Ol FIRST FLOOR AREA B REFLECTED CEILING PLAN
61 8 East Market Street I
Indianapolis, Indiana 46202
ph 317/264.8162 Fx 317/264.8165
a x i s a r c h. c o m
GENERAL RCP NOTES:
A. REFER TO SHEET A2.1 FOR TYPICAL WALL TYPES AND ADDITIONAL WALL TO
CEILING DESIGN CONDITIONS AND CONSIDERATIONS.
B. PROVIDE NIGHT LIGHT CIRCUITS AS REQUIRED. PROVIDE EMERGENCY AND
EXIT LIGHTING AS REQUIRED BY CODE.
C. THE ARCHITECTURAL CEILING PLANS SHALL GOVERN THE LAYOUT OF ALL
CEILING ELEMENTS AND /OR PENETRATIONS. COORDINATE WITH THE
ARCHITECT ANY FIELD VERIFIED OR AS -BUILT CONDITIONS THAT DIFFER THAN
WHAT IS SHOWN ON THESE PLANS.
D. SIZES AND SHAPES OF LIGHTING AND OTHER MISC. ELECTRICAL EQUIPMENT
ARE SHOWN FOR REFERENCE ONLY. COORDINATE ACTUAL SIZES WITH ELECT.
ENGINEER OR CONTRACTOR.
E. UNLESS NOTED OTHERWISE, INSTALL SUSPENDED CEILING GRID WITH
EQUAL SIZE PANELS AT EACH SIDE OR ENDS OF ROOMS. NO PANELS SHOULD
BE LESS THAN 12 ".
F. IF POSSIBLE, ANY CEILING MOUNTED ITEMS SHOULD BE CENTERED IN
CEILING PANELS.
G. ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR THE REWIRING
AND /OR RE- SWITCHING OF ALL LIGHT FIXTURES AND /OR LIGHT SWITCHES AS
REQ'D. BY NEW CONSTRUCTION. COORDINATE WITH ARCHITECT ANY
ADDITIONAL REQUIRED WORK NOT SHOWN HERE.
CEILING TYPES: PES:
CEILING
CEILING HEIGHT MATERIAL
A. NO CEILING IN THIS SPACE
B. TIE IN NEW CEILING TO MATCH EXISTING CEILING TO REMAIN.
REFLECTED CEILING LEGEND:
— 2x4 ACCOUSTICAL CEILING TILE
—2x2 ACCOUSTICAL CEILING TILE
WALL MOUNTED EMERGENCY BATTERY PACK
I—® WALL MOUNTED EXIT SIGN
4' INDUSTRIAL FLUORESCENT -MOUNT AT 12' -0"
—GYPSUM BOARD CEILING
OR GYPSUM BOARD BULKHEAD
Scrape Drawings
These drawings indicate the general scope of
Ore project in terms of amWectural design
concept, The dimenvons of the buiking,
the major architectural elements and the
Mm of structural, mechonicol and electrical
systems. The drawings do not necessarily
indicooe or describe all work required for
W performance and compWon of the
requirements of the contract On the basis
of the general scope indicated or described,
The trade contractors sholl fumish all items
required for the proper execution and
complabon of the work.
DRAWN by CRH
CHECKED by DDW
DATE issued 05 06.2008
REVISIONS
CEILING PLAN NOTES: 0 Z
1. 4' -0" INDUSTRIAL FLUORESCENT LIGHT FIXTURE. INSTALL AT 12' -0" AFF O
SUSPENDED FROM STRUCTURE ABOVE.
2. PATCH AND REPAIR EXISTING CEILING AS REQUIRED IN THIS SPACE.
~ N
W u. �
3. INSTALL NEW CEILING IN THIS SPACE. TIE INTO EXISTING CEILING THAT UJ N
REMAINS. PROVIDE ADDITIONAL FLUORESCENT LIGHT FIXTURES AS REQUIRED.
4. RELOCATED INDUSTRIAL LIGHT FIXTURE. PROVIDE (1) ADDITIONAL FIXTURE IN > v
THIS SPACE TO MATCH EXISTING. LOCATE SWITCHES NEAR MAN -DOOR. O V) z
t� Z �%o
0 o uU
o0 -�
O � �; O
� a
a� W Q
3 Z
Z o
_ a
00 O
qq Z
D
m
\ \ \ \ \ \ \ \ \\1llUl{II7���
KEYPLAN: °'''off .. „ ' %
Q�� erLG 1 S O,,
2 AR- 19 400087 a?
STATE OF IR
i "� Jnu uuu vv4
/,/,
; l/ /l //I AA
, /% AREA A
AREA OF
WORK
FIRST FLOOR AREA B
/ REFLECTED CEILING
AREA B PLAN
SCALE AS NOTED
L
'ARE A C "
A 102
00