HomeMy WebLinkAbout08060046.30I MEDICAL GAS OUTLET SCHEDULE OOUTLET LOCATION QUANTITY TAG WALL CEILING 0 NO MA V N SLIDE A X WHA -2 1 1 1 1 200 1 B 1" X 1 1 1 P.D.I CERTIFIED 1 1" C X W -50 400 P.D.I CERTIFIED JAY R. SMITH 4021S (CARPET); 1 BRONZE COVER, BRONZE PLUG, GASKET SEAL. 1 D X ZURN; JOSAM; WADE; MIFAB BRADFORD WHITE; AO SMITH WALL CLEANOUT: 1 1 1 1 E X L -2 1 CP -1 CIRCULATOR PUMP 1 E7 -B 1 F X 1/6 L -3 LAVATORY - WALL HUNG, ADA, EYE WASH 1 1 1/2" 1 1 1/4" 1 1/2" 1 1/2" 34" TO RIM SK -1,5,6 SINK - ONE COMPARTMENT 1/2" 1/2" WATER HAMMER ARRESTER SCHEDULE TAG I.P.S. F.U. RATING J.R. SMITH NO. WADE NO. ZURN NO. REMARK WHA -1 3/4" 1 11 5005 W -5 100 P.D.I CERTIFIED WHA -2 1" 12 - 32 5010 W -10 200 P.D.I CERTIFIED WHA -3 1" 33 - 60 5020 W -20 300 P.D.I CERTIFIED WHA-4 1" 61 - 113 5030 W -50 400 P.D.I CERTIFIED DRAINAGE FITTING SCHEDULE MARK FIXTURE MANUFACTURER/MODEL NUMBER NO. DESCRIPTION SPECIFICATION NAME MANUFACTURER FLOOR DRAIN: JAY R. SMITH 2O05Y -A; ZURN; JOSAM; WADE; CAPACITY CAST IRON, FLASHING COLLAR, BOTTOM NO -HUB MIFAB FD -1 OUTLET. MBH OUT COMPRESSED AIR LINE STRAINER: NICKEL BRONZE, ADJUSTABLE, ROUND, FLAT 4" 2" FLOOR SINK: JAY R. SMITH 3150Y; ZURN; JOSAM; WADE; MIFAB WATER CLOSET - FLUSH VALVE, ADA CAST IRON, DEEP BODY RECEPTOR, ACID RESISTANT SANITARY WASTE (BURIED) FS -1 COATED INTERIOR SURFACE, NO -HUB BOTTOM OUTLET, INTEGRAL 4" LESS GRATE, LESS SEDIMENT BUCKET. WATER HEATER LOCHINVAR FLOOR CLEANOUT: JAY R. SMITH 4141S (TILE); 20 GPH RECOVERY CAST IRON BODY, ROUND ADJUSTABLE SECURED NICKEL JAY R. SMITH 4021S (CARPET); FCO BRONZE COVER, BRONZE PLUG, GASKET SEAL. JAY R. SMITH 4221S (CONCRETE); SET OUTLET TEMP AT 140 °F L -1 ZURN; JOSAM; WADE; MIFAB BRADFORD WHITE; AO SMITH WALL CLEANOUT: JAY R. SMITH 4710; ZURN; JOSAM; WADE; MIFAB @ 90 °F TEMP. RISE STAINLESS STEEL SHALLOW COVER WITH CENTER 1 1/2" WCO VANDAL PROOF SCREW. L -2 PLUMBING EQUIPMENT SCHEDULE UNIT ELECTRICAL DATA GAS DATA NOTES TAG SPECIFICATION NAME MANUFACTURER MODEL # WEIGHT CAPACITY V -PH -HZ HP KW MBH IN MBH OUT COMPRESSED AIR LINE INTEGRAL 4" 2" 15" TO SEAT WC -2 WATER CLOSET - FLUSH VALVE, ADA SANITARY WASTE (BURIED) 1" SANITARY VENT LINE INTEGRAL 4" WH -1 WATER HEATER LOCHINVAR LT -120KK - 20 GPH RECOVERY 208 -1 -60 NITROUS OXIDE LINE 4.5 - - SET OUTLET TEMP AT 140 °F L -1 (BACK UP) BRADFORD WHITE; AO SMITH GAS SHUT -OFF VALVE 112" @ 90 °F TEMP. RISE 1 1/4" 1 1/2" 1 1/2" SEE ARCHITECTURAL DRAWINGS L -2 LAVATORY - WALL HUNG, ADA CP -1 CIRCULATOR PUMP ARMSTRONG E7 -B - 2 GPM @ 15 FT TOTAL DYNAMIC HEAD 120 -1 -60 1/6 L -3 LAVATORY - WALL HUNG, ADA, EYE WASH - ALL BRONZE CONSTRUCTION 1/2" VENT THRU ROOF 1 1/4" 1 1/2" 1 1/2" 34" TO RIM SK -1,5,6 SINK - ONE COMPARTMENT 1/2" 1/2" CONTROLLED BY AQUASTAT 1 1/2" (140 °F HOT WATER) (TACO; GRUNDFOS) MOUNT IN COUNTERTOP SK -2,3 SINK - TWO COMPARTMENT 1/2" - 1/2" 1 1/2" 11/2" RPZ -1 BACKFLOW PREVENTER WILKINS 11/2" 975XL - 40 GPM @ 15 PSI DROP - - 1 1/2" - - AIR GAP FITTING PIPE DRAIN TO MB SK -7 (NON - POTABLE SOFT WATER) (AMES; FEBCO) - (1) 1 " (2)1/2„ INTEGRAL 4" 2" 30" TO RIM SH -1 SHOWER-ADA 1/2" 112" 2" 2" 1 1/2" 42" (VALVE), 60" (HAND SPRAY), 78" (HEAD) MB -1 MOP BASIN 3/4" PROVIDE AIR FILTER WITH BYPASS AC -1 AIR COMPRESSOR 3" 3" 1 1/2" 2 CFM, SINGLE STAGE, OIL -LESS, 100 PSI MAX. 115 -1 -60 HOSE STATION 112" 1/2" 1/2" ON DISCHARGE AIR LINE - - 48" (MIXING VALVE), 60 "(VACUUM BREAKER WBA WALL SUPPLY / DRAIN BOX 1/2" 1/2" 2" (40 MICRON MAXIMUM) PLUMBING FIXTURE ROUGH -IN SCHEDULE TAG FIXTURE DESCRIPTION HW TW CW CSW TRAP W V MOUNTING HEIGHT WC -1 WATER CLOSET - FLUSH VALVE 140'---- HOT WATER RETURN (140° F) LINE 1" COMPRESSED AIR LINE INTEGRAL 4" 2" 15" TO SEAT WC -2 WATER CLOSET - FLUSH VALVE, ADA SANITARY WASTE (BURIED) 1" SANITARY VENT LINE INTEGRAL 4" 2" 17" TO SEAT UR -1 URINAL - FLUSH VALVE, ADA V VACUUM LINE 3/4" NITROUS OXIDE LINE INTEGRAL 2" 1 1/2" 17" TO RIM L -1 LAVATORY - INTEGRAL BOWL AND COUNTERTOP 1/2" GAS SHUT -OFF VALVE 112" BALANCE VALVE 1 1/4" 1 1/2" 1 1/2" SEE ARCHITECTURAL DRAWINGS L -2 LAVATORY - WALL HUNG, ADA 1/2" ELBOW DOWN 1/2" TEE UP 1 1/4" 1 1 /2" 1 1/2" 34" TO RIM L -3 LAVATORY - WALL HUNG, ADA, EYE WASH 112" 112" 1/2" VENT THRU ROOF 1 1/4" 1 1/2" 1 1/2" 34" TO RIM SK -1,5,6 SINK - ONE COMPARTMENT 1/2" 1/2" 1 1/2" 1 1/2" 1 1/2" MOUNT IN COUNTERTOP SK -2,3 SINK - TWO COMPARTMENT 1/2" - 1/2" 1 1/2" 11/2" 1 1/2" MOUNT IN COUNTERTOP SKA SINK - THREE COMPARTMENT 1/2" - 1/2" 1 1/2" 1 1/2" 1 1/2" MOUNT IN COUNTERTOP SK -7 HOPPER SINK - FLUSH VALVE, FAUCET, BEDPAN WASHER 1/2" - (1) 1 " (2)1/2„ INTEGRAL 4" 2" 30" TO RIM SH -1 SHOWER-ADA 1/2" 112" 2" 2" 1 1/2" 42" (VALVE), 60" (HAND SPRAY), 78" (HEAD) MB -1 MOP BASIN 3/4" - 3/4" 3" 3" 1 1/2" 36" TO FAUCET HS -1 HOSE STATION 112" 1/2" 1/2" - - - 48" (MIXING VALVE), 60 "(VACUUM BREAKER WBA WALL SUPPLY / DRAIN BOX 1/2" 1/2" 2" 2" 1 1/2" 38" TO DRAIN INLET FIRE PROTECTION GENERAL NOTES: 1. SPRINKLER SYSTEM SHALL BE HYDRAULICALLY CALCULATED, FULLY SUPERVISED, AND INSTALLED ACCORDING TO NFPA 13. 2. CONTRACTOR SHALL OBTAIN FLOW TEST DATA FROM UTILITY PRIOR TO DESIGN AND HYDRAULIC CALCULATION OF SPRINKLER SYSTEM. 3. ALL SPRINKLER SYSTEM ITEMS REQUIRED BY CODE SHALL BE THE RESPONSIBLITY OF THIS CONTRACTOR WHETHER SHOWN ON THE DRAWINGS AND SPECIFICATIONS OR NOT. 4. PIPE ROUTINGS INDICATED ON DRAWINGS ARE DIAGRAMMATIC AND ARE A SUGGESTED METHOD FOR DESIGN. CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL COORDINATION, LAYOUT, CODE COMPLIANCE, AND DESIGN. 5. PROVIDE UPRIGHT HEADS IN UNFINISHED SPACES (I.E. THOSE WITH EXPOSED STRUCTURE), SEMI - RECESSED HEADS IN HARD CEILINGS (I.E. THOSE WITH DRYWALL), SEMI - RECESSED HEADS, CHROME OR WHITE, IN CENTER OF LAY -IN CEILING, OR AS INDICATED ON DRWGS. OTHERWISE ON THE DRAWINGS. 6. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION OF CEILING MOUNTED ITEMS. 7. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE TO ATTEND ALL BUILDING WALK- THROUGH'S (AFTER BUILDING IS OCCUPIED AND PRIOR TO THE END OF THE 1 YEAR WARRANTY PERIOD) BY THE BUILDING FIRE MARSHAL AND IS RESPONSIBLE FOR MAKING ANY MODIFICATIONS TO THE SYSTEM REQUIRED AS A RESULT OF THIS BUILDING INSPECTION. B. FIRE PROTECTION SPRINKLER PIPE AND FITTINGS: 2" NPS AND SMALLER TO BE SCHEDULE 40 2 1/2" NPS AND LARGER TO BE SCHEDULE 10 9. REFER TO DIVISION 15 SPECIFICATION SECTIONS FOR OTHER REQUIREMENTS. SYMBOLS AND ABBREVIATIONS COLD WATER LINE CSW COLD SOFT WATER LINE —7�- CSW NON - POTABLE COLD SOFT WATER LINE - - HOT WATER LINE - - - HOT WATER RETURN LINE 140 ° -- HOT WATER (140° F) LINE 140'---- HOT WATER RETURN (140° F) LINE A COMPRESSED AIR LINE I STORM WATER (SUSPENDED) / STORM WATER (BURIED) ' I SANITARY WASTE (SUSPENDED) SANITARY WASTE (BURIED) ------- - - - - -- SANITARY VENT LINE D DRAIN LINE N NITROGEN LINE O OXYGEN LINE V VACUUM LINE NO NITROUS OXIDE LINE MA MEDICAL AIR LINE m BACKFLOW PREVENTER WATER SHUT -OFF VALVE GAS SHUT -OFF VALVE - -IOF-- BALANCE VALVE --- -f�� -- CHECK VALVE TEMP/PRESSURE RELIEF VALVE O-- -T ELBOW UP C ELBOW DOWN TEE UP TEE DOWN —� END CAP _HIS— UNION EX. EXISTING VTR VENT THRU ROOF PLUMBING GENERAL NOTES: (APPLY TO ALL PLUMBING DRAWINGS) 1. P.C. SHALL FIELD VERIFY EXISTING PIPE AND EQUIPMENT SIZES, LOCATIONS, ELEVATIONS, MATERIALS, ETC. BEFORE BIDDING OR BEGINNING WORK. 2. P.C. SHALL COORDINATE WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION. 3. P.C. SHALL COORDINATE SHUT DOWN OF ANY MECHANICAL SYSTEM WITH THE OWNER AND ANY AUTHORITY HAVING JURISDICTION. 4. PROVIDE TEMPORARY CAPS FOR ALL SERVICES AS REQUIRED SO EXISTING SYSTEMS WILL REMAIN OPERATIONAL. 5. P.C. SHALL PROTECT ALL EXISTING OWNER FACILITIES DURING CONSTRUCTION. ANY FACILITIES DAMAGED OR DISCONNECTED BY CONTRACTOR OPERATIONS SHALL BE FULLY RESTORED TO PREVIOUS OPERATING AND APPEARANCE CONDITION. 6. REPAIR OR REPLACE PIPE INSULATION DAMAGED DURING DEMOLITION OR RENOVATION WORK TO MATCH ORIGINAL CONDITION. 7. P.C. SHALL COORDINATE WITH APPROPRIATE TRADE TO CUT AND PATCH FINISHED AREAS AS REQUIRED, UNLESS OTHERWISE NOTED ON DOCUMENTS. 8. P.C. SHALL REMOVE AND REPLACE CEILINGS, LIGHT FIXTURES, ETC. IN EXISTING BUILDING AS REQUIRED TO PERFORM DEMOLITION AND RENOVATION WORK. AFTER WORK IS COMPLETE, DAMAGED ITEMS SHALL BE REPAIRED TO ORIGINAL CONDITION OR REPLACED. 9. P.C. WILL REMOVE ALL PIPING, VALVES, ETC. MADE OBSOLETE AS A RESULT OF NEW CONSTRUCTION. 10. THOROUGHLY REVIEW ALL DRAWINGS PRIOR TO ANY DEMOLITION WORK. ANY DEVICES REMOVED ACCIDENTALLY WILL BE REPLACED AT NO ADDITIONAL COST TO OWNER. 11. DISPOSAL OF DEMOLISHED MATERIALS SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS. 12. P.C. SHALL PROVIDE SLEEVES FOR ALL PIPING THAT PENETRATES FULL HEIGHT WALLS, WHETHER SHOWN OR NOT. 13. INSULATE ALL PLASTIC PIPING IN RETURN AIR PLENUMS TO MAINTAIN 2%0 FIRE SMOKE RATING AND AS DIRECTED IN SPECIFICATIONS. 14. ALL PLUMBING SYSTEMS TO BE INSTALLED TO MEET THE REQUIREMENTS OF INDIANA PLUMBING CODE, 1999 (UNIFORM PLUMBING CODE, 1997 WITH INDIANAAMMENDMENTS). 15. PIPE ROUTINGS INDICATED ON DRAWINGS ARE DIAGRAMMATIC AND ARE A SUGGESTED METHOD OF DESIGN. P.C. SHALL BE RESPONSIBLE FOR FINAL COORDINATION, LAYOUT, CODE COMPLIANCE AND DESIGN. ECTOR CONSULTING LLC Mechanical & Electrical Engineering 212 West 10th Street, Suite x395 Indianapolis, Indiana 46202 ph. 317632.4444 fax 317632.4960 AGE 'T' FL AI (2ND FLOOR - EAST) SCALE: NONE Ilk W) NORTH FL ENAAE: — PROJ. NOc 08-018 DRAWN BY- CKC PLOT SCALE: AS NOTED DATE: 04MOS Q W zMM W I4 Q-4 z 0 Q w ~z W � �wz o� W �z Q W W �W a U7 �z° �aW w�� 0 R. No. - 10200105 STATE OF S&D I AN.��s4���� %�NA�,,�O0\\��� TGS ARCHITECTS, INC. 6535 N. FERCXXM onlE T NDIANAPOLJB, IUD ,1A 46220 PHONE (M 255 -3475 FAX/MODM (3D) 256 -7356 E-MAL TC919ARCHBAAOLCOM SHEET NO. P6.01