EXTEND EXISTING WATER SUPF'Crwo
TO NEW SHOWER COORDINATE
WTH ATAPCO.
CONNECT DRAM FOR NEW if - -
SHOWER t0 EXISTING DRAIN. - ' r --
:.= ::,::I ..
CONTRACTOR TO VERIFY 0 I
LOCATION AND SIZE OF
EXISTING DRAM. COORDINATE '; , ��
::
WITH ATAPCO. :::......�.........
-_ - .ASSUMED LOCATION OF
' S,ANITARI' SEWER LINE.
O
CONTRACTOR TO VERIFY LOCATION
OF EXISTING SUPPLY AND RETURNS.
ATTACH NEW SUPPLY DIFFUSERS TO
EXISTING HVAC SYSTEM TO MATCH
CURKNT INSTALLATION, IF REQ!D.
INSTALL NEW RETURN GRILLE M NEW
GRID. lk
INSTALL NEW EXHAUST FAN.
CONK ECT TO EXISTING EXHAUST
SYSTEM.
�r
EXTEND EXISTING WATER SUPPLY TO NEW COFFEE
MAKER CAP SUPPLY. COORDINATE WITH ATAPCO.
EXTEND EXISTING WATER SUPPLY
TO NEW DISHWASHER. CAP SUPPLY.
COORDINATE WITH ATAPCO.
EXTEND EXISTING WATER SUPPLY
TO NEW ICE MAKER 0 RERIGERATOR
CAP SUPPLY. COORDINATE
WITH ATAPCO.
EXTEND EXISTING WATER
TO NEW SINK COORDINAI
WITH ATAPCO.
PLUMBING FIXTURES
BIDDING DOCUMENTS
DESCRIPTION
MANUF. 4 MODEL •
ACCESSORIES
10-1
SHOWER
BEST BATH LC83838A5B OR EQUAL
GRAB BARS, FOLD -U' SEAT, SOAP
DTE
A
DATE
DISH, CURTAIN ROD AND MIXING
ATEE
DATE
ADATE
VALVE
P -2
DOUBLE BOW- SING
ELKAY LUSTERTONE LP40519 OR EQUAL
ELKAY LKSII ARC TUBE FAUCET OR
PLANS
EQUAL. INSINKERATOR GARBAGE
DISPOSAL.
El III,
;P
CONTRACTOR TO VERIFY LOCATION
OF EXISTING SUPPLY AND RETURNS
AND RELOCATE DIFFUSERS AS
REQUIRED TO MEET I -EATNG AND
COOLING REQUIRS TENTS.
INSTALL NEW EXHAUST FAN.
CONNECT TO EXISTING EXHAUST
SYSTEM.
P -2
CONNECT DRAM FOR NEW
SINK TO EXISTING DRAIN.
- CONTRACTOR TO VERIFY
® LOCATION AND SIZE OF
EXISTING DRAIN. COORDINATE
WITH ATAPCO.
a OR
s J
CONTRACTOR TO VERIFY LOCATION OF EXISTING SUPPLY
AND RETURN AND RELOCATE DIFFUSERS AS REQUIRED T(
MEET HEATING AND COOLING REQUIREMENTS
LINEAR SUPPLY DIFFUSERS TO REMAIN IN ALL LOCATIONS,
UNLESS IN CONFLICT WTH NEW WALL CONSTRUCTION
i
PLUMBING PLAN
SCALE: 3/32' ■ 1' -0'
❑-
MECHANICAL PLAN
SCALE: 3/32' ■ 1' -0'
ADD RETURN AIR GRILL TO EXISTING GRID
ADD RETURN AIR
GRILL TO EXISTING
GRID
ADD RETURN AIR
GRILL TO EXISTING
GRID
PLUMBING NOTES
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR To
VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTANING
TO HIS PHASE OF THE WORK IT SHALL ALSO BE THE
CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNER'S OF
THE VARIOUS UTILITIES BEFORE WORK IS STARTED.
ATAPCO REQUIREMENTS SHALL BE STANDARDS FOR THIS
PROJECT UNLESS NOTED OT14ERtUSE.
CONTRACTOR SHALL INSPECT SITE TO THOROUGHLY
FAMILIARIZE HIMSELF WITH THE AREA OF WORK THESE
DOGImTNTS DO NOT REFLECT AS -BUILT CONDITIONS. ANY
DISCREPANCIES BETUUEEN THESE DOCUMENTS AND ACTUAL
CONDITIONS SHALT. BE REPORTED TO THE ARCHITECT FOR
RESOLUTION PRIOR TO BID PRICING. NO EXTRAS WILL BE
ALLOWED DUE TO LACK OF KNOWLEDGE OF EXISTING
CONDITIONS.
WHERE WATER LINES AND SANITARY SEWER LINES CANNOT BE
PLACED ABOVE THE SEWER WITH A MINIMUM OF 18' VERTICAL
CLEARANCE, THE SEWER MUST BE CONSTRUCTED OF WATER
WORKS GRADE CAST IRON PIPE WITH MECHANICAL JOINTS
WTHIN 10' OP THE WATER LINE.
EXISTING BUILDING IS FULLY SPRUKLERED. CONTRACTOR IS
RESPONSIBLE FOR THE RECONFIGURATION AND TESTING OF
THE EXSTMG SPRINKLER SYSTEM. CONTRACTOR TO
COORDINATE WITH NEW CONSTRUCTION AND TO MEET THE
APPLICABLE SPRINKLER CODES.
MECHANICAL NOTES
THIS DRAWING REPRESENTS THE GENERAL. SCOPE OF THE
PROJECT M TERMS OF THE MECHANICAL DESIGN CONCEPT
BUT DOES NOT NECESSARILY INDICATE OR DESCRIBE ALL
WORK REQUIRED FOR THE FULL PERFOF MANCE AND /OR
COMPLETION OF THE CONTRACT. THE TRADE CONTRACTORS
SHALL PERFORM SUCH SERVICES TIE. DUCTWORK LAYOUT AND
SIZE DIAGRAMS, EQUIPMENT CUT SHEETS, ETCH AND FURNISH
ALL ITEMS REQUIRED FOR THE RILL AND PROF -+ER EXECUTION
OF THE PROJECT.
ATAPCO REQUIREMENTS SHALL BE STANDARDS FOR THIS
PROJECT UNLESS NOTED. IF NO STANDARDS ARM AVAILABLE,
RECTANGULAR DUCTWORK SUPPLY AND RETURN SHALL BE
SHEET METAL AND SHALL BE EXTERNALLY INSULATED WITH 1/2'
FOIL FACED 15 PCF DUCT WRAP. ROUND DUCTWORK SHALL BE
SHEET METAL AND WRAPPED WITH 14' DUCT WRAP. EXHAUST
DUCTWORK SHALL BE SHEET METAL AND SHALL BE UNLINED.
ALL DUCTWORK SHALL MEET OR EXCEED S OO"
STANDARDS FOR 2' PRESSURE CLASSIFICATION. ALL
DUCTWORK SHALL BE SEALED AIRTIGHT WITH DUCT SEALANT
AND SHALL CONFORM TO LOCAL BUILDING CODES.
FLEXIBLE DUCTWORK SHALL BE INSULATED AND SHALL BE
THE SAME SIZE AS THE NECK OF THE DIFFUSER FLEX DUCT
SHALL NOT EXCEED V -0' IN LENGTH AND 54 LL CO FORM TC
LOCAL BUILDNG CODES.
FALL SPIN-N FITTINGS SHALL BE CONICAL AND SHALL HAVE
MANUAL VOLUME DAMPERS.
RECTANGULAR BRANCH DUCT TAKE -OFFS SHALL HAVE 45
DEGREE TAKE -OFFS AND ROUND DUCT TAKE -OFFS SHALL BE
CONICAL.
ALL ELBOWS, BOTH HORIZONTAL AND VERTICAL, SHALL BE
LONG RADIUS ELBOWS WHEREVER POSSIBLE OR SHALL HAVE
TURNING VALVES AS NEEDED.
BALANCE AIR SYSTEM AND SUBMIT A BALANCE REPORT TO
AR141TECT FOR REVIEW.
THERMOSTATS ARE EXISTING AND SHALL REMAIN IN EXISTING
LOCATIONS UNLESS REQUIRED TO BE RELOCATED BY THE
CONSTRUCTION OF NEW WALLS.
CONTRACTOR SHALL INSPECT SITE TO THOROUGHLY
FAMILIARIZE HIMSELF WITH TIRE AREA OF WORK TRESS
DOCUMENTS DO NOT REFLECT AS -BUILT CONDITIONS. ANY
DISCREPANCIES BETWEEN T14ESE DOCUMENTS AND ACTUAL
CONDITIONS SHALL BE REPORTED TO THE ARCHITECT FOR
RESOLUTION PRIOR TO BID PRICMG. NO EXTRAS WILL BE
ALLOWED DUE TO LACK OF KNOWLEDGE OF EXISTING
CONDITIONS.
CONTRACTOR'S SCOPE OF RESPONSIBILITY INCLUDES THE
INSTALLATION OF NEW DIFFUSERS AND GRILLES, THE
RELOCATION EXISTING DIFFUSERS AND GRILLES, THE
INSTALLATION OF THE NEW EXHAUST FANS WI-ERE INDICATED,
THE REMOVAL OF LINEAR DIFFUSERS WERE IN CONFLICT WITH
NEW CONSTRUCTION AND ALL WORK RELATED TO THE ABOVE
MENTIONED ITEMS, INCLUDING THE 5AL4NCMG OF THE SYSTEM.
THE CONTRACTOR 18 NOT RESPONSIBLE FOR NORMAL
MAINTENANCE ITEMS UNDER TIRE SCOPE OF ATAPCO.
DIFFUSER AND GRILLE LOCATIONS ARE APPROXIMATE.
MECHANICAL CONTRACTOR SHALL COORDINATE LOCATION
WITH OTHER TRADES.
Peterson Architecture
802 Mulberry Street. Suite G
Noblesville, IN 46060
p 317.770.9714
f 317.770.9718
studio @petersonarchitecture.com
W J
w LL o
U)
LL 0
0
az
a ��
0
F U
UO J O -�
w
w
0 �
U �
THESE DRAWINGS ARE GIVEN M COWIDENCE
AND SHALL BE USED ONLY IN PURWANT TO THE
AGREEMENT WITH
PETERSON ARCHITECRRE, PC,
NO OTHER USE OR DUPLICATION MAY BE MADE
WITHOUT THE PRIOR WRITTEN CONSENT OF
PETERSON ARCHITECTURE, PiC.
ALL OTHER COPYRIGHT AND COMMON LAW
RIGHTS ARE HEREBY SPECIFICALLY RESERVED.
BIDDING DOCUMENTS
MARCH 10, 2008
FIEVISIONS
A
REV
A
DTE
A
DATE
ATEE
DATE
ADATE
DRAWER NO. IS
DRAWN BY L ANDERSON
CF ECKED BY- D. PETERSON
PROJECT NUMBER 08 -0020
MECHANICAL AND PLUMBING
PLANS
mplol
THESE DRAWINGS ARE GIVEN M COWIDENCE
AND SHALL BE USED ONLY IN PURWANT TO THE
AGREEMENT WITH
PETERSON ARCHITECRRE, PC,
NO OTHER USE OR DUPLICATION MAY BE MADE
WITHOUT THE PRIOR WRITTEN CONSENT OF
PETERSON ARCHITECTURE, PiC.
ALL OTHER COPYRIGHT AND COMMON LAW
RIGHTS ARE HEREBY SPECIFICALLY RESERVED.