HomeMy WebLinkAbout06010009.129�y
Li
1
0
33 N
D
l 94S $
J
/ 32
/15 STORM �-
O I
30
d
29
I
I
1
15' STORM 28
M
\ W
w
C:)
o
I 27
1
a
151 STORM
25
I 944
°I
�i
0
0
N
20' S.S.,D. & U.E. `.._:.
m m m m
WINS O VIEW D VE _ t2' �°
15' STOR
.. I
2-
ST 20' S.S.,D.74 U.E. os � ' S.S „D.- -&'U.t
23 904
22
21
r
20
18' ORM
I
-oil
U
W
I-
< 3
tai
d
vi
vi
O
�4
� 18
ORM
17
STORM
90.E
943
t5' STORM
30' D. & .E_
16
20' S.S.46 & U.E.
a
CN
Vi
10 N
u
12
4.i
6
90� 13 vi
rri
N
oti
a
IlM I -y
0
vi
N
I O
E O
Li
W °-
rn
(n
Q!� o
Q N
ORM
Q O
'—J goti
V
z w
Ad
I I �
I I
,S
30 STORM,
N / /
/
— — BLOCK C
0
O 90
3
9pz
O
901 IJ1 5'
STORM
hfATCHLINE SHEET C501
hfATCHLINE SHEET C502
15* STORM
O
DETENTION
BLOCK B 9 I NORMAL POOL P0897.00
100 YEAR - 900.44
DETENTION POND I 1 I
NORMAL POOL - 897.00 I I 1
100 YEAR - 900.44 1 k
• II
TC= 901.59' I 1
TC= 901.88' - - - - W 1 STO TC =9 i TORM - - -_ _ -TC- 899.88' -- _ I /� TC= 899.47'
— — 2 15 DRAINAGE EASEMENT PER APPROXIMfi(E LOCA7!,,,N OF EXISHNG
APPR IMATE LOCATION 0�° EXISTING INSTR. No. 2003 - 020240
T ! - r v•�t .i>. T -..� !' 'r; TFR +.d,�!p lCj i � wO�A • 1
a -Tyt1 - - -1r -yU - -W - -t' - - + 1 r - - a, - - - - -- bV ld ' - -- - - •n' -�`�' - -- ” - -_- t- - --
-
902 _-
v
902 -
_ -BT� —BTC G1Tn. 7 -- - -- - B T C-.{ BTC- -
- - =rte — AT . — —� T — — �T —3z -�T — 'II- �+►1F,`� I. T = �E %j3 I - -- — —
(I �
TC= 901.34'
APPROXIMATE LOCATION OF EXISTING
SANITARY SEWER MANHOLE
N
0: 1200510503731200001cad1Engr1DP— Febl— filing1C501.dwg, 219 /2006 6:11:33 PM, bstanoch,
11
UTM PLM LEWO
PROPOSED CON87RUM ON
SANTARY SEWER
SANITARY CLEANOUT
co
SANITARY LATERAL
SANITARY MANHOLE
SANITARY LINE
S
SANITARY STRUCTURE NUMBER
501
ITC 1715.501
SANITARY CASTING ELEVATION
EASEMENT LINE
SANITARY SEWER EASEMENT
S.S.I.
SANITARY SEWER, DRAINAGE
S.S.,D.& U.E.
& UTILITY EASEMENT
:D
� Z_
U C7
STORM SEWER
CURB WITH SUBSURFACE DRAIN (SSD)
F
�w zwa
Hzwz >F-
CURB INLETS
STORM SEWER INLETS
Q Q Q W
Q U J J J F- r.�
STORM MANHOLE
00
END SECTION
O
STORM SEWER STRUCTURE NUMBER
500
Q
IE: 715.50
STORM SEWER INVERT ELEVATION
0
TOP OF CASTING ELEVATION
TC: 715.50
SWALE WITH SUBSURFACE DRAIN (SSD)
=WALE W /,a ®0.70 -
WATER
WATER LINE
W W
WATER VALVE
H
PROPOSED FIRE HYDRANT
A►
WATER METER
PROPOSED BLOW OFF ASSEMBLY
■ 8.0.
PROPOSED REDUCER
b
PROPOSED 'TEE'
I=i
PROPOSED 45' ELBOW
PROPOSED 90' ELBOW
rq
PROPOSED 22' ELBOW
PROPOSED 11' ELBOW
O
ELECTRIC
OVERHEAD ELECTRIC
E E
BURIED ELECTRIC
BEC BEC
ELECTRIC MANHOLE
OE
POWER POLE
GUY WIRE
L
TRANSFORMER
ELECTRIC PEDESTAL
!�
GUY POLE
w
ELECTRIC METER
Q
STREET LIGHT
� Q
STREET LIGHT
AREA LIGHT
-�-
FLOOD LIGHT
_I Y
OAS / CABLE / TELEPHOW
OVERHEAD CABLE TELEVISION
CTV CTV
BURIED CABLE TELEVISION
BCTV BCTV
GAS LINE
G G
OVERHEAD TELEPHONE LINE
T T T
BURIED TELEPHONE LINE
— BTC BTC BTC —
CABLE RISER PEDESTAL
GAS VALVE
D4
GAS METER
GM
'HOLEY MOLEY " SAYS CALL AT LEAST TWO FULL
WORKING DAYS BEFORE YOU DIG IT'S THE LAW
lk
1 -800- 382 -5544
CALL TOLL FREE
1 -800- 428 -5200
FOR CALLS OUTSIDE OF INDIANA
CAUTION_
LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
SHOWN ON THIS PLAN ARE BASED UPON ABOVE
GROUND IVIDENCE (including, but not limited to,
manholes, inlets, valves, and marks made upon
the ground by others) AND ARE SPECULATIVE IN
NATURE. THERE MAY ALSO BE OTHER EXISTING
UNDERGROUND UTILITIES FOR WHICH THERE IS NO
ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE
GROUND LVIDENCE WAS OBSERVED. THE EXACT
LOCATIONS OF SAID EXISTING UNDERGROUND
UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR TO ANY AND ALL CONSTRUCTION.
�Y
0
0
co
w of
w
W
:D
� Z_
U C7
UJ_ w
_ �z
(� O
w W , Z
F
�w zwa
Hzwz >F-
U U Q Q� fy Of
O
= J O c c Z
U z z z Q Cf)
Q Q Q W
Q U J J J F- r.�
0 0 0 0 0 0
00
O
Ln I
N -.
0 (D 00 N
Q
O Q a)
Q-
0
=zQ Q
Q
cr V U
O _
N O
r1- Q (D :E
Q N I
� W
E 00
z
C
q- W
(V
O
CV
�12
Z c
Q 0111-
w
NC1 -0
� Q
�-
O
_I Y
N
o
q -0
�
cc
-
U
00 a
a
ERTIFIED tz,
a z/G ,v
Drawn By:
BRIAN STANOCH, EI
Checked By:
CHRIS WISEMAN, PE
Quality Assurance:
TOM SCHELLENBERGER
Scale:
0 Scale: 1' = 50'
Sheet
C502
Date
02-08 -06
Project Number
050373 -20000