Loading...
HomeMy WebLinkAbout06010009.129�y Li 1 0 33 N D l 94S $ J / 32 /15 STORM �- O I 30 d 29 I I 1 15' STORM 28 M \ W w C:) o I 27 1 a 151 STORM 25 I 944 °I �i 0 0 N 20' S.S.,D. & U.E. `.._:. m m m m WINS O VIEW D VE _ t2' �° 15' STOR .. I 2- ST 20' S.S.,D.74 U.E. os � ' S.S „D.- -&'U.t 23 904 22 21 r 20 18' ORM I -oil U W I- < 3 tai d vi vi O �4 � 18 ORM 17 STORM 90.E 943 t5' STORM 30' D. & .E_ 16 20' S.S.46 & U.E. a CN Vi 10 N u 12 4.i 6 90� 13 vi rri N oti a IlM I -y 0 vi N I O E O Li W °- rn (n Q!� o Q N ORM Q O '—J goti V z w Ad I I � I I ,S 30 STORM, N / / / — — BLOCK C 0 O 90 3 9pz O 901 IJ1 5' STORM hfATCHLINE SHEET C501 hfATCHLINE SHEET C502 15* STORM O DETENTION BLOCK B 9 I NORMAL POOL P0897.00 100 YEAR - 900.44 DETENTION POND I 1 I NORMAL POOL - 897.00 I I 1 100 YEAR - 900.44 1 k • II TC= 901.59' I 1 TC= 901.88' - - - - W 1 STO TC =9 i TORM - - -_ _ -TC- 899.88' -- _ I /� TC= 899.47' — — 2 15 DRAINAGE EASEMENT PER APPROXIMfi(E LOCA7!,,,N OF EXISHNG APPR IMATE LOCATION 0�° EXISTING INSTR. No. 2003 - 020240 T ! - r v•�t .i>. T -..� !' 'r; TFR +.d,�!p lCj i � wO�A • 1 a -Tyt1 - - -1r -yU - -W - -t' - - + 1 r - - a, - - - - -- bV ld ' - -- - - •n' -�`�' - -- ” - -_- t- - -- - 902 _- v 902 - _ -BT� —BTC G1Tn. 7 -- - -- - B T C-.{ BTC- - - - =rte — AT . — —� T — — �T —3z -�T — 'II- �+►1F,`� I. T = �E %j3 I - -- — — (I � TC= 901.34' APPROXIMATE LOCATION OF EXISTING SANITARY SEWER MANHOLE N 0: 1200510503731200001cad1Engr1DP— Febl— filing1C501.dwg, 219 /2006 6:11:33 PM, bstanoch, 11 UTM PLM LEWO PROPOSED CON87RUM ON SANTARY SEWER SANITARY CLEANOUT co SANITARY LATERAL SANITARY MANHOLE SANITARY LINE S SANITARY STRUCTURE NUMBER 501 ITC 1715.501 SANITARY CASTING ELEVATION EASEMENT LINE SANITARY SEWER EASEMENT S.S.I. SANITARY SEWER, DRAINAGE S.S.,D.& U.E. & UTILITY EASEMENT :D � Z_ U C7 STORM SEWER CURB WITH SUBSURFACE DRAIN (SSD) F �w zwa Hzwz >F- CURB INLETS STORM SEWER INLETS Q Q Q W Q U J J J F- r.� STORM MANHOLE 00 END SECTION O STORM SEWER STRUCTURE NUMBER 500 Q IE: 715.50 STORM SEWER INVERT ELEVATION 0 TOP OF CASTING ELEVATION TC: 715.50 SWALE WITH SUBSURFACE DRAIN (SSD) =WALE W /,a ®0.70 - WATER WATER LINE W W WATER VALVE H PROPOSED FIRE HYDRANT A► WATER METER PROPOSED BLOW OFF ASSEMBLY ■ 8.0. PROPOSED REDUCER b PROPOSED 'TEE' I=i PROPOSED 45' ELBOW PROPOSED 90' ELBOW rq PROPOSED 22' ELBOW PROPOSED 11' ELBOW O ELECTRIC OVERHEAD ELECTRIC E E BURIED ELECTRIC BEC BEC ELECTRIC MANHOLE OE POWER POLE GUY WIRE L TRANSFORMER ELECTRIC PEDESTAL !� GUY POLE w ELECTRIC METER Q STREET LIGHT � Q STREET LIGHT AREA LIGHT -�- FLOOD LIGHT _I Y OAS / CABLE / TELEPHOW OVERHEAD CABLE TELEVISION CTV CTV BURIED CABLE TELEVISION BCTV BCTV GAS LINE G G OVERHEAD TELEPHONE LINE T T T BURIED TELEPHONE LINE — BTC BTC BTC — CABLE RISER PEDESTAL GAS VALVE D4 GAS METER GM 'HOLEY MOLEY " SAYS CALL AT LEAST TWO FULL WORKING DAYS BEFORE YOU DIG IT'S THE LAW lk 1 -800- 382 -5544 CALL TOLL FREE 1 -800- 428 -5200 FOR CALLS OUTSIDE OF INDIANA CAUTION_ LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND IVIDENCE (including, but not limited to, manholes, inlets, valves, and marks made upon the ground by others) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND LVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. �Y 0 0 co w of w W :D � Z_ U C7 UJ_ w _ �z (� O w W , Z F �w zwa Hzwz >F- U U Q Q� fy Of O = J O c c Z U z z z Q Cf) Q Q Q W Q U J J J F- r.� 0 0 0 0 0 0 00 O Ln I N -. 0 (D 00 N Q O Q a) Q- 0 =zQ Q Q cr V U O _ N O r1- Q (D :E Q N I � W E 00 z C q- W (V O CV �12 Z c Q 0111- w NC1 -0 � Q �- O _I Y N o q -0 � cc - U 00 a a ERTIFIED tz, a z/G ,v Drawn By: BRIAN STANOCH, EI Checked By: CHRIS WISEMAN, PE Quality Assurance: TOM SCHELLENBERGER Scale: 0 Scale: 1' = 50' Sheet C502 Date 02-08 -06 Project Number 050373 -20000