HomeMy WebLinkAbout08060038.3LIGHTING
LEGEND
r LIGHT FIXTURE, 2'x4',
FLUORESCENT,
PRISMATIC
�® LIGHT FIXTURE, 2'x2',
FLUORESCENT,
PRISMATIC
LIGHT FIXTURE,
INCANDESCENT, CAN,
FLUSH MOUNTED
LIGHT FIXTURE, INCANDESCENT, PENDANT
A MFG: BESA LIGHTING
TO ORDER: WWW.LIGHTINGUNIVERSE.COM
STYLE: 3JC VILA THREE -LIGHT ROUND PENDANT
PART # 2291772
FINISH: SATIN NICKEL
GLASS: MAGMA
BOTTOM OF PENDANT TO BE. 66" A.F.F.
APPROVE HEIGHT WITH TENANT PRIOR TO
INSTALL.
OB LIGHT FIXTURE, INCANDESCENT, PENDANT
MFG: BESA LIGHTING
TO ORDER: WWW.LIGHTINGUNIVERSE.COM
STYLE: 1JC VILA PENDANT
PART # 2287087
FINISH: SATIN NICKEL
GLASS: MAGMA
BOTTOM OF PENDANT TO BE 60" A.F.F.
APPROVE HEIGHT WITH TENANT PRIOR TO
INSTALL.
LIGHT FIXTURE, HALOGEN, PENDANT
® MFG: PLC LIGHTING
C TO ORDER: WWW.LIGHT[NGUNIVERSE.COM
STYLE: 21086 JULIUS MULTI -LIGHT PENDANT
PART # 2115217
FINISH: SATIN NICKEL
BOTTOM OF PENDANT TO BE 78" A.F.F.
APPROVE HEIGHT WITH TENANT PRIOR TO
INSTALL.
LIGHT FIXTURE, INCANDESCENT, PENDANT
D MFG: ELK LIGHTING, INC
TO ORDER: WWW.LIGHTINGUNIVERSE.COM
STYLE: 110 -6 SIX LIGHT MILAN MULTI -LIGHT
PENDANT
PART # 2692622
FINISH: SATIN NICKEL
GLASS: FIRE RED
BOTTOM OF PENDANT TO BE 78" A.F.F.
APPROVE HEIGHT WITH TENANT PRIOR TO
INSTALL.
® EXIT LIGHT FIXTURE
NL INDICATES NIGHT
LIGHT LOCATION
$N LIGHT SWITCH
$N3 LIGHT SWITCH, 3 -WAY
$N4 LIGHT SWITCH, 4 -WAY
NEW LIGHT CIRCUIT
FIRE
PROTECTION /LIFE
SAFETY GENERAL
� NOTES
LIGHTING
� GENERAL NOTES
EL1. ELECTRIC LIGHTING WORK GENERALLY INDICATED BY
THIS DRAWING IS TO BE PROVIDED BY DESIGN /BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A
COMPLETE, FUNCTIONAL SYSTEM.
EL2. COMPLY WITH THE INDIANA ELECTRICAL CODE AND
ALL OTHER APPLICABLE CODES.
EL3. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW
CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE
EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT
FIXTURES.
EL4. ENSURE THAT ALL MOUNTING HEIGHTS OF
ELECTRICAL DEVICES MEET A.D.A. REQUIREMENTS.
EL5. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE
(1) GANG BOX WITH A SINGLE COVERPLATE.
EL6. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE
IF REQUIRED. EMERGENCY LIGHTS WITH BATTERY PACKS
OR LIGHTS CONNECTED TO AN EMERGENCY POWER
SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50
PERSONS OR MORE.
EL7. PROVIDE EXIT SIGNS, HORNS, STROBES, SPEAKERS,
OR OTHER LIFE — SAFETY DEVICES AS NECESSARY TO
MEET ALL APPLICABLE CODES. COORDINATE WITH THE
TENANT ALL HORN /STROBE LOCATIONS IN RECEPTIONS
& CONFERENCE ROOMS TO AVOID CONFLICT WITH
PRESENTATION BOARDS, A/V EQUIPMENT, & PROJECTION
SCREENS, PRIOR TO INSTALLATION. REFER TO FIRE &
LIFE SAFETY GENERAL NOTES FOR CONTRACTOR'S
RESPONSIBILITY TO FILE LIFE SAFETY SYSTEM DEVICE
PLANS WITH THE INDIANAPOLIS FIRE DEPARTMENT.
EL8. IF REQUIRED AND AS NECESSARY, PROVIDE NEW
BALLASTS AND LAMPS IN ALL LIGHTS IN EXISTING
SPACES. CONSULT WITH LANDLORD.
REFLECTED CEILING
GENERAL NOTES
RC1. GRID IS 2'X4' AT 9' -8" A.F.F. TILES ARE 2'X4'
ARMSTRONG CORTEGA SECOND LOOK #2767.
REFLECTED CEILING
LEGEND
CEILING GRID,
SUSPENDED, 2'x4'
= AREA OF WORK
NO SCALE
PAP M:
LIGHTING
KEYNOTES
ui
zN�
E01 VERIFY EXACT LOCATION OF PENDANT WITH
TENANT AND TENANT'S FURNITURE PROVIDER.
w
Qoz
z��
LIGHTING
� GENERAL NOTES
EL1. ELECTRIC LIGHTING WORK GENERALLY INDICATED BY
THIS DRAWING IS TO BE PROVIDED BY DESIGN /BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A
COMPLETE, FUNCTIONAL SYSTEM.
EL2. COMPLY WITH THE INDIANA ELECTRICAL CODE AND
ALL OTHER APPLICABLE CODES.
EL3. VERIFY EXISTING LIGHTING CIRCUITING. SIZE NEW
CIRCUITS AS REQUIRED. PROVIDE NEW OR REVISE
EXISTING CIRCUITING FOR NEW LAYOUT OF LIGHT
FIXTURES.
EL4. ENSURE THAT ALL MOUNTING HEIGHTS OF
ELECTRICAL DEVICES MEET A.D.A. REQUIREMENTS.
EL5. WHERE MULTIPLE SWITCHES ARE SHOWN, PROVIDE
(1) GANG BOX WITH A SINGLE COVERPLATE.
EL6. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE
IF REQUIRED. EMERGENCY LIGHTS WITH BATTERY PACKS
OR LIGHTS CONNECTED TO AN EMERGENCY POWER
SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50
PERSONS OR MORE.
EL7. PROVIDE EXIT SIGNS, HORNS, STROBES, SPEAKERS,
OR OTHER LIFE — SAFETY DEVICES AS NECESSARY TO
MEET ALL APPLICABLE CODES. COORDINATE WITH THE
TENANT ALL HORN /STROBE LOCATIONS IN RECEPTIONS
& CONFERENCE ROOMS TO AVOID CONFLICT WITH
PRESENTATION BOARDS, A/V EQUIPMENT, & PROJECTION
SCREENS, PRIOR TO INSTALLATION. REFER TO FIRE &
LIFE SAFETY GENERAL NOTES FOR CONTRACTOR'S
RESPONSIBILITY TO FILE LIFE SAFETY SYSTEM DEVICE
PLANS WITH THE INDIANAPOLIS FIRE DEPARTMENT.
EL8. IF REQUIRED AND AS NECESSARY, PROVIDE NEW
BALLASTS AND LAMPS IN ALL LIGHTS IN EXISTING
SPACES. CONSULT WITH LANDLORD.
REFLECTED CEILING
GENERAL NOTES
RC1. GRID IS 2'X4' AT 9' -8" A.F.F. TILES ARE 2'X4'
ARMSTRONG CORTEGA SECOND LOOK #2767.
REFLECTED CEILING
LEGEND
CEILING GRID,
SUSPENDED, 2'x4'
= AREA OF WORK
NO SCALE
PAP M:
7128 waldemar drive
indianapolis, indiana 46268
p: 31 7.387.1 700
f: 31 7-387.1770
www.schottdesign.com
ui
zN�
w
Qoz
z��
0O�= 6
J z
a
0
vUi0w
0
oz
U
z
p�?O
Cie
■
U
04)
°oo
0
41b
Q
V
Q
zQoz
9 =) wvwi
W
(D
z
w 0
7C)
o�OU
■
QU- °w
>
Z
W
W
V�
�
W�u
0w
o J �
~
�
z U r r
Qwp�
c
C�w,z O
z? <�
W
CL
Q o
..J
�Qz
o z <
W
,,, w
= w U
0
=z
7128 waldemar drive
indianapolis, indiana 46268
p: 31 7.387.1 700
f: 31 7-387.1770
www.schottdesign.com
ISSUE:
DATE DESCRIPTION
REVISONS:
DATE I DB IDESCRIPTION
Ilpl
Ft. S
No.10100042
STATE OF
PROJECT #:
2008.031
PROJ. MGR: DRAWN BY:
AMM MJ
REFLECTED
CEILING PLAN
A121
0
Q
Z
I
z
Cie
_
z
04)
LCu
0
41b
G
DC
Q
V
Q
Lou,*
W
o
m
W
W
F.—
>
Z
W
V
W
V�
�
W�u
~
�
co
um
W
..J
W
0
ISSUE:
DATE DESCRIPTION
REVISONS:
DATE I DB IDESCRIPTION
Ilpl
Ft. S
No.10100042
STATE OF
PROJECT #:
2008.031
PROJ. MGR: DRAWN BY:
AMM MJ
REFLECTED
CEILING PLAN
A121