Loading...
HomeMy WebLinkAboutWalter P. Moore - Additional Structural Engineering Services - $55,440WALTER P MOOR September 20, 2009 Mr. Les Olds Carmel Redevelopment Commission 30 W. Main Street, Suite 220 Carmel, Indiana 46032 Re: Proposal for Additional Structural Engineering Services Carmel Regional Performing Arts Center Limited Peer Review Walter P Moore Proposal No. P09 -1303B Dear Mr. Olds: We are pleased to submit this proposal to perform additional engineering services for the referenced project. This work will be performed as an Additional Service under provisions of our agreement between the Carmel Redevelopment Commission and Walter P. Moore and Associates, Inc. dated June 30, 2009. Scope of Project Perform a limited peer review of select elements of the structural design, with particular focus on primary element connection designs, as summarized in the attached scope document. Scope of Services The primary elements of the peer review include the following: 1. Review the design criteria (design live loads, wind and seismic loads, beam deflection criteria, etc.) for the structure. 2. Review the General Notes and structural steel sections of the specifications. 3. Perform a structural check on selected structural steel elements as outlined in the scope document. 4. Perform a structural check on selected steel connection designs as outlined in the scope document. 5. Prepare a written report summarizing the items reviewed and the results of the review. We understand that these services will be provided in similar character and format as the Basic Services for the Project, and that the relationship between Engineer and Client will be the same. Limit of Liability The responsibility for the structural design will remain with the Engineer of Record. By performance of these services, the Structural Peer Reviewer shall not bear responsibility for the adequacy, accuracy, or completeness of the structural design or documentation. 1645 WOODALL RODGERS FREEWAY SUITE 1650 DALLAS, IE<AS 75201 2230 PHONE 214 760 6200 FA, 21d1 710 63013 HOUSr011 DALLAS TAMP= AIL'Nr4 0 5LA1100 15 15A5 61'': = uSrli1 LOS - NSELE5 Ll 5 VE 1. ILIEPP:,,IOCRE 70'.1 Mr. Les Olds Carmel Redevelopment Commission September 20, 2009 Page 2 of 2 Client - Supplied Information The client shall notify the Structural Engineer of Record in writing of the fact that Walter P. Moore will be conducting a limited structural peer review. In order for us to continue with the work toward accomplishment of the project schedule, we request a copy of this agreement, executed. Fee We propose to provide the indicated additional scope of work on a time and expense basis in accordance with the terms in Schedule A2 of the referenced agreement, with a not -to- exceed fee of $55,440.00. Our fee for these Additional Services does not include sales tax or reimbursable expenses, as applicable. We assume that miscellaneous out -of- pocket expenses related to these additional services will be reimbursed as agreed in the master agreement. Schedule The project schedule has required us to proceed with these Additional Services based on verbal authorization, however, we would appreciate receiving a signed copy of this letter agreement at your earliest convenience. We will incorporate it as an attachment rider to our prior agreement with you. We anticipate that this scope of work will be completed in approximately three weeks. We very much appreciate the opportunity to continue working with you on this project and look forward to its successful completion. Very truly yours, WALTER P. MOORE AND ASSOCIATES, INC. David A. Platten, Texas P.E. 55021 Senior Principal Accepted this Company: By: Title: Attachment: Limited Peer Review Scope Document / day of CR. C 0 C , 2009 cc: Mr. Brandon Bogan, CSO Architects Mr. Mark Holland, Walter P. Moore Mr. Dilip Choudhuri, Walter P. Moore Carmel Regional Performing Arts Center Limited Peer Review Scope Task General Notes and Structural Steel Typical Details and Specifications Cursory review Hour Budget Cost Budget 8 $ 1,440.00 Lateral Framing System 0 $ General review of load paths, diaphrams, drag struts 52.00 Foundation Plan Review 1 t0 4 main cruciform columns /footing, including connections /shop drawing 24 $ 4,320.00 S2.01 Plenum and MEP Grillage Framing Plan 0 $ None 52.02 Orchestra Low /High Framing Plan Review 6 to 8 typical composite beams Cursory review of other composite beams S2.03 Box Tier Framing Plan Review typical section 5/S7.01, including typical member connections /shop drawings S2.04 Balcony Low Framing Plan Review typical section 5/57.01, including typical member connections /shop drawings S2.05 Balcony High Framing Plan Review typical section 5/S7.01, including typical member connections /shop drawings 0 $ 8 $ 1,440.00 8 $ 1,440.00 8 $ 1,440.00 c' S2.06 Tech Attic Low Framing Plan Review corner dome framing, including connections /shop drawings 52.07 Tech Attic Intermediate Framing Plan Review dome column transfer girders (16), including connections /shop drawings Review main trusses, including connections /shop drawings Trusses T1A, T1B, T2 (2), T3, T4 S2.08 Tech Attic High Framing Plan Review details of sloped roof framing /precast panels, including connections /shop drawings Main trusses same as S2.07 (top chord of trusses at this elevation) Bracing up to dome (mostly complete under current scope) Review 4 each W40 beams spanning approx 65 feet, including connections /shop drawings S2.09 Upper Roof Framing Plan Current scope S2.10 Equipment Pit Foundation & Framing Plans None S7 Series - Steel Sections and Details Cursory review, some detailed review Prepare final report Totals 24 $ 4,320.00 120 $ 21,600.00 60 $ 10,800.00 0 $ 0 $ 24 $ 4,320.00 24 $ 4,320.00 308 $ 55,440.00 <4