HomeMy WebLinkAbout08040113.4COMBINATION EXIT LIGHT/ EMERGENCY LIGHT W/ BATTERY PACK PB C MR z__ - 0' -0' R D I rUR •A •p 0 VERIFY EXACT LOCATION OF EXHAUST FAN (TYPICAL) j I az' �PE EXISTING ELECTRICAL V MR- OA ■ MA Oil _ AI o KIM � r �ee� ii�ie� eeeee�eeeee� GE I L I NO PLAN I/all = I$_Oil . B A B 8' -2 B 8' -2" HATCHED AREA INDICATES AREA OF CEILING THAT IS DROPPED VERIFY EXACT LOCATION IN FIELD 1 F _ WAITING 201 C OMIT NURSE CALL COSMETIC EXAM L 203 ArGn� +4a ELEC.,TRIGAL PLAN VERIFY EXACT LOCATION killicA NOTE: WAITING ROOM CEILING TILES TO BE: ARMSTRONG - DUNE - TEGULAR (1775) W/ SUPRAFINE 9/16" EXPOSED TEE GRID ALL OTHER AREAS TO BE: ARMSTRONG - CIRRUS SQUARE LAY -IN W/ PRELUDE 15/16" EXPOSED TEE GRID VERIFY EXACT LOCATION IN FIELD TYP. UNLESS NOTED 9'-70"1 OTHERWISE VERIFY EXACT LOCATION AND SPECS. OF TENANT PROVIDED LIGHT FIXTURE (TYP. ® 4 LOCATIONS) ADDITIONAL OVERHEAD SUPPORT REQUIRED "A ) OMIT (1) DATA /TELE 0 WALL MOUNTED EXAM LIGHT (VERIFY HEIGHT) TYPICAL @ 9 LOCATIONS PROVIDE BLOCKING AS NECESSARY VERIFY ALL ELECTRICAL LOCATIONS AND REQUIREMENTS WITH TENANT VERIFY EXACT LOCATION IN FIELD ir , . Ck" .-*t A" ADD HORN & STROBE LOCATIONS TO PLAN FIRE ALARM LE6END �H HORN /STROBE 0 STROBE 5�0FE DO�UIIENTS THE DOCUMENTS ARE INTENDED TO INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF DESIGN CONCEPT, DIMENSIONS, AND MAJOR ARCHITECTURAL ELEMENTS. THESE DOCUMENTS DO NOT NECESSARILY DESCRIBE OR INDICATE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, EACH TRADE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THIS WORK. CENERAL NOTES 1. THE DRAWINGS AND SPECS. ARE AN INSTRUMENT OF SERVICE AND ARE THE SOLE PROPERTY OF THE ARCHITECT. ANY RE -USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ARCHITECT. 2. THE DRAWINGS AND SPECS. ARE THE SOLE PROPERTY OF THE OWNER. ANY RE -USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE OWNER. 3. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES, LAWS, AND ORDINANCES. 4. VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDING. 5. EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE. 6. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS REQUIRED BY LAW, CODE OR ORDINANCE AND AS OTHERWISE REQUIRED. 7. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE JOB SITE DAILY. 8. ALL MATERIALS SUSPENDED FROM STRUCTURE ABOVE SHALL BE HUNG FROM THE TOP CHORD OF THE JOIST. THIS INCLUDES BUT IS NOT LIMITED TO BULKHEADS, SPRINKLER LINES, CEILINGS, GAS PIPING, STORM WATER, ELECTRICAL CONDUIT, ETC. 9. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS AND THE PAYING OF ALL REQUIRED FEES. 10. ALL DIMENSIONS ARE FROM FINISH FACE TO FINISH FACE; DRYWALL TO DRYWALL, DRYWALL TO MASONRY, OR WOOD PANELING TO DRYWALL. 11. ALL INTERIOR FINISHES SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 12. ADA - TENANT BUILD OUT DESIGN HAS BEEN BASED UPON OUR TRAINING AND UNDERSTANDING OF THE REGULATIONS AND GUIDELINES ISSUED AS COMPONENT PARTS TO TITLE III OF THE AMERICANS WITH DISABILITIES ACT, PUBLIC LAW 101 -336. DESIGN RESOLUTION DOES NOT ATTEMPT TO ADDRESS POTENTIAL CONCERNS ASSOCIATES WITH OTHER TITLES OF THE ACT THAT IMPLICATE POLICY, PROCEDURES, AND TELECOMMUNICATIONS ISSUES. 13. ALL EXIT DOOR LOCKS SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 14. DOOR CLOSERS AT INTERIOR DOORS SHALL BE ADJUSTED SO THAT THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL NOT EXCEED 5 LBS. 15. INTERIOR DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 IN. FROM THE LATCH TO THE LEADING EDGE OF THE DOOR. 16. ALL MECHANICAL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 17. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 18. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 19. VERIFY WITH "CORNERSTONE DEVELOPMENT" ALL BUILDING STANDARD MATERIALS & SYSTEMS. REFLEC.,TED C.,E I L I NG-; LE5E D _ NEW GYPSUM WALLBOARD CEILING 0 SEE REFLECTED CEILING PLAN FOR HEIGHT E) NEW 2'x2' CEILING GRID ® BUILDING STANDARD 2x4 LAY -IN ® FLUORESCENT LIGHT FIXTURE OFLOOR BUILDING STANDARD 2x4 LAY -IN Lid FLUORESCENT NIGHT -LIGHT FIXTURE 0 M WALL MOUNTED LIGHT SWITCH dim WALL MOUNTED LIGHT SWITCH ON DIMMER BUILDING STANDARD EXIT SIGN BUILDING STANDARD DIFFUSER z BUILDING STANDARD RETURN AIR GRILLE 0 BUILDING STANDARD RECESSED INCANDESCENT CAN LIGHT E) BUILDING STANDARD RECESSED EXHAUST FAN Q INDIRECT /DIRECT LINEAR PENDANT ® FINELITE - SERIES 12 -P; 8' LONG; SUSPENDED OFLOOR 12" FROM CEILING — 220V SUBMIT SPEC. TO ARCHITECT FOR APPROVAL 0 M 2 -1/2" DIA. MR16 RECESSED LIGHT FIXTURE BRUCK - LEDRA 12 W/ J -BOX & DRIVER 135653 -1 /S, WARM WHITE SUBMIT SPEC. TO ARCHITECT FOR APPROVAL TENANT PROVIDED CEILING MOUNTED OVERHEAD LIGHT FIXTURE VERIFY EXACT LOCATION • NC NURSE CALL WS! WALL SCONCE LIGHT FIXTURE - VERIFY SPECIFICATIONS AND HEIGHT WITH SCHMIDT ASSOCIATES ELEC.,fiRl CAL LEOEND. Q WALL MOUNTED DUPLEX OUTLET �p WALL MOUNTED DEDICATED DUPLEX OUTLET (�D[ZGFI WALL MOUNTED GFI DUPLEX OUTLET Q WALL MOUNTED COMBINATION TELEPHONE /DATA LINE a WALL MOUNTED TELEPHONE LINE OFLOOR MOUNTED DUPLEX OUTLET - VERIFY EXACT LOCATION — 220V WALL MOUNTED SINGLE PHASE, 220V OUTLET WALL MOUNTED QUADRUPLEX OUTLET <E)OO' FLAN 1 5EGOND FLOOR SIMMONS ARCHITECTS, LLC ARCHITECTS, PLANNERS 305 East New York Street Indianapolis, Indiana 46204 (317) 656 -3500 Fax (317) 656 -3501 W� O � rT, 00 N i W W N W ...-, � zx 00 `j O E-� CD M C/1 N Q O O 00 � d o0 LO LO Z CO 9) c� Q� U � z V W H cv C.�N�o UA o1z� o Z _j Z � Q cf) WO Co U�^zi Q Z < CL CL zw V m z O LIA W (:)) Q WO BTU m O 0 cr CL Q <3 Q m0 in r m Y zs < W m co 0 CERIIRED BY: A. �Q•••.P�CISTE RO Q: :y • 3135 Ol • 0. _ STbq ' O EL M p W o � a �u °$ o a r ZZ N o �NOE101 MEGH /ELEG .