of the work. i Drawing Title: THIRD FLOOR SOUTH HVAC PLAN Revisions: Issue Date Drawn By Checked By 03/10/06 DW DG Certified By. . \ *� 10200395; FrAT[ it "fill, ii,110 Drawing Number: M104 Project Number. 25429 CD CL Cr �G M C CD 3 cc CD CD co 4 GENERAL NOTES 1. ALL ROUND DUCT TO BE WRAPPED WITH 1-1/2" FSK DUCT WRAP. 2. PROVIDE FLEXIBLE DUCT CONNECTORS ON SUPPLY AIR DUCT CONNECTIONS TO FAN COIL UNITS. 3. ALL DUCTWORK TO BE PER SMACNA 1" PRESSURE CLASS, SEAL CLASS C. 4. PROVIDE MANUAL VOLUME DAMPERS WITH LOCKING QUADRANT HANDLES ON ALL BRANCH LINES TO ALLOW SYSTEM TO BE COMPLETELY BALANCED. 5. COORDINATE FINAL LOCATIONS OF ALL DEVICES WITH ARCHITECTS REFLECTED CEILING PLAN AND OTHER TRADES. 6. MAXIMUM LENGTH OF FLEXIBLE DUCT NOT TO EXCEED 10 -0 . KEYNOTES O PROVIDE 4" ALUMINUM DRYER VENT PIPE. ROUTE PIPE UP WALL AND THROUGH ROOF. TERMINATE WITH GOOSENECK TOPPER. O 6" 0 BLOWER. rOUTE INSULATED FRESH AIR DUCT UP THROUGH ROOF. TERMINATE WITH RAIN PROOF TOPPER. MECHANICAL SYMBOL SCHEDULE MOTORIZED OUTDOOR AIR DAMPER J MANUAL AIR BALANCING DAMPER Q ELECTRIC THERMOSTAT © FIRE DAMPER ® SUPPLY AIR GRILLE zRETURN AIR GRILLE ® EXHAUST AIR GRILLE 7L EXHAUST/LIGHT COMBINATION FIXTURE BY E.C. ACCU— AIR COOLED CONDENSING UNIT CH— CABINET UNIT HEATER D— DIFFUSER EF— EXHAUST FAN EG— EXHAUST GRILLE F— FURNACE HVAC— HEATING VENTILLATION AIR CONDITIONING UNIT MAU— MAKE UP AIR UNIT L— LOUVER RAD— RADIANT HEATER RF— RELIEF FAN RG— RETURN AIR GRILLE TG— TRANSFER AIR GRILLE UH— UNIT HEATER A.F.F. ABOVE FINISHED FLOOR XX "xXX" RECTANGULAR DUCT X0 ROUND DUCT N Drawn By H 03/10/06 W DG x � W W a� C8 Z a� U 4 F O cn U Mechanical Engineers Gooderum and Associates 874 Cheltenham W' Avon, Indiana 46123 Phone: (317) 506— 81 51 Fax: (317) 745 -5761 ENGINEERING Structural Engineers LYNCH, HARRISON, BRUMLEVE 550 Virginia Avenue Indianapolis, Indiana 46203 (317) 706 -2075 F— Q r z W W J w CIL, Q � Q � U U Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contrart. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution rind completion of the work. Drawing Title: FOURTH FLOOR NORTH HVAC PLAN Revisions: Issue Date Drawn By Checked By 03/10/06 DIN DG Certified By. �}�� rGVU�4grHi ♦— �ey'� �qQ No. 10200395, sretE ' 2 Drawing Number. M105 Project Number. 25429 rF cna Q M r� (D 3 M CD CD t0 W GENERAL NOTES 1. ALL ROUND DUCT TO BE WRAPPED WITH PROVIDE 4" ALUMINUM DRYER VENT PIPE. 1 -1/2" FSK DUCT WRAP. ROUTE PIPE UP WALL AND THROUGH ROOF. 2. PROVIDE FLEXIBLE DUCT CONNECTORS ON TERMINATE WITH GOOSENECK TOPPER. SUPPLY AIR DUCT CONNECTIONS TO FAN ROUTE 6 "0 INSULATED FRESH AIR DUCT UP COIL UNITS. THROUGH ROOF. TERMINATE WITH RAIN 3. ALL DUCTWORK TO BE PER SMACNA 1 of PROOF TOPPER. PRESSURE CLASS, SEAL CLASS C. PROVIDE ELEVATOR VENT MINIMUM 3FT2 WITH 4. PROVIDE MANUAL VOLUME DAMPERS WITH MOTORIZED FIRE AND SMOKE DAMPER. LOCKING QUADRANT HANDLES ON ALL DAMPER TO OPEN ON SMOKE DETECTION BRANCH LINES TO ALLOW SYSTEM TO BE SIGNAL FROM FIRE PANEL. WIRING BY E.C. COMPLETELY BALANCED. 5. COORDINATE FINAL LOCATIONS OF ALL x DEVICES WITH ARCHITECTS REFLECTED CEILING C4 14 PLAN AND OTHER TRADES. 6. MAXIMUM LENGTH OF FLEXIBLE DUCT NOT TO EXCEED 10 -0 ". KEYNOTES O PROVIDE 4" ALUMINUM DRYER VENT PIPE. H ROUTE PIPE UP WALL AND THROUGH ROOF. W TERMINATE WITH GOOSENECK TOPPER. O2 ROUTE 6 "0 INSULATED FRESH AIR DUCT UP THROUGH ROOF. TERMINATE WITH RAIN W PROOF TOPPER. O PROVIDE ELEVATOR VENT MINIMUM 3FT2 WITH CS MOTORIZED FIRE AND SMOKE DAMPER. z DAMPER TO OPEN ON SMOKE DETECTION W SIGNAL FROM FIRE PANEL. WIRING BY E.C. MECHANICAL SYMBOL SCHEDULE [A�] MOTORIZED OUTDOOR AIR DAMPER —J MANUAL AIR BALANCING DAMPER Q ELECTRIC THERMOSTAT © FIRE DAMPER ® SUPPLY AIR GRILLE zRETURN AIR GRILLE ® EXHAUST AIR GRILLE FL EXHAUST/LIGHT COMBINATION FIXTURE BY E.C. ACCU— AIR COOLED CONDENSING UNIT CH— CABINET UNIT HEATER D— DIFFUSER EF— EXHAUST FAN EG— EXHAUST GRILLE F— FURNACE HVAC— HEATING VENTILLATION AIR CONDITIONING UNIT MAU— MAKE UP AIR UNIT L— LOUVER RAD— RADIANT HEATER RF— RELIEF FAN RG— RETURN. AIR GRILLE TG— TRANSFER AIR GRILLE UH— UNIT HEATER A.F.F. ABOVE FINISHED FLOOR XX "xXX" RECTANGULAR DUCT X0 ROUND DUCT N Drawn By H 03/10/06 W DG W W � CS z aA W x C4 14 0 V) U Mechanical Engineers Gooderum and Associates 874 Cheltenham Way GY6 Avon, Indiana 46123 Phone: (317 506 -8151 ENGINEERING Fox: (317) 45 -5761 Structural Engineers LYNCH, HARRISON, 13RUMLEVE 550 "' 'g to Avenue Indianapolis, Indiana 46203 (317) 706 -2075 Q � z � W W � w � Q ME Q CD U U Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the maiar architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper e.ecution and completion of the work. Drawing Title: FOURTH FLOOR SOUTH HVAC PLAN Revisions: I Issue Date Drawn By Checked By 03/10/06 DW DG Certified Byr 0etatl 611, lllllli 4jN r GAD 0. E 1102003951 Drawing Number. M106 Project Number. 25429 FWww- -0 CD CL Cr M a) CD :3 M :3 cc 5, CD CD _X Mechanical Engineers Gooderum and Associates 874 Cheltenham Way Avon, Indiana 46123 Phone: 17� 506-8151 Fax: (319 ) 45-5761 ENGINEERING Structural Engineers LYNCH, HARRISON, 13RUMLEVE 550 Virginia Avenue Indianapolis, Indiana 46203 (317) 706-2075 w< ry W J w ME < ry < Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the budding, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do i•ot necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade I. ontructors shall furnish all items required for the proper execution and completion of the work. —J Drawing Title: ROOF LEVEL HVAC PLAN Revisions: Issue Data Drawn By Checked By 03/10/06 DW DG C8 J;-; U V) In U Mechanical Engineers Gooderum and Associates 874 Cheltenham Way Avon, Indiana 46123 Phone: 17� 506-8151 Fax: (319 ) 45-5761 ENGINEERING Structural Engineers LYNCH, HARRISON, 13RUMLEVE 550 Virginia Avenue Indianapolis, Indiana 46203 (317) 706-2075 w< ry W J w ME < ry < Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the budding, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do i•ot necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade I. ontructors shall furnish all items required for the proper execution and completion of the work. —J Drawing Title: ROOF LEVEL HVAC PLAN Revisions: Issue Data Drawn By Checked By 03/10/06 DW DG Certified By: G No, =10200395 8TATE IF Drawing Number. M107 Project Number. 25429 CD Cr M 2) CD (D CD EQUIPMENT SCHEDULE TAG MANUF. MODEL HEATING CAPACITY COOLING CAPACITY CFM ESP O.A. VOLTAGE MCA MOCP ACCESSORIES/ KW STAGE TONS SEER (IN, W,C,) REMARKS FCU -1 LENNOX CB28UH- 048 - 230 -02 15 1 -- -- 1,605 0,40 320 208/230/3 45 45 00 FCU -2 LENNOX CB28UH- 048 - 230 -02 15 1 -- -- 1,605 0.40 320 208/230/3 45 45 0 0 FCU -3 LENNOX CB28UH- 048 - 230 -02 15 1 -- -- 1,605 •0,40 320 208/230/3 45 45 0 0 FCU -4 LENNOX CB28UH- 048 - 230 -02 15 1 -- -- 1,605 0.40 320 208/230/3 45 45 01 O2 FCU -5 LENNOX CB28UH- 048 - 230 -02 15 1 -- -- 1,605 0.40 320 208/230/3 45 45 0 O2 FCU -6 LENNOX CB28UH- 048 - 230 -02 CB28UH- 048 - 230 -02 15 15 1 1 1 -- -- -- -- -- -- 1,605 1,605 1,990 0,40 0.40 0.40 320 320 400 208/230/3 208/230/3 208/230/3 45 45 (32/21) 45 45 (35/30) 0 0 00 DUAL CIRCUITS O1 FCU-7 LENNOX FCU -8 LENNOX CB28UH- 060 - 230 -02 20 FCU -9 LENNOX CB30M -31 -4P 10 1 -- -- -- -- 945 1,335 0,40 0,40 0 150 208/230/1 208/230/1 47 (24/37) 50 (25/50) 00 DUAL CIRCUITS (Do FCU -10 LENNOX CB30M -41 -4P 15 1 FCU -11 LENNOX CB30M -31 -4P 10 1 1 1 1 -- -- -- -- -- -- -- -- 945 1,335 945 1,335 0,40 0,40 0,40 0,40 0 150 0 150 208/230/1 208/230/1 208/230/1 208/230/1 47 (24/37) 47 (24/37) 50 (25/50) 50 (25/50) 1 3 DUAL CIRCUITS OO O0 DUAL CIRCUITS O1 0 FCU -12 LENNOX CB30M -41 -4P CB30M -31 -4P 15 10 15 FCU -13 LENNOX FCU -14 LENNOX CB30M -41 -4P 10 1 -- -- 945 0,40 0 208/230/1 47 50 00 FCU -15 LENNOX CB30M -31 -4P FCU -16 LENNOX CB30M -41 -4P 15 1 -- -- 1,335 0,40 150 208/230/1 (24/37) (25/50) DUAL CIRCUITS 00 ACCU -1 LENNOX HP29- 048 -7Y 44,500 44,500 -- -- -- 4 4 4 10,2 10.2 10,2 -- -- -- -- -- -- -- -- -- 208/230/3 208/230/3 208/230/3 18,8 18.8 18.8 30 30 30 0 0 0 ACCU -2 LENNOX HP29- 048 -7Y ACCU -3 LENNOX HP29- 048 -7Y 44,500 ACCU -4 LENNOX HP29- 048 -7Y 44,500 -- 4 10,2 -- -- -- 208/230/3 18.8 30 O ACCU -5 LENNOX HP29- 048 -7Y 44,500 -- 4 102 -- -- -- 208/230/3 18,8 30 0 ACCU -6 LENNOX HP29- 048 -7Y 44,500 -- 4 10,2 -- -- -- 208/230/3 18,8 30 0 ACCU -7 LENNOX HP29- 048 -7Y 44,500 -- 4 10,2 -- -- -- 208/230/3 18.8 30 0 ACCU -8 LENNOX HP29- 060 -7Y 56,000 29,200 -- -- 5 2.5 8,9 14 -- -- -- -- -- -- 208/230/3 208/230/1 23,5 18.7 40 30 0 0 ACCU -9 LENNOX XP13- 030 -230 ACCU -10 LENNOX HPXA16- 036 -230 34,400 -- 3 14,8 -- -- -- 208/230/1 22,1 35 0 ACCU -11 LENNOX XP13- 030 -230 29,200 -- 2.5 14 -- -- -- 208/230/1 18.7 30 0 ACCU -12 LENNOX HPXA16- 036 -230 34,400 -- 3 14,8 -- -- -- 208/230/1 22.1 35 0 ACCU -13 LENNOX XP13- 030 -230 29,200 -- 2,5 14 -- -- -- 208/230/1 18,7 30 0 ACCU -14 LENNOX HPXA16- 036 -230 34,400 -- 3 14,8 -- -- -- 208/230/1 22.1 35 0 ACCU -15 LENNOX XP13- 030 -230 29,200 34,400 -- -- 2.5 3 14 14.8 -- -- -- -- -- -- 208/230/1 208/230/1 18,7 22.1 30 35 0 0 ACCU -16 LENNOX HPXA16- 036 -230 O PROVIDE DIGITAL THERMOSTAT. PROVIDE O2 PROVIDE SECONDARY DRAIN PAN AND SCD -4C -- A618MS A61SMS A618MS 12/12 -- 14/6 16/8 16/10 AS LISTED AS LISTED 12/4 14/6 14/8 MANUFACTURER RETURN AIR FILTER RACK. VIBRATION ISOLATION HANGERS. DRYWALL DRYWALL DRYWALL DRYWALL DRYWALL PLSTR FRAME - -- - -- - -- - -- ACCESSORIES/ O3 PROVIDE APRILAIRE MODEL 700 POWER O PROVIDE LOW AMBIENT KITS, CRANCASE S-6 R-1 PRICE R-2 HART & COOLEY 530 RH45 HUMIDIFIER AND INSTALL PER HEATERS, AND TXV KITS. ALUM. STEEL AS LISTED AS LISTED LAYIN DRYWALL MANUFACTURERS INSTRUCTIONS. CSP -A510 464 0.25 115/1 AIR DEVICE SCHEDULE ELECTRIC WALL HEATER TAG MANUF, MODEL FACE NECK MATERIAL CFM MOUNTING ACCESSORIES/ TAG MANUF. MODEL WATTS VOLTAGE BTU /HR AMPS MOUNTING ACCESSORIES/ STYLE REMARKS RECESSED SIZE SIZE STYLE REMARKS PHASE S -1 LINDAB RGS -3 13/3 AS LISTED ALUM, AS LISTED DUCT - -- EWH -1 QMARK AWH -44083 4000 208/3 13,650 11.1 RECESSED TMPR PRF T/S S -2 S -3 PRICE -- HART & COOLEY HART & COOLEY HART & COOLEY SCD -4C -- A618MS A61SMS A618MS 12/12 -- 14/6 16/8 16/10 AS LISTED AS LISTED 12/4 14/6 14/8 STEEL STEEL ALUM. ALUM, ALUM. AS LISTED AS LISTED AS LISTED AS LISTED AS LISTED DRYWALL DRYWALL DRYWALL DRYWALL DRYWALL PLSTR FRAME - -- - -- - -- - -- ACCESSORIES/ S-4 S-5 S-6 R-1 PRICE R-2 HART & COOLEY 530 RH45 AS LISTED -- AS LISTED AS LISTED ALUM. STEEL AS LISTED AS LISTED LAYIN DRYWALL - -- - -- CSP -A510 EXHAUST FANS TAG MANUF, MODEL CFM TSP VOLTAGE AMPS MOUNTING ACCESSORIES/ PHASE STYLE REMARKS EF -1 GREENHECK CSP -A510 464 0.25 115/1 3.11 RECESSED COOLNG T/S EF -2 GREENHECK SP -B70 57 0.25 115 /1 0.53 RECESSED I N 1 H �D V) w �z C8 �+ 8 Z^ Rix �F 0 U Mechanical Engineers GY��Gooderum and Associates 874 Cheltenham way Avon, Indiana 46123 Phone: (317 ) 506 -8151 Fax: (317) 45 -5761 ENGINEERING Structural Engineers LYNCH, HARRISON, BRUMLEVE 550 Virginia Avenue Indianapolis, Indiana 46203 (317) 706 -2075 f -- <C � z J L1J LJJ J L,J � Q � Q � U U � Scope Drawings: These drawings indicate the general scope of the project in terms of architectural design concept, the dimensions of the building, the major architectural elements and the type of structural, mechanical and electrical systems. The drawings do not necessarily indicate or describe all work required for full performance and completion of the requirements of the Contract. On the basis of the general scope indicated or described, the trade contractors shall furnish all items required for the proper execution and completion of the work. Drawing Title: HVAC SCHEDULES Revisions: Issue Date Drawn By Checked By 03/10/06 DW DG Certified By. 3AQ No.�* 10200395= VATS [IF Drawing Number. M201 Project Number. 25429 IJ