HomeMy WebLinkAbout08040147.6cn z Q n W cn (n O n • • O C_ U U ..._ .............. _ ..... ....... _................... .... ..... � _-.__ .......... ........... _ ........ _..... _..._.._. �, EXTEND EXISTING WATER SUPF'Crwo TO NEW SHOWER COORDINATE WTH ATAPCO. CONNECT DRAM FOR NEW if - - SHOWER t0 EXISTING DRAIN. - ' r -- :.= ::,::I .. CONTRACTOR TO VERIFY 0 I LOCATION AND SIZE OF EXISTING DRAM. COORDINATE '; , �� :: WITH ATAPCO. :::......�......... -_ - .ASSUMED LOCATION OF ' S,ANITARI' SEWER LINE. O CONTRACTOR TO VERIFY LOCATION OF EXISTING SUPPLY AND RETURNS. ATTACH NEW SUPPLY DIFFUSERS TO EXISTING HVAC SYSTEM TO MATCH CURKNT INSTALLATION, IF REQ!D. INSTALL NEW RETURN GRILLE M NEW GRID. lk INSTALL NEW EXHAUST FAN. CONK ECT TO EXISTING EXHAUST SYSTEM. �r EXTEND EXISTING WATER SUPPLY TO NEW COFFEE MAKER CAP SUPPLY. COORDINATE WITH ATAPCO. EXTEND EXISTING WATER SUPPLY TO NEW DISHWASHER. CAP SUPPLY. COORDINATE WITH ATAPCO. EXTEND EXISTING WATER SUPPLY TO NEW ICE MAKER 0 RERIGERATOR CAP SUPPLY. COORDINATE WITH ATAPCO. EXTEND EXISTING WATER TO NEW SINK COORDINAI WITH ATAPCO. PLUMBING FIXTURES BIDDING DOCUMENTS DESCRIPTION MANUF. 4 MODEL • ACCESSORIES 10-1 SHOWER BEST BATH LC83838A5B OR EQUAL GRAB BARS, FOLD -U' SEAT, SOAP DTE A DATE DISH, CURTAIN ROD AND MIXING ATEE DATE ADATE VALVE P -2 DOUBLE BOW- SING ELKAY LUSTERTONE LP40519 OR EQUAL ELKAY LKSII ARC TUBE FAUCET OR PLANS EQUAL. INSINKERATOR GARBAGE DISPOSAL. El III, ;P CONTRACTOR TO VERIFY LOCATION OF EXISTING SUPPLY AND RETURNS AND RELOCATE DIFFUSERS AS REQUIRED TO MEET I -EATNG AND COOLING REQUIRS TENTS. INSTALL NEW EXHAUST FAN. CONNECT TO EXISTING EXHAUST SYSTEM. P -2 CONNECT DRAM FOR NEW SINK TO EXISTING DRAIN. - CONTRACTOR TO VERIFY ® LOCATION AND SIZE OF EXISTING DRAIN. COORDINATE WITH ATAPCO. a OR s J CONTRACTOR TO VERIFY LOCATION OF EXISTING SUPPLY AND RETURN AND RELOCATE DIFFUSERS AS REQUIRED T( MEET HEATING AND COOLING REQUIREMENTS LINEAR SUPPLY DIFFUSERS TO REMAIN IN ALL LOCATIONS, UNLESS IN CONFLICT WTH NEW WALL CONSTRUCTION i PLUMBING PLAN SCALE: 3/32' ■ 1' -0' ❑- MECHANICAL PLAN SCALE: 3/32' ■ 1' -0' ADD RETURN AIR GRILL TO EXISTING GRID ADD RETURN AIR GRILL TO EXISTING GRID ADD RETURN AIR GRILL TO EXISTING GRID PLUMBING NOTES IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR To VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTANING TO HIS PHASE OF THE WORK IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNER'S OF THE VARIOUS UTILITIES BEFORE WORK IS STARTED. ATAPCO REQUIREMENTS SHALL BE STANDARDS FOR THIS PROJECT UNLESS NOTED OT14ERtUSE. CONTRACTOR SHALL INSPECT SITE TO THOROUGHLY FAMILIARIZE HIMSELF WITH THE AREA OF WORK THESE DOGImTNTS DO NOT REFLECT AS -BUILT CONDITIONS. ANY DISCREPANCIES BETUUEEN THESE DOCUMENTS AND ACTUAL CONDITIONS SHALT. BE REPORTED TO THE ARCHITECT FOR RESOLUTION PRIOR TO BID PRICING. NO EXTRAS WILL BE ALLOWED DUE TO LACK OF KNOWLEDGE OF EXISTING CONDITIONS. WHERE WATER LINES AND SANITARY SEWER LINES CANNOT BE PLACED ABOVE THE SEWER WITH A MINIMUM OF 18' VERTICAL CLEARANCE, THE SEWER MUST BE CONSTRUCTED OF WATER WORKS GRADE CAST IRON PIPE WITH MECHANICAL JOINTS WTHIN 10' OP THE WATER LINE. EXISTING BUILDING IS FULLY SPRUKLERED. CONTRACTOR IS RESPONSIBLE FOR THE RECONFIGURATION AND TESTING OF THE EXSTMG SPRINKLER SYSTEM. CONTRACTOR TO COORDINATE WITH NEW CONSTRUCTION AND TO MEET THE APPLICABLE SPRINKLER CODES. MECHANICAL NOTES THIS DRAWING REPRESENTS THE GENERAL. SCOPE OF THE PROJECT M TERMS OF THE MECHANICAL DESIGN CONCEPT BUT DOES NOT NECESSARILY INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFOF MANCE AND /OR COMPLETION OF THE CONTRACT. THE TRADE CONTRACTORS SHALL PERFORM SUCH SERVICES TIE. DUCTWORK LAYOUT AND SIZE DIAGRAMS, EQUIPMENT CUT SHEETS, ETCH AND FURNISH ALL ITEMS REQUIRED FOR THE RILL AND PROF -+ER EXECUTION OF THE PROJECT. ATAPCO REQUIREMENTS SHALL BE STANDARDS FOR THIS PROJECT UNLESS NOTED. IF NO STANDARDS ARM AVAILABLE, RECTANGULAR DUCTWORK SUPPLY AND RETURN SHALL BE SHEET METAL AND SHALL BE EXTERNALLY INSULATED WITH 1/2' FOIL FACED 15 PCF DUCT WRAP. ROUND DUCTWORK SHALL BE SHEET METAL AND WRAPPED WITH 14' DUCT WRAP. EXHAUST DUCTWORK SHALL BE SHEET METAL AND SHALL BE UNLINED. ALL DUCTWORK SHALL MEET OR EXCEED S OO" STANDARDS FOR 2' PRESSURE CLASSIFICATION. ALL DUCTWORK SHALL BE SEALED AIRTIGHT WITH DUCT SEALANT AND SHALL CONFORM TO LOCAL BUILDING CODES. FLEXIBLE DUCTWORK SHALL BE INSULATED AND SHALL BE THE SAME SIZE AS THE NECK OF THE DIFFUSER FLEX DUCT SHALL NOT EXCEED V -0' IN LENGTH AND 54 LL CO FORM TC LOCAL BUILDNG CODES. FALL SPIN-N FITTINGS SHALL BE CONICAL AND SHALL HAVE MANUAL VOLUME DAMPERS. RECTANGULAR BRANCH DUCT TAKE -OFFS SHALL HAVE 45 DEGREE TAKE -OFFS AND ROUND DUCT TAKE -OFFS SHALL BE CONICAL. ALL ELBOWS, BOTH HORIZONTAL AND VERTICAL, SHALL BE LONG RADIUS ELBOWS WHEREVER POSSIBLE OR SHALL HAVE TURNING VALVES AS NEEDED. BALANCE AIR SYSTEM AND SUBMIT A BALANCE REPORT TO AR141TECT FOR REVIEW. THERMOSTATS ARE EXISTING AND SHALL REMAIN IN EXISTING LOCATIONS UNLESS REQUIRED TO BE RELOCATED BY THE CONSTRUCTION OF NEW WALLS. CONTRACTOR SHALL INSPECT SITE TO THOROUGHLY FAMILIARIZE HIMSELF WITH TIRE AREA OF WORK TRESS DOCUMENTS DO NOT REFLECT AS -BUILT CONDITIONS. ANY DISCREPANCIES BETWEEN T14ESE DOCUMENTS AND ACTUAL CONDITIONS SHALL BE REPORTED TO THE ARCHITECT FOR RESOLUTION PRIOR TO BID PRICMG. NO EXTRAS WILL BE ALLOWED DUE TO LACK OF KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR'S SCOPE OF RESPONSIBILITY INCLUDES THE INSTALLATION OF NEW DIFFUSERS AND GRILLES, THE RELOCATION EXISTING DIFFUSERS AND GRILLES, THE INSTALLATION OF THE NEW EXHAUST FANS WI-ERE INDICATED, THE REMOVAL OF LINEAR DIFFUSERS WERE IN CONFLICT WITH NEW CONSTRUCTION AND ALL WORK RELATED TO THE ABOVE MENTIONED ITEMS, INCLUDING THE 5AL4NCMG OF THE SYSTEM. THE CONTRACTOR 18 NOT RESPONSIBLE FOR NORMAL MAINTENANCE ITEMS UNDER TIRE SCOPE OF ATAPCO. DIFFUSER AND GRILLE LOCATIONS ARE APPROXIMATE. MECHANICAL CONTRACTOR SHALL COORDINATE LOCATION WITH OTHER TRADES. Peterson Architecture 802 Mulberry Street. Suite G Noblesville, IN 46060 p 317.770.9714 f 317.770.9718 studio @petersonarchitecture.com W J w LL o U) LL 0 0 az a �� 0 F U UO J O -� w w 0 � U � THESE DRAWINGS ARE GIVEN M COWIDENCE AND SHALL BE USED ONLY IN PURWANT TO THE AGREEMENT WITH PETERSON ARCHITECRRE, PC, NO OTHER USE OR DUPLICATION MAY BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF PETERSON ARCHITECTURE, PiC. ALL OTHER COPYRIGHT AND COMMON LAW RIGHTS ARE HEREBY SPECIFICALLY RESERVED. BIDDING DOCUMENTS MARCH 10, 2008 FIEVISIONS A REV A DTE A DATE ATEE DATE ADATE DRAWER NO. IS DRAWN BY L ANDERSON CF ECKED BY- D. PETERSON PROJECT NUMBER 08 -0020 MECHANICAL AND PLUMBING PLANS mplol THESE DRAWINGS ARE GIVEN M COWIDENCE AND SHALL BE USED ONLY IN PURWANT TO THE AGREEMENT WITH PETERSON ARCHITECRRE, PC, NO OTHER USE OR DUPLICATION MAY BE MADE WITHOUT THE PRIOR WRITTEN CONSENT OF PETERSON ARCHITECTURE, PiC. ALL OTHER COPYRIGHT AND COMMON LAW RIGHTS ARE HEREBY SPECIFICALLY RESERVED.