HomeMy WebLinkAbout05060191 - Site Plan'lhis Plot Plan Prepared For:. R.H. of Indla"'~' The Schneider Co~o~at~n Za~tnem't,~ 8901 Otis A~e~ue Sm-raying D End Sect~n (storm) Note: Sanitary Sewer Top of Casting Information Upstream Manhole, T¢= glfi.50 Downstream Manhole, TC=915.80 per plan. Sod Calculations: Drive -- 1,203~+ Public Walk =453 SF+ Private Walk =215 SF+ Hydroseeding =5,729 SF± Sod =64-0 SY± , fram Rear of residence. Lot # 189 , containing 14,514 S.F.+, in Qa~oume SecUon t 3 H~tm ~nty, Oey T~ Prepered 0~te:06/08/05: B~ JKI ~LLALTA ~mun~ty Res~ricUon~: Side Yard = 5' Reor Yerd= 20' Aggregate = lO' (8.H.) ~.H. of Indiana Finished Floor Devation Informtlon Pod ~ade = g17.8 per plan Pod ~rode ~ o.T = ~arage ~ (g18.5) ~orage ~ + LS' = Resldentiol ~ (g20. O) Residential F~ - 9.0' = Basement ~ (gH.O) No~e: ~e garoge tint,ed fl~ ~e~ti~ Is 2.~' obo~ the cu~ at ~e drl~. per plon. Note: This drawing is based on construction plans or record drawings, and is not based upon a field survey. Re Sd~neider Corporation does not warrant the accuracy or sufficiency of this information, Contractors should verify existing conditions prior to on)' construction, Any discrepancy found on this drawing should be reported to The Schneider Corpcrotion imrnedintd~ foiling to do so results in the contrcctcre assumption of oil liobaity. Note: The basement elevation, depicted hereon, hon been determined and based upon the pad grades and/or contours takes fi.om the construction plans for this subdivision. Unless s~ated, no information about fluctuating water tables, sei~ conditions, or soil t~pes has been pro~ded or stated on said plans. It is reccmmended that the basement finished floor elevations be at least two feet (2') abo~ the non'hal pool devetion of any ~djoinbg bodies of water, unless a study of focb reveals otherwise, If during the excavation process any ground water is withe~sed, 11~e Schneider Coq)oration should be notified immediate~y. The basement elevation should be raised two feet (2') cho~ the Ground water, and additional construction techniques should be incorporated to alleviate future problems. VB05.0035040 Lot # 189 D Sidewalk to be placed 1' fi.om property line, 11' fi.om back of curb, per plan. Assumed Nodh Scale: 1' = 30' Note: Budder to ensure positive Deta~ of G'ound/Stcem Water flow pattern for indMdual lots. \ drainage away fi.om structure(s). · t.,, '"" NOT: ~1'C~916'.50 8MILDER S C^U~]ONED, CONS~UC~ON OF'/)RIVE Note: Sump pump(s) to be = /~ ~.~"~ ' PER P~N PERMITIED ONLY A,qER OBTAINING APPROVAL placed by budder as needed. TC 915,80 Il /t ~ ~ F~OM l~E CONTROLUNG MUNIQPAU~(. T ' .... I % - ~. ~~ -'r PER ~ Note: The contractor is to minthin a minimum distance of ten feet (10') betwam the sanitary sewer and water line laterals. Note: Per Cermd zoning ordinance 26,1.1: The residential district limits height to twenty-five feet however a dwelling may be increased in height to thirty-fi~ feet (35') provided the side and rear yards are increased an additional ane foot (1') for each one foot (1') the structure exceeds the first twenty-five feet (25') in heighL FLOODHAZARD STATEMENT CERtiFICATiON No. sosos %" * ............ ~ ~//lllfi~lll[B~~ Flood Hazard Statement: lhe accuracy of any floo~ hazard data insurance rate map. ALL of the within described land DOES NOT lie within that special flood hazard zone AE as said land plats by scale on flood insurance rate map ~180081 0205 F for the City of Carmel, Indiana dated Februa~ 19, 2003. I~A~RE: OA~: ~E ~EPRE~ C~fl~A~ ~ RE~IPT ~ PLOT P~ gY ~ST~ER. 15' DU&S~ 25' BL 65.3' 79.43' 10' DUt~'E