HomeMy WebLinkAbout08050106.4T= __ ref / a7� (V Q 0 c� 0 00 X// / // / TYP. E ST , ° lsl o / r�� se /� 123,+ r. / /J to 1 i T% / 7// i / / / /' /' � 179 / /� �/ / /�, / / /_ 2 EXIST TYP. / / �' 176 1 � 180 I ® r' /% B 178 r � �— 77 7 T�T7/� / , i 7 / � y � EXIST / 177 j i Jd Ol FIRST FLOOR AREA B REFLECTED CEILING PLAN 61 8 East Market Street I Indianapolis, Indiana 46202 ph 317/264.8162 Fx 317/264.8165 a x i s a r c h. c o m GENERAL RCP NOTES: A. REFER TO SHEET A2.1 FOR TYPICAL WALL TYPES AND ADDITIONAL WALL TO CEILING DESIGN CONDITIONS AND CONSIDERATIONS. B. PROVIDE NIGHT LIGHT CIRCUITS AS REQUIRED. PROVIDE EMERGENCY AND EXIT LIGHTING AS REQUIRED BY CODE. C. THE ARCHITECTURAL CEILING PLANS SHALL GOVERN THE LAYOUT OF ALL CEILING ELEMENTS AND /OR PENETRATIONS. COORDINATE WITH THE ARCHITECT ANY FIELD VERIFIED OR AS -BUILT CONDITIONS THAT DIFFER THAN WHAT IS SHOWN ON THESE PLANS. D. SIZES AND SHAPES OF LIGHTING AND OTHER MISC. ELECTRICAL EQUIPMENT ARE SHOWN FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES WITH ELECT. ENGINEER OR CONTRACTOR. E. UNLESS NOTED OTHERWISE, INSTALL SUSPENDED CEILING GRID WITH EQUAL SIZE PANELS AT EACH SIDE OR ENDS OF ROOMS. NO PANELS SHOULD BE LESS THAN 12 ". F. IF POSSIBLE, ANY CEILING MOUNTED ITEMS SHOULD BE CENTERED IN CEILING PANELS. G. ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR THE REWIRING AND /OR RE- SWITCHING OF ALL LIGHT FIXTURES AND /OR LIGHT SWITCHES AS REQ'D. BY NEW CONSTRUCTION. COORDINATE WITH ARCHITECT ANY ADDITIONAL REQUIRED WORK NOT SHOWN HERE. CEILING TYPES: PES: CEILING CEILING HEIGHT MATERIAL A. NO CEILING IN THIS SPACE B. TIE IN NEW CEILING TO MATCH EXISTING CEILING TO REMAIN. REFLECTED CEILING LEGEND: — 2x4 ACCOUSTICAL CEILING TILE —2x2 ACCOUSTICAL CEILING TILE WALL MOUNTED EMERGENCY BATTERY PACK I—® WALL MOUNTED EXIT SIGN 4' INDUSTRIAL FLUORESCENT -MOUNT AT 12' -0" —GYPSUM BOARD CEILING OR GYPSUM BOARD BULKHEAD Scrape Drawings These drawings indicate the general scope of Ore project in terms of amWectural design concept, The dimenvons of the buiking, the major architectural elements and the Mm of structural, mechonicol and electrical systems. The drawings do not necessarily indicooe or describe all work required for W performance and compWon of the requirements of the contract On the basis of the general scope indicated or described, The trade contractors sholl fumish all items required for the proper execution and complabon of the work. DRAWN by CRH CHECKED by DDW DATE issued 05 06.2008 REVISIONS CEILING PLAN NOTES: 0 Z 1. 4' -0" INDUSTRIAL FLUORESCENT LIGHT FIXTURE. INSTALL AT 12' -0" AFF O SUSPENDED FROM STRUCTURE ABOVE. 2. PATCH AND REPAIR EXISTING CEILING AS REQUIRED IN THIS SPACE. ~ N W u. � 3. INSTALL NEW CEILING IN THIS SPACE. TIE INTO EXISTING CEILING THAT UJ N REMAINS. PROVIDE ADDITIONAL FLUORESCENT LIGHT FIXTURES AS REQUIRED. 4. RELOCATED INDUSTRIAL LIGHT FIXTURE. PROVIDE (1) ADDITIONAL FIXTURE IN > v THIS SPACE TO MATCH EXISTING. LOCATE SWITCHES NEAR MAN -DOOR. O V) z t� Z �%o 0 o uU o0 -� O � �; O � a a� W Q 3 Z Z o _ a 00 O qq Z D m \ \ \ \ \ \ \ \ \\1llUl{II7��� KEYPLAN: °'''off .. „ ' % Q�� erLG 1 S O,, 2 AR- 19 400087 a? STATE OF IR i "� Jnu uuu vv4 /,/, ; l/ /l //I AA , /% AREA A AREA OF WORK FIRST FLOOR AREA B / REFLECTED CEILING AREA B PLAN SCALE AS NOTED L 'ARE A C " A 102 00