HomeMy WebLinkAbout05060191 - Site Plan'lhis Plot Plan Prepared For:. R.H. of Indla"'~'
The Schneider Co~o~at~n Za~tnem't,~
8901 Otis A~e~ue Sm-raying
D End Sect~n (storm)
Note: Sanitary Sewer
Top of Casting Information
Upstream Manhole, T¢= glfi.50
Downstream Manhole, TC=915.80
per plan.
Sod Calculations:
Drive -- 1,203~+
Public Walk =453 SF+
Private Walk =215 SF+
Hydroseeding =5,729 SF±
Sod =64-0 SY± , fram
Rear of residence.
Lot # 189 , containing 14,514 S.F.+, in
Qa~oume
SecUon t 3
H~tm ~nty, Oey T~
Prepered 0~te:06/08/05: B~ JKI
~LLALTA
~mun~ty Res~ricUon~:
Side Yard = 5'
Reor Yerd= 20'
Aggregate = lO' (8.H.)
~.H. of Indiana
Finished Floor Devation Informtlon
Pod ~ade = g17.8 per plan
Pod ~rode ~ o.T = ~arage ~ (g18.5)
~orage ~ + LS' = Resldentiol ~ (g20. O)
Residential F~ - 9.0' = Basement ~ (gH.O)
No~e: ~e garoge tint,ed fl~ ~e~ti~
Is 2.~' obo~ the cu~ at ~e drl~. per plon.
Note:
This drawing is based on construction plans or record drawings,
and is not based upon a field survey. Re Sd~neider Corporation
does not warrant the accuracy or sufficiency of this information,
Contractors should verify existing conditions prior to on)'
construction, Any discrepancy found on this drawing should be
reported to The Schneider Corpcrotion imrnedintd~ foiling to do
so results in the contrcctcre assumption of oil liobaity.
Note: The basement elevation, depicted hereon, hon been
determined and based upon the pad grades and/or contours takes
fi.om the construction plans for this subdivision. Unless s~ated, no
information about fluctuating water tables, sei~ conditions, or soil
t~pes has been pro~ded or stated on said plans. It is reccmmended
that the basement finished floor elevations be at least two feet (2')
abo~ the non'hal pool devetion of any ~djoinbg bodies of water,
unless a study of focb reveals otherwise, If during the excavation
process any ground water is withe~sed, 11~e Schneider Coq)oration
should be notified immediate~y. The basement elevation should be
raised two feet (2') cho~ the Ground water, and additional
construction techniques should be incorporated to alleviate future
problems.
VB05.0035040
Lot # 189
D Sidewalk to be placed
1' fi.om property line,
11' fi.om back of curb,
per plan.
Assumed Nodh
Scale: 1' = 30' Note: Budder to ensure positive
Deta~ of G'ound/Stcem
Water flow pattern for
indMdual lots.
\
drainage away fi.om structure(s).
· t.,, '"" NOT:
~1'C~916'.50 8MILDER S C^U~]ONED, CONS~UC~ON OF'/)RIVE
Note:
Sump
pump(s)
to
be
= /~ ~.~"~ ' PER P~N PERMITIED ONLY A,qER OBTAINING APPROVAL placed by budder as needed.
TC 915,80 Il /t ~ ~ F~OM l~E CONTROLUNG MUNIQPAU~(.
T ' ....
I % - ~. ~~ -'r PER ~
Note:
The contractor is to minthin a minimum
distance of ten feet (10') betwam the
sanitary sewer and water line laterals.
Note: Per Cermd zoning ordinance 26,1.1: The
residential district limits height to twenty-five feet
however a dwelling may be increased in height to
thirty-fi~ feet (35') provided the side and rear yards
are increased an additional ane foot (1') for each one
foot (1') the structure exceeds the first twenty-five feet
(25') in heighL
FLOODHAZARD STATEMENT
CERtiFICATiON
No.
sosos
%" * ............ ~
~//lllfi~lll[B~~
Flood Hazard Statement: lhe accuracy of any floo~ hazard data
insurance rate map. ALL of the within described land DOES NOT lie
within that special flood hazard zone AE as said land plats by scale on
flood insurance rate map ~180081 0205 F for the City of Carmel,
Indiana dated Februa~ 19, 2003.
I~A~RE: OA~:
~E ~EPRE~ C~fl~A~ ~ RE~IPT ~ PLOT P~ gY ~ST~ER.
15' DU&S~
25' BL
65.3'
79.43' 10' DUt~'E