HomeMy WebLinkAbout06010009.11SANI. MANHOLE
TC= 911.50'
IE E(8'PVC)= 904.70'
RENEGADE COURT SANI. MANHOLE
TC Q10'in
RENEGADE COURT (50' RA) IE E(8'PVC)= 903.20'
IE W(8'PVC)= 903.28'
I � I
I
I � 1
I � '
'o
I
TC= 907.08' I �.
w IW � ! TC= 906.87'
� ) TC =90 18' — ;10 CJ I I
909 1 V I 90B
908
907
--�--90--6�
0904, .0
o soh o
25' D. do U.E. g0`.!`
38
J�
37 0'
� 906
ti
J
w �
12' 52RM
� � J
IM
IM
W
N
I °
__J /
905 /
1
9�
15 STORM
o'
t
35
g0 �
34
Ci
33 vi
i
32
i
0
aW
CV
905
908
i 904 I
905
/ 2•
39 905
/
66NSERVA LNOT
TREE PRESERVATION AREA \ 906 9aLL�-- 12' sro
DECK \
?p� BLOCK A SCREENED
SS I t PORCH
12 ST h 1J i{ 2– STORY, WOOD FRAME
o do STONE Wr H PART.
BASEMENT
2288 -j
i
d
15'
N J - - --
20' S.S.,D. & U.E. /
O6 r
WINS OW VIEW ID VE
,* 115.57
f 15' -90F4- - -
12' '1
15' si 20' S.S.,D .& U.E. °5 20' S.S„D.- *-U.E.
--
23 904
STORM n28
w
•pig
MT!
22
2T
20
18' ORM
I
9�J
90,E
Ad
0
Vi
N
10 N
N
12
w
w
W
40
CONSERVATION LOT
o"'
0
12'
/ I.
TC= 902.82'
C
/
a
MATCHLINE SHEET C502
o C1
C1 N
N Z
IN 0
wt
d
Li
vi
0
O 0
0
"HOLEY MOLEY " SAYS CALL AT LEAST TWO FULL
WORKING DAYS BEFORE YOU DIG IT'S THE LAW
0
1 -800- 382 -5544
CALL TOLL FREE
1 -800- 428 -5200
FOR CALLS OUTSIDE OF INDIANA
CAUTION
LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
SHOWN ON THIS PLAN ARE BASED UPON ABOVE
GROUNU EVIDENCE (including, but not limited to,
monholrs, inlets, valves, and marks made upon
the ground by others) AND ARE SPECULATIVE IN
NATURE THERE MAY ALSO BE OTHER EXISTING
UNDERGROUND UTILITIES FOR WHICH THERE IS NO
ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE
GROUND EVIDENCE WAS OBSERVED. THE EXACT
LOCATIONS OF SAID EXISTING UNDERGROUND
UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR 10 ANY AND ALL CONSTRUCTION.
1.1
UTLITY PLAN LEQEM
PROPM CONSTRUM ON
SANRARY SEWER
SANITARY CLEANOUT co
SANITARY LATERAL SANITARY MANHOLE
SANITARY LINE S
SANITARY STRUCTURE NUMBER 501
TC 715.50
SANITARY CASTING ELEVATION
_
EASEMENT LINE —
SANITARY SEWER EASEMENT S.S.E.
SANITARY SEWER, DRAINAGE S.S.,D.& U.E.
do UTILITY EASEMENT
o
STORM SEWER
CURB WITH SUBSURFACE DRAIN (SSD)
CURB INLETS
STORM SEWER INLETS OL
z_
U CD
STORM MANHOLE
z
c� O
END SECTION
r�
0
STORM SEWER STRUCTURE NUMBER 500
ozz<
I<<w
IE: 715.50
STORM SEWER INVERT ELEVATION
rn
r
TOP OF CASTING ELEVATION TC: 715.50
L
N �
SWALE WITH SUBSURFACE DRAIN (SSD) _ _ _ =WEE W /SSD ®0.70% —
a - -- --
WATER
ZQ M a
WATER LINE W W
= Z Q Q
WATER VALVE ►�
cl� (n U
PROPOSED FIRE HYDRANT Ak
CN
WATER METER
I
r Q w
PROPOSED BLOW OFF ASSEMBLY 0 B.O.
00
PROPOSED REDUCER LA
PROPOSED 'TEE' w
PROPOSED 45' ELBOW
c
7,`
PROPOSED 90' ELBOW
W
06
PROPOSED 22' ELBOW 221
- U
PROPOSED 11' ELBOW 1194
Q
ELECTRIC
OVERHEAD ELECTRIC E E
BURIED ELECTRIC BEC BEC
ELECTRIC MANHOLE O
V
POWER POLE
GUY WIRE
TRANSFORMER
ELECTRIC PEDESTAL
CD
GUY POLE 0
CD
ELECTRIC METER Q
STREET LIGHT
o�
STREET LIGHT '
C
AREA LIGHT
� °-
FLOOD LIGHT
-
GAS / CABLE TEIEPHM
OVERHEAD CABLE TELEVISION CTV CTV
O
U)
BURIED CABLE TELEVISION BCTV BCTV
GAS LINE G G
q o0
OVERHEAD TELEPHONE LINE T T T
BURIED TELEPHONE LINE — BTC BTC BTC —
00 0
CABLE RISER PEDESTAL
N
GAS VALVE D4
GAS METER GM
MATCHLINE SHEET C502
o C1
C1 N
N Z
IN 0
wt
d
Li
vi
0
O 0
0
"HOLEY MOLEY " SAYS CALL AT LEAST TWO FULL
WORKING DAYS BEFORE YOU DIG IT'S THE LAW
0
1 -800- 382 -5544
CALL TOLL FREE
1 -800- 428 -5200
FOR CALLS OUTSIDE OF INDIANA
CAUTION
LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
SHOWN ON THIS PLAN ARE BASED UPON ABOVE
GROUNU EVIDENCE (including, but not limited to,
monholrs, inlets, valves, and marks made upon
the ground by others) AND ARE SPECULATIVE IN
NATURE THERE MAY ALSO BE OTHER EXISTING
UNDERGROUND UTILITIES FOR WHICH THERE IS NO
ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE
GROUND EVIDENCE WAS OBSERVED. THE EXACT
LOCATIONS OF SAID EXISTING UNDERGROUND
UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR 10 ANY AND ALL CONSTRUCTION.
1.1
I
o
6
_
0
o
Ln
w Li
� w
w
z_
U CD
t w
z
c� O
Qf w Q z Q
z w z >
r�
0
Z<
UJ W
� U d N d
ozz<
I<<w
-
QUJJJ1- CD
00
rn
r
O `t
L
N �
00 N
0Qi a)
ZQ M a
�o'--Q
= Z Q Q
Q LL.
cl� (n U
0 —
CN
I
r Q w
00
Z
m
c
7,`
W
06
- U
U
v.
Q
V
CD
CD
~
o�
UJ
C
J a-
� °-
a 0
-
�
I--
O
U)
p
q o0
00 0
N
q
ERTIFIED BY:
A.
o PE iro C1 ^S =
Drawn By:
BRIAN STANOCH, EI
Checked By:
CHRIS WISEMAN, PE
Quality Assurance:
TOM SCHELLENBERGER
Scale:
0 Scale 1' = 50'
Sheet
C501
Date
02-08-06
Project Number
050373 -20000
I