HomeMy WebLinkAbout08050046.2GENERAL NOTES A. ALL WORK ON PROJECT MUST COMPLY WITH ALL APPLICABLE CURRENT LOCAL, STATE AND NATIONAL CODES B. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, DUST PARTITIONS, ETC. AS REQUIRED BY LAW AND AS OTHERWISE REQUIRED C. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, PALLETS, PACKAGING, UNUSED MATERIALS, TRASH MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THHE JOBSITE D. VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. NOTIFY DESIGN POINT, INC. IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDING WITH WORK. E. REVIEW ALL DRAWINGS (PLUMBING, ARCHITECTURAL, ELECTRICAL, HVAC) CONCERNING SLEEVES, OUTLETS, BOXES, ANCHOR VENTS, OPENINGS, ETC. THAT MAY BE REQUIRED. EACH RESPECTIVE TRADE IS RESPONSIBLE FOR PROVIDING AND INSTALLING THESE ITEMS. F. NIC = "NOT IN CONTRACT" G.C. SHALL COORDINATE AND VERIFY AS TO BLOCKING, HOOK -UP, AND OTHER REQUIREMENTS WITH TENANT. G. CONTRACTOR TO PROVIDE BLOCKING IN WALL AT ALL WALL MOUNTED EQUIPMENT GENERAL CEILING PLAN NOTES A. REFER TO ELECTRICAL DRAWINGS FOR LIGHTING SPECIFICATIONS AND SWITCHING INFORMATION. B. REFER TO ROOM FINISH SCHEDULE FOR CEILING HEIGHT. C. INSTALLATION OF ACOUSTICAL CEILING PAD GENERAL: 1. INSTALL IN LEVEL PLANE IN STRAIGHT LINE COURSE 2. PLACE MATERIALS TO BEAR ALL AROUND ON SUSPENSION MEMBERS. 3. CUT UNITS NEATLY TO FIT GRILLES, DIFFUSERS, AND ALL PENETRATIONS. 4. INSTALL BOARDS FROM A THREE CARTON MIX TO OBTAIN A UNIFORM DISTRIBUTION OF SURFACE VARIATIONS. PLAN NOTE/ TOILET 1. GRAB BAR MANUF: MODEL NO.: 2. TOILET PAPER HOLDER MANUF: MODEL NO.: 3. SURFACE MOUNTED MIRROR MANUF: MODEL NO.: 4. NOT USED 5. NOT USED 6. PAPER TOWEL DISPENSER MANUF: MODEL NO.: HVAC NOTES 1. HEATING AND AIR CONDITIONING UNIT(S) COMPLETE WITH SUPPLY DUCTWORK, RETURN AIR DUCTWORK, CEILING DIFFUSERS, ELECTRICAL CONNECTIONS AND ALL WIRING AND CONTROLS REQUIRED BY A COMPLETE OPERATING UNIT(S). AIR CONDITIONING DESIGN SHALL BE BASED ON ONE (1) TON PER EVERY 400 FEET OF GROSS LEASED AREA. CEILING PLAN SYMBOLS 2 X 4 NON- DIRECTIONAL FISSURED LAY -IN CEILING TILE WITH STANDARD GRID THROUGHOUT SPACE (10' -0" A.F.F.) 2 X 4 RECESSESED FLOURESCENT LIGHT FIXTURE WITH ACRYLIC PRISMATIC LENS 1 FIXTURE PER 100 SO. FT. EXHAUST FAN W /LIGHT N.L. NIGHT LIGHT EMERGENCY WALL LIGHT tfr SINGLE POLE SWITCH PLUMBING NOTES 1. ONE (1) 6 GALLON WATER HEATER PROVIDED AT RESTROOM LOCATION. RUN OVERFLOW PIPING DOWN THRU WALL AND ELBOW APROX. 2" ABOVE BATHROOM FLOOR. 3" VENT TO MAIN BLDG. VENT C.O. W C. 2" WASTE �N 6\ hc' WALLS: a — WALL TYPE SUFFIX SYMBOLS: EXISTING WALL NEW WALL, EXTEND GYPSUM BOARD 4" ABOVE FINISH CEILING. %7 EXISTING DOOR N OPENINGONUMBER N DESIGNATION. REFER TO THE DOOR SCHEDULE. WALL TYPES: ONE LAYER 5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUDS AT 16" O.C. EXTEND TO DECK ABOVE. WALLS TO BE TAPED SANDED AND AND ONE PRIMER COAT OF PAINT APPLIED (PROVIDE FULL HEIGHT INSULATION) ONE LAYER 5/8" GYPSUM BOARD EACH SIDE OF 6" METAL STUDS AT 16" O.C. EXTEND TO METAL DECK ABOVE WALLS TO BE TAPED SANDED AND AND ONE PRIMER COAT OF PAINT APPLIED (PROVIDE FULL HEIGHT INSULATION) ELECTRICAL NOTES 1. ONE (1) 200 AMP 120/208 VOLT 3 PHASE SERVICE WILL BE PROVIDED 2. WALL RECEPTACLES WILL BE PROVIDED PER DRAWING 3. PHONE BD. PROVIDED AS NOTED ON DRAWING 2' X 4' X 3/4" PLYWOOD ELECTRICAL LEGEND 110 VOLT 4 —PLEX WALL RECEPTACLE 110 VOLT DUPLEX WALL RECEPTACLE Gn DUPLEX RECEPT. W/ GROUND FAULT INTERRUPTER AFF ABOVE FINISH FLOOR 3 MECHANICAL PLAN SCALE: 1 /8 " =1' -0" DOOR/ HARDWARE SCHEDULE DOOR NO. DIMENSIONS TYPE CONST. MAT'L. FINISH HDWR. SET DOOR ELEV REMARKS WIDTH HT. THK. 202 3' -0" 7' -0" 1 3/4" FLUSH SOLID CORE BIRCH UN— FINISHED 1 — BIRCH VENEER DOOR WILL BE PAINT GRADE WELDED METAL FRAME (PRIMED) ILI-MEN INNEWE" WITH 2 NUTS LOCKING THREADED ROD THRU UNISTRUT UNISTRUT ON TOP OF STRUCTURE MEMBER EXISTING STRUCTURE 5—CW HW-- -� BALL TYPE THERMOMETER SHUT —OFF VALVE—, UNION �� 1/2" THREADED ROD (NP OF 4) T T ASME T&P RELIEF VALVE DOMESTIC WATER HEATER WATER HEATER PLATFORM TO BE-' 3/4" PLTWOOD BOLTED THRU UNISTRUT TYP. TOILET ROOM RISER DIAGRAM TYP. HOT WATER HEATER INSTALLATION 140 SME 140 WAIS FULL SIZE DRAIN VALVE TO FLOOR DRAIN OR LAVATORY X_ SUSPEND WATER HEATER PLATFORM FROM STRUCTURE. NUTS LOCKING THREADED ROD THRU PLATFORM UNISTRUT (TYPICAL OF 4) DOOR SCHEDULE NOTES 1. ALL HARDWARE TO HAVE FINISH US26D UNLESS NOTED OTHERWISE. 2. LOCKSETS A. BEST/ FALCON CYLINDERS AND KEYS OR EQUAL A. BEST/ FALCON 3. REAR DOOR: ONE (1) 3' X 7' METAL SOLID CORE DOOR AND WELDED METAL FRAME W/ EXISTING BUILDING STANDARD HARDWARE 4. STOREFRONT: ONE (1) 3' X 7' ALUM. FRAME WITH TEMPERED GLASS. DOOR COMES COMPLETE WITH BUILDING STANDARD STANDARD HARDWARE HARDWARE SETS: HARDWARE SET #1 BUTT HINGES PRIVACY OVERHEAD CLOSURE WALL STOP U U U (EE ILING PLAN 2 LE: 1/8 " =1'-0" kS LO R CALE: 1/8 " =1' -0" 0 c m 0 'tJ CD r m fi E U z z o, ►: o � 0 m (/) m a ° o W m « m �VE...F...SM' %, �OF.VLSTFRFq��' 19600042 STATE [IF I IANP:' 9 V1 0 C) ® Q Z Q 00 MZ r Ow Ln N _J c- w N �- Z r- 0 r- t) N 1AATE: 20 MARCH 0 SC43LE: AS NOTED DPtANVN; GFS REVL%0NS= All ideas, designs, and plans indicated or represented by these drawings are owned by, and the property of Design Point, Inc. Contractors shall verify and be responsible for oil dimensions on the job site. All rights reserved, except for uses expressly permitted in writing; information shown or included on these drawings are solely the property of Design Point, Inc. DRAWING NAME- FLOOR/ CEILING/ MECH PLANS PF,0JFCT= SHEET )v ILI-MEN INNEWE" INIII�Er wl"I��'�1 111111-.0gal �ql III, falli n������ U U U (EE ILING PLAN 2 LE: 1/8 " =1'-0" kS LO R CALE: 1/8 " =1' -0" 0 c m 0 'tJ CD r m fi E U z z o, ►: o � 0 m (/) m a ° o W m « m �VE...F...SM' %, �OF.VLSTFRFq��' 19600042 STATE [IF I IANP:' 9 V1 0 C) ® Q Z Q 00 MZ r Ow Ln N _J c- w N �- Z r- 0 r- t) N 1AATE: 20 MARCH 0 SC43LE: AS NOTED DPtANVN; GFS REVL%0NS= All ideas, designs, and plans indicated or represented by these drawings are owned by, and the property of Design Point, Inc. Contractors shall verify and be responsible for oil dimensions on the job site. All rights reserved, except for uses expressly permitted in writing; information shown or included on these drawings are solely the property of Design Point, Inc. DRAWING NAME- FLOOR/ CEILING/ MECH PLANS PF,0JFCT= SHEET )v