HomeMy WebLinkAbout06060001.6D 4 9 _J U �0 00 U a 41,1 0. C_ C�l 00 00 4T H rNAS t-4 t_: (=5 0 x U QA[6j 00 064 Uo"J LEGEND U 0. RIGHT-OF-WAY LINE STORM SEWER LINE lot, 9 IV V 00 00 SWALE SANITARY SEWER SANITARY SEWER MLINE ANHOLE FLOW DIRECTION Z 14 VaV EXIST. CONTOURS gi -n 91 Ua y STORM BEEHIVE INLET STORM INLET T.C. =TOP OF CASTING c) 9 'Wd� LJ C, INV. = INVERT RCP = REINFORCED CONCRETE PIPE PVC = POLYVINYLCHLORIDE SANITARY SEWER PIPE W4 > (C RC l-I LAR, D = 46° 3 �'41 M.H MANHOLE STR = STRUCTURE ] &U E. = DRAINAGE AND UTILITY EASEMENT R.D.E. = REGULATED DRAIN EASEMENT 00 D a -1"17" B.S.L. = BUILDING SETBACK LINE C14 Li N 6 6'4 W T - 64.59 \x L� '! V Q, n�,,(7 mA -3 Av V.W_ = VARIABLE WIDTH PROP = PROPOSED ME MATCH EXISTING W ;* -qi R = 1 \.00 V0 �J TYP = TYPICAL Z L - 121.98 1 18.65 0 "S Jj s. C,\ Cc, SUBSURFACE DRAIN AND SUMP LINE WATER LINE 2 ;:5 CIO PI 1 46'35'41 "R _�8.00 CC CONCRETE END SECTION FLOOD ROUTE U 4 C Sto 14 PT Sta 2+59-98 'V6Z" PROPOSED GRADE Z "Vop"01J, x STM STR #700 =PROP. STORM STURCTURE NO. A 0* SAN STR #900 = PROP. SANITARY STURCTURE NO. I z W RC J LAR D 46 °46'17 -7 rr 61 _4 = EXIST. TREELINE In OR > = 38'1 1'50" 1- - - = PROPOSED FIRE HYDRANT T = PROPOSED WATER LINE VALVE tn 1­4 D = I,,J 66' 4 3 5" j. T 64.87 P 0 = PROPOSED PAD GRADE O L 1 22.4�, // ���e C) 3 M.F.P.G. = MINIMUM FLOOD PROTECTION GRADE OF PADS. MINIMUM GRADE FOR ANY C, = 1 9.08 P; �� % _ - _ _ N" STRUCTURE OPENING (DOOR, WINDOW WELL, OUTSIDE BASEMENT STAIR - Sta 4.58 46'46'1 Q" 4 ACCESS, ETC.) C o - MINIMUM COVI R FOR PIPE CROSSINGS OF CITY PC :�')ta - 4+49,72 PT C_,tC - C2 // 0. \19 ono > - STREETS For installation of Storm Mains, Water Mains, Scnitcry Main ;, Water Service Laterals, Scn�tcry 2- Sewer Laterck; under City streets, regardless of the *ur'sd*ct 2- 03 _x\ 069-1, (,n of the utility, the minimum cover from the top of the installed pavement to the 10 No, V L -r- top of the installed pipe shall be the pavement 16-6 sect*on thickness (,-,Il bituminous and aggregate the 1' C! 06 material above subgrade) plus -0". If the standard PrC,ti(,e of the utility that has !\ 0- 01 od& -- 6Z 2 _ 4 , MA jurisdiction urisd'ct'on over the installation has a more stringent cover requirement, the more stringent _ Z requirement .hall govern. -No O� 0�, J V 5-O E S 4.0 R C HO RIZONTAL SC ,4LE r=50, 0. lz'l - 0 �'89 CITY OF CARMEL STANDARD BACKFILL NOTES: STORM SEWERS 1 3.0 T Bedding, Haunchinq Initial Backfill -4 C d) CD CD Bedding, haunching and initial backfill for all RCP installations shall .5 2.0 C L 1 be B-Borrow for �Jructjre Backfill meeting the material E .0 A requirements of tirw INDO-1. Bedding shall be placed in the trench 0.0 L bottom such that after the pipe is installed to grade and line, there remains a 4-inch minimum depth of material below the pipe TREET barrel and a mininium of 3-inches below the bell. For pipe sizes 66-inches and lar,ler, the minimum depth of material below the pipe barrel shall lb,� 5-inches. Bedding, hounching and initial backfill H I'/// v shall be compacted in 6-inch maximum lifts to not less than 95% ___ - Z, NO. Standard Proctor 11snsity for the entire depth of the material placed. The backfill shall be brought up evenly on both sides of the for full If-rigtIl- • 8827 895 895 pipe the of the pipe. Hounching shall extend to the springline of the pipe The limit of initial backfill shall be 6-inches -0 STATE OF �T4 above the sprirglhn,�. Minimum trench width shall be the outside diameter of the pipe plus 18-inches. 0 + `16 1`0 Final Backfill /ONAL 00 ur) C� rr) Ln C11J Ln M Final backfill for all RCP installations under and within 5-feet of pavement shall be H-Borrow for Structure Backfill meeting the 890 C? co Lr. (7) (::) r- i 14 n 1 TO M )0 CD M cl-� C-4 + 890 material requirements of the INDOT and shall be compacted in 6-inch maximum lil to not less than 95% Standard Proctor 4 CO ;I- I I r-- 00 :0 D 00 L [1- F r�_ 00 Density for the enilre depth of the material placed. The backfill for the top 6-inches :)f the excavation below the start of the ALLAN H. �VEIHE P.E 8827 C/) 11 L __J 00 U aggregate subbase of the pavement shall be No. 53 Stone meeting 9 the material LLJ < _J ILLJ LIJ _J ILLJ 11 _J LLJ requirements of the INDOT and shall be compacted to not less than 95% Standard Proctor Density. C/-) n > 1-- Cn _J VPI S A 4+60.00 (0 U a_ <C __J LIJ a_ VPI STA 7+35.00 885 Final Backfill for all PCP installations greater than 5-feet of pavement shall be clean fill material free of rocks larger than 885 a- a- 'gao'go () I > __J 6-inches in diameter, frozen lumps of soil, wood or other 7777- PROPOSED CL CURVE LEN 100.00 > Q_ CL :> _VPI EL d�U.bU CURVE LEN 100-00 extraneous material, compacted in 12-inch maximum lifts to not less than 90% Standard Proctor Density for the entire depth of the GRADE VPI S = 9+60.00 co excavation. CITY OF CARMEL STANDARD BACKFILL NOTES: VPI E = 877.30 + 880 2 CURVE LEN 100.00 880 WATER AND SEWER UNDER CITY STREETS Bedding, Hcunching, Initial Backfill CD 71 0 (D EXISTING < Bedding, hcunclhing, initial backfill materials, placement and compaction for wafer mains, water service laterals, sanitary mains CD + 1::� GRADE- VPI STA 3+50.25 VPI STA 6+08-24 PROPOSED and sanitary service laterals shell be in accordance with the standard practice )f the utility that has jurisdiction over the 1 1 CD 00 00 VPI EL 879.15 VPI EL 878.50 GRAD 875 installation. 875 CURVE LEN 100.00 CURVE LIEN� = 100.00 Final Backfill _J + .4- C� Ln CD co CD Ln ID CD + CC) Lf) C? CD 00 \\�l 2" RC INV.=874.62 0 0 Ln 00 + C) Ln + CD CD Lcj 00 + ZD )12 Final backfill 'or water mains, water service laterals, sanitary mains and sanitary service laterals under and within 5-feet of pavement shall be B-Borrow for Structure Backfill meeting the material requirements of thr� NDOJ and shall be compacted in 6-inch (J-) O 11 < 00 11 00 11 11 00 11 r- 00 00 00 11 00 + O 00 RCP 870 maximum lifts to not less than 95% Standard Proctor Density for the entire depth of the material placed. The backfill for the -top 870 _J _J 1.1 _J M r- 1 00 INV. -873.1 ic� 00 6-inches of the e•covation below the start of the aggregate the subbase of pavement shall be No. 53 Stone meeting the material requirements of the INDOT and shall be compacted to not less than 95% Standard Proctor Density. If the standard of 2� 12" PCID td [I- a- a- a- 0- U U L'i a- a- F + C-� r INV.=870.70 > > > > > iL a- > > - __J Y) LLJ 00 practice the utility that has jurisdiction over the installation has a more < 11 stringent final backfill requirement, the more stringent requirement shall govern. > > �n _J LLi 865 865 COVER FOR PIPE CROSSINGS OF CITY STREETS C:6 A > MINIMUM C/D EXISTING For installation of -torm Mains, Water Mains, Sanitary Mains, Water Service Laterals, Sanitary Sewer GRADE Laterals under City streets, regardless of the jurisdiction of the utility, the minimum cover from 860 the top of the installed pavement to the top of the installed pipe shall be the pavement section practice of the utility that has th,, installation has 860 jurisdiction over a more stringent cover requirement, the more stringent requirement shelf govern. C) C) C__ C, I JD -7) CC) 0 _ A, 855 1 Cv Ln 00 co cc cc 00 00 cc 00 co 03 00 cc 00 00 00 cc 00 cc -C �C (711 CID cc 0- �1_ aD CT) DD :u _0 cc D F-- 0- o-) cc �c 855 CG w d 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 0+00 SHEET N0. C201 1 PROJECT NO W06-0031 4 9 _J U