Loading...
HomeMy WebLinkAbout08040129.20N -F- 4P- 4L -0 41 -FL ON HIME w w •I • SYMBOLS (NOT ALL SYMBOLS SHOWN ARE USED) FLUORESCENT LIGHTING FIXTURE - SEE SCHEDULE UNDERCABINET LIGHTING FIXTURE, WALL MOUNTED FLUORESCENT FIXTURE EMERGENCY BATTERY UNIT LIGHT FIXTURE - SURFACE MOUNTED CEILING RECESSED LIGHTING FIXTURE. CEILING SURFACE MOUNTED LIGHTING FIXTURE. WALL MOUNTED LIGHTING FIXTURE. EXIT LIGHTING FIXTURE - DIRECTION ARROWS AS REQUIRED EMERGENCY LIGHT FIXTURE WITH TWO BALLASTS -ONE FOR EMERGENCY LAMP(S), ONE FOR NORMAL LAMP(S) LOCAL SWITCH, SINGLE POLE - MOUNTED 48" AFF. LOCAL SWITCH, SINGLE POLE - MOUNTED 6" ABOVE COUNTER. LOCAL SWITCH, SINGLE POLE - 3 -WAY. LOCAL SWITCH - DOOR SWITCH LOCAL SWITCH - SWITCH STATION LOCAL SWITCH - KEY OPERATED OCCUPANCY SENSOR SWITCH - MOUNTED 48" AFF DUAL TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR DUAL TECHNOLOGY WALL - MOUNTED OCCUPANCY SENSOR COMBINATION DATA /TELEPHONE OUTLET - MOUNTED AT 18" AFF COMBINATION POWER /TELEVISION OUTLET - SEE DETAIL TELEVISION OUTLET - CLOSED CIRCUIT. ELECTRICAL DISTRIBUTION PANEL - EXISTING ELECTRICAL DISTRIBUTION PANEL - NEW GROUND Q MANUAL PULL STATION - MOUNTED AT 48" AFF. ►/ AUDIO /VISUAL SIGNAL DEVICE (HORN /STROBE) - MOUNTED AT 80" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER 75 CANDELA UNLESS NOTED OTHERWISE MANUAL PULL STATION WITH AUDIO /VISUAL SIGNAL DEVICE MOUNTED ABOVE. 75 CANDELA UNLESS NOTED OTHERWISE VISUAL SIGNAL DEVICE (STROBE) - MOUNTED AT 80" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER 75 CANDELA UNLESS NOTED OTHERWISE AUDIO /VISUAL SIGNAL DEVICE (SPEAKER /STROBE) - MOUNTED AT 80" AFF OR 6" BELOW CEILING, WHICHEVER IS LOWER 75 CANDELA UNLESS NOTED OTHERWISE SMOKE DETECTOR. Q TAMPER SWITCH. E -01 ELECTRICAL LIGHTING PLAN - SOUTHWEST UNIT EXISTING - FIRE ALARM CONTROL PANEL (FACP). E -03 EXISTING - FIRE ALARM REMOTE ANNUNCIATOR. ® MICROPHONE OUTLET - MOUNTED AT 18" AFF. ®F MICROPHONE OUTLET - MOUNTED FLUSH IN FLOOR. ® LOUDSPEAKER - FLUSH MOUNTED IN CEILING ®S LOUDSPEAKER - SURFACE MOUNTED IN CEILING ®P CEILING SPEAKER - DUAL TAP, COMBINATION PAGING AND INTERCOM. HORN LOUDSPEAKER - SURFACE MOUNTED INDICATES DETAIL NUMBER SEE DETAIL E/ INDICATES SHEET NUMBER INDICATES NOTE NUMBER E# E SEE NOTE INDICATES SHEET NUMBER dh DUPLEX RECEPTACLE - MOUNTED 18" AFF. 6 DUPLEX RECEPTACLE - MOUNTED VERTICALLY c 6" ABOVE COUNTER OR HORIZONTALLY 4" ABOVE BACKSPLASH. (ban DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE. 8TP DUPLEX RECEPTACLE - TAMPER PROOF "CHILDSAFE" TYPE. QUADRUPLEX RECEPTACLE - TWO DUPLEX RECEPTACLES UNDER A COMMON COVERPLATE. ® SPECIAL PURPOSE OUTLET - SEE SCHEDULE. 9 ELECTRICAL INFORMATION OF HVAC EQUIPMENT INDICATED ON DRAWINGS. EY DISCONNECT SWITCH. DISCONNECT SWITCH - FUSIBLE. A/E AF AFC AFF ARCH AFG AR BS BKR BFG C CAB CB cd CKT CLG CONC CID CS DS DLS DN DNLT EWC E.0 ELEV EMT ENT ER EXP EXR FX FIXT FLUOR G.C. GFI GRC GYP HOA HP HVAC HV HW ARCHITECT /ENGINEER AMP FUSE AVAILABLE FAULT CURRENT ABOVE FINISHED FLOOR ARCHITECT ABOVE FINAL GRADE AS REQUIRED AMP SWITCH JUNCTION BOX BREAKER BELOW FINAL GRADE MOUNTED 6" ABOVE COUNTER CABINET CIRCUIT BREAKER CANDELA CIRCUIT CEILING CONCRETE CONTROL PANEL COMBINATION STARTER /DISC. SWITCH DISCONNECT SWITCH DISCONNECT SWITCH DUAL LEVEL SWITCH DOWN DOWN LIGHT ELECTRIC WATER COOLER . ELECTRICAL CONTRACTOR ELEVATION OR ELEVATOR ELECTRICAL METALLIC TUBING ELECTRICAL NON - METALLIC TUBING EXISTING TO BE REMOVED EXPOSED EXISTING IN NEW LOCATION EXISTING TO REMAIN FURNISHED FIXTURE FLUORESCENT GENERAL CONTRACTOR GROUND FAULT INTERRUPTING GALVANIZED. RIGID CONDUIT GYPSUM BOARD HAND -OFF -AUTO SELECTOR SWITCH HORSEPOWER HEATING, VENTILATING, AND AIR CONDITIONING CONTRACTOR HEAVYWALL IMC IU KW LIG LOC LTG MAG MAN MC MLO MSB MTD NU NIC 0 OC ORS PU PC PEND PLBG PNL RB REC RU SS SURF SUSP SW TC TCC TYP UM VER VFD W WP XFMR INTERMEDIATE METAL CONDUIT INSTALLED INTEGRAL TO UNIT KILOWATT LAY -IN GRID LOCATION LIGHTING MAGNETIC STARTER MANUAL STARTER MECHANICAL CONTRACTOR MAIN LUGS ONLY MAIN SWITCHBOARD MOUNTED NEAR UNIT NOT IN CONTRACT OTHERS ON CENTER OVER RIDE SWITCH ON UNIT POLE PHOTOCELL PENDANT PLUMBING CONTRACTOR PANEL PUSH - BUTTON RECEPTACLE RECESSED REMOTE FROM UNIT SWITCH STATION SURFACE SUSPENDED SWITCH TIME CLOCK TEMPERATURE CONTROL CONTRACTOR TYPICAL UNIT MANUFACTURER VERIFY VARIABLE FREQUENCY DRIVE WIRED WEATHERPROOF TRANSFORMER RENOVATION /DEMOLITION NOTES: 1. ELECTRICAL DRAWINGS ARE BASED ON THE BEST INFORMATION AVAILABLE. FOR AREAS BEING REMODELED, WORK SHOWN REFLECTS INFORMATION SHOWN ON AS -BUILT PLANS AND FIELD OBSERVATION; IT IS NOT GUARANTEED 1007. ACCURATE. THIS CONTRACTOR MUST FIELD VERIFY CONDITIONS AND MAKE NECESSARY ADJUSTMENTS WITHOUT EXTRA COSTS TO THE PROJECT TO SUIT ACTUAL NEEDS. 2. THE CONTRACTOR SHALL REWIRE /REROUTE /RELOCATE, AS REQUIRED DUE TO CONSTRUCTION, ALL EXISTING CIRCUITS AND EQUIPMENT WHICH ARE TO CONTINUE IN OPERATION. 3. MAINTAIN THE INTEGRITY OF ALL SYSTEMS AFFECTED BY THE REMOVAL OR ADDITION OF ELECTRICAL DEVICES AND CONTROLS IN REMODELED AREAS. 4. ALL ELECTRICAL PANELS SHALL REMAIN IN PLACE AS IS, UNLESS INDICATED OTHERWISE. PANELS EXPOSED TO PUBLIC SHALL BE PROVIDED WITH A LOCKABLE COVER. TURN KEY(S) OVER TO OWNER. PROVIDE GROUND TERMINATE BUS IN A FLUSH JUNCTION BOX ABOVE PANEL BOARD TO ACCOMMODATE ISOLATED GROUNDING TYPE RECEPTACLES. 5. PROVIDE COMPLETE UPDATED DIRECTORIES FOR ALL PANELS AFFECTED BY CONSTRUCTION. 6. CIRCUITS INDICATED ARE INTENDED TO DENOTE WHICH DEVICES /FIXTURES ARE TO BE WIRED TO A COMMON CIRCUIT BREAKER, AND NOT ITS POSITION IN THE PANEL. UTILIZE REUEVED /SPARE CIRCUIT BREAKER MOUNTING SPACES,. PROVIDE CIRCUIT BREAKERS AS REQUIRED. REBALANCE LOADS BETWEEN PHASES (MAX. 7.5%) UPON COMPLETION OF WIRING. 7. NOT USED. 8. NEW EXIT LIGHTS SHALL BE WIRED TO THE NEAREST AVAILABLE UNSWITCH LIGHTING CIRCUIT SERVING THE AREA THAT EXIT LIGHT IS INSTALLED. 9. ALL EXISTING DEVICES WHICH ARE TO REMAIN AND ARE LOCATED ON NEW FURRED OUT WALLS SHALL BE PROVIDED WITH APPROPRIATE EXTENSION RINGS. REFER TO ARCHITECTURAL DRAWINGS FOR SPECIFIC WALLS. 10. ALL EXISTING DEVICES WHICH ARE NOT SHOWN ON THESE DRAWINGS OR DIRECTED BY A/E SHALL REMAIN IN PLACE AS IS. 11. EXISTING RECEPTACLES WHICH WOULD BE RENDERED INACCESSIBLE, DUE TO THE PLACEMENT OF NEW CASEWORK, SHALL BE RELOCATED. TO THE KICK PLATE OF THE CASEWORK, OR OTHERWISE RELOCATED SUCH THAT RECEPTACLES ARE ACCESSIBLE. 12. ALL NEW DEVICES AND COVER PLATES SHALL MATCH EXISTING UNLESS OTHERWISE DIRECTED BY A /E. 13. ELECTRICAL RACEWAYS SHALL BE CONCEALED IN CEILING CAVITY OR IN WALLS. EXPOSED RACEWAYS ARE NOT ACCEPTABLE UNLESS SPECIFICALLY INDICATED AND /OR APPROVED BY A /E. IF EXPOSED, RACEWAYS SHALL BE EXPOSED WIREMOLD TYPE, 200, 500 OR 700 AS NECESSARY TO ACCOMMODATE WIRES. 14. EXACT LOCATION OF SPECIAL PURPOSE OUTLETS SHALL BE VERIFIED IN FIELD. VERIFY SPECIFIC WIRING REQUIREMENTS WITH VENDORS' DRAWINGS /INSTRUCTION, COORDINATING ELECTRICAL WORK WITH WORK OF VENDOR AND OTHER TRADES. 15. IN ROOMS WHICH HAVE BEEN SUBDIVIDED, UNUSED EXISTING LIGHTING SWITCHES SHALL BE REMOVED AND BLANK COVER PLATES SHALL BE PROVIDED. PROPERLY TERMINATE ALL UNUSED CONDUCTOR(S) WITH WIRE NUT(S). 16. EXISTING CEILING SPEAKERS SHALL BE REMOVED PRIOR TO DEMOLITION OF EXISTING CEILINGS. SPEAKERS SHALL BE REINSTALLED IN COMPARABLE LOCATION IN NEW CEILING. CONTRACTOR SHALL DOCUMENT DEVICES PRIOR CEILING REMOVAL. 17. WALL MOUNTED SPEAKERS, FIRE ALARM DEVICES, ETC. SHALL BE RELOCATED AS NECESSARY TO ACCOMMODATE NEW CEILING HEIGHTS. 18. INCLUDE FISH WIRE IN ALL NON -POWER CONDUITS. RICHARD F. STELDT 4 A660CIATES, LTV. ARCHITECTS oUNEwiP of Dof.U'ENTS This doozod, and the (do* and dal9m incorporated herein, as an MpAw t of professional servtce, Is the property of Rtdwrd P. &AWL and Aesoctates, Ltd and is not to be wed in whole or h Pak, for any othw project without the writtae aW wIntion of Rtdvrd F. &sWt and A"mtata, Ltd. 19. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY DISCONNECTING POWER AND REMOVING THE EXISTING FIXTURES FOR REUSE. ANY . FIXTURE(S), ELECTRICAL DEVICES, NOT INDICATED TO BE REUSED SHALL BE PROPERLY DISPOSED OF AND /OR IN ACCORDANCE WITH THE SPECIFICATIONS. 20. VERIFY EXACT LOCATION OF LIGHTING FIXTURES IN THE FIELD TO AVOID CONFLICT WITH MECHANICAL EQUIPMENT, DUCT WORK, AND PIPES. 21. CONTRACTOR SHALL PROPERLY REMOVE, CLEAN, RELAMP, AND REINSTALL EXISTING FIXTURES AS DESCRIBED AND SHOWN ON PLANS. 22. IN ALL LOCATIONS WHERE RE -USE OR EXTENDING OF AN EXISTING CIRCUIT IS INDICATED ON THE PLANS, THE CONTRACTOR SHALL VERIFY THAT THE EXISTING CIRCUIT HAS ENOUGH CAPACITY TO HANDLE THE ADDITIONAL LOAD. IF REQUIRED CAPACITY DOES NOT EXIST, THE CONTRACTOR SHALL EXTEND A NEW CIRCUIT TO FEED THE NEW EQUIPMENT. NO MORE THAN 6 DUPLEX RECEPTACLES SHALL BE ON ONE .CIRCUIT. 23. PAINT ALL EXPOSED CONDUIT TO MATCH ADJACENT AREAS WHEN THE CONDUIT IS IN A FINISHED AREA. 24. REMOVE AND REINSTALL EXISTING CEILING TILE REQUIRED FOR INSTALLATION OF CONDUITS AND CABLES. COORDINATE ALL WORK WITH THE GENERAL CONTRACTOR. REPLACE ANY DAMGED TILES. 25. FIRE AND /OR SMOKE RATINGS OF WALLS, FLOORS AND CEILINGS SHALL BE MAINTAINED. IF THE INTEGRITY IS SACRIFICED THEN THE BARRIER SHALL BE REPAIRED TO ITS ORIGINAL RATING. ALL PENETRATIONS SHALL BE PROPERLY SEALED. 26. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADJUSTING AND AIMING ALL FIXTURES TO THE OPTIMUM DISTRIBUTION AND OWNER'S SATISFACTION. 27. COORDINATE CABLE TYPES AND INSTALLATIONS FOR WORK ABOVE CEILING WITH HVAC FOR PLENUM VS. NON- PLENUM RATING OF CEILING SPACE, INSTALLATION SHALL FOLLOW GUIDELINES FOR RATINGS OF CEILING CAVITY. 28. FOR ALL FLUSH FLOOR BOXES, THE CONTRACTOR SHALL TRENCH AND RUN CONDUIT TO NEAREST WALL OR COLUMN UP TO AN ACCESSIBLE LOCATION ABOVE CEILING OR PANEL BOARD AS REQUIRED, OR AS INDICATED ON DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING TRENCH TO OWNER'S SATISFACTION. 29. THE CONTRACTOR SHALL NOTE THAT THE EXISTING BUILDING WILL REMAIN IN SERVICE DURING CONSTRUCTION. AREAS OF THE BUILDING WILL BE VACATED AS REQUIRED TO FACILITATE CONSTRUCTION. PROCEED WITH THE COMPLETION OF THE WORK IN SUCH A MANNER AS TO CAUSE THE LEAST POSSIBLE INTERFERENCE WITH OWNER'S OPERATION. ALL WORK SHALL BE DONE IN A MANNER AND TIME ACCEPTABLE TO OWNER. OUTAGES AND OTHER WORK RENDERING EXISTING EQUIPMENT INOPERATIVE SHALL BE HELD TO A MINIMUM; PRIOR ARRANGEMENTS FOR EACH SHALL BE MADE WITH OWNER AND SHALL BE ACCEPTABLE AS TO TIME AND DURATION. ALL SHUTDOWNS SHALL BE COORDINATED WITH OWNER 2 WEEKS IN ADVANCE. 30. THE CONTRACTOR SHALL DO THE NECESSARY DEMOLITION WORK IN THE AFFECTED AREAS INCLUDING THE REMOVAL OF LIGHTING FIXTURES, LAMPS, WIRING, ACCESSIBLE CONDUIT, AND ELECTRICAL EQUIPMENT, IN ADDITION, PRECEDING DEMOLITION WORK, HE SHALL DE- ENERGIZE ALL CIRCUITS IN THE AFFECTED AREAS AND WHERE WIRING IS ROUTED THROUGH THESE AREAS SERVING AREAS OF THE BUILDING REMAINING IN SERVICE, PROVIDE TEMPORARY AND /OR PERMANENT WIRING AS REQUIRED. ALSO, WHERE NECESSARY TO MAINTAIN SERVICE IN OTHER AREAS, PROVIDE NECESSARY AND REQUIRED SOURCES OF POWER AND TEMPORARY WIRING. REMOVE ALL CONDUIT AND WIRING OF EQUIPMENT BEING REMOVED AND /OR ABANDONED BACK TO SOURCE, 31. VERIFY LOCATION OF MARKER BOARDS, TACK BOARDS, ARTWORK, SIGNS AND ANY OTHER WALL MOUNTED ITEMS PRIOR TO ROUGH -IN OF FIRE ALARM DEVICES AND ANY OTHER WALL MOUNTED DEVICE. DO NOT ROUGH IN BEHIND BOARDS. 32. NOT USED. 33. A/E REVIEW OF REDUNDANT SUBMITTALS FROM BACKUP, SECOND SOURCE OR REPLACEMENT SUPPLIERS /CONTRACTORS IS CONTRACTOR'S EXPENSE. 34. A/E SERVICES RELATED TO A SUBSTITUTION OR CHANGE PROPOSED BY THE CONTRACTOR ARE THE CONTRACTOR'S EXPENSE. DO NOT RELY ON ACCEPTANCE IN PREPARING BIDS. THE A/E MAY REJECT THESE WITHOUT CAUSE. SHEET INDEX EL SYMBOLS, ABBREVIATIONS AND NOTES E -01 ELECTRICAL LIGHTING PLAN - SOUTHWEST UNIT E -02 ELECTRICAL POWER AND SYSTEMS PLAN - SOUTHWEST UNIT E -03 LIGHTING FIXTURE SCHEDULE AND NOTES E -04 ELECTRICAL SPECIFICATION AND DETAILS f'V ` r V r.✓ HARWOOD �■ ENGINEERING CONSULTANTS, LTD 7420 West State Street Miiwoukee Wisconsin 53213 414.475.5554 414.475.5698 fax harwood�heci.com HEC Project Number: 07 -1 I92.OD Drawn by: TSA Checked by: DHO Designed by: DHO O tn A0 I� a Gr, W W z C/o F 0 W o O z H F o 0 L .-. 0_CQ z cc a Q l co o co co z Drawn: Approved: date comments REVISIONS Job: Date: FEB 8, 2008 I Q � � w z w LLi W H 0 i- 00 X Z N Q a n Q��,� ZOz W _moo �a O z o J U az L0 0.q_ Z z L.J _J (fi Lo >CDv) C> w -I Z W z�o0� IX w z zCL LiJ i"� IX o m: _ wQ,00 CL 2 z� t` Q U Q Z- M � � zQLo z .. Qtr- _ O z O Sheet EL