HomeMy WebLinkAbout08050111.7LAV: HOT %" COLD z" 1Y" DIR. DRAIN TOILET: 12"1 i %4" COLD 3" DIR. DRAIN \ FL00 12" FLOOR TOILET: 4 DRAI I ODRAIN Y4 "COLD (} -- — - -L — / 3" DIR. DRAIN 14" r EXISTING 6" SANITARY L T J SEWER DRAIN - V.I.F. HOT WATER DELIVERY UNIT PROVIDE BY OWNER - CONTRACTOR TO PROVIDE Yz" COLD WATER ROUGH -IN DUAL TANKLESS HOT WATER SYSTEM MOUNTED ON WALL - VERIFY REQUIREMENTS IN THE FIELD FLOOR SINK LAV. -TYP. n— 2„ — PO 000 DRAIN 1 FLOOR T 7q DRAIN �«} - - -Z�. — O — — — — — — — 2„ HAND SINK: HOT /2" O to COLD %" 1%" DIR. DRAIN 14„ I I I I HAND SINK: HOT %" 1 COLD/1/9" 1%" DIR. DRAIN - I 1 Y° 14" 1 FLOOR 2" DRAIN o- 1 I I I I 14„ 1 FLOOR I DRAIN I BEV, I DISPENSER: 4" INDIR. 1 DRAIN 12" ,II I ICE MAKER/BIN: 1 COLD 4" 1 4" INDIR. DRAIN 1 I 12„ i HAND SINK: HOT %" COLD %" 1%" DIR. DRAIN I_ FLOOR SINK F7 :FE I� MOP SINK: HOT z" COLD %" 1%" DIR. DRAIN NEW TENANT GREASE TRAP UNDER SLAB (70 LBS.) LOCATED IN "DOUGH ROOM" URINAL: - PROVIDE FLOOR ACCESS 4" COLD 1Y" DIR. DRAIN TOILET: Y4" COLD 3" DIR. DRAIN 1 -BAY SINK: HOT Y" COLD Y2" 1)/2" INDIR. DRAIN DISHWASHER: HOT Y4" -FLOOR 2" INDIR. DRAIN SINK 3 -BAY SINK PROVIDED BY KITCHEN EQUIPMENT SUPPLIER PLUMBING CONTRACTOR TO PROVIDE ROUGH -INS FOR: HOT %" COLD' 2" 1J/2" INDIR. DRAIN GENERAL NOTES: THIS PROJECT IS A TENANT BUILD -OUT OF AN EXISTING INTERIOR SPACE. DEMISING WALLS AND EXTERIOR WALLS ON ALL FOUR SIDES ARE EITHER EXISTING OR SHALL BE CONSTRUCTED BY THE BUILDING LANDLORD. ALL NEW CONSTRUCTION SHALL COMPLY WITH THE REQUIREMENTS OF TYPE V -B CONSTRUCTION. ALL PLUMBING INSTALLATIONS SHALL COMPLY WITH THE INDIANA PLUMBING CODE. CONFIRM REQUIREMENTS IN THE FIELD. REFER TO KITCHEN EQUIPMENT PLAN (SHEET A2) FOR ALL EQUIPMENT PLUMBING REQUIREMENTS. INSTALL CLEANOUTS AND BACKFLOW PREVENTER(S) AS REQUIRED - VERIFY IN THE FIELD CONTRACTOR TO INSTALL BACKFLOW PREVENTOR AS REQUIRED BY INDIANAILOCAL BUILDING CODES PLUMBER TO PROVIDE MIXING VALVE - LOCATION TO BE DETERMINED IN THE FIELD PLUMBER TO PROVIDE AND INSTALL HAND SINKS DEPTH OF EXISTING SANITARY DRAIN MUST BE VERIFIED IN THE FIELD LOCATION AND SIZE OF EXISTING WATER SUPPLY PIPING MUST BE VERIFIED IN THE FIELD TOILETS TO BE FLUSH -VALVE PROVIDED AND INSTALLED BY CONTRACTOR PROVIDE SOFTENED WATER TO DISH WASHING AREA ONLY PLUMBING-PILAU Z ®� 0 V 2' 4' 8' SCOGGINS D E S I G N INC. 8954 BECKFORD DRIVE INDIANAPOLIS, IN 46234 TEL. (317) 435 -7321 www.scogginsdesign.com THESE DOCUMENTS, AND ALL REPRODUCTIONS THEREOF, SHALL REMAIN THE PROPERTY OF THE DESIGNER. THEY SHALL NOT TO BE USED FOR ANY OTHER PROJECT WITHOUT THE PRIOR WRITTEN PERMISSION OF THE DESIGNER. PROJECT NO. 27.120 PROJECT DATE MARCH 18, 2008 DRAWN BY TRS REVISED - -- FILE NAME A06.DWG COPYRIGHT 2008 SCOGGINS DESIGN, INC. \ \ \ \R 1 I ► I Sc ,,,00 ...................cc•,,, 0 : p No.10100042 STATE OF � '9 AND I ��� Ic �►I 1 OWNER: M , LLC 405 North Hershey Road Bloomington, IL 61704 Monicals PIZZA HAMILTON CROSSING ca N N v ca U O Q Z Q z J W Off a U Q Cn � (n W O U Z Iy 00 J z r Q L0 _ r PLUMBING PLAN E