Loading...
HomeMy WebLinkAbout08040129.18LIGHTING FIXTURE NOTES: NOTES LF1 - LF23 ARE GENERAL NOTES APPLICABLE TO ENTIRE LIGHTING FIXTURE SCHEDULE WHERE APPROPRIATE. LF1 - PROVIDE ALL PARABOLIC TROFFERS WITH MINIMUM 3 INCH LOUVER, SPRING LOADED LATCHES, AND PAINT AFTER FABRICATION WITH POLYESTER PAINT. THE PARABOLIC SHAPE OF THE LOUVER SHALL ENVELOP THE LAMP IN A FULLY REFLECTIVE CAVITY WHICH SHALL ELIMINATE LIGHT LEAKS BETWEEN ROWS OF CELLS. LF2 - PROVIDE SEMI - SPECULAR LOW IRIDESCENT TYPE LOUVERS AND REFLECTORS. LF3 - ALL COMPACT FLUORESCENT BALLASTS SHALL BE ELECTRONIC WITH END OF LAMP LIFE PROTECTION. LF4 - PROVIDE ALL NECESSARY COMPONENTS AND ACCESSORIES FOR A COMPLETE OPERATING INSTALLATION PER APPLICABLE CODES AND MANUFACTURER'S RECOMMENDATIONS. LF5 - PROVIDE CEILING SPACERS AS REQUIRED FOR ALL SURFACE MOUNTED FIXTURES UNLESS FIXTURE IS LABELED AS SUITABLE FOR DIRECT MOUNTING TO A LOW DENSITY CEILING. LF6 - PROVIDE SLOPE ADAPTERS FOR ALL SURFACE MOUNTED, RECESSED, SUSPENDED FIXTURES AND LIGHT TRACK AS NEEDED TO ACCOMMODATE THE SLOPE OF THE CEILING. LF7 - INCLUDE IN THE BASE BID THE COST FOR FURNISHING, INSTALLING, WIRING AND CONNECTING FOR A COMPLETE OPERATING INSTALLATION AN ADDITIONAL EXIT FIXTURE OF EACH TYPE INDICATED IN THE LIGHTING FIXTURE SCHEDULE. LF8 - CONTRACTOR SHALL REVIEW THE ENTIRE LIGHTING FIXTURE SCHEDULE INCLUDING THE DESCRIPTION AND CATALOG NUMBER. CONTRACTOR SHALL NOTIFY THE A/E OF ANY DISCREPANCIES PRIOR TO BIDDING. LF9 - VERIFY ALL FINISHES /COLORS OF FIXTURES WITH A/E PRIOR TO ORDERING. LF10 - CONTRACTOR SHALL VERIFY THAT THE FIXTURE INSTALLATION TYPE IS COMPATIBLE WITH CEILING CONSTRUCTION PRIOR TO INSTALLATION. LF11 - FOR FIXTURES LISTED IN SCHEDULE WITH (E) ELECTRONIC TYPE BALLASTS, OR (S) HID TYPE BALLAST, PROVIDE A BALLAST AS INDICATED IN, SPECIFICATION. LF12 - CONTRACTOR SHALL PROVIDE BALLASTS AND WIRING IN COMPLIANCE WITH THE STATE ENERGY CODE (COMM 63) INCLUDING BUT NOT LIMITED TO BALLASTS REQUIRED FOR DUAL -LEVEL SWITCHING AND CODE- REQUIRED REDUCTION OF SINGLE -LAMP BALLASTS. LF13 - FIELD VERIFY THE EXACT LOCATIONS OF THE LIGHTING FIXTURES TO AVOID CONFLICT WITH MECHANICAL EQUIPMENT, DUCTWORK, PIPES,. AND STRUCTURAL MEMBERS, ANY CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE A /E. LF14 - IN ALL INSULATED CEILINGS, WALLS, AND WHERE RECESSED FIXTURES PENETRATE THE BUILDING ENVELOPE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING AN AIRTIGHT INSTALLATION AND PROPER CLEARANCES BETWEEN RECESSED FIXTURES AND THE INSULATION. THIS CAN BE ACCOMPLISHED BY PROPER TENTING OR BOXING -OUT AROUND RECESSED FIXTURES THAT DO NOT HAVE IC RATINGS, OR REPLACEMENT OF THOSE FIXTURES WITH EQUAL FIXTURES HAVING PROPER IC AND AIRTIGHT RATINGS. REFER TO THE ARCHITECTURAL PLANS FOR APPLICABLE AREAS. LF15 - IN ALL FIRE -RATED CEILINGS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE FIRE RATING, REFER TO ARCHITECTURAL PLANS FOR APPLICABLE AREAS. LF16 - PROVIDE OCCUPANCY SENSORS AS SHOWN ON THE PLANS. REFER TO THE SPECIFICATIONS FOR MORE INFORMATION. LF17 - PROVIDE LUTRON NOVA T SERIES DIMMERS, OR APPROVED EQUAL, FLUORESCENT AND INCANDESCENT AS APPROPRIATE, IN RATINGS NECESSARY TO ACCOMMODATE LOADS. SEE SPECIFICATIONS FOR MORE INFORMATION. LF18 - FIELD VERIFY THE EXACT LOCATION OF ALL SURFACE MOUNTED FIXTURES TO AVOID CONFLICT WITH ARCHITECTURAL FEATURES, INCLUDING PAINT /WALL COVERING SCHEMES, DECORATIVE TRIMS, ETC. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE A /E. LF19 - PROVIDE 12 EXTRA LAMPS OF EACH TYPE INDICATED IN LIGHT FIXTURE SCHEDULE AND TURN OVER TO OWNER. LF20 - FOR ALL FIXTURES EMPLOYING "T5 ", "178" AND "T12" FLUORESCENT LAMPS PROVIDE ROTATING TYPE LAMP SOCKETS. FOR ALL GRID LAY -IN TROFFERS INCLUDE INTEGRAL GRID "CUPS" FOR ATTACHING ON TO THE "TEE" BAR IN ACCORDANCE WITH N.E.C. LF21 - IN ALL PLENUM RATED CEILING CAVITIES PROVIDE PLENUM RATED TROFFERS AND OTHER. TYPES OF LIGHTING FIXTURES IF REQUIRED BY LOCAL CODE(S). LF22. - IN LOCATIONS OF LIFE SAFETY EGRESS ROUTE, WHERE ONE LIGHT FIXTURE IS EMPLOYED, 2 LAMPS AND 2 BALLAST ARE REQUIRED IN THE FIXTURE TO COMPLY TO N.E.C. ARTICLE 700.16 EMERGENCY ILLUMINATION. LF23 - FOR WALL MOUNTED FIXTURES, PROVIDE SEALANT AROUND MOUNTING PLATE TO PROTECT AGAINST MOISTURE INSIDE OF FIXTURE. LF24 - LIGHT FIXTURES SPECIFIED ESTABLISH A LEVEL OF QUALITY WHICH SHALL BE MET BY ALL FIXTURES PROVIDED. FIXTURES SHALL BE COMPARABLE IN PERFORMANCE, CONSTRUCTION, PHYSICAL APPEARANCE, FINISH AND FEATURES IN ORDER TO BE CONSIDERED EQUIVALENT. FIXTURES NOT DEEMED "EQUIVALENT" MAY NOT BE SUBMITTED AS AN "ALTERNATE" OR "SUBSTITUTE" FIXTURE TO THAT WHICH WAS SPECIFIED. DETERMINATION OF "EQUIVALENCY" SHALL BE THE RESPONSIBILITY OF A /E. THERE SHALL BE NO ADDITIONAL COST ASSOCIATED WITH REJECTION OF A FIXTURE NOT DEEMED "EQUIVALENT" BY THE A /E. EQUIVALENT FIXTURES BY THE FOLLOWING MANUFACTURERS WILL BE CONSIDERED IN LIEU OF THOSE NAMED IN LIGHTING FIXTURE SCHEDULE: a. UTHONIA, DAYBRITE b. CHLORIDE, LITHONIA c. UTHONIA, OMEGA RIC14ARD F. STELDT t ASSOCIATES, LTD. ARCI•IITECTS 0WER6NIP OF D00J'1ENT8 This docunant, and the Ideas and dftigm Incorporated herein, as an Mt wft of professional service, is the property of R►dtird R &aldt and Associates, Ltd. and 16 rot to be used N whole or In part, for any other Project without the written aYlh Intlon of Rtdird F. OwIdt and Associates, Ltd `t�isassss�t.��� v A y QI its �� 1 � {e aro '= HARWOOD ENGINEERING CONSULTANTS, LTD 7420 West State Street Milwaukee Wisconsin 53213 414.475.5554 414.475.5698 fax horwood6hecl.com HEC Project Number: 07- 1192.00 Drawn by: TSA Checked by: DHO Designed by: DHO LIGHTING FIXTURE SCHEDULE IMCONSULTANTS >� w W .� z co W W Uo z H � O =Cz tu,os.sw uumau,m m.welroxgpe � � a d CIO to LAMP DATA ko co z Drawn: Approved: LIGHTING FIXTURE B comments REVISIONS SEE DES. DESCRIPTION VOLT DEPTH TMP MTG. SURF NOTE a n Q o L0 Oz W -`to �< O z L0 QzoL0 O >- W Z L►J (f Lo V Jr I N0. �� W Q TYPE il-.-. z�� < z Q,-., U <C_Z- MFR. SERIES OPTIONS /ACCESSORIES - o z U Sheet EXIT SIGN -LED EA SINGLE FACE LED 120 SURE -LITES CX SERIES SURF VERIFY 24b EXIT SIGN -LED EB DOUBLE FACE LED 120 SURE -LITES CX SERIES VERIFY 24b 4 FLUORESCENT WRAPAROUND FA VANDAL RESISTANT 2 F32T8 120 KENALL MLRS12 SERIES 03,04,06,23 E SURF VERIFY 4 FLUORESCENT WALL MOUNT FB W/0.125" ACRYLIC LENS 2 F32T8 120 METALUX BC SERIES 01,03,06,23 E SURF VERIFY 24a 15 DIA FLUORESCENT FC SURFACE MOUNTED 2 CFI3DTT 120 KENALL RHR15 SERIES 03,06,23 E SURF VERIFY VANDAL RESISTENT SAME AS TYPE FA M3 FD W/ LAMPS 3 F32T8 120 KENALL MLRS12 SERIES 03,04,06,23 E SURF VERIFY 6 DOW LIGHT WITH RB OPAL DROP LENS 2 26WDTT 120 -1/2" HALO H271CAT 03,06,09,18 E REC VERIFY 24c WET LOCATION LISTED 2 WALL MOUNT VANITY WA 2T F14T5 120 SHAPER 600 -24 SERIES 03,06 E SURF VERIFY 24a ABBREVIATIONS AR AS REQUIRED GRD GROUND NA NOT APPLICABLE S STANDARD (HID) VAR VARIES CONC. BASE CONCRETE BASE GYP. GYPSUM BOARD PS PULSE START BALLAST SPEC SPECIAL LAS LENGTH AS SHOWN E ELECTRONIC LAS LENGTH AS SHOWN PEND PENDANT STAN STANTION EXP EXPOSED STRUCTURE LIG LAY -IN GRID REC RECESSED SURF SURFACE OPTIONS / ACCESSORIES CODE LISTING: 01. 0.125" PATTERN 12 ACRYLIC LENS 10. CUSTOM COLOR 21. QUARTZ RESTRIKE 02. HOLOPHANE 8246 LENS 11. PENDANT MOUNT 22. EMERGENCY OPERATION - 03. PAINT AFTER FABRICATION 12. SAFETY CHAIN INTEGRAL NICAD BATTERY 04. SPRING LOADED LATCHES 13. NEMA HOOK, CORD AND PLUG 23. LOCKING TYPE SOCKETS 05. FLUSH ALUMINUM DOOR FRAME 14. WIRE GUARD 24. SLOPE ADAPTER 06. ELECTRONIC BALLAST, TOTAL HARMONIC 15. EMERGENCY BALLAST 25. TWO BALLAST COVERS DISTORTION S 10% 16. TOP AND BOTTOM LENSING 26. STANDARD FINISH TO BE SELECTED BY 07. FLUORESCENT DIMMING BALLAST 17. TIME DELAY ARCHITECT 08. WHITE TRIM RING 18. WET LOCATION LABEL 27. 277/24 VOLT TRANSFORMER 09, SEMI - DIFFUSE, LOW- IRIDESCENT CLEAR 19. DAMP LOCATION CONSTRUCTION 28. LEAD- CALCIUM BATTERY ALZAK REFLECTOR 20. FURNISH WITH UNIVERSAL ARROWS AND 29. INCLUDE SELF - DIAGNOSTICS RED STENCIL FACE `t�isassss�t.��� v A y QI its �� 1 � {e aro '= HARWOOD ENGINEERING CONSULTANTS, LTD 7420 West State Street Milwaukee Wisconsin 53213 414.475.5554 414.475.5698 fax horwood6hecl.com HEC Project Number: 07- 1192.00 Drawn by: TSA Checked by: DHO Designed by: DHO O an A >� w W .� z co W W Uo z H � O =Cz UCq-° � � a d CIO to 0 eD ko co z Drawn: Approved: date comments REVISIONS Job: Date: FEB 8, 2008 J Q I- � � w zWw o' w �0 co CO X a n Q o L0 Oz W -`to �< O z L0 QzoL0 O >- W Z L►J (f Lo V Jr I Z W zo°°�n Ww J z ZCL �� W Q M wa,ao il-.-. z�� < z Q,-., U <C_Z- zQLZ �. Qry r- - o z U Sheet .E�03