Loading...
HomeMy WebLinkAbout07020009 Civil Construction Plans Rcv. 2/6/2007 DOCS7i L a ko M N M M O O N N N 0 9 cm r V) 0 U 0 0 i rn 0 rn N Ln LE i LOCATION MAP (N.T.S.) ikinc,v SHT. DESCRIPTION a COVER SHEET C100 TOPOGRAPHICAL SURVEY C200 -C201 SITE DEVELOPMENT PLAN /PROPOSED GRADING PLAN C300 -C302 EROSION CONTROL PLAN & SPECIFICATIONS C400 -C409 STREET PLAN & PROFILES /ENTRANCE DETAIL /INTERSECTION DETAILS/ PAVEMENT WIDENING PLAN /TRAFFIC CONTROL PLAN/ TRAFFIC MAINTENANCE PLAN /STRIPING PLAN /PAVING POLICY g SANITARY SEWER PLAN & PROFILES C600 -C601 STORM SEWER PLAN & PROFILES C700 WATER PLAN /WATER SPECIFICATIONS C800 -C803 CONSTRUCTION DETAILS SANITARY STORM STREET HANDICAPPED RAMPS L -1, L -2, L -3 LANDSCAPE PLANS i LOCATION MAP (N.T.S.) ikinc,v SHT. DESCRIPTION C001 COVER SHEET C100 TOPOGRAPHICAL SURVEY C200 -C201 SITE DEVELOPMENT PLAN /PROPOSED GRADING PLAN C300 -C302 EROSION CONTROL PLAN & SPECIFICATIONS C400 -C409 STREET PLAN & PROFILES /ENTRANCE DETAIL /INTERSECTION DETAILS/ PAVEMENT WIDENING PLAN /TRAFFIC CONTROL PLAN/ TRAFFIC MAINTENANCE PLAN /STRIPING PLAN /PAVING POLICY C500 -0502 SANITARY SEWER PLAN & PROFILES C600 -C601 STORM SEWER PLAN & PROFILES C700 WATER PLAN /WATER SPECIFICATIONS C800 -C803 CONSTRUCTION DETAILS SANITARY STORM STREET HANDICAPPED RAMPS L -1, L -2, L -3 LANDSCAPE PLANS REVISIONS SHT. DESCRIPTION ■ Developed RDJ LAND 510 FOX CARMEL, b y: DEVELOPMENT, LANE INDIANA 46032 PHONE # (317) - 848 -2830 FAX # (317) - 896 -1077 CONTACT PERSON: CHRIS WHITE ED LLC SCALE: 1 " = 100' 0 fly s 0 CA 146TH STRg ramil"I Iowa t -+. • _ '� SOILS MAP (N. T. S.) 6�9 7t/):Z 0 6- t_!�q 34 LOTS 20.442 AC. KEIL DRIVE SMICKLE LANE SMALLSTIC CIRCLE DESIGN DATA 1.66 LOTS /ACRE 1366.69 L.F. 712.00 L.F. 408.33 L.F. SPEED LIMIT: 25 M.P.H. PLANS PREPARED BY: STOEPPELWERTH &ASSOCIATES, INC. CONSULTING ENGINEERS &LAND SURVEYORS 7965 E. 106TH STREET FISHERS, INDIANA 46038 PHONE: (317)- 849 -5935 FAX: (317)- 849 -5942 PANS CERTIFIED BY: 2/6/07 JAMES 0. RINEHART IV DATE PROFESSIONAL ENGINEER N0. 10200495 " "" Q� � '�1STE '•• � '� L No. 10200495 =. STATE OF ' is '••.......... -• �. 41 ** S /0NAL '',111►1nIIII0 `� 50 0 25 50 1 INCH = 50 FT. t7. EXISTING POWER POLE TO BE RELOCATED h0... T. /'S O tK tK y MAIL BOX TO BE RELOCATED- �h��'`�'•� 60050} T. P0 Q P �O F G / / TO BEE ie? G1 X E. T. - ELECT. TRANSFORMER FLOW LINE : } • ,:- E.P. ELECT. PEDESTAL= r eEC BURIED ELECTRIC LINE j E. M0 ELECT. METER as E OVERHEAD ELECTRIC LINES r-I GUY WIRE BENCHMARK HISTORY: � .:l a, BURIED CABLE T.V. LINE ELEVATIONS BASED UPON THE BENCHMARK INFORMATION PROVIDED t s - TELEPHONE PEDESTAL BY THE SCHNEIDER CORPORATION CABLE T.V. LINE :j FOR THE EARLHAM PROPERTY, � �, TSC PROJECT NUMBER 5271.002. RAN A CLOSED LOOP FROM THEIR o � TELEPHONE MANHOLE TBM 2 AROUND THE SITE. K ?+Y� - -- -� -- I ii BURIED TELEPHONE LINE • ,___._____m_.___....__ GAS VALVE JRL FIELD BOOK 428, PAGES 118 -125 o ___.._���_ TELEPHONE LINE p REFERENCE BENCHMARK (TSC PROJECT NUMBER 5271.002): ^o ________.__. ,y , �__..__. __ WATER LINE C.O. CLEAN 0 U T A STANDARD USGS DISK IN CONCRETE STAMPED "95 RHP 752 1951" l fi __.,_ -�__ J___ WATER METER AT THE NORTHWEST CORNER OF 1 1.0 46TH STREET AND NORFOLK AND -- --- AS LINE WESTERN RAILROAD 18.5 FEET NORTH OF THE CENTERLINE OF N ,%. 146TH STREET. S E WE R LINE; MANHOLE ELEVATION: AN T STORM SEWER LINE; MANHOLE, 751.46' . (NGVD 1929 -� CURB INLET, FLAT INLET & ENDSECTION o M.B. MAILBOX TBM 2 (TSC PROJECT NUMBER 5271.002): FENCE LINE M•C.S.R. MARION COUNTY SURVEYOR'S RECORD TOP OF THE WEST ANCHOR BOLT ON METAL TRAFFIC POLE, SW. P.W.P. QUADRANT OF 146TH STREET AND RIVER ROAD. w o POWER POLES PK NAIL SET ELEVATION: 0 LIGHT POLE 760.79' (NGVD 1929) n- ® CAPPED REBAR STAMPED S & A TEMPORARY BENCHMARKS: O (S&A FIRM # 0008) SET � ' TBM 1 U .0-10 1 TREES TO A BRONZE DISC SET IN THE EASTER °' BE REMOVED N HEADWALL OF A CULVERT, 2.5 r FEET SOUTH OF THE NORTH END OF HEADWALL, � � ALL, SAID CULVERT IS ALONG RIVER ROAD AND 1100. FEET + NORTHEAST OF THE ENTRANCE TO PRAIRIE TRACT ELEMENTARY SCHOOL. DISC STAMPED rn "HAM 25 1964" Ln N ELEVATION: V) 749.52 (NGVD 1929) r x ..6p( n n 5414tiC)�' � A A TBM 2 A COPPERWELD AT THE RADIUS POINT OF ARCADIAN COURT. 771.54' (NGVD 1929) ELEVATION: TBM 3 A RAILROAD SPIKE SET 1 FOOT UP ON THE SOUTH SIDE OF POWER POLE NUMBER HM 14261, 20 FEET SOUTH OF SOUTH CURB OF 146TH STREET, 1150 FEET + EAST OF CHERRY TREE ROAD. 785.49' (NGVD 1929) ELEVATION: TBM 4 A RAILROAD SPIKE SET 1 FOOT UP ON THE SOUTH SIDE OF POWER POLE NUMBER HM 14273, 20 FEET SOUTH OF SOUTH CURB OF 146TH STREET, 630 FEET + WEST OF GREYLAN PLACE. 759.73' (NGVD -1929) ELEVATION: TBM 5 A COPPERWELD AT THE CENTERLINE INTERSECTION OF SETTLER'S RIDGE AND STAGHORN COURT. 757.78' (NGVD 1929) ELEVATION: t °O x ,/ x TBM 6 A COPPERWELD AT THE CENTERLINE INTERSECTION OF SETTLER'S RIDGE AND PLANTATION LANE. ELEVATION: 773.87' (NGVD 1929) TBM 7 A COPPERWELD AT THE RADIUS POINT OF PECOS COURT. 770.76' (NGVD 1929) ELEVATION: TBM 8 A COPPERWELD AT THE CENTERLINE INTERSECTION OF CHERRY TREE ROAD AND KLINGENSMITH BLVD. 773.68' (NGVD 1929) ELEVATION: O�h a _ - l i� Y s fC S (b ID r A t . s >_I m V 1 z (D n '_ V ) > W Q 0 O• R I NEy �. NIN Cj1ST i No. - 10200495 i -o • STATE OF : �♦ VDIMP- ONAL '���J�11111111111,` r W W M Ctf � DEBRIS FROM o: SHALL BE 0 OZ THE SITE. Of 0 z — o J Q Li U 0< Q ow U I � WU> 0 Q > J F— Cif Ln O •N z _ W W > 0 Z�(Y� � I r ) V / Q Q ' ) �/ �( ^� W \ O z p N 0') Z_ � §f-m0% 00 0 C:) Q W C�WJO (n Q >- I- Q0 LL. 4WZW0! — F — > 0 =WO✓1) W X Ld F— cr 0 cn otf 48 U V � DEBRIS FROM DEMOLITION SHALL BE REMOVED FROM THE SITE. — o J Q Li U W � I � Q W > Ln O •N O W Ln N Cl) Ln I-- � I I O 0') O 00 C:) Q z N-) Q0 V) _j — `- I X Q 48 Q� c a LL_ Ck3 ctf W +� Ln r� O 00 W W Ln Z _Lf � I Q L_ W 1 W z' Cfl O _ r, T_ _ f -- U -+ o 0 r� W _z w J Ln CO c: 0 W (or) Q Z O C) U NOTE: ALL DEBRIS FROM DEMOLITION SHALL BE REMOVED FROM THE SITE. NOTE.- ALL TREE REMOVAL ON -SITE TO BE DETERMINED BY DEVELOPER. 9,0% nvLc r Muct- r ,S;q YS "DIG SAFEL Y" /T'S THE LAW" CALL 2 WORKING DAYS BEFORE YOU DIG 1 -800- 382 -5544 CALL TOLL FREE PER INDIANA STATE CAW /C8 -7 -26. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE rW0 (2) WORKING DAYS BEFORE COMMENCING WORK. CAUTION LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & marks made upon the ground by others. ) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISI TING UNDERGROUND UTIL II TIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. Q z Q 0 z z 0 U z 0 Q I LLJ Q U DRAWN BY: CHECKED BY: AAA /KRG BKR SHEET N0. S &A JOB NO. 52790S1 i W w � O J Q Li U W � I � Q ry (.D O W = O I-- Q z Q 0 z z 0 U z 0 Q I LLJ Q U DRAWN BY: CHECKED BY: AAA /KRG BKR SHEET N0. S &A JOB NO. 52790S1 i J r-f L r� CL in 0 T 0 N to N 0 M J 0) w V) a 0 17 0 U rn U) rn N i " 1 f' z� i <'r 1 3 J, 1 J r r\ i i M OD �- � O Z 0 : Q ~Q O W 0 W Q W O � 0, z w O 0 }- > Z Q f)f (n < U) Z z � O < �~m� < UJ I orf . (nQ�� 0 w z w of af — > 0 �a_ Cof a_ =w0�Dw t — W- Ovnaf M V Z '0 V J / W��/ L.i_ 1 SQ L W 0 %%% p_ R I NE& �` e,� •`� Q� ' G,ISTER - : r - No. • r 1020.0495 -o STATE OF %�S/6NAL ����•`�• 0 CO N U Z ' ^w V J U O V) Cn Q C;d J� W W O (n 0 W F- CC Ld U V) z W w o � O 0 (00 < W > ::D V) Ln (D N O 0-j d- I CY) ­1j_ 00 z Q z Q) X d OO N V J CD Ln 00 W W 0') In CD c- 0 Z w o �- o z ° w L 0 a_ z 0 U rA. -, FAw `,ei h r-10 61 FLOW LINE "`.... , , ., ... � � . , � .,.,.. __ m o _ NOTE: ALL DEBRIS FROM W E.P. ELECT. PEDESTAL DEMOLITION BEC BURIED ELECTRIC LINE E M BENCHMARK HISTORY: TBM 2 b TBM 6 SHALL BE REMOVED FROM THE SITE. ELECT. METER E OVERHEAD ELECTRIC LINES ELEVATIONS BASED UPON THE BENCHMARK INFORMATION PROVIDED BY THE SCHNEIDER CORPORATION FOR THE EARLHAM PROPERTY, A COPPERWELD AT THE RADIUS POINT OF ARCADIAN COURT. A COPPERWELD AT THE CENTERLINE INTERSECTION OF SETTLER'S - GUY WIRE TSC PROJECT NUMBER 5271.002. RAN A CLOSED LOOP FROM THEIR RIDGE AND PLANTATION LANE. BURIED CABLE T. V. LINE TBM 2 AROUND THE SITE. ELEVATION: 771.54' (NGVD 1929) NOTE: ALL TREE REMOVAL ON-SITE - '� - -,: TELEPHONE PEDESTAL ELEVATION: -., _____..___ CABLE T.V. LINE j,; JRL FIELD BOOK 428, PAGES 118 -125 773.87' (NGVD 1929) f ` -- TBM 3 TO BE DETERMINED BY DEVELOPER. TELEPHONE MANHOLE ' REFERENCE BENCHMARK (TSC PROJECT NUMBER 5271.002): TBM 7 BURIED TELEPHONE LINE �.r r_:- ,f- _.__._____.____ A RAILROAD SPIKE SET 1 FOOT UP ON THE SOUTH SIDE OF POWER == {-y GAS VALVE �> POLE NUMBER HM 14261 20 FEET SOUTH OF SOUTH CURB OF �� = A STANDARD USGS DISK IN CONCRETE STAMPED 95 RHP 752 1951 A COPPERWELD AT THE RADIUS POINT OF PECOS COURT. TELEPHONE LINE AT THE NORTHWEST CORNER OF 146TH STREET AND NORFOLK AND 146TH STREET, 1150 FEET ± EAST OF CHERRY TREE ROAD. CD C.O. CLEAN OU T WESTERN RAILROAD, 18.5 FEET NORTH OF THE CENTERLINE OF ELEVATION: HOLEY MOLEY SAYS W -- - - - - - -- WATER LINE 146TH STREET. ELEVATION: 770.76' (NGVD 1929) m zv z, 785.49' (NGVD 1929) DIG SAFEL YWATER METER �. GAS LINE TBM 4 ELEVATION: E VA TI 0 N : TBM 8 (� 751.46 (NGVD 1929) 0 ' A RAILROAD SPIKE SET 1 FOOT UP ON THE SOUTH SIDE OF POWER s SANITARY SEWER LINE; MANHOLE WATER VALVE A COPPERWELD AT THE CENTERLINE INTERSECTION OF CHERRY TREE I TB M ROAD AN 2 (TSC PROJECT NUMBER 5271.002): D KL NGENSMITH BLVD. CAUTION �-- `=S POLE NUMBER HM 14273, 20 FEET SOUTH OF SOUTH CURB OF FIRE HYDRANT STORM SEWER LINE; MANHOLE, f 146TH STREET, 630 FEET + WEST OF GREYLAN PLACE. TOP OF THE WEST ANCHOR BOLT ON METAL TRAFFIC POLE, SW. - ELEVATION: � _ LOCATION OF ALL EX /STING UNDERGROUND CURB INLET, FLAT INLET & EN DSECTI ON M.B. MAILBOX QUADRANT OF 146TH STREET AND RIVER ROAD. 773.68' (NGVD 1929) b UTILITIES SHOWN ON THIS PLAN ARE BASED ELEVATION. , not limited to, manho %s inlets valves & UPON ABOVE GROUND EVIDENCE. including, but FENCE LINE ELEVATION: 759.73' (NGVD 1929} 760.79 NGVD 1929 - marks made upon the ground by others.) AND M.C.S.R. MARION COUNTY SURVEYORS RECORD � W P.W.P. ( ) TBM 5 ARE SPECULATIVE IN NATURE. THERE MAY ALSO 0 POWER POLES O PK NAIL SET S & A TEMPORARY BENCHMARKS: BE OTHER EXISITING UNDERGROUND UTILIITIES A COPPERWELD AT THE CENTERLINE INTERSECTION OF SETTLER'S FOR WHICH THERE IS NO ABOVE GROUND Q LIGHT POLE TBM 1 RIDGE AND STAGHORN COURT. EVID04CB OR FOR WJIIC�f NO ABOVE GROUND CAPPED REBAR STAMPED � � � EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS 0 7TS THE LA W OF SAID EXISTING UNDERGROUND UTILITIES DRAWN BY: CHECKED BY: (S&A FIRM # 0008) SET A BRONZE DISC SET IN THE EASTERN HEADWALL OF A CULVERT, 2.5 ELEVATION: CALL 2 WORKING DAYS BEFORE YOU DIG SHOULD BE VERIFIED BY THE CONTRACTOR AAA /KRG, B KR FEET SOUTH OF THE NORTH END OF HEADWALL, SAID CULVERT IS 757.78 (NGVD 1929) PRIOR TO ANY AND ALL CONSTRUCTION. r�~r ALONG RIVER ROAD AND 1100 FEET + NORTHEAST OF THE 1800-382-5544 SHEET No. ENTRANCE TO PRAIRIE TRACT ELEMENTARY SCHOOL. DISC STAMPED CALL TOLL FREE TREES TO BE REMOVED "HAM 25 1964" PER INDIANA STATE LAW IC8 -1 -26. { IT IS AGAINST THE LAW TO EXCAVATE ELEVATION: WITHOUT NOTIFYING THE UNDERGROUND C 10 1 LOCATION SERVICE TWO (2) WORKING S & A JOB N0. 749.52' (NGVD 19 2 9) DAYS BEFORE COMMENCING WORK. 5279051 z W w o � O z o (00 < FLOW LINE "`.... , , ., ... � � . , � .,.,.. __ m o _ NOTE: ALL DEBRIS FROM W E.P. ELECT. PEDESTAL DEMOLITION BEC BURIED ELECTRIC LINE E M BENCHMARK HISTORY: TBM 2 b TBM 6 SHALL BE REMOVED FROM THE SITE. ELECT. METER E OVERHEAD ELECTRIC LINES ELEVATIONS BASED UPON THE BENCHMARK INFORMATION PROVIDED BY THE SCHNEIDER CORPORATION FOR THE EARLHAM PROPERTY, A COPPERWELD AT THE RADIUS POINT OF ARCADIAN COURT. A COPPERWELD AT THE CENTERLINE INTERSECTION OF SETTLER'S - GUY WIRE TSC PROJECT NUMBER 5271.002. RAN A CLOSED LOOP FROM THEIR RIDGE AND PLANTATION LANE. BURIED CABLE T. V. LINE TBM 2 AROUND THE SITE. ELEVATION: 771.54' (NGVD 1929) NOTE: ALL TREE REMOVAL ON-SITE - '� - -,: TELEPHONE PEDESTAL ELEVATION: -., _____..___ CABLE T.V. LINE j,; JRL FIELD BOOK 428, PAGES 118 -125 773.87' (NGVD 1929) f ` -- TBM 3 TO BE DETERMINED BY DEVELOPER. TELEPHONE MANHOLE ' REFERENCE BENCHMARK (TSC PROJECT NUMBER 5271.002): TBM 7 BURIED TELEPHONE LINE �.r r_:- ,f- _.__._____.____ A RAILROAD SPIKE SET 1 FOOT UP ON THE SOUTH SIDE OF POWER == {-y GAS VALVE �> POLE NUMBER HM 14261 20 FEET SOUTH OF SOUTH CURB OF �� = A STANDARD USGS DISK IN CONCRETE STAMPED 95 RHP 752 1951 A COPPERWELD AT THE RADIUS POINT OF PECOS COURT. TELEPHONE LINE AT THE NORTHWEST CORNER OF 146TH STREET AND NORFOLK AND 146TH STREET, 1150 FEET ± EAST OF CHERRY TREE ROAD. CD C.O. CLEAN OU T WESTERN RAILROAD, 18.5 FEET NORTH OF THE CENTERLINE OF ELEVATION: HOLEY MOLEY SAYS W -- - - - - - -- WATER LINE 146TH STREET. ELEVATION: 770.76' (NGVD 1929) m zv z, 785.49' (NGVD 1929) DIG SAFEL YWATER METER �. GAS LINE TBM 4 ELEVATION: E VA TI 0 N : TBM 8 (� 751.46 (NGVD 1929) 0 ' A RAILROAD SPIKE SET 1 FOOT UP ON THE SOUTH SIDE OF POWER s SANITARY SEWER LINE; MANHOLE WATER VALVE A COPPERWELD AT THE CENTERLINE INTERSECTION OF CHERRY TREE I TB M ROAD AN 2 (TSC PROJECT NUMBER 5271.002): D KL NGENSMITH BLVD. CAUTION �-- `=S POLE NUMBER HM 14273, 20 FEET SOUTH OF SOUTH CURB OF FIRE HYDRANT STORM SEWER LINE; MANHOLE, f 146TH STREET, 630 FEET + WEST OF GREYLAN PLACE. TOP OF THE WEST ANCHOR BOLT ON METAL TRAFFIC POLE, SW. - ELEVATION: � _ LOCATION OF ALL EX /STING UNDERGROUND CURB INLET, FLAT INLET & EN DSECTI ON M.B. MAILBOX QUADRANT OF 146TH STREET AND RIVER ROAD. 773.68' (NGVD 1929) b UTILITIES SHOWN ON THIS PLAN ARE BASED ELEVATION. , not limited to, manho %s inlets valves & UPON ABOVE GROUND EVIDENCE. including, but FENCE LINE ELEVATION: 759.73' (NGVD 1929} 760.79 NGVD 1929 - marks made upon the ground by others.) AND M.C.S.R. MARION COUNTY SURVEYORS RECORD � W P.W.P. ( ) TBM 5 ARE SPECULATIVE IN NATURE. THERE MAY ALSO 0 POWER POLES O PK NAIL SET S & A TEMPORARY BENCHMARKS: BE OTHER EXISITING UNDERGROUND UTILIITIES A COPPERWELD AT THE CENTERLINE INTERSECTION OF SETTLER'S FOR WHICH THERE IS NO ABOVE GROUND Q LIGHT POLE TBM 1 RIDGE AND STAGHORN COURT. EVID04CB OR FOR WJIIC�f NO ABOVE GROUND CAPPED REBAR STAMPED � � � EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS 0 7TS THE LA W OF SAID EXISTING UNDERGROUND UTILITIES DRAWN BY: CHECKED BY: (S&A FIRM # 0008) SET A BRONZE DISC SET IN THE EASTERN HEADWALL OF A CULVERT, 2.5 ELEVATION: CALL 2 WORKING DAYS BEFORE YOU DIG SHOULD BE VERIFIED BY THE CONTRACTOR AAA /KRG, B KR FEET SOUTH OF THE NORTH END OF HEADWALL, SAID CULVERT IS 757.78 (NGVD 1929) PRIOR TO ANY AND ALL CONSTRUCTION. r�~r ALONG RIVER ROAD AND 1100 FEET + NORTHEAST OF THE 1800-382-5544 SHEET No. ENTRANCE TO PRAIRIE TRACT ELEMENTARY SCHOOL. DISC STAMPED CALL TOLL FREE TREES TO BE REMOVED "HAM 25 1964" PER INDIANA STATE LAW IC8 -1 -26. { IT IS AGAINST THE LAW TO EXCAVATE ELEVATION: WITHOUT NOTIFYING THE UNDERGROUND C 10 1 LOCATION SERVICE TWO (2) WORKING S & A JOB N0. 749.52' (NGVD 19 2 9) DAYS BEFORE COMMENCING WORK. 5279051 - ,i L_ .Tf `u iL �. O . . N O N 0 fu J 0) .(�: V d c =v 1 C7 °o U Cn U) V • Ln M NOTES: 1. DECORATIVE SIGNS, SPRINKLER SYSTEMS, TREES, LANDSCAPING MOUNDS LIGHT POLES, OR OTHER SUCH AMENITIES ARE NOT PERMITTED IN THE i RIGHT -OF -WAY. 2. A DEBRIS GUARD SHALL BE INSTALLED ON ALL UPSTREAM OPEN -ENDED INLETS AND AT THE POND OUTFALL PIPE. 3. NO PROPOSED DRIVEWAY SHALL ENCROACH ON ANY SIDEYARD EASEMENT. 4. THERE ARE TO BE NO WATER VALVES OR MANHOLES WITHIN THE PAVEMENT CURBS, OR SIDEWALKS. 5. ALL EXISTING PAVEMENT SHALL BE SAW CUT TO A CLEAN EDGE WHERE NEW PAVEMENT (FOR WIDENING) IS TO BE INSTALLED ADJACENT TO EXISTING PAVEMENT. 6. ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF -WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. 7. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE APRE- CONSTRUCTION MEETING TO REVIEW THE DEPARTMENTS CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF -WAY. 8. FINISHED FLOOR ELEVATIONS OF ALL STRUCTURES SHALL BE NO LESS THAN 2' ABOVE ANY ADJACENT 100 YEAR LOCAL OR REGIONAL FLOOD ELEVATION (WHICHEVER IS GREATER). / r f 9. ALL SUB - SURFACE DRAINS SHALL BE DOUBLE WALL HANCORE HI -Q OR d .t'`' .4i EQUIVALENT. ?.i l -' :1. � //1__1 1. . I . -1-. I � �. I 7 t: I -' 1. a 3 �. a 7 r V J =_ !' ;� j 4e L � .J ° te, ' ' } fir. / s .. ! r r m - ; - . } - '1 _' r;. ?. f 1 - Y I 11 `y L 1 �__ J .' - , -- r r i '' -, l ' ^, ` Q - \�M B ` - A. >, Z_/" " r t i t t r / �r 3 M.B. �' r - / fd r , r _ir ,'tom s t _ r - , / X -¢ .r l -.. r- - �/ 1. I ♦d jJr _ I / / 'V__�/ x, , { -s �'• f' I f Li t / ' / �1�c�s I � . l ., r � _,�', - . I X / .3 .k� f k w Al S' ,'. _ - .) - - '. y:. If -tic z 4 = f '- / '{ ; -` J ,. _ F{* / �v v n O . / !� / 3 jrf, t) qI ,." psi ` ` 1 -''^ i I % ,_ _� - _- z �`i' , - 11 � � I I- .; . J I - '. / �� / \ - f ,}' j s AO t. '. ,,�_,. , I / / jr i :4 / 11�- . ,,, a // ,- ' 1 1_�/_, i pi ); fe y e` /' ice, ' h I �. �, V\ _,.,f��111 ell . I,- \ "*'� " ., -1 I - I . i � `e 1,3 /,/ y . z , I - q �, z. \ , , t f � / 1 . ? )/ ; e 1�� - N �,. �, 11 --x,- / � i, � / . , I i / I . i \,.,"�,\,., . I , � i z '� .'j ' k 1 � I � . ,5 I.. / 4 � . � .- �-,v/ !��',J �_ .4 ., � � � . � , :, _'t-, I ,e- I � I ; � .. I / .X . .1. ", i � z /,1 J : � t ' i� :FaL" r= f 1 i "" / / ! ` a 1 r � / / / //! � 3 t 1 ,Y ;•! I e I - � . � 11 , � / � ��!,,�-, .1 �-�, A-� I � .� r , }f i j .� -,i' i , is r' \ \F r� 7 t j , Y� r f f �,. 1. I . I � / e / - - ..r a r' i f- X `L �y i ice , w, y I 11 / , a ! a '` f 7. ?. t i ,• - } t - r�t ;vit`, r ., - i - ; r f 9 . f l•' {, R .,, -.) �,b i ', a (,-� yam-, .% t 1� -11 �� X t kL- ` + � r } 1 1, e y . � I / 1� V , - . . \ � t ,�� \ 3 EARTHWORK: 1. EXCAVATION A. Excovoted material that is suitable may be used for fills. All unsuitable material and all surplus excavated material not required shall be removed from the site. B. Provide and place any additional fill material from offsite as may be necessary to produce the grades on required plans. Fill obtained from off q p site shall be of unlit as specified edfr ' o fill quality s herein. and the P source approved by the Developer. It will be the responsibility of the Contractor for any costs for fill needed. 2. REMOVAL OF TREES A. All trees and stumps from area to be occupied by a road surface area and building pod. Trees and stumps shall not be buried on site. 3. PROTECTION OF TREES A. The Contractor shall, at the direction of the Developer, endeavor to save and rotect trees of value P and worth which ch do not impair construction of improvements rov emen is a s designed. B. In the event cut or fill exceeds 0.5 foot over the root area, the Developer shall be consulted with respect of protective measure to be taken, if any, to preserve such trees. 4. REMOVAL OF TOPSOIL A. All topsoil shall be removed from all areas to be excavated. Topsoil should be stored at a location i on wh ere it will no interfere rote rfer e with . construction operations. The topsoil shall be free of debris and stones. 5. UTILITIES A. Rules and regulation governing the respective e utility shall be observed in executing all work under this section. B. It shall be the responsibility of the Contractor to determine the location of existing underground utilities t es 2 working 9 da s P rior. to commencing ncin 9 work. For utility locations ons to be marked e d c I f Toll Free 1- 800 - 382 -5544 within Indiana or 1- 800 - 428 -5200 outside Indiana. 6. SITE GRADING A Do I a I cutting, filling, compacting of fills and rough grading required to bring entire project area to subgrade as shown on the drawing. B. The tolerance for paved areas shall not exceed 0.05 feet above established sub 9 rode. All other areas plus shall not exceed 0.05 feet p s or minus the established rode. Provide rou g ndings at top and bottom of banks and other breaks in grade. C_ The Engineer sha)! be notificd when the Contractor- has reached the toieranee as stated above, so that field measurements and spot elevations can be verified by the Engineer. The Contractor shall not remove his equipment from the site until the Engineer has verified that the job meets the above . tolerance. FORM \EARTHWRK t� } h4�� 47 l, �• " t -), , ,_� Y . -i ; ) , �:+t r ' % i l tf-' -� -} rr ,r " '' J� ' l +` M ^ "�_� J d' 1/// / J' X i �, � /:.' � r "I . r ,..!-,I J I s a _( { t � � ' ; � n * `' /am � ' ;. . :, x , %, ' L, ;. f -$ i-'-`, .,_. _.-1 t `'' - .. ..., LJL I 4, � ...... ,I i ,,, i , i , i , i t •- r _ i T f. s f__ v J ! �. f e _� ,� ' ,t r 11 - ! f _ s - �w k t~ '; �' i ~ r > � / �_ _. ; 44 7 a t _ 1. t__% ! `4 ! i ' ,_._ t %__ t ` L..,; i'y � 1--•: i � i `, ? , .4 _-' j `, i'' I '�, I 1 j'., �.F � : f i 1 1 j° ; `• } Y , , 11. ! t - _.. ._ , V f k , t_., l.- i i _ ._ , . t '1 S ` _ 1 ! ; ; r� 1 i i i - I - i \ ° \ • ' ' L 1 i i , -.' i 1 (-': t l [�,- S r i i .,3 �i i 's' ^I . i f- F ! }-,t ! ! �-, r ', `` t i 1 r _ f . 1 ~4 ti' i i+ r - t ! i S - � }_, .-. i t __ } I~_ i -•_ �' / ! i '� i i� - `r- % , r: j L _.. �.� ... _J . ! , _ 1 . • i �,� ; `e ! w__ %`".i ; '� t.,•i i_J 1 'i S Ti � k --� L_ '„_~ � 3 i-_ ` t. , . > ; �^ �_ , - A l t ,_ - t Id 1-1 i f' aw. r� s r- y w t i � � -..1 n f S _r t i ` t � -S ! i v_ _ 1 `, r i i t i -i' ,J`' - ) i , f $ -•i ; t :,1 ; i r � ., w r.. "\ i i i ~. _•,7- 1-- i;i `� .� yr. -.ti r -- :1 r, _., r�: r - s-' . , - - �, ! i --_ '' _T ,...i +_,.i i '.., c �. ! ! 't �.,r' �r k -ti �_/ ! ; L._. 1 L V•a i s J r i i'°r � / �.,1 i ' ~I �- r �..4 .11 2 __ y . I `+i L_ � i ,j , I -'3 a �.... i ' .. ,.../ ( , ! r - P 1 ' •''� •{ _ ^ -.i _- j^. .._� 4_ L :\ 1 1 •.7 i t P ^1 j-.j j_.. iY y ; i D , f•--' _ S`" ' _ - _ - . . 1. v i. -_ . �.` 9__t `J'i I i i i� i ! t t r L_,� l a ' ,J i \ ! -' Lr.. i ' 1. i" i e .:._� •y -'`=! ._z L �' � I `r , 1 _ - _ i S__L_ , ,'± ..ij ; i 1 i aJ f..i� -; I 1 ' \!_a:�,, �i `i i "; `'� i {" i i� 1 \ - - r~- i r- � / r., L =. V f-`. _ . 7 1 i r i3 t � 3 i`� i 1__ ! 'vf __ , ,•,.. T L__ v, ! , i " i.f 3 `,.i f�\ i...a 1 i.._ i 1 , f- ,{, i e • ,t.l r "'` rr -I._ -i -•, �•- - , f--. , , i _ .. it) ? 0 J -� _ f \>� , i 1 1 `a_: i ' �« i i._1 «.�+�'`i -• ` �i" I T-' s _ _ ! . ,. -, -, . ,L). . L_._ L_ l_.. �Y t - -t -I 1 't_,r ia�J / 'mo t.. . ./ - -j } , h .Y, i i I _"; , - ; , i 1 __J � ,'A �, ! i r' i 5', L_! f \ ., -'{ } i i .' ; i , j j -a L-.. 1 i..-_ _! i- -,1 `, y L - i f ,1 hit • '' , t _ : A L. i i \3 _ , s i _ -ti s i � •t _ f: i f 3 ! i t i ! i i i , i i i t 3 - , W� ( '1 .r a . , . i i _ S u t _ , t v } ' t LJ a i i_,= r t-e _� ! - -'-, - .,.- -, { r 1 _ ,- - . 1. i'. i z 1 r_ e i .. ! , _ 1 r f", j� -Z r ; _ i1 -r- - '-- -.. i \ � i + -, . . ,._� i•- t +.., y iv a� , , 1 i..,..1 ; .. . i _r ,,q f.,\ _. 3 fi r- -� , - .- -- __., tv 7 , } !1__ , i :, r L_ i ,� 1 4, .as .1 - ice,. , , !r t_L_i<i t `1 N ( j1_,�_I� Ti i -� .t A r�' , 1 i r t a ,-- _ } t y, t ! i "; n L �! i i r 3 L s r r S __ i o } C . i, -, - t _ /_ _. i I P.. �Ii 1. -, , , - " 11 % �, "- , C7 L_ L U_ i - J � _. -1: , , " ` i .i J � . F _j - � ­ " " M.E. M. E. ,�, i i i v - :\ __� i ----_ �vJkll % s -; T TB Mil `y, 1 i�__ O _-�_ l t ) i__ '«/ ( �, -_ i , , ___ r . _ -., i ! 1 tt i v z .J ? ! t�J 1 -i �._ i -�i i } ! r L. -- _ > - i - t , 1 r i - � l- ... L.� t•.. j ' j .. i I i .i ) i ._I i 3 �_ , 4. -. '._J - F . i_. 4 f ��' ! 1 i +, ! 3 ( i :_ _ f i d r- ': 1 S � , i t I t t. - _ _ , i ­i -_ .: 1. 4 _ r� �t i i - t L" ! S I _ y }�1 i i .1 1 4 _ �_ -1 . `_. r.,.� 0 2 _i Li 1 iJ . 'r \ - A , !! ., t 1 } ` t - J i ! ^3 ` t .� i . - _ i i _ - 5 i i- ... _ s �_1 � -� _ , `: i 1" � �__ li_ L� _ 1 - • �.,' �1 i i "{ ,� �-. -_ _ �' ;:. j:} i.,, > � �, �. S L__ : { �✓ L!. 4 t. t.` f,. a Y` t.'- ,' `r -- ` ^t- -I- t 5 i _.i r\ ,' !r j- i -_\ -1 _ __ _ _ , , ._ i -_ 1 i _ ,_ _ - i r-, i _ _ 2vI ;= -; _ _ �} t_ _ F' , �� S , i- +' i i - ,_ _, _ --. � � t { - ; i i - +' r, , -,t B,5 -! ,- FIN r.: _ e _ r J r- �. } }� i, i e- i T i ti t 1 - i F �. - _ t s i i i �- i . t- S� . + - i� i k' $ i__ .-.- -..,J r� ! t._. L� t4 i .....- t 1 t ! , `� i� F , + - i - :_Y. ry =.._ 1, '__. L_ i 'ti �.._- 4 a.. `'✓ , t j -y ...i i ..-..' i__ : i .� _- , S ! } .'y, E 1 _ I-r- , 'E" ;_, L.J L' , Ly . r _ r "" , a J 'L� t i iY � ,U +t ,"_ f S r. s- i Y r-- s • „f r f-' f�, `". i ,< � r. -- - r - - � - e .1 �_� i i .__ ! 1 r t.__ ,._ �_JS .�` i s ...r L.._ t . V i : i ' i ' - tY '�\ 1 _ - .__ i t__ ! f 4 i_ . i ''i< i i__ , i ...3 .-... - i i i,4, , '� t _ , __ � i__ s r �-. - _ , t'S r ! S S i t( t L_ , i Q L_ . _- I _. a ' s a L_, ! V : f `�,l '.._/ i i L._. i \ ' i r_- iI -._ �-..,! + i , , , ,._ !...'� ;` =`. '� i i � J t { -•\ i _..; %r..., > ; ._} �._ 1.. •, t ,i S i - . lr --; -P , } _v ; v`i 0 1 ti• ♦, r t s -- ! i _ -r- • y } F rH i r t. t- - -- t' -, :- ! r - _t i _ i_ r J; I-'4,1 �'!i✓ ,i._ i t i t _. i`v 1 \' .ii \'1i._ 1 ; r_ i {{1T ! r r _i !i t i r. 1� �.`,r i .�` ! '-"1 ,r",.. : , . _ - - - , _-_•- - `l Li- 1 N i J , � i ! i l � o 1 r i . { . . a , � _, , 3, - -' . I 11 "Z , - ; . ) , - - I V. E. . 1. i�J 11 `/ l� 1 . � } M. E. 79.6.2 LEGEND <::__:__::::: EMERGENCY FLOOD ROUTE 848 EXISTING CONTOUR O EXISTING NG SANITARY SEWER 1 1 � EXISTING NG STORM SEWER 848.0 PROPOSED GRADE --- -848 PROPOSED CONTOUR PROPOSED SANITARY SEWER PROPOSED STORM SEWER 00< PROPOSED SWALE PROPOSED 5' SIDEWALK (BY HOME BUILDER) PROPOSED 10' PATH q- LOT NUMBER N.P. PAD ELEVATION M. F. P. G. MINIMUM FLOOD PROTECTION GRADE ° DENOTES 4" SUBSURFACE DRAIN TO DENOTES 6" SUBSURFACE DRAIN ROLL CURB L. 0. LOOK OU T W. 0. WALK OU T M.E. J MATCH EXISTING 1. M.E. K i-n -- - - - - -- - -- - - - - S. S. D. S.S.D. ' TYPICAL UTILITY LATERAL PLACEMENT SCALE: 1 °= 50' M 3 +66.69 787.9 1 M . E. "HOLEY MOLEY" . SAYS, CAUTION LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & marks made u a t � ! � ��'tQ ������d b� o�'r�ers.� A4vu ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS. NO ABOVE GROUND EVIDENCE OR FOR WHICH H N 0 ABOVE E GR OUN D EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS 1-800-382-5544 OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR CALL TOLL FREE PRIOR TO ANY AND ALL CONSTRUCTION. 1 -800- 428 -5200 FOR CALLS OUTSIDE OF INDIANA W z 0 LJ otf Irf Q Li 0 %% . O. R I NEy '-*. .... ............ % ., ... ••'�1STE%�-. • �L�,: % •q � � i ` ; ,! • . a ~ • Now r = : 1420-0495 = = ... _. *. ..O . .00 . 'o =. STATE OF �, t .� • •••. /NDIANP..••' � '0 "* S�6NAL E� ��.�`. 1:1� z a w J > � O I-- Z CD W � W � W O � I.- W � � I I W = I-- U 0 Q z Q 0 z I- z 0 U z 0 I- L Q D__ J L1J Q U DRAWN 8Y: CHECKED BY: AA KRG BKR SHEET N0. S &A JOB NO. I 52790S1 i�__ O '*,�� � co N 0 fW t._L� . i� I— 11._ U • 40� cif `0r w W �> t-n O 1 14 0.,;d- Cif O C M V) 00 M _.< V o O co M4- rV O z d- z r-,.- --' I J x N 4< 48 ^L__` W/.- 0 U r�_ 48 cif U-) OM w m17 W -6 rn^ L I - I z M W a.) Z • / o0 W W � o � o F- J CD Q rl-) W z o c J O-) C Z 0 (/) U z a w J > � O I-- Z CD W � W � W O � I.- W � � I I W = I-- U 0 Q z Q 0 z I- z 0 U z 0 I- L Q D__ J L1J Q U DRAWN 8Y: CHECKED BY: AA KRG BKR SHEET N0. S &A JOB NO. I 52790S1 L Ln M It w 0 N 110 N 0 rn "0 a Cn =o ME /n V N i rn V) 0 N Ln i " `J tt I tM1 z b J { V: 1 O ,i V• 1 s I - J _ a" R : { =t ; l L .a t 21 R.C.P. . .P. ®0.30 21 - \ i D 4 _ �r r r r` i 7 + 01 .8 J i L� s�. l� _ 7 1 W 79.6 i J c i _ - Z, P r s 5 �O rs 3 '.� z z� 1 -� 1 � s+ '�• .. - �- -_ r 1J�1 i l ` a 1 - T i Q , v V/ M J r z - -792.4 i( / 1 {- P 4 v O fr J f O N - x (n N 791*8 I fa i r v cr) ,s J - t x J - t ,v^) + f J i - e i r f \� ¢ 'i . r _ .✓) � i F _ t.T� ' !' � _ _ _ _ V _ w � I tom, I � 2 11. T, } i ` i � r , e r` a S,s Fr //��// /AN - {fin .t' V • a, F a \ o0 �2 } t _ : ,z 9 j a � tea• 110 f Yn 0 O N CD n� t ... t i • , e,. r, k C.P. ....r°i,m / , ; - i ..`.__ � _/ ; f ; e ; :T ,. -' ? f._ -.''' -� .- ..'_.1 F ! \•%' O :l <:v� ..'i. � /i. - ....s.. � - :�r�o�`�a . �i�� \ , � \ .. I I,. ;I I � i _ �'. _�- I F 19" R 00 3 ` r i' M.E. ti. S. S.D. sr,F W W W W WATERLINE i TYPICAL U Tl LI TY LATERAL PLACEMENT EARTHWORK: 1. EXCAVATION PROPOSED 5 SIDEWALK A. Excavated material that is suitable may be used for fills. All unsuitable material and all surplus (BY HOME BUILDER) excavated material not required shall be removed from the site. NOTES: PROPOSED 10' PATH B. Provide and place any additional fill material from offsite as may be necessary to produce the grades required on plans. Fill obtained from offsite shall be of quality as specified for fills herein and the source approved by the Developer. It will be the responsibility of the Contractor for any costs for fill needed. 2. REMOVAL OF TREES r surface area and building pod. Trees and A. All trees and stumps from area to be occupied by a road su ce bu Id g p stumps shall not be buried on site. 3. PROTECTION OF TREES A. The Contractor shall at the direction of the Developer, endeavor to save and protect trees of value P � P and worth which do not impair construction of improvements as designed. P P 9 B. In the event cut or fill exceeds 0.5 foot over the root area, the Developer shall be consulted with respect of protective measure to be taken, if any, to preserve such trees. 4. REMOVAL OF TOPSOIL A. All topsoil shall be removed from all areas to be excavated. t soil should be stored a a o Topsoil location where it will not interfere with construction operations. The topsoil shall be free of debris and stones. 5. UTILITIES A. Rules and regulation governing the respective utility shall be observed in executing all work under this section. B. It shall be the responsibility of the Contractor to determine the location of existing underground utilities 2 working days prior to commencing work. For utility locations to be marked call Toll Free 1- 800 - 382 -5544 within Indiana or 1 -800- 428 -5200 outside Indiana. 6. SITE GRADING A. Do all cutting, filling, compacting of fills and rough grading required to bring entire project area to subgrade as shown on the drawing. B. The tolerance for paved areas shall not exceed 0.05 feet above established subgrade. All other areas shall not exceed 0.05 feet plus or minus the established grade. Provide roundings at top and bottom of banks and other breaks in grade. C. The Engineer shall benotified w hen the Contractor has reached the tolerance as stated above , so that field measurements and spot elevations can be verified by the Engineer. The Contractor shall it Engineer has verified that h job meets the above not remove his equipment from the site until the En e s the 9 J tolerance. FORM \EARTHWRK 1. DECORATIVE SIGNS, SPRINKLER SYSTEMS, TREES, LANDSCAPING MOUNDS, LIGHT POLES, OR OTHER SUCH AMENITIES ARE NOT PERMITTED IN THE RIGHT -OF -WAY. 2. A DEBRIS GUARD SHALL BE INSTALLED ON ALL UPSTREAM OPEN -ENDED INLETS AND AT THE POND OUTFALL PIPE. 3. NO PROPOSED DRIVEWAY SHALL ENCROACH ON ANY SIDEYARD EASEMENT. 4. THERE ARE TO BE NO WATER VALVES OR MANHOLES WITHIN THE PAVEMENT, CURBS, OR SIDEWALKS. 5. ALL EXISTING PAVEMENT SHALL BE SAW CUT TO A CLEAN EDGE WHERE NEW PAVEMENT (FOR WIDENING) IS TO BE INSTALLED ADJACENT TO EXISTING PAVEMENT. 6. ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF -WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. 7. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE - CONSTRUCTION MEETING TO REVIEW THE DEPARTMENTS CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF -WAY. 8. FINISHED FLOOR ELEVATIONS OF ALL STRUCTURES SHALL BE NO LESS THAN 2' ABOVE ANY ADJACENT 100 YEAR LOCAL OR REGIONAL FLOOD ELEVATION (WHICHEVER IS GREATER). 9. ALL SUB - SURFACE DRAINS SHALL BE DOUBLE WALL HANCORE HI-0 OR EQUIVALENT. i 4 t i I \ f t # 't F i i \) , I'. i i �^ �( ha = r C i r .._ ._.. ��. `f t_.1 ! s a_ i.� 7 i � a v _. ,.M _._ , . I ,. (~'. F r +t i _ ' . , s j ".. a �.J # a'2 F � \. _.i �e�• ... .._ .�< ...% tt� k 7 , t } ^�l ;i f j:_ i,. !! r. ^' J i- • '�• i f '� I >, 1 + ; b. F - �. - f-', �.j ^• i ,':� - -, �,': _•F\, I ./� . I f,Y r ltf , i, � 4i... ., v, S L.# . 1 # , _ t�l ✓: 1k } R i-... i `v ?� E E3 � I Y C,. ! i i a i e`"`� i �� t <.• s �.° ... 4� : .,# J 4_. �� � , (t.�% i . ? , ..^.. Fr••� +Y^t {i + (t -mot i,_1 ; -: i L i. U I f _ -_ � �� _F -- C:�_ _.,_. f,, J -, I : , r-- ^•� r-• : - ( < . ••-- :. i ; \ i 4 :'-\ -T . 1, f # # 1 it�( .,,J L.��..1t1t',Itf. -i'4 .:�;^ t `i 1 t'_C,�.. /":,`,i�.r. #-,i ,fi.:5..1`_/:._.� +4 #�_ r _ 0 1 # # I~ �" F i 'i L 1� i Z_� i \ RIV Sri '�..... f i r ., � i. r"1 f � R �� i r_.,• i..� ; `, t'`1 i \ i r �__t �._ 5 4 _; i_ L '. � � , • _ay i i �•� 7 _ Lj ati r 1 i'4 it. # t Lt�: F, d i# s. Y1, {.' .. s _..,_ .✓ 4_..% c.s. _._ _F _ d , ., _ �.! y _. ._. _ F.._ ; y - ,r'- ' --i L •"?; i i s # k \ 1 r # i ,t 1 � ++ )) j V , 5 \.. � � : k 4 L. f #,..' �... i ._ / � l .. �. -.,.. / . _ __ • i_.1 i. _ . i_ � 1 i .. I -`+ L V _ 3 � 1 � t F 3 !� �' J `• i � i t- ._ -_ { �"1 -r-, i .. �> -` n„ I .,. � ` _ ...._ -'. t r i � t :_ `. V _ � i -- , -- } t t t., i., i - #� ?-- i.. t t..., S r.. ; a, 2 i� -� ' �, �` + 1^ y >~ �`• !# 7 #_ i 's i .. :! Y .. `_ ! s i ' 'i i t i '. • i i r 5 i `� I L y v5 / _. I- i a r, y, may) ,� ,i •> Y. ; •f� Ij 's t - ;_ i .� - i ' : r� ` + r• ' t ,T ' .i ;-,4 > _ / _.� • I. -1 'w 7 e 8 i..._ F.._- 1 ,}• i I t- c t 1 i ti i 't 'k• Y tF I � r• i i r i . 1 i t iii i 1 L" _ t'. \ i De. �., { � t l'' 1 3r 1 . .. ' -✓ .... I 1. .J ._._ i? e 1' -r. u t ..., t_.., a 4 F :.�' F. t 1 'i 1...._ i 1 ♦ F f �. � _ .... - � - f t \ i t_.. S_.._ 4 \..l I _� ♦ . -. \ 2 N.P. M.F. P. G. LOT NUMBER PAD ELEVATION MINIMUM FLOOD PROTECTION GRADE DENOTES 4" SUBSURFACE DRAIN TO LOT DENOTES 6" SUBSURFACE DRAIN ROLL CURB L. 0. LOOK OUT W. 0. WALK OUT M.E. MATCH EXISTING "HOLEY MOLEY" SAYS: CAUTION . 1-800-382-5544 CALL TOLL FREE 1-800-428-5200 FOR CALLS OUTSIDE OF INDIANA LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND_ EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS 0S OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. M z 0 V\/ / W/�/ LL Y CY Q w 0 Q, Q i • No. 10200495 -o =. STATE OF ZONAL O N O _W LL W U 112.0f 0 w Ln CD N ry O N L I M U ° 00 Q z Q � G) `0 U) z 00 V o co = w w z Ln 1- If.L - d- °O �- Z W C o O �-- J U L Q Z_ � � o W C/) Q Z F- 0 up) U i Z W O J W W D w I-- (of) w 0 CD n )0-- W I U Q z Q 0 z z 0 U z 0 Q J W Q U DRAWN BY: CHECKED BY: AA KRG BKR SHEET N0. S & A JOB NO. 5279051 L ry a Cn Ln Cn O 0 N ko N O 9 Cn c cv a e O O W CL I 0 U Cn 0 M N Ln THIS SHEET TQ E41ILWS ED F�JR R .�i �IOO C .................... PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL: CRWHITE DEVELOPMENT, LLC 510 FOX LANE CARMEL, INDIANA 46032 PHONE # (317)848 -2830 CONTACT PERSON: CHRIS WHITE o 0 0 Construction Limits ...:, (SF) ii==iI Denotes silt fence to be installed >C Temporary straw bale dam to be removed during blanket w installation. O Denotes permanent seeding & mulch areas Seeding rate: 130# /acre or 3# /1000 S.F. 0 Seeding mixture: 25% creeping red fescue - 35% perennial rye CD 40% Kentucky bluegrass \�\ Denotes seeding w /fiber blanket #S150 by North American Green Seeding rate: 110# /acre or 2.5# /1000 S.F. Seeding mixture: 38% Kentucky 31 fescue w U 19% perennial rye 0 19% annual rye 14% orchard grass OO.f � 10% Kentucky bluegrass NOTE: ++++++++* Denotes temporary seeding & mulching. AFTER THE LAKE IS COMPLETED Seeding rate: 50# /acre SIDE SLOPES SHALL BE STABLIZED Seeding mixture: 100% perennial rye. WITH A FIBER BLANKET. Q Temporary geotextile bags to be installed at curb inlets. The following is a list in sequence of construction activities to control soil erosion: 1. The contractor shall schedule a Pre — construction meeting with the Hamilton County Soil and Water Conservation District prior to any construction on the site being started. 2. The construction entrance installed. 3. Posting sign installed 4. Install perimeter silt fence 5. Maintenance and Refueling area constructed 6: Concrete washout area constructed 7. Construct Pond. All material excavated in this process shall be used to grade site. 8. Grade site (sides of swales, mounds and ponds to be seeded and mulched immediately upon completion). Temporary seeding shall be recommended for all swales and disturbed areas that cannot be final seeded within a 15 day time period to prevent erosion. For temporary seeding, the contractor shall utilize a fast growing seed of either oats, annual rye grass, wheat or rye depending on time of year. Disturbed areas should be kept to a minimum at all times. All Common Areas to be topsoiled & fertilized based on soil type utilizing low or no phosphorous fertilizer. SCALE: 1"= 50'. 9. Storm inlets are to be protected immediately after installation. 10. Contractor shall control mud accumulation on all streets surrounding project by installing stone surface at all locations where construction traffic leaves the site. Dust shall be kept to a minimum by utilizing sprinkling, Calcium Chloride, Vegetative cover, spray on adhesives or other approved methods. 11. Maintain all filters and traps during construction to prevent any blockages from accumulated sediment. Additional seeding and straw bales may be required during construction as specified by Engineer or Soil Conservation Service. Payment for additional straw bales shall be at the contractor's expense. Payment for additional rip —rap (not shown on plans) and seeding shall be paid for on a unit basis. 12. Contractor shall install all sanitary sewers, storm sewers, subsurface drains, and water mains.Strow bale filters shall be installed at all storm inlets (including street inlets). 13. All disturbed areas to be temporarily seeded. NOTE: TO CONTRACTOR 1. Prior to any work commencing contractor shall install stone drive at entrance, and all silt fences shown on plan. 2. Upon completion of the storm structure from being built the fabric drop inlet protection is to be installed ON curb inlets and straw bales on yard inlets immediately. 3. Upon completion of the swale construction, contractor shall notify engineer to as— built, upon review of as —built engineer shall notify contractor to install the erosion control blankets as soon as possible. BENCHMARK HISTORY: ELEVATIONS BASED UPON THE BENCHMARK INFORMATION PROVIDED BY THE SCHNEIDER CORPORATION FOR THE EARLHAM PROPERTY, TSC PROJECT NUMBER 5271.002. RAN A CLOSED LOOP FROM THEIR TBM 2 AROUND THE SITE. JRL FIELD BOOK 428, PAGES 118 -125 REFERENCE BENCHMARK (TSC PROJECT NUMBER 5271.002): A STANDARD USGS DISK IN CON_ CRETE STAMPED "95 RHP 752 1951" AT THE NORTHWEST CORNER OF 146TH STREET AND NORFOLK AND WESTERN RAILROAD, 18.5 FEET NORTH OF THE CENTERLINE OF 146TH STREET. ELEVATION: 751.46' (NGVD 1929) TBM 2 (TSC PROJECT NUMBER 5271.002): TOP OF THE WEST ANCHOR BOLT ON METAL TRAFFIC POLE SW. QUADRANT OF 146TH STREET AND RIVER ROAD. ELEVATION: 760.79' (NGVD 1929) S & A TEMPORARY BENCHMARKS: TBM 1 A BRONZE DISC SET IN THE EASTERN HEADWALL OF A CULVERT, 2.5 FEET SOUTH OF THE NORTH END OF HEADWALL, SAID CULVERT IS ALONG RIVER ROAD AND 1100 FEET + NORTHEAST OF THE ENTRANCE TO PRAIRIE TRACT ELEMENTARY SCHOOL. DISC STAMPED "HAM 25 1964" ELEVATION: 749.52' (NGVD 1929) TBM 2 A COPPERWELD AT THE RADIUS POINT OF ARCADIAN COURT. ELEVATION: 771.54' (NGVD 1929) TBM 3 A RAILROAD SPIKE SET 1 FOOT UP ON THE SOUTH SIDE OF POWER POLE NUMBER HM 14261, 20 FEET SOUTH OF SOUTH CURB OF 146TH STREET, 1150 FEET ± EAST OF CHERRY TREE ROAD. ELEVATION: 785.49' (NGVD 1929) TBM 4 A RAILROAD SPIKE SET 1 FOOT UP ON THE SOUTH SIDE OF POWER POLE NUMBER HM 14273, 20 FEET SOUTH OF SOUTH CURB OF 146TH STREET, 630 FEET ± WEST OF GREYLAN PLACE. ELEVATION: 759.73' (NGVD 1929) TBM 5 A COPPERWELD AT THE CENTERLINE INTERSECTION OF SETTLER'S RIDGE AND STAGHORN COURT. ELEVATION: 757.78' (NGVD 1929) TBM 6 A COPPERWELD AT THE CENTERLINE INTERSECTION OF SETTLER'S RIDGE AND PLANTATION LANE. ELEVATION: 773.87' (NGVD 1929) TBM 7 A COPPERWELD AT THE RADIUS POINT OF PECOS COURT. ELEVATION: 770.76' (NGVD 1929) TBM 8 A COPPERWELD AT THE CENTERLINE INTERSECTION OF CHERRY TREE ROAD AND KLINGENSMITH BLVD. ELEVATION: 773.68' (NGVD 1929) QIYI M Cn w o cn Z W LIJ Z Q 0O O p > Z U W Q Z o Q o- t-If W W 0L i2L p W W Cn Cn W W af IIIIIIIIIyI co U-) 0 0 W O H Q N N p p, R I NEly .,'. �Q- STE�q�c ••••• • iG �� Q` - No = — 10200495 -o •: STATE OF Q♦ ♦ O • ,c� ••. NDIANP �•, ZONAL O CD \ N C) _W LL F- LiJ U z Q J J O Z O U z 0 0 w W Q z Q O z V) Z O w U O Z 0 0 _J - Q CD w U W 0 OO.f � CD N I Q 0 0 t--) o cfl d- °O r,- - (J C:) Q aN0 a� X 48 V) CD CD ono W rn Ln W o r,- LL- �—° J C7 Z p � a6 o W � Cn Z a- W O � o � U z Q J J O Z O U z 0 0 w W Q z Q O z w w I-- W I U Z O w U Z 0 0 _J � Q CD w w I-- W I U S &A JOB NO. 5279051 J w ry Q U DRAWN BY: AA KRG CHECKED BY: BKR SHEET N0. S &A JOB NO. 5279051 T-1 a. .--1 • L. m ru M Q_ rn ;� ,--�1 ,�-i 0 N ko N 0 M J Cn -0 c 0 W V) 0 0 U .0 0 L W O U Cn _0 V) M N in M 11 I TE IS � SET T• = US D F�iR �ROSIO Co TROL O L . PERSON ONSITE RESPONSIBLE FOR EROSION CONTROL: STEVE WILSON STEVEN A. WILSON, INC. PHONE # (,317)-846-2555 1 . SEASONAL SOIL PROTECTION CHART STABILIZATION PRACTICE JAN. FEB. MAR. APR. MAY JUN. JUL. AUG. SEPT. OCT. NOV. DEC. PERMANENT A * * * � SEEDING / /��� / /� /�� /// DORMANT B B > SEEDING SEEDING E SODDING F* * * / / / / / / / / / / / / //* > ____ - MULCHING G Seedbed p- Luaration for Permanent Seeding 1. Test soil to determine pH and nutrient levels. (Contact you county SWCD or Cooperative Extension office for assistance and soils information, including available testing services.) . 2. If soil pH is unsuitable for the species to be seeded, apply lime according to test recommendations. . 3. Fertilize as recommended by the soil test. if testing was not done, consider applying - 400 -600 lbs. /acre of 12-12-12. analysis, or equivalent, fertilizer. 4. Till the soil to obtain a uniform seedbed, working the fertilizer and lime into the soil 2 -4 in. deep with a disk or rake operated across the slope. A = KENTUCKY BLUE GRASS 40 lbs. /AC.: CREEPING RED FESCUE 40 lbs. /AC.: PLUS 2 TONS STRAW MULCH /AC. OR ADD ANNUAL RYEGRASS 20lbs > /AC. B = KENTUCKY BLUE GRASS 60 lbs. /AC.: CREEPING RED FESCUE 60 lbs. /AC.: PLUS 2 TONS STRAW MULCH /AC. OR ADD ANNUAL RYEGRASS 30lbs > /AC. C = SPRING OATS 3 BUSHEL /ACRE D = WHEAT OR RYE 2 BUSHEL /ACRE E = ANNUAL RYEGRASS 40 lbs. /AC. (1 lb./1000 sq. ft.) F =SOD G = STRAW MULCH 2 TONS /ACRE - ANCHOR ALL MULCH BY CRIMPING OR TACKIFYING * / //* = IRRIGATION NEEDED DURING JUNE, JULY, AND /OR SEPT. ** = IRRIGATION NEEDED FOR 2 TO 3 WEEKS AFTER APPLYING SOD Rule 5 requires all disturbed areas likely to be idle for 15 day shall have surface stabilization applied. When weather conditions prevent rapid germination of grass, then 2t /ac mulch will be used to ensure ground stabilization requirements are met. Drop Inlet Protection Basket It is the intent of this device to detain water for the purpose of allowing suspended solids 111 the water to settle out before the water enters the storm structure. Soule filtering will occur as water passes through the device. . The bottom of this device is to seal against the flat outer part of the casting. The overall dimension of the basket shall be no smaller than the water inlet perforations in the casting and IIO larger than the outer dimensions of the casting. The height shall be 15" The basket franle shall be welded wire mesh rolled or bent and welded to itself to fit the casting. The wire size shall be no smaller than .149" dia. and openings no larger than IS sq in. It is important that the bottom of the wire franle be Smooth so as not t0 allow any leakage between the basket and casting. The top of the basket shall be open to prevent flooding during heavy storm events. Fabric shall be woven polypropylene allowing 15- 25ga1f1I1111/S(( 111. If 11011-woven fabric is used, the maintenance intervals should be increased to replace silt laden fabric. The fabric shall be attached to the f rame and folded under the bottom to lielp seal against the casting. . This device should be used in conjunction with other Best Nlanagenlent Practices to maximize the efficiency of the erosion control plan. Suppliers for this product include: Lakeside Supply Inc. (317) 281 -2661, Turfgrass Inc (3 17) 894 -3276. CHERRY TREE GROVE A part of the West Half of the Northeast Quarter of Section 22, Township 18 North, Range 4 East, Clay Township, Hamilton County, Indiana, being more particularly described as follows: Commencing at the Southwest corner of the Northwest Quarter of said Northeast Quarter Section; thence North 00 degrees 02 minutes 24 seconds East along the West line of said Half Quarter Section 45.00 feet to the Centerline of Cherry Tree Road and the POINT OF BEGINNING of this description; the next four (4) calls being on and along said Centerline; 1.) North 16 degrees 44 minutes 52 seconds East 52.54 feet; 2.) North 26 degrees 53 minutes 43 seconds East 132.80 feet; 3.) North 35 degrees 34 minutes 19 seconds East 81.80 feet; 4.) North 38 degrees 11 minutes 37 seconds East 102.55 feet to the Southwest corner of the property described in Instrument No. 2001 -36075 in the Office of the Recorder of Hamilton County, Indiana; the next three(3) calls being on and along the South, East and North lines of said real estate; 1.)North 89 degrees 50 minutes 30 seconds East 469.84 feet; 2.)North 01 degrees 00 minutes 12 seconds West 225.57 feet; 3.)South 89 degrees 50 minutes 30 seconds West 288.06 feet to a point on aforesaid Centerline; thence North 36 degrees 53 minutes 48 seconds East along said Centerline 154.16 feet to the Southwest corner of the real estate described in Instrument No.2000 -51124 in said Recorders Office; thence North 89 degrees 50 minutes 30 seconds East along the South line of said Real estate 861.04 feet to the East line of said Half Quarter Section; thence South 00 degrees 04 minutes 03 seconds West along said East line 961.00 feet; thence South 89 degrees 23 minutes 59 seconds West 810.89 feet; thence North 00 degrees 36 minutes 01 seconds West 323.49 feet; thence North 89 degrees 53 minutes 58 seconds West 269.02 feet; thence South 05 degrees 45 minutes 52 seconds West 20.49 feet; thence South 89 degrees 35 minutes 45 seconds West 233.46 feet to the place of beginning, containing 20.442 acres, more or less. FENCE POST (2x2 HARDWOOD POST) . . T SILT FENCE MATERIAL „ 61 -8 ti 3' � tit' FENCE POST SHOULD SILT FENCE MATERIAL SHOULD BE BURIED ;�: t' BELOW BE BURIED 6" BELOW GROUND GROUND SURFACE. SURFACE. SILT FENCE DETAIL NOT -TO -SCALE Exhibit 3,74 -0. SpecIfIcationa Mtiminuins for 5I1t Petme Fantle. Physical proper(( Woven 1'ilbric Non- is,oven fabric itt�riirt ; �:fttir�:i4:rt4:y 5� {�� u Terisilty strength at A A 20To Clongatioll: B 4' Standard strength 30 lbs. /lincar in. .501bs.11incar ill. Extra strength 5113 1bs, /linear in, 70 lbs. /linvar in. Slurry flow rate. 0.3 gal. /min. /sg1t. 4.5 g31. /mill. /sq.ft. Water flow rate 15 e'a1, /11l111' /Sq, fL a 10 gaL /min, /sq,ft. UV re i'stance 7017c1 85% CIIINCRM WAVOU ' DETAL WOVEN -x STAPLE PATTERNS APPLY TO ALL NORTH AMERICAN GREEN EROSION CONTROL BLANKETS. STAPLE PATTERNS WILL VARY DEPENDING UPON SLOPE LENGTH, SLOPE GRADE, SOIL TYPE AND AVERAGE ANNUAL RAINFALL. 300 27 250 225 200 �:_ 175 0 J150 w 125 a_ 100 V) 75 50 25 FT. B C C C C D g A A B B 4:1 3:1 2:1 1:1 LOW MED /HIGH FLOW FLOW CHANNEL CHANNEL AND SLOPE GRADIENT SHORELINE 3' 1 STAPLE 1 -1/2 STAPLES 2 STAPLES � 3.5 STAPLES PER SQ. YD. PER SQ. YD. PER SQ. YD. PER SQ. YD. EROSION CONTROL BLANKET STAPLE PATTERN GUIDE NOT -TO -SCALE 2, -0„ a Q O 0 0 . d 1 � � Q 609 o 5 -0 .. Q DO O I 6�1) Q0 �Q 10' -on a b oQ 00 QZ G) O . 00�° 0�V I ez&iff I O / 5 > -0„ '.* a � O DQ o D �o - V 3' -0" RIP -RAP DETAIL NOT -TO -SCALE Assessment of Construction Plan Elements Al. See Sheets C300 thru C302 A2. See Attachment. A3. Narrative Describing Project Nature and Purpose: This project is Cherry Tree Grove, a residential subdivision. The purpose of this project is for future residential construction. A4. See map included on this sheet. A5. Legal Description of the Project Site: Legal description is shown on this sheet. The latitude is 390- 57' -48" and longitude is 860- 13' -22 ". A6. See Sheet C200 A7. Hydrologic Unit Code: 05120201120080 A8. State or Federal Water Quality Permits: None A90 Specific Points Where Storm water Discharge Will Leave This Site: The storm water will leave the site through the lake outlet pipes to the South of this property into an existing subdivision. See sheet 9200. A10. Location and Name of All Wetlands, Lakes, and Water Courses on And Adjacent to the Site: None A11. Identify All Receiving Waters: This site drains to the South to an existing pipe Al2. Identification of Potential Discharges to Groundwater: None A13. 100 Year Flood plains, Floodways and Floodway Fringes: There are no flood plains, floodways or floodway fringes on this site. A14. Pre - Construction and Post Construction Estimate of Peak Discharge: Pre- Developed: 10 year =14.98 c.f.s. Post- Developed: 10 year = 0.95 c.fs. 100 year = 4.53 c.fs. A15. Adjacent Landuse Including Upstream Watershed: West: agricultural East: woods /residential North: residential South: residential A16. See Sheet C200 A17. Identification of existing vegetative cover: This site is entirely covered by crop residue. A18. See Map & descriptions included on this sheet. A19. See Sheet C200 A20. See Sheets 0500 -0502 and C700 A21. Locations of proposed soil stockpiles, borrow and/or disposal areas: All topsoil is to be relocated to non - building areas. Non - building areas would be considered common areas, rear yards, etc.. Their will be NO borrow areas associated with this project. A22. See Sheet 0100 A23. See Sheet C200 CONSTRUCTION SEQUENCE FOR BUILDING SITE EROSION CONTROL PRACTICES DROP INLET PROTECTION REAR YARD DRAINAGE SWALE I - > o 0 0 0 0, o 0 0 . *..*. . SUBSOIL STOCKPILE SF SF I -A AREA TO BE TOP- \ 0 0 \111W SOILED, SEEDED, ° PS ° TOPSOIL ° AND .MULCHED STOCKPILE BY OWNER AT [6-01 COMPLETION OF CONSTRUCTION. PALIMAR IS TO BE HOUSE GARAGE USED IF GRASS GROWTH IS NOT \ POSSIBLE. :• • . CONSTRUCTION PS ENTRANCE EXIT 0 :.. ° / 0 . .. ° SIDE YARD SF SF DRAINAGE SWALE . STREET SIDE- WALK EXISTING CURB AND GUTTER CURB INLET PROTECTION SEE STORM WATER POLLUTION & PREVENTION NOTES BELOW INDIVIDUAL LOT STORMWATER POLLUTION & PRE\/FN110N DETAIL NOT-TO-SCALE STORM WATER POLLUTION & PREVENTION NOTES: (A) All storm water quality measures, including erosion and sediment control, necessary to comply (b)• with this rule must be implemented in accordance with the plan and sufficient to satisfy subsection (B) Provisions for erosion and sediment control on individual building lots regulated under the original permit of a project site owner must include the following requirements: (1) The individual lot operator, whether owning the property or acting as the agent of the property owner, shall be responsible for erosion and sediment control requirements associated with activities on individual lots. (2) Installation and maintenance of a stable construction site access. (3) Installation and maintenance of appropriate perimeter erosion and sediment control measures prior to land disturbance. (4) Sediment discharge and tracking from each lot must be minimized throughout the lan d disturbing activities on the lot until permanent stabilization has been achieved. (5) Cleanup of sediment must be redistributed or disposed of in a manner that is in compliance with all applicable statutes and rules. (6) Adjacent lots disturbed by and individual lot operator must be repaired and stabilized with temporary or permanent surface stabilization. (7) For individual residential lots, final stabilization meeting the criteria in section 7(b)(20) or this rule will be achieved when the individual lot operator: (A) completes final stabilization; or (B) has installed appropriate erosion and sediment control measures for an individual lot prior to occupation of the home by the homeowner and has informed the homeowner of the requirement for, and benefits of, final stabilization. 7(b)(20) Final stabilization of a project site is achieved when: (A) all land disturbing activities have been completed and a uniform (for example, evenly distributed, without large bare areas) perennial vegetative cover with a density of seventy percent (70 %) has been established on all unpaved areas and areas not covered by permanent structures, or equivalent permanent stabilization measures have been employed; and (B) construction projects on land used for agricultural purposes are returned to its preconstruction agricultural use or disturbed areas, not previously used for agricultural production, such as filter strips and areas that are not being returned to their preconstruction agricultural use, meet the final stabilization requirements in clause (A). Assessment of Storm water Pollution Prevention Plan - Construction Component B1. Description of Potential Pollutant Sources Associated with the Construction Activities: Potential Pollutants during construction includes: Concrete waste water, trash, fossil fuels, oil, grease, paint. Exposure of these pollutants to storm water runoff should be mimized by performing activities such as, equipment storage, refueling, maintenance and port-a -let placement in designated areas as shown on sheet C300. In the event of accidental contamination all efforts should be made to remove contaminants in an appropriate manner. The appropriate Fire Department should be contacted immediately to determine if further measures are needed B2. Sequence Describing Storm water Quality measure Implementation Relative to Land Disturbing Activities: See Construction Sequence on Sheets C300 -C303 B3. Stable Construct on Entrance Locations and Specifications: The construction entrance is shown on sheet C300 along with the details of installation and specification of maintenance on this sheet. B4. Sediment Control Measures for Sheet Flow: The areas of runoff in a sheet flow condition are shown on sheet C300. Silt fence is the primary measure used to eliminate this type of erosion and details are shown on this sheet. B5. Sediment Control Aleasures For Concentrated Flow Areas: The concentrated flow areas are the proposed swales. Erosion control blankets and temporary straw bale dams are proposed for use in these areas. Temporary dams shall be removed once seeding is established. See sheets C300 -C302 for locations. B6. Storm Sewer Inlet Protection Measure Locations and Specifications: Baskets and stone bags are shown to be placed at inlets. Locations are shown on sheet C300 -C301 and details are shown on this sheet. B7. Runoff Control Measures: The lake areas are to be utilized for temporary sediment traps. These are to be constructed as early as possible to speed the removal of sediment (See construction sequence on sheets 0300 - C301). B8. Storm water Outlet Protection Specifications: All end sections of an outlet are shown to be rip - rapped to prevent scour erosion. Rip -Rap is shown on the site development plans and storm water pollution & prevention plans. See detail shown on this sheet and C801. B9. Grade Stabilization Structure Locations and Specifications: Not necessary B10. Location, Dimensions, Specifications and Construction Details of Each Storm water Quality Measure: Each measure is shown on the plans along with the appropriate details and specifications. B11. Temporary Surface Stabilization Methods Appropriate for Each Season: The storm water pollution & prevention plans along with the detail sheet provides different methods and sequences for each measure to be utilized. (See seasonal soil protection chart on this sheet.) B12. Permanent Surface Stabilization Specifications: The permanent stabilization methods are specified on the storm water pollution & prevention plans. The sequencing is specified on this sheet.(See seasonal soil protection chart on this sheet). B13. Material Handling and Spill Prevention Plan: In order to minimize the release of potential pollutants during construction the Contractor shall implement this material handling and spill prevention plan. The Contractor shall review this plan with all subcontractors and require that they implement the plan as well. 1. Construction Equipment a. Fueling, lubrication and fluids: All operations involving the addition of fluids to equipment should be done in one location, as designated on Sheet C300, so that spills are limited to one location on the site, which will facilitate the cleanup Of spills. If an onsite fueling tank is planned to be on site, it shall be double walled and stored in this designated area. This location is an area that will not allow spilled fluids to migrate into subsurface soils. In the event of a spill, the fluid shall immediately be cleaned up by removing the contaminated soil or stone which shall be disposed of in an acceptable manner. Spills on hard surfaces shall be soaked up by an acceptable material such as Oil Dry and the absorbent material disposed of in a proper manner. The spill shall also be reported immediately to the Contractor's superintendent. b. Equipment repair, especially when fluids must be removed from the equipment or the possibility of fluid spills is high, should always be done offsite at a facility that is more suitable than a construction site to handle spills. When equipment must be repaired onsite it should be moved to the maintenance and fueling area if possible. Otherwise, suitable containers should be placed under the equipment during repair to catch any spilled fluids and these fluids should be disposed of in a proper mariner. C. All reusable fluid containers, such as gasoline cans, shall be inspected for leaks each time they are used. If leaks are found, the fluid shall be removed from the container in a proper manner and the container disposed of in an acceptable manner. Empty disposable containers, such as grease tubes and lubricating oil and brake fluid containers, and their packaging, shall be disposed of in a proper manner and shall not be left on the ground or in the open on the construction site. ° ° ° PROPERTY LINE/ DRAINAGE SWALE -�- EXISTING DRAINAGE FINISHED DRAINAGE S TREE CONSERVATION L_(_J . SF SILT FENCING ' GRAVEL ENTRANCE/ . .. . . EXIT PAD .. . .. CURB INLET PROTECTION G�_� DROP INLET PROTECTION SOIL SALVAGE AND UTILIZATION PS PERMANENT SEEDING B13 Cont. 2. Construction Materials and their Packaging a. Erosion control measures shown on these plans shall be implemented prior to and during construction in the proper sequencing to minimize soil erosion. Erosion controls shall be inspected and maintained as described elsewhere in these plans. Excessive dusting of soil on the site shall be minimized by reducing construction traffic across bare soil during dry and/or windy weather, and by applying water or other acceptable dust control measures to the soil. Upon completion of construction and suitable establishment of permanent vegetation, temporary erosion control measures such as silt fence, check dams and inlet protection devices shall be removed in a manner to minimize additional land disturbance. Any areas disturbed by these operations shall be properly revegetated. b. Large waste materials created by cutting, sawing, drilling, or other operations shall be properly disposed of in suitable waste containers. The site shall be checked at the end of the day, as a minimum, and all waste materials, including those blown across or off the site by wind, shall be picked up and disposed of in . suitable containers. Where possible, operations such as sawing that create small particles should be performed in one spot in an area protected from wind, and waste particles collected and disposed of frequently to minimize wind dispersal. Packaging used to transport materials to the site for construction of the facility shall be disposed of properly, whether the material is taken out of its package and incorporated into the project immediately or stored onsite for future use. Packaged materials stored onsite shall be inspected regularly and any loose packaging shall be repaired or disposed of properly. 3. Concrete Waste Water a. All concrete waste water shall be disposed of in the designated area as shown on - Sheet C300. This area is a 4' high, 10' diameter doughnut type mulch berm which shall be constructed over a geotextile fabric. This area shall be inspected on a daily basis as a minimum. When this area becomes full, the pollutants shall be excavated, placed in an acceptable container and disposed of in a proper manner. 4. Paint Products . a. All excess paint and there related products shall be disposed of in the manner at which the manufacturer suggest. Under NO circumstances will paint or their related products be cleaned or disposed of in soil, sanitary sewers, storm sewers or detention basins. Any violation of this shall be reported to the job superintendent. 5. Spill Response In the event of small spills, please contact the construction supervisor. In the event of spills that require removal of soils or other materials, please contact the construction supervisor, developer, County Surveyor's Office and the Local Fire Department. In the event of spills that have potential groundwater or surface water contamination, please contact the construction supervisor, developer, County Surveyor's Office, Local Fire Department, and IDEM. 5. Emergency Numbers: Emergency Response 911 Carmel Fire Department (317) 571 -2600 Carmel Police Department (317) 571 -2545 Indiana Department of Natural Resources (812) 477 -8773 Indiana Department of Environmental Management (317) 233 -7745 Hamilton County Soil and Water (317) 773 -2181 Hamilton County Surveyor (317) 776 -8495 Steven A. Wilson (317) 846 -2555 B14. Monitoring and Maintenance Guidelines for Each Proposed Pollution Prevention Measure: Person in charge of and knowledgeable about erosion and sediment .control shall inspect the site for storm water pollution prevention deficiencies at least daily and again within 24 hours of every 1/2 inch rain event. See Erosion Control Notes on this sheet for specifications. B15. Erosion and Sediment Control Specifications For Individual Building Lots: Construction sequence for individual building lots is shown on this sheet. Storm water Pollution Prevention Plan Post Construction Component C1. Description of Pollutants and Their Sources Associated with the Proposed Land Use: Proposed site will be a single family subdivision. Potential pollutants from this type of development include, but are not limited to: nutrients and pesticides, fluids and debris from parked vehicles & vehicular traffic which could include: fossil fuels, oil, grease, antifreeze, brake fluid, window washer fluid, rubber, plastic, & metal fragments, grit (sediment) from wearing of the road surface, trash (including bacteria and other biological agents contained in the trash) from littering and other types of improper disposal or storage, and elevated receiving water temperatures from storm water runoff contact with impervious surfaces. C2. &C3. Sequence Describing Storm water Quality Measure Implementation: Description of Proposed Post Construction Storm water Quality Measures: The post construction measures used to minimize sedimentation in waterways include swales and a detention pond. The swales will collect runoff from portions of the buildings. The design of the swales will allow sediment to be partially filtered out before storm water enters the designed storm sewer system. Ditch grate inlets will prevent large items from entering the storm pipes and leaving the site. The detention basin which is designed to have water in it at all times, will also help reduce sediment and trash by allowing it to drop . out prior to leaving the site. C4. Location, Dimensions, Specifications and Construction Details of Each Storm water Quality Measures: Catch basins, swales, and lake locations are provided on the site development plans. Details are provided on the Construction Plan Detail sheets. C5. Description of Maintenance Guidelines for Proposed Post Construction Water Quality Measures: Maintenance of all Storm water pollution prevention measures will be the responsibility of the project owner, Steven A. Wilson, Inc. until a point in time in which the Home Owners Association is established. At that point said association shall assume all maintenance responsibilities. The maintenance guidelines consist mostly of good housekeeping measures. Any grassed or vegetated areas that experience erosion from rainfall events should be repaired and revegetated as soon as possible. Trash or litter should be picked up and properly disposed to prevent it from getting into the storm drainage system and downstream waterways. . Erosion of the detention pond banks should be addressed as soon as it becomes visible by filling the eroded area with suitable soil and establishing vegetation immediately, preferably by sodding, or by seeding and mulching and monitoring until suitable vegetation is established. The same measure should be used for steep banks of any earth berm or any other steep area. The detention pond should also be monitored for sediment coming from the storm drainage system. If the bottom of the pond receives sediment, it should be cleaned out and the source found and repaired. The elevation of the pond bottom should be checked every 8 to 10 years and, if significant sediment is encountered, it should be removed from the basin. This should be done during periods of low rainfall to allow soil stirred up by excavation to settle out before a rain event. The detention pond outlet should also be protected by adequate filtration (rip -rap, shown on these plans) to prevent soil from entering the offsite storm drainage system. Pavement areas should also be monitored for pollutants. Any large quantity of fluids such as oil, antifreeze, brake fluid, etc. found on the pavement should be reported to the Home Owner Association and the source determined, if possible, and removed from the site for maintenance or repair. Pavements should also be monitored for sediment coming from vegetated areas that drain onto the pavement. If sediment is found it should be cleaned off the pavement, and the source of the soil found and repaired as discussed above. SOILS MAP . Br Brookston silty clay loam- this soil is dark colored, silty in texture and on depressional u p lands. It is deep po drained with moderate permeability. It has high available water for plant growth and high organic matter o tedntVe It hasrly high water table, high potential frost action, moderate shrink -swell potential, moderate permeability and compact till starting at a depth of 40 to 60 inches. The main soil features that affect the urban development uses are seasonal onded surface w ater. P Because of these engineering limitations this site will be constructed as follows. Cass Estates, being ,a sinl . development within the jurisdiction of The City of Carmel and Hamilton County will have to abide by the currentmily Subdivision Control Ordinance. This ordinance requires that we have an artificially drained site and that the homes within this development be well above the 100yr elevation of the proposed detention basins and therefore be rotected from flooding. All homes will be of slab type construction. in cases where a high water table is present s ecial fo t' shall be constructed All d II VICINITY MAP roa s wi have adequate sub -base. All sanitary sewers shall be public and therefore no Sept systems shall be allowed with 2 to 3 inch stone or mulch. 2 ' 2/ orgaic matter has compact till starting at a depth between 20 -40 inches. The main soil features that affect urban development uses are seasonal high water table, moderate shrink -swell high - (S - 4' _IC - 4' 10' elevation of the proposed detention basins and therefore be protected from flooding. All homes will be of slab type construction. In cases where a high water table is present special footings shall be constructed. All roads will have adequate 3 sub -base. All sanitary sewers shall be public and therefore no septic systems shall be allowed _ (3) 12" MULCH FILLED Mmc2 Miami silt loam, 2 -6 percent slopes- this soil is light colored, silty in texture and on sloping uplands. It is deep and well drained with moderate permeability. It has moderate available water for plant and EROSION CONTROL LOGS growth a medium organic matter content. It has compact till starting at a depth between 20 -40 inches. The main soil features that adversely affect urban development uses are moderate potential frost action, moderate shrink -swell = N W potential, moderately slow permeability, low strength and erosion durin construction. g . .. . . I ... t. - .� •' �� -' ' v '`" ' ....,, 3 1 6" EXCAVATED KEYWAY drain tiles as to help prevent structural shrinking and swelling and low strength. There will be no septic fields in this development. All roads will �ha e adequate sub -base. 6" EXCAVATED KEYWAY 6" MULCH BOTTOM OVER GEOTEXTILE CIIINCRM WAVOU ' DETAL WOVEN -x M_ accumulated sediments after every storm. 4< x x -x-- M ;:�_ I STOCKPILE THE MATERIAL IN ACCESSIBLE LOCATIONS THAT NEITHER INTERFERE WITH OTHER CONSTRUCTION x- -x M O 4' IF SOIL IS STOCKPILED FOR MORE THAN 6 MO., IT SHOULD BE TEMPORARILY SEEDED OR COVERED WITH A TARP OR SURROUNDED BY A SEDIMENT BARRIER. O C) z ­,I- r-, � �- 20 1 I 1/2' 1 -1 z x N x ( q< 4d x REMOVE SEDIMENT WHEN IT ACCUMULATES TO HALF THE DESIGN VOLUME (MARKED BY STAKE) CHECK THE DAM AND ABUTMENTS FOR EROSION, PIPING, AND ROCK DISPLACEMENT, AND REPAIR IMMEDIATELY . IF THE BASIN DOES NOT DRAIN BETWEEN STORMS, REPLACE THE STONE ON 3' � U) THE UPSTREAM FACE OF THE DAM. � O O 00 ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN PERMANENTLY STABILIZED, a. REMOVE WATER AND W W � � � I -____' 6 - x CHECK FOR EROSION DAMAGE AFTER STORM EVENTS AND REPAIR; RESEED AND MULCH IF NECESSARY. TOPDRESS FALL SEEDED WHEAT OR RYE SEEDINGS WITH 50 M 3,x W-Wop AFTER FINISH GRADING INSPECT PERIODICALLY, ESPECIALLY STORM EVENTS, UNTIL THE STAND IS SUCCESSFULLY ESTABLISHED. C.� x x x 00 AB W Lit 0 C IC it 1 x xDx Q X PROBLEMS. (CONTACT YOUR SWCD OR COOPERATIVE EXTENSION OFFICE FOR ASSISTANCE.) X x W z I EROSION CONTROL MATTING IF ANY AREA SHOWS EROSION, PULL BACK THAT PORTION OF THE BLANKET COVERING IT, ADD SOIL, RE -SEED THE AREA, AND RE -LAY AND STAPLE THE BLANKET. x x x J 1 STAPLE 1 -1/2 STAPLES 2 STAPLES � 3.5 STAPLES PER SQ. YD. PER SQ. YD. PER SQ. YD. PER SQ. YD. EROSION CONTROL BLANKET STAPLE PATTERN GUIDE NOT -TO -SCALE 2, -0„ a Q O 0 0 . d 1 � � Q 609 o 5 -0 .. Q DO O I 6�1) Q0 �Q 10' -on a b oQ 00 QZ G) O . 00�° 0�V I ez&iff I O / 5 > -0„ '.* a � O DQ o D �o - V 3' -0" RIP -RAP DETAIL NOT -TO -SCALE Assessment of Construction Plan Elements Al. See Sheets C300 thru C302 A2. See Attachment. A3. Narrative Describing Project Nature and Purpose: This project is Cherry Tree Grove, a residential subdivision. The purpose of this project is for future residential construction. A4. See map included on this sheet. A5. Legal Description of the Project Site: Legal description is shown on this sheet. The latitude is 390- 57' -48" and longitude is 860- 13' -22 ". A6. See Sheet C200 A7. Hydrologic Unit Code: 05120201120080 A8. State or Federal Water Quality Permits: None A90 Specific Points Where Storm water Discharge Will Leave This Site: The storm water will leave the site through the lake outlet pipes to the South of this property into an existing subdivision. See sheet 9200. A10. Location and Name of All Wetlands, Lakes, and Water Courses on And Adjacent to the Site: None A11. Identify All Receiving Waters: This site drains to the South to an existing pipe Al2. Identification of Potential Discharges to Groundwater: None A13. 100 Year Flood plains, Floodways and Floodway Fringes: There are no flood plains, floodways or floodway fringes on this site. A14. Pre - Construction and Post Construction Estimate of Peak Discharge: Pre- Developed: 10 year =14.98 c.f.s. Post- Developed: 10 year = 0.95 c.fs. 100 year = 4.53 c.fs. A15. Adjacent Landuse Including Upstream Watershed: West: agricultural East: woods /residential North: residential South: residential A16. See Sheet C200 A17. Identification of existing vegetative cover: This site is entirely covered by crop residue. A18. See Map & descriptions included on this sheet. A19. See Sheet C200 A20. See Sheets 0500 -0502 and C700 A21. Locations of proposed soil stockpiles, borrow and/or disposal areas: All topsoil is to be relocated to non - building areas. Non - building areas would be considered common areas, rear yards, etc.. Their will be NO borrow areas associated with this project. A22. See Sheet 0100 A23. See Sheet C200 CONSTRUCTION SEQUENCE FOR BUILDING SITE EROSION CONTROL PRACTICES DROP INLET PROTECTION REAR YARD DRAINAGE SWALE I - > o 0 0 0 0, o 0 0 . *..*. . SUBSOIL STOCKPILE SF SF I -A AREA TO BE TOP- \ 0 0 \111W SOILED, SEEDED, ° PS ° TOPSOIL ° AND .MULCHED STOCKPILE BY OWNER AT [6-01 COMPLETION OF CONSTRUCTION. PALIMAR IS TO BE HOUSE GARAGE USED IF GRASS GROWTH IS NOT \ POSSIBLE. :• • . CONSTRUCTION PS ENTRANCE EXIT 0 :.. ° / 0 . .. ° SIDE YARD SF SF DRAINAGE SWALE . STREET SIDE- WALK EXISTING CURB AND GUTTER CURB INLET PROTECTION SEE STORM WATER POLLUTION & PREVENTION NOTES BELOW INDIVIDUAL LOT STORMWATER POLLUTION & PRE\/FN110N DETAIL NOT-TO-SCALE STORM WATER POLLUTION & PREVENTION NOTES: (A) All storm water quality measures, including erosion and sediment control, necessary to comply (b)• with this rule must be implemented in accordance with the plan and sufficient to satisfy subsection (B) Provisions for erosion and sediment control on individual building lots regulated under the original permit of a project site owner must include the following requirements: (1) The individual lot operator, whether owning the property or acting as the agent of the property owner, shall be responsible for erosion and sediment control requirements associated with activities on individual lots. (2) Installation and maintenance of a stable construction site access. (3) Installation and maintenance of appropriate perimeter erosion and sediment control measures prior to land disturbance. (4) Sediment discharge and tracking from each lot must be minimized throughout the lan d disturbing activities on the lot until permanent stabilization has been achieved. (5) Cleanup of sediment must be redistributed or disposed of in a manner that is in compliance with all applicable statutes and rules. (6) Adjacent lots disturbed by and individual lot operator must be repaired and stabilized with temporary or permanent surface stabilization. (7) For individual residential lots, final stabilization meeting the criteria in section 7(b)(20) or this rule will be achieved when the individual lot operator: (A) completes final stabilization; or (B) has installed appropriate erosion and sediment control measures for an individual lot prior to occupation of the home by the homeowner and has informed the homeowner of the requirement for, and benefits of, final stabilization. 7(b)(20) Final stabilization of a project site is achieved when: (A) all land disturbing activities have been completed and a uniform (for example, evenly distributed, without large bare areas) perennial vegetative cover with a density of seventy percent (70 %) has been established on all unpaved areas and areas not covered by permanent structures, or equivalent permanent stabilization measures have been employed; and (B) construction projects on land used for agricultural purposes are returned to its preconstruction agricultural use or disturbed areas, not previously used for agricultural production, such as filter strips and areas that are not being returned to their preconstruction agricultural use, meet the final stabilization requirements in clause (A). Assessment of Storm water Pollution Prevention Plan - Construction Component B1. Description of Potential Pollutant Sources Associated with the Construction Activities: Potential Pollutants during construction includes: Concrete waste water, trash, fossil fuels, oil, grease, paint. Exposure of these pollutants to storm water runoff should be mimized by performing activities such as, equipment storage, refueling, maintenance and port-a -let placement in designated areas as shown on sheet C300. In the event of accidental contamination all efforts should be made to remove contaminants in an appropriate manner. The appropriate Fire Department should be contacted immediately to determine if further measures are needed B2. Sequence Describing Storm water Quality measure Implementation Relative to Land Disturbing Activities: See Construction Sequence on Sheets C300 -C303 B3. Stable Construct on Entrance Locations and Specifications: The construction entrance is shown on sheet C300 along with the details of installation and specification of maintenance on this sheet. B4. Sediment Control Measures for Sheet Flow: The areas of runoff in a sheet flow condition are shown on sheet C300. Silt fence is the primary measure used to eliminate this type of erosion and details are shown on this sheet. B5. Sediment Control Aleasures For Concentrated Flow Areas: The concentrated flow areas are the proposed swales. Erosion control blankets and temporary straw bale dams are proposed for use in these areas. Temporary dams shall be removed once seeding is established. See sheets C300 -C302 for locations. B6. Storm Sewer Inlet Protection Measure Locations and Specifications: Baskets and stone bags are shown to be placed at inlets. Locations are shown on sheet C300 -C301 and details are shown on this sheet. B7. Runoff Control Measures: The lake areas are to be utilized for temporary sediment traps. These are to be constructed as early as possible to speed the removal of sediment (See construction sequence on sheets 0300 - C301). B8. Storm water Outlet Protection Specifications: All end sections of an outlet are shown to be rip - rapped to prevent scour erosion. Rip -Rap is shown on the site development plans and storm water pollution & prevention plans. See detail shown on this sheet and C801. B9. Grade Stabilization Structure Locations and Specifications: Not necessary B10. Location, Dimensions, Specifications and Construction Details of Each Storm water Quality Measure: Each measure is shown on the plans along with the appropriate details and specifications. B11. Temporary Surface Stabilization Methods Appropriate for Each Season: The storm water pollution & prevention plans along with the detail sheet provides different methods and sequences for each measure to be utilized. (See seasonal soil protection chart on this sheet.) B12. Permanent Surface Stabilization Specifications: The permanent stabilization methods are specified on the storm water pollution & prevention plans. The sequencing is specified on this sheet.(See seasonal soil protection chart on this sheet). B13. Material Handling and Spill Prevention Plan: In order to minimize the release of potential pollutants during construction the Contractor shall implement this material handling and spill prevention plan. The Contractor shall review this plan with all subcontractors and require that they implement the plan as well. 1. Construction Equipment a. Fueling, lubrication and fluids: All operations involving the addition of fluids to equipment should be done in one location, as designated on Sheet C300, so that spills are limited to one location on the site, which will facilitate the cleanup Of spills. If an onsite fueling tank is planned to be on site, it shall be double walled and stored in this designated area. This location is an area that will not allow spilled fluids to migrate into subsurface soils. In the event of a spill, the fluid shall immediately be cleaned up by removing the contaminated soil or stone which shall be disposed of in an acceptable manner. Spills on hard surfaces shall be soaked up by an acceptable material such as Oil Dry and the absorbent material disposed of in a proper manner. The spill shall also be reported immediately to the Contractor's superintendent. b. Equipment repair, especially when fluids must be removed from the equipment or the possibility of fluid spills is high, should always be done offsite at a facility that is more suitable than a construction site to handle spills. When equipment must be repaired onsite it should be moved to the maintenance and fueling area if possible. Otherwise, suitable containers should be placed under the equipment during repair to catch any spilled fluids and these fluids should be disposed of in a proper mariner. C. All reusable fluid containers, such as gasoline cans, shall be inspected for leaks each time they are used. If leaks are found, the fluid shall be removed from the container in a proper manner and the container disposed of in an acceptable manner. Empty disposable containers, such as grease tubes and lubricating oil and brake fluid containers, and their packaging, shall be disposed of in a proper manner and shall not be left on the ground or in the open on the construction site. ° ° ° PROPERTY LINE/ DRAINAGE SWALE -�- EXISTING DRAINAGE FINISHED DRAINAGE S TREE CONSERVATION L_(_J . SF SILT FENCING ' GRAVEL ENTRANCE/ . .. . . EXIT PAD .. . .. CURB INLET PROTECTION G�_� DROP INLET PROTECTION SOIL SALVAGE AND UTILIZATION PS PERMANENT SEEDING B13 Cont. 2. Construction Materials and their Packaging a. Erosion control measures shown on these plans shall be implemented prior to and during construction in the proper sequencing to minimize soil erosion. Erosion controls shall be inspected and maintained as described elsewhere in these plans. Excessive dusting of soil on the site shall be minimized by reducing construction traffic across bare soil during dry and/or windy weather, and by applying water or other acceptable dust control measures to the soil. Upon completion of construction and suitable establishment of permanent vegetation, temporary erosion control measures such as silt fence, check dams and inlet protection devices shall be removed in a manner to minimize additional land disturbance. Any areas disturbed by these operations shall be properly revegetated. b. Large waste materials created by cutting, sawing, drilling, or other operations shall be properly disposed of in suitable waste containers. The site shall be checked at the end of the day, as a minimum, and all waste materials, including those blown across or off the site by wind, shall be picked up and disposed of in . suitable containers. Where possible, operations such as sawing that create small particles should be performed in one spot in an area protected from wind, and waste particles collected and disposed of frequently to minimize wind dispersal. Packaging used to transport materials to the site for construction of the facility shall be disposed of properly, whether the material is taken out of its package and incorporated into the project immediately or stored onsite for future use. Packaged materials stored onsite shall be inspected regularly and any loose packaging shall be repaired or disposed of properly. 3. Concrete Waste Water a. All concrete waste water shall be disposed of in the designated area as shown on - Sheet C300. This area is a 4' high, 10' diameter doughnut type mulch berm which shall be constructed over a geotextile fabric. This area shall be inspected on a daily basis as a minimum. When this area becomes full, the pollutants shall be excavated, placed in an acceptable container and disposed of in a proper manner. 4. Paint Products . a. All excess paint and there related products shall be disposed of in the manner at which the manufacturer suggest. Under NO circumstances will paint or their related products be cleaned or disposed of in soil, sanitary sewers, storm sewers or detention basins. Any violation of this shall be reported to the job superintendent. 5. Spill Response In the event of small spills, please contact the construction supervisor. In the event of spills that require removal of soils or other materials, please contact the construction supervisor, developer, County Surveyor's Office and the Local Fire Department. In the event of spills that have potential groundwater or surface water contamination, please contact the construction supervisor, developer, County Surveyor's Office, Local Fire Department, and IDEM. 5. Emergency Numbers: Emergency Response 911 Carmel Fire Department (317) 571 -2600 Carmel Police Department (317) 571 -2545 Indiana Department of Natural Resources (812) 477 -8773 Indiana Department of Environmental Management (317) 233 -7745 Hamilton County Soil and Water (317) 773 -2181 Hamilton County Surveyor (317) 776 -8495 Steven A. Wilson (317) 846 -2555 B14. Monitoring and Maintenance Guidelines for Each Proposed Pollution Prevention Measure: Person in charge of and knowledgeable about erosion and sediment .control shall inspect the site for storm water pollution prevention deficiencies at least daily and again within 24 hours of every 1/2 inch rain event. See Erosion Control Notes on this sheet for specifications. B15. Erosion and Sediment Control Specifications For Individual Building Lots: Construction sequence for individual building lots is shown on this sheet. Storm water Pollution Prevention Plan Post Construction Component C1. Description of Pollutants and Their Sources Associated with the Proposed Land Use: Proposed site will be a single family subdivision. Potential pollutants from this type of development include, but are not limited to: nutrients and pesticides, fluids and debris from parked vehicles & vehicular traffic which could include: fossil fuels, oil, grease, antifreeze, brake fluid, window washer fluid, rubber, plastic, & metal fragments, grit (sediment) from wearing of the road surface, trash (including bacteria and other biological agents contained in the trash) from littering and other types of improper disposal or storage, and elevated receiving water temperatures from storm water runoff contact with impervious surfaces. C2. &C3. Sequence Describing Storm water Quality Measure Implementation: Description of Proposed Post Construction Storm water Quality Measures: The post construction measures used to minimize sedimentation in waterways include swales and a detention pond. The swales will collect runoff from portions of the buildings. The design of the swales will allow sediment to be partially filtered out before storm water enters the designed storm sewer system. Ditch grate inlets will prevent large items from entering the storm pipes and leaving the site. The detention basin which is designed to have water in it at all times, will also help reduce sediment and trash by allowing it to drop . out prior to leaving the site. C4. Location, Dimensions, Specifications and Construction Details of Each Storm water Quality Measures: Catch basins, swales, and lake locations are provided on the site development plans. Details are provided on the Construction Plan Detail sheets. C5. Description of Maintenance Guidelines for Proposed Post Construction Water Quality Measures: Maintenance of all Storm water pollution prevention measures will be the responsibility of the project owner, Steven A. Wilson, Inc. until a point in time in which the Home Owners Association is established. At that point said association shall assume all maintenance responsibilities. The maintenance guidelines consist mostly of good housekeeping measures. Any grassed or vegetated areas that experience erosion from rainfall events should be repaired and revegetated as soon as possible. Trash or litter should be picked up and properly disposed to prevent it from getting into the storm drainage system and downstream waterways. . Erosion of the detention pond banks should be addressed as soon as it becomes visible by filling the eroded area with suitable soil and establishing vegetation immediately, preferably by sodding, or by seeding and mulching and monitoring until suitable vegetation is established. The same measure should be used for steep banks of any earth berm or any other steep area. The detention pond should also be monitored for sediment coming from the storm drainage system. If the bottom of the pond receives sediment, it should be cleaned out and the source found and repaired. The elevation of the pond bottom should be checked every 8 to 10 years and, if significant sediment is encountered, it should be removed from the basin. This should be done during periods of low rainfall to allow soil stirred up by excavation to settle out before a rain event. The detention pond outlet should also be protected by adequate filtration (rip -rap, shown on these plans) to prevent soil from entering the offsite storm drainage system. Pavement areas should also be monitored for pollutants. Any large quantity of fluids such as oil, antifreeze, brake fluid, etc. found on the pavement should be reported to the Home Owner Association and the source determined, if possible, and removed from the site for maintenance or repair. Pavements should also be monitored for sediment coming from vegetated areas that drain onto the pavement. If sediment is found it should be cleaned off the pavement, and the source of the soil found and repaired as discussed above. SOILS MAP . Br Brookston silty clay loam- this soil is dark colored, silty in texture and on depressional u p lands. It is deep po drained with moderate permeability. It has high available water for plant growth and high organic matter o tedntVe It hasrly high water table, high potential frost action, moderate shrink -swell potential, moderate permeability and compact till starting at a depth of 40 to 60 inches. The main soil features that affect the urban development uses are seasonal onded surface w ater. P Because of these engineering limitations this site will be constructed as follows. Cass Estates, being ,a sinl . development within the jurisdiction of The City of Carmel and Hamilton County will have to abide by the currentmily Subdivision Control Ordinance. This ordinance requires that we have an artificially drained site and that the homes within this development be well above the 100yr elevation of the proposed detention basins and therefore be rotected from flooding. All homes will be of slab type construction. in cases where a high water table is present s ecial fo t' shall be constructed All d II VICINITY MAP roa s wi have adequate sub -base. All sanitary sewers shall be public and therefore no Sept systems shall be allowed with 2 to 3 inch stone or mulch. CrA Crosby silt loam, 0 -3 percent slopes- this soil is light colored, silty in texture and on sloping uplands. poorly drained with slow permeability. It has high available water for plant growth and medium dconten d somewhat 2. At a position downslope of the lot and upslope orgaic matter has compact till starting at a depth between 20 -40 inches. The main soil features that affect urban development uses are seasonal high water table, moderate shrink -swell high of the inlet, lay bags tightly in a row curving potential, potential frost action and slow permeability. upslope from curb and away from inlet. Because of these engineering limitations this site will be constructed as follows. Cass Estates, being a single - family development within the jurisdiction of The City of Carmel and Hamilton County will have to by 3. Overlap bags onto the curb and extend amin- abide the current Subdivision Control Ordinance. This ordinance requires that we have an artificially drained site and that the homes within this development be well above the 100yr 10' elevation of the proposed detention basins and therefore be protected from flooding. All homes will be of slab type construction. In cases where a high water table is present special footings shall be constructed. All roads will have adequate DIA. sub -base. All sanitary sewers shall be public and therefore no septic systems shall be allowed _ (3) 12" MULCH FILLED Mmc2 Miami silt loam, 2 -6 percent slopes- this soil is light colored, silty in texture and on sloping uplands. It is deep and well drained with moderate permeability. It has moderate available water for plant and EROSION CONTROL LOGS growth a medium organic matter content. It has compact till starting at a depth between 20 -40 inches. The main soil features that adversely affect urban development uses are moderate potential frost action, moderate shrink -swell = N W potential, moderately slow permeability, low strength and erosion durin construction. g . .. . . I ... t. - .� •' �� -' ' v '`" ' ....,, Because of these engineering limitations this site will be constructed as follows. The foundations and footin s used in this development shall be designed to include foundation g 1 6" EXCAVATED KEYWAY drain tiles as to help prevent structural shrinking and swelling and low strength. There will be no septic fields in this development. All roads will �ha e adequate sub -base. 6" EXCAVATED KEYWAY 6" MULCH BOTTOM OVER GEOTEXTILE CIIINCRM WAVOU ' DETAL WOVEN FABRIC NOT -TO -SCALE accumulated sediments after every storm. 20' -0" MIN. WIDTH 2 " -3" WASHED STONE z (INDOT CA. #2) ° >_ . CONSTRUCTION ENTRANCE DETAIL NOT -TO -SCALE LINE WITH GEOTEXTILE WOVEN FABRIC #53 STONE o� 6' MIN. 3:1 FUELING &VEHICLE MAINTENANCE AREA SECTI ON "Z" -'T' NOT -TO -SCALE Bags overlap onto the curb 1. Fill geotextile bags approximately half full V with 2 to 3 inch stone or mulch. 2. At a position downslope of the lot and upslope /' Runoff of the inlet, lay bags tightly in a row curving -� upslope from curb and away from inlet. 3. Overlap bags onto the curb and extend amin- imum of 3 feet into the street. 000001_,� 4. For additional layers, overlap bags with the Gat between bogs acts as a spillway row beneath, and leave a one -bag gap in the IF FENCE FABRIC TEARS, STARTS TO DECOMPOSE, OR IN ANY WAY BECOMES INEFFECTIVE, REPLACE THE middle of the top row to serve as a spillway. (n 5. Place bags in an arc around curb inlets that o are in a sump position. IS CAUSING THE FABRIC TO BULGE. 6. Set up safety /traffic barriers to keep vehicles TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. from hitting bags, causing possible injury. O N 7. Inspect and repair as needed, and remove any accumulated sediments after every storm. 4< kJo r �'I :J CURB INLET PROTECTION DETAIL NOT -TO -SCALE EROSION CONTROL NOTES ``` `��►lllllt /11& , �i 'S , p • •F -• Q- , G -ft : No. I ..� 10200495 : _ • • 00 -o .00 oft STATE OF = Q ft* �• Ity .,4� SS��NAL EN ``A� lilt i t% %%%" 1 I-1 O CD N 0 Ld E F-- 11� W U J Q H W D o L1.1 � > z UJ p > fy w 0 a ced W I I o ry n >. J O ry 0. I I Q U Q Z Q D Z Z O U Z O Q I 0 __J F- :�i 0 Q U DRAWN BY: CHECKED BY: AAA KRG BKR SHEET N0. S &AJOBNO. 52790S1 M z 0 co w Of Of Q F__ 0 V V) MAINTENANCE PRIOR TO CLEANING AND GRADING INSPECT ENTRANCE PAD AND SEDIMENT DISPOSAL AREA WEEKLY AND AFTER STORM EVENTS OR HEAVY USE. STONE ENTRANCE -� of 0 TOPDRESS WITH CLEAN STONE AS NEEDED. IMMEDIATELY REMOVE MUD AND SEDIMENT TRACKED OR WASHED ONTO PUBLIC ROADS BY BRUSHING OR SWEEPING. FLUSHING SHOULD ONLY BE USED IF THE WATER IS CONVEYED >- SILT FENCE IF FENCE FABRIC TEARS, STARTS TO DECOMPOSE, OR IN ANY WAY BECOMES INEFFECTIVE, REPLACE THE (n UJ � � o �- O-) IS CAUSING THE FABRIC TO BULGE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. O N TOPSOIL STOCKPILE TO OBTAIN A COUNTY SOIL SURVEY REPORT OR CONSULT WITH A SOIL SCIENTIST.) 4< U) I OO M ;:�_ STOCKPILE THE MATERIAL IN ACCESSIBLE LOCATIONS THAT NEITHER INTERFERE WITH OTHER CONSTRUCTION � V M O 00 IF SOIL IS STOCKPILED FOR MORE THAN 6 MO., IT SHOULD BE TEMPORARILY SEEDED OR COVERED WITH A TARP OR SURROUNDED BY A SEDIMENT BARRIER. O C) z ­,I- r-, � �- � I CHECK THE OUTLETS AND MAKE NECESSARY REPAIRS IMMEDIATELY. J z x N q< 4d (/7 a) REMOVE SEDIMENT WHEN IT ACCUMULATES TO HALF THE DESIGN VOLUME (MARKED BY STAKE) CHECK THE DAM AND ABUTMENTS FOR EROSION, PIPING, AND ROCK DISPLACEMENT, AND REPAIR IMMEDIATELY . IF THE BASIN DOES NOT DRAIN BETWEEN STORMS, REPLACE THE STONE ON . 48 � U) THE UPSTREAM FACE OF THE DAM. � O O 00 ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN PERMANENTLY STABILIZED, a. REMOVE WATER AND W W � � � I -____' 6 F-- Z CHECK FOR EROSION DAMAGE AFTER STORM EVENTS AND REPAIR; RESEED AND MULCH IF NECESSARY. TOPDRESS FALL SEEDED WHEAT OR RYE SEEDINGS WITH 50 M Q) W-Wop AFTER FINISH GRADING INSPECT PERIODICALLY, ESPECIALLY STORM EVENTS, UNTIL THE STAND IS SUCCESSFULLY ESTABLISHED. C.� a' 00 UNIFORM DENSITY WITH NURSE PLANTS, LEGUMES, AND GRASSES WELL INTERMIXED; GREEN LEAVES; AND THE W Lit 0 r"- F- 1 ( 'D Q V_ %-__-_� PROBLEMS. (CONTACT YOUR SWCD OR COOPERATIVE EXTENSION OFFICE FOR ASSISTANCE.) W z o EROSION CONTROL MATTING IF ANY AREA SHOWS EROSION, PULL BACK THAT PORTION OF THE BLANKET COVERING IT, ADD SOIL, RE -SEED THE AREA, AND RE -LAY AND STAPLE THE BLANKET. Q. J M 0 � a_ REMOVE SEDIMENT FROM THE POOL AREA TO ENSURE ADEQUATE RUNOFF sTnRAr,E FoR TIDE NcYT RAM' TokmltAo W =) to WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ALL BALES, CONSTRUCTION MATERIAL, AND SEDIMENT AND DISPOSE OF PROPERLY, GRADE THE DISTURBED AREA TO THE ELEVATION OF THE TOP OF THE INLET AND STABILIZE. Q Z INSPECT AFTER EACH STORM EVENT. REMOVE SEDIMENT (BUT NOT BY FLUSHING) WHEN IT REACHES HALF THE HEIGHT OF THE BARRIER. O REMOVAL OF STRAW BALES REMOVAL OF INLET PROTECTION REMOVAL OF SILT FENCE (/) U J Q H W D o L1.1 � > z UJ p > fy w 0 a ced W I I o ry n >. J O ry 0. I I Q U Q Z Q D Z Z O U Z O Q I 0 __J F- :�i 0 Q U DRAWN BY: CHECKED BY: AAA KRG BKR SHEET N0. S &AJOBNO. 52790S1 M z 0 co w Of Of Q F__ 0 EROSION CONTROL MEASURE INSTALLATION SEQUENCE MAINTENANCE PRIOR TO CLEANING AND GRADING INSPECT ENTRANCE PAD AND SEDIMENT DISPOSAL AREA WEEKLY AND AFTER STORM EVENTS OR HEAVY USE. STONE ENTRANCE RESHAPE PAD AS NEEDED FOR DRAINAGE AND RUNOFF CONTROL. TOPDRESS WITH CLEAN STONE AS NEEDED. IMMEDIATELY REMOVE MUD AND SEDIMENT TRACKED OR WASHED ONTO PUBLIC ROADS BY BRUSHING OR SWEEPING. FLUSHING SHOULD ONLY BE USED IF THE WATER IS CONVEYED INTO A SEDIMENT TRAP OR BASIN. REPAIR ANY BROKEN ROAD PAVEMENT IMMEDIATELY. PRIOR TO CLEANING AND GRADING INSPECT THE SILT FENCE PERIODICALLY AND AFTER EACH STORM EVENT. SILT FENCE IF FENCE FABRIC TEARS, STARTS TO DECOMPOSE, OR IN ANY WAY BECOMES INEFFECTIVE, REPLACE THE AFFECTED PORTION IMMEDIATELY. REMOVE DEPOSITED SEDIMENT WHEN IT REACHES HALF THE HEIGHT OF THE FENCE AT ITS LOWEST POINT OR IS CAUSING THE FABRIC TO BULGE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE THE FENCE AND SEDIMENT DEPOSITS, BRING THE DISTURBED AREA TO GRADE, AND STABILIZE. PRIOR TO CLEANING AND GRADING . DETERMINE DEPTH AND SUITABILITY OF TOPSOIL AT THE SITE. (FOR HELP, CONTACT YOUR LOCAL SWCD OFFICE TOPSOIL STOCKPILE TO OBTAIN A COUNTY SOIL SURVEY REPORT OR CONSULT WITH A SOIL SCIENTIST.) PRIOR TO STRIPPING TOPSOIL, INSTALL ANY SITE - SPECIFIC DOWNSLOPE PRACTICES NEEDED TO CONTROL RUNOFF AND SEDIMENTATION. . REMOVE THE SOIL MATERIAL NO DEEPER THAN WHAT THE COUNTY SOIL SURVEY DESCRIBES AS "SURFACE SOIL" (I.E.. A OR AP HORIZON). STOCKPILE THE MATERIAL IN ACCESSIBLE LOCATIONS THAT NEITHER INTERFERE WITH OTHER CONSTRUCTION . ACTIVITIES NOR BLOCK NATURAL DRAINAGE; AND INSTALL SILT FENCES, STRAW BALES, OR OTHER BARRIERS TO TRAP SEDIMENT (SEE EXHIBIT 3.02 -B). (SEVERAL SMALL PILES AROUND THE CONSTRUCTION SITE ARE USUALLY MORE EFFICIENT AND EASIER TO CONTAIN THAN ONE LARGE PILE.) IF SOIL IS STOCKPILED FOR MORE THAN 6 MO., IT SHOULD BE TEMPORARILY SEEDED OR COVERED WITH A TARP OR SURROUNDED BY A SEDIMENT BARRIER. TEMPORARY DIVERSIONS AFTER ROUGH GRADING INSPECT WEEKLY AND FOLLOWING EACH STORM EVENT. REMOVE SEDIMENT FROM THE CHANNEL AND REINFORCE THE RIDGE AS NEEDED. CHECK THE OUTLETS AND MAKE NECESSARY REPAIRS IMMEDIATELY. REMOVE SEDIMENT FROM TRAPS WHEN THEY ARE 50% FULL. WHEN THE WORK AREA HAS BEEN STABILIZED, REMOVE THE RIDGE, FILL THE CHANNEL TO BLEND WITH THE NATURAL GROUND, REMOVE TEMPORARY SLOPE DRAINS, AND STABILIZE ALL DISTURBED AREAS. AFTER ROUGH GRADING INSPECT THE ROCK DAM AND BASIN FOLLOWING EACH STORM EVENT. ROCK DAM REMOVE SEDIMENT WHEN IT ACCUMULATES TO HALF THE DESIGN VOLUME (MARKED BY STAKE) CHECK THE DAM AND ABUTMENTS FOR EROSION, PIPING, AND ROCK DISPLACEMENT, AND REPAIR IMMEDIATELY . IF THE BASIN DOES NOT DRAIN BETWEEN STORMS, REPLACE THE STONE ON THE UPSTREAM FACE OF DAM IF THE BASIN DRAINS TO RAPIDLY FOLLOWING A STORM,(LESS THAN 6 HRS.), ADD INDOT CA NO. 5 GRAVEL ON THE UPSTREAM FACE OF THE DAM. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN PERMANENTLY STABILIZED, a. REMOVE WATER AND SEDIMENT FROM THE BASIN. b. REMOVE THE DAM, DISPOSING OF THE ROCK IN DESIGNATED DISPOSAL AREAS. c. SMOOTH THE SITE TO BLEND THE SURROUNDING AREA. d. STABILIZE AFTER ROUGH GRADING INSPECT PERIODICALLY AFTER PLANTING TO SEE THAT VEGETATIVE STANDS ARE ADEQUATELY ESTABLISHED; RE- E TEMPORARY SEEDING SEED IF NECESSARY. CHECK FOR EROSION DAMAGE AFTER STORM EVENTS AND REPAIR; RESEED AND MULCH IF NECESSARY. TOPDRESS FALL SEEDED WHEAT OR RYE SEEDINGS WITH 50 LBS. /ACRE OF NITROGEN IN FEBRUARY OR MARCH IF NITROGEN DEFICIENCY IS APPARENT. (EXHIBIT 3.11 -8 SHOWS ONLY WHEAT /RYE FALL SEEDED.) PERMANENT SEEDING AFTER FINISH GRADING INSPECT PERIODICALLY, ESPECIALLY STORM EVENTS, UNTIL THE STAND IS SUCCESSFULLY ESTABLISHED. (CHARACTERISTICS OF A SUCCESSFUL STAND INCLUDE: VIGOROUS DARK GREEN OR BLUISH -GREEN SEEDLINGS; UNIFORM DENSITY WITH NURSE PLANTS, LEGUMES, AND GRASSES WELL INTERMIXED; GREEN LEAVES; AND THE PERENNIALS REMAINING GREEN THROUGHOUT THE SUMMER, AT LEAST AT THE PLANT BASE.) PLAN TO ADD FERTILIZER THE FOLLOWING SEASON ACCORDING TO SOIL TEST RECOMMENDATIONS. REPAIR DAMAGED, BARE, OR SPARSE OR PATCHY, BY FILLING ANY GULLIES, RE- FERTILIZING, OVER - OR RE- SEEDING AND MULCHING AFTER RE- PREPARING THE SEEDBED. IF VEGETATION FAILS TO GROW, CONSIDER SOIL TESTING TO DETERMINE ACIDITY OR NUTRIENT DEFICIENCY PROBLEMS. (CONTACT YOUR SWCD OR COOPERATIVE EXTENSION OFFICE FOR ASSISTANCE.) IF ADDITIONAL FERTILIZATION IS NEEDED TO GET A SATISFACTORY STAND, DO SO ACCORDING TO SOIL TEST RECOMMENDATIONS. AFTER FINISH GRADING DURING VEGETATIVE ESTABLISHMENT, INSPECT AFTER STORM EVENTS FOR ANY EROSION BELOW THE BLANKET. EROSION CONTROL MATTING IF ANY AREA SHOWS EROSION, PULL BACK THAT PORTION OF THE BLANKET COVERING IT, ADD SOIL, RE -SEED THE AREA, AND RE -LAY AND STAPLE THE BLANKET. AFTER VEGETATIVE ESTABLISHMENT, CHECK THE TREATED AREA PERIODICALLY. AFTER FINISH GRADING INSPECT THE DROP INLET PROTECTION AFTER EACH STORM EVENT, AND MAKE NEEDED REPAIRS IMMEDIATELY. STRAW BALES REMOVE SEDIMENT FROM THE POOL AREA TO ENSURE ADEQUATE RUNOFF sTnRAr,E FoR TIDE NcYT RAM' TokmltAo CARE To NOT DAMAGE OR UNDERCUT THE BALES. WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ALL BALES, CONSTRUCTION MATERIAL, AND SEDIMENT AND DISPOSE OF PROPERLY, GRADE THE DISTURBED AREA TO THE ELEVATION OF THE TOP OF THE INLET AND STABILIZE. INLET PROTECTION AFTER EACH INLET IN PLACED INSPECT FREQUENTLY FOR DAMAGE BY VEHICULAR TRAFFIC, AND REPAIR IF NEEDED. INSPECT AFTER EACH STORM EVENT. REMOVE SEDIMENT (BUT NOT BY FLUSHING) WHEN IT REACHES HALF THE HEIGHT OF THE BARRIER. DEPOSIT REMOVED SEDIMENT WHERE IT WILL NOT ENTER STORM DRAINS. AFTER ALL AREAS DRAINING TO THESE AREAS N/A ARE STABILIZED AFTER ALL AREAS DRAINING TO THESE AREAS N/A ARE STABILIZED . AFTER ALL AREAS DRAINING TO THESE AREAS N/A ARE STABILIZED REMOVAL OF STRAW BALES REMOVAL OF INLET PROTECTION REMOVAL OF SILT FENCE J Q H W D o L1.1 � > z UJ p > fy w 0 a ced W I I o ry n >. J O ry 0. I I Q U Q Z Q D Z Z O U Z O Q I 0 __J F- :�i 0 Q U DRAWN BY: CHECKED BY: AAA KRG BKR SHEET N0. S &AJOBNO. 52790S1 M z 0 co w Of Of Q F__ 0 BEGIN CONSTRUCTION STA. 0 +00 L affi cv a N 0 0 ko N 0 cD J Cn .a a 0 CL Cid a a) cn °O d- i O O d1 Ln X33 790 00 0 Q 0 U 780 D z O z 0) 0 to DATUM ELEV M 00 775.00 0-+ LOW POINT ELEV = 804.91 LOW POINT STA = 1+00.47 PVI STA = 1+05.84 PVI ELEV = 804.83 A. D. = 1.71 K = 23.39 POIN�NT T�O�F TANGENCY . ........... , ""ftft-ftft STA. 1 +88.11 CURVE DATA o= 57•20'50' POINT OF T R=1 50.00' STA. 4+55.03 L= 150.73' T= 82.03' ok INTERSECTION STA. 4 +77.01 � 33 32 P INT O CURVATURE /STA. 7 +78.41 30 � INTERSECTION � STA. 8 +60.03 wm"'� HIGH POINT ELEV = 806.02 HIGH POINT STA = 2 +26.68 PVI STA = 2 +35.23 PVI ELEV 806.23 A. D. _ -3.04 K = 19.77 SCALE• 1"= 50' H OR x 1°0 2 NCI � �--- � - - - -�- �-� lk� - Cn � 0 2.0 11E15.86 SMICKLE LANE W Cn D.CHG. L.P. I +00 0 +50` 1 +00 1 +50 °- °- 2 +06.38 0 ate Cn Cn 0 0) 0 0 0 0 v 1° 0 v cn 0 v 00 r I� IN 19 CURVE DATA D= 92424'09•• R= 150.00' I L= 241.91' T= 156.43' \ zi J ��� POINT OF TANGENCY TA*. 20957 I i i i L MiniHwHi Cover for Pipe Crossings of City Streets For installation of Storm Mains, Water Mains, Sanitary Mains, Water Service Laterals, Sanitary Service Laterals under City streets, regardless of the jurisdiction of the utility, the minimum cover from the top of the installed pavement to the top of the installed pipe shall be the pavement section thickness (all bituminous and aggregate material above the subgrade) plus 1 -0 ". If the standard practice of the utility that has jurisdiction over the installation has a more stringent cover requirement, the more stringent requirement shall govern LOW POINT .ELEV = 791.29 LOW POINT STA = 10 +20.49 PVI STA = 10 +07.30 PVI ELEV = 791.17 A. D. = 2.55 HIGH POINT ELEV = 792.03 HIGH POINT STA = 11+53.41 PVI STA = 11+83.58 PVI ELEV = 792.24 A. D. = -4.91 END CONSTRUCTION STA. 13+25.71 SCALE: 1 °= 50' LOW POINT ELEV = 787.13 LOW POINT STA = 13 +37.21 PVI STA = 13 +07.31 PVI ELEV = 786.91 A. D. = 4.93 POINT OF CURVATURE STA. 2 +62.37 40.00 POINT OF CURVATURE Q °xoo � 0,�9 � TA. +37.98 vc CURVE DATA "< � V! _ o =1 1 o•z2'S9„ R= 100.00' `� � W � 3� s +oo m� \ L= 192.65' A � 0.0 � � l 143.84' � --- - KEIL DRI,VEo �PBa>> 203 0 0 - +o0 4 _J LOW POINT ELEV = 804.91 LOW POINT STA = 1+00.47 PVI STA = 1+05.84 PVI ELEV = 804.83 A. D. = 1.71 K = 23.39 POIN�NT T�O�F TANGENCY . ........... , ""ftft-ftft STA. 1 +88.11 CURVE DATA o= 57•20'50' POINT OF T R=1 50.00' STA. 4+55.03 L= 150.73' T= 82.03' ok INTERSECTION STA. 4 +77.01 � 33 32 P INT O CURVATURE /STA. 7 +78.41 30 � INTERSECTION � STA. 8 +60.03 wm"'� HIGH POINT ELEV = 806.02 HIGH POINT STA = 2 +26.68 PVI STA = 2 +35.23 PVI ELEV 806.23 A. D. _ -3.04 K = 19.77 SCALE• 1"= 50' H OR x 1°0 2 NCI � �--- � - - - -�- �-� lk� - Cn � 0 2.0 11E15.86 SMICKLE LANE W Cn D.CHG. L.P. I +00 0 +50` 1 +00 1 +50 °- °- 2 +06.38 0 ate Cn Cn 0 0) 0 0 0 0 v 1° 0 v cn 0 v 00 r I� IN 19 CURVE DATA D= 92424'09•• R= 150.00' I L= 241.91' T= 156.43' \ zi J ��� POINT OF TANGENCY TA*. 20957 I i i i L MiniHwHi Cover for Pipe Crossings of City Streets For installation of Storm Mains, Water Mains, Sanitary Mains, Water Service Laterals, Sanitary Service Laterals under City streets, regardless of the jurisdiction of the utility, the minimum cover from the top of the installed pavement to the top of the installed pipe shall be the pavement section thickness (all bituminous and aggregate material above the subgrade) plus 1 -0 ". If the standard practice of the utility that has jurisdiction over the installation has a more stringent cover requirement, the more stringent requirement shall govern LOW POINT .ELEV = 791.29 LOW POINT STA = 10 +20.49 PVI STA = 10 +07.30 PVI ELEV = 791.17 A. D. = 2.55 HIGH POINT ELEV = 792.03 HIGH POINT STA = 11+53.41 PVI STA = 11+83.58 PVI ELEV = 792.24 A. D. = -4.91 END CONSTRUCTION STA. 13+25.71 SCALE: 1 °= 50' LOW POINT ELEV = 787.13 LOW POINT STA = 13 +37.21 PVI STA = 13 +07.31 PVI ELEV = 786.91 A. D. = 4.93 z O (n Li Q Q 0 Y- %%% 0. R I NEy '�4 .r Nos 10200495: -o STATE OF O w\ ,v '�'�•,SS/6NAL �� ��•``. O \ N 0 w w U O Ld CN c� > o O cv) N Lr) CD Q z + Cn _J V) X CIA C�8 s � 0. V) O° Ln 00 W w Ln a� I z rn (D -4- L_ u 00 LL- W w o ,° W z O M 0 W c) Z O up) U Q Z 40.00 vc Q 60.0o vc V! " 1 =5 � VERT. W Z � w O � > z 0 0 0 _J K = 19.58 SCALE: 1"=50' HOR. W K = 16.29 K = 16.23 `° w + w W = Q � U z a � U U) Z 000 J W C) Z 00 w 50.00' vc b �_ � 1 5 VERT. V � b So.00' vc ' S &A JOB NO. 52790S1 80.00 ' VC 15 R.C.P. E O N I N V. = 7.40 00 + C11 _ J O 00 M O + (p 00 0-) 00 Lr) O O O t C N _ 00 00 r� II II O � o Lo N o 00 O N 0 `- � ± Lo (� > II I + 00 + 00 w 0 � N + N .- rn CO I- LLJ w Q O w w > (n U U ] w U U > W (� Uj U + N O t� _ r- (� - U) U ] > w > m rn U > > ryN `- � U > 0_ > m m W W w U m CM a- > w w (n > U w EXIS ING GRADE w , 12" .C.P.N 0 1 ftftft INV.= 01.05 PROPOSED RADE ° 15 " C.P. E� V N V. 797.40 PRO OSED GRADE 0.60 - 1 R.C. . E " WATEF LINE o 9 V. = 788 77 _ 0.62% 00 O � r� EXI TING GRADE--`0' 0, � N co � � O 00 r- + rn 00 ° co 8" D.R. . 3 P.V.C. 00 + N ° + N '� + r- INV.= 784.81 N N Q Q ° r- Q 0 �- Ln ¢ F- ~ (n + Q 36" R C. P. N Q �-- + Q » 12 R. ".P. N � w w °° c INV.= 81.29 �- U) I =7 3.72 Q F- F- ~' >- U D Q F___ w Q w . :2 U) > Q z W �' Q U U D ~Q I- U) U U z W Q Z w z U_ z O Q U F- o C) F Q ULU w w L'- U w F- U U w U F- LJ c(0 w� O F- N Ln p F- O 0 F- v7 O) N co U) W� L'- ° LL_ LL O cn cj� � O w O .� Q L6 Z � z Z F- O F- N �- F- >< o00 O c� o_ o°o w° o°o a°. o°0 ° 00 ° 00 0) rn Z 0 Z O 0) Z N O� : z, rn 0) z� O 00 z 000 � � �� a- � �C4r` 0_ F- �� rn 00 O . O 00 u7 00 , ., N ,.., O OD o0 cfl d- I .._. O� 00 ;. mot- O O _ N O : ; .: F , cfl u7 (� O 00 u7 O F.: 0 r- " co 00 O cD 00 Ln LL) -....- Ln %...:- tf) _. •.,..:'..._ 114 lO In to _ �_... n._ O O ,. _: : - . = - ° '> �/� ._; N - � N (� • N 00 d- r7 • • • • - - ....: O O 00 O = 00 „. -: O 00 :.. >.,� O 00 -.tee O 00 = .� =,:,J O 00 O 00 O - 00 O . 00 O 00 00 O 00 00 00 00 00 _ Op 00 : y (� y _ , 1 ` - .. .� . _ �J _ W d' Q� 1 O� O� , , r.. _. N a.. . -- �- .- r- `= r- a7 • - - • 00 00 00 00 a0 - 00 00 00 00 -00 0 +50 1+00 1+50 2 +00 2 +50 3 +00 3 +50 4 +00 4 +50 5 +00 5 +50 6 +00 6 +50 7 +00 7 +50 8 +00 8 +50 9 +00 9 +50 10 +00 10 +50 11+00 11+50 12 +00 12 +50 13 +00 13 +50 z O (n Li Q Q 0 Y- %%% 0. R I NEy '�4 .r Nos 10200495: -o STATE OF O w\ ,v '�'�•,SS/6NAL �� ��•``. O \ N 0 w w U O Ld CN c� > o O cv) N Lr) CD Q z + Cn _J V) X CIA C�8 s � 0. V) O° Ln 00 W w Ln a� I z rn (D -4- L_ u 00 LL- W w o ,° W z O M 0 W c) Z O up) U Q Z Q D Z V! ~ W Z � w O � > z 0 0 0 _J C�d W W Q `° w + w W = Q � U z a � U U) Z 000 J W C) Z 00 w Q�_ Q U b DRAWN BY: AA KRG CHECKED BY: BKR V � b SHEET N0. ' S &A JOB NO. 52790S1 ri rl L [O CL O ri O O N N O co J "O tom.. O L cz Q� L 1 O llqr V i cn O rn N Ln m rl ri _L- 0 fu G a 0 0 0 N kO N m 0 9 0 -a a� a� U C C W I N O d" V 0 0 rn n N Ln i ml ,--1 L cyl Ln A! 1 ` 0 0 N ko N 0 9 cm i Q� 0 {0 V f` C H M O U cm "0 i (n O n N Ln a z5� I 1 I \ I HAN ICA RAMP TO BINSTALLED 795.62 1+75 795.95 795.62 J� �I II I I �I �I II I 50' W I I 30' -B J J J + co (0 �� [COD on O O J 1 J O Un J N J N � cD J J 07 �N��,I, I J O I I I O +D °� m O 1 II II SCALE: 1 "= 20' I I - - *HANDICAP RAMP TO BE INSTALLED �_ � -� � .8 1. � 1 � � 42 � 790.39 790.12 + ° -' - - �- 791.68 rn < 791.56 12 +25 KEIL DRIVE 12 +00 12 +1a.5s - H.P. P.C. P.T. 11 +83.58 790.72 790.45 0 0 11 +25 11 +45.6 4 11 +53.41 11+60.89 11 +77.2 791 75 791 36 791.85 790.12 o� 791.89 792.01 792.03 792.01 790.39 791.42 791.03 E� 791.68 791.70 791.68 791.52 - - 791.56 i - - 790.8 790.45 5 791.75 791.76 792.03 792.01 7 1.8 Jam_ - i i - 789.05 0 12 +50 - � 789.38 789.05 _. _- i i - - f� in z O w D! Y D% Q w Q D P IST O :TL No. = 14200495 -o STATE OF DIAV 6NAL r` c� N W_ Li. C� W U U Z ry o V) LJ > o Cif o Ln cV � Q 0 Q r,0 O 00 z - � 00 < 0 U) o w w z � Ln � �> z w o �° � C Q ^W z o 0 L...1.. W N O z � o � U w _j > a o 0 w 0 w w w U � Z ~ Q � Z W W = U z Q 0 z 0 0 W N� Q U DRAWN BY: CHECKED BY: AA KRG BKR SHEET NO. C 03 S &AJOBNO. 52790S1 L a 0 0 0 N l0 N ,-i 0 J C a c rn a� au L 0 d' c, "0 i O On n N m LEGEND STOP STOP SIGN [25] 25 M.P.H. SIGN STREET NAME SIGN 000 END ROADWAY MARKERS SCALE: 1 "= 50' NOTE: ALL TRAFFIC CONTROL SIGNS ARE INSTALLED BY THE CITY AND REQUIRE AN ORDINANCE. NOTE: ALL TRAFFIC MAINTENANCE MUST BE IN COMPLIANCE WITH THE INDIANA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (M.U.T.C.D.). z 0 V) Ld Y Q Lil Q 0 p R I NE/,/ �•,�� ;•�'��Q� 1STE,q •�T G'�; No. 10200495 STATE OF ' Q pr • �NDIANP '���. " "f ` 6NAL I',- 0 0 N D W_ LL_ W U U � Z o C Cn > o o � N I Q NO CD U o Z 0') V) J z V) °° x N O O LL_ qo LLJ LLJ -p Q7 � Li 1..� 0 - Z W 0 FO � U Q W Z o o LL.j C%1 0 O ~ U -i W Q U DRAWN BY: CHECKED BY: AA KRG BKR SHEET N0. C405 S &A JOB NO. 52790S1 Q z Q 0 z Z z D 0 Q W J > z 0_ n p .j (D Q 0 W ~ w Z � o �- U U_ ry F � r LL. LLJ Q ry U I— -i W Q U DRAWN BY: CHECKED BY: AA KRG BKR SHEET N0. C405 S &A JOB NO. 52790S1 0 Q W S Q Z: oz r SHEET NO. C U F Q p M 52790S1 (Y S W 00 to � Q Q LLj OZw Q Z zw �W z \ UO000f OVO Q— _j_ Q �_ O v w Za ozw z Jw M� a Z w w O lid 00 F- Q >:: 00z (n Z U 00 s in 0Z ~ Z i ZYw c� J ,. r_n V I Q U) L `) r < u- 500' cr Z �w Z 500' 500' 500' 00 El 171 a 00 1:1 El a SCALE: 1 "= 30' LEGEND O FLAGMAN A FLAGMAN AHEAD SIGN ❑ ROAD CONSTRUCTION AHEAD SIGN /END CONSTRUCTION SIGN o DRUMS 4 �1 �Y EAST SIDE OF CHERRY TREE ROAD 13 DRUMS w/"STEADY BURNING LIGHTS" ® 25' 0 —C= 300' MOBILE OPERATION ON A TWO —LANE ROAD USING FLAGGERS (TRAVELING 3 MPH OR LESS OR MOBILE OPERATIONS -15 MINUTES OR LESS) NOTES: 1. THE DISTANCE BETWEEN ROAD WORK AHEAD SIGNS SHOULD NOT EXCEED APPROXIMATELY 2 MILES. 2. WHERE FEASIBLE, WELL DEFINED END POINTS (E.G. INTERSECTIONS, MAJOR DRIVEWAYS, CITY LIMITS, ECT.) SHOULD BE USED TO ESTABLISH THE LIMITS OF THE WORK ZONE. 3. FLAGGER WARNING SIGNS SHOULD BE REPOSITIONED PERIODICALLY AS THE OPERATION MOVES. 4. IF THERE IS A SIDEROAD INTERSECTION WITHIN THE WORK AREA, ADDITIONAL TRAFFIC CONTROL, SUCH AS FLAGGERS AND APPROPRIATE SIGNAGE, MAY BE NEEDED ON THE SIDEROAD APPROACHES. 5. ADDITIONAL PROTECTION VEHICLES TO WARN AND REDUCE THE SPEED OF ONCOMING OR OPPOSING TRAFFIC MAY BE USED. POLICE PATROL CARS MAY BE USED FOR THIS PURPOSE. 11*0 a El El 00 a El El 00 NOTE.- ALL TRAFFIC MAINTENANCE MUST BE IN COMPLIANCE WITH THE INDIANA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (M. U. T. C. D.). >_ im z 0 W cr- I Y Q W F- Q ```�II11111111 /I,II'' Q- : 1STE% "o... No. 10200495 -o STATE OF ACS, ' G� SZONAL �� `.``��� �II/I1111111111" ' rl- CHECKED BY: BKR SHEET NO. C P. S &A JOB NO. 52790S1 Q N W_ W LL S Q F- W U Za U V) r O Z Z Q Lj cr p0 Q W S = D F M U Q w Q (n F� c1i > o Z W cr Z �w Z Wo ZLJ zcno 0ZW u ,4r N Q M 0� w U w Qw J U0w U� ) i - -- q Z �w m�a Ww Qo Oz _.. _. O� p � W z o ,J,• v O C� z z 2Y w cn OZ • to 00� cd U) C)f LL_ Lr) o oo iEz 500' 500' 500' 0.0: z w 500' °° 4 �1 �Y EAST SIDE OF CHERRY TREE ROAD 13 DRUMS w/"STEADY BURNING LIGHTS" ® 25' 0 —C= 300' MOBILE OPERATION ON A TWO —LANE ROAD USING FLAGGERS (TRAVELING 3 MPH OR LESS OR MOBILE OPERATIONS -15 MINUTES OR LESS) NOTES: 1. THE DISTANCE BETWEEN ROAD WORK AHEAD SIGNS SHOULD NOT EXCEED APPROXIMATELY 2 MILES. 2. WHERE FEASIBLE, WELL DEFINED END POINTS (E.G. INTERSECTIONS, MAJOR DRIVEWAYS, CITY LIMITS, ECT.) SHOULD BE USED TO ESTABLISH THE LIMITS OF THE WORK ZONE. 3. FLAGGER WARNING SIGNS SHOULD BE REPOSITIONED PERIODICALLY AS THE OPERATION MOVES. 4. IF THERE IS A SIDEROAD INTERSECTION WITHIN THE WORK AREA, ADDITIONAL TRAFFIC CONTROL, SUCH AS FLAGGERS AND APPROPRIATE SIGNAGE, MAY BE NEEDED ON THE SIDEROAD APPROACHES. 5. ADDITIONAL PROTECTION VEHICLES TO WARN AND REDUCE THE SPEED OF ONCOMING OR OPPOSING TRAFFIC MAY BE USED. POLICE PATROL CARS MAY BE USED FOR THIS PURPOSE. 11*0 a El El 00 a El El 00 NOTE.- ALL TRAFFIC MAINTENANCE MUST BE IN COMPLIANCE WITH THE INDIANA MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (M. U. T. C. D.). >_ im z 0 W cr- I Y Q W F- Q ```�II11111111 /I,II'' Q- : 1STE% "o... No. 10200495 -o STATE OF ACS, ' G� SZONAL �� `.``��� �II/I1111111111" ' rl- CHECKED BY: BKR SHEET NO. C 05 S &A JOB NO. 52790S1 N W_ LL F- W U U v) Z O c1i > o N � o 0 ro ° 0- r- U O z Q x N Q L cd U) C)f LL_ Lr) o oo iEz W W L 0.0: z w - �> o °° LL_ uj Z z Q" o W p U � z Q w U ry Z Q Z W f— Z Q U Q f— W O Of 0 w w ry ry ry W 2 U Q z Q 0 z z 0 U 0 J Q C DRAWN BY: AAA /KRG CHECKED BY: BKR SHEET NO. C 05 S &A JOB NO. 52790S1 L a Ln N 0 N rIN 0 0 N N 9 _; 3. 0 CL Q9 Q a 0 V rn 0 n N Ln Zi 1) General A) The work subject to the requirements of this policy shall include the production, hauling/delivery, spreading, finishing, compaction and other work necessary to prepare foundations, install aggregate bases and install one or more courses of base, intermediate, or surface hot mix asphalt mixtures within existing or proposed right -of -way for roadways, auxiliary lanes and asphalt multi -use paths. B)This policy shall be the basis for acceptance of the work by the City. Failure to adhere to the requirements of this policy may result in non - acceptance of the work or other remedies outlined in this policy. C) Workmanship, materials and quality of the work completed shall conform to the 2006 Standard Specifications of the Indiana Department of Transportation (hereinafter referred to as Standard Specifications), except where deviations are allowed herein, or variances are granted. D) Where the minimum standards of any other governmental agency having concurrent jurisdiction exceed these standards, the higher standards shall apply. E) If any plan or other note or specification on the approved construction documents exceeds the minimum standards of this policy, the higher standards shall apply. F) Nothing contained herein shall be construed as prohibiting the design and construction of improvements meeting higher standards, nor as discouraging petitions to appropriate governing bodies for variances for alternatives which can be supported by advances in technology and are approved by other agencies with concurrent jurisdiction. G) All work shall comply with the requirements of Section 105.03 of the Standard Specifications. H) For the purposes of this policy, where the term Engineer is used in this policy and the Standard Specifications, it shall mean: a) The Carmel City Engineer, staff of the Department of Engineering, other personnel employed by the City of Carmel, or authorized agent(s) that may be retained to represent the City of Carmel. ii) The Hamilton County Highway Engineer, staff of the Hamilton County Highway Department, other personnel employed by Hamilton County, or authorized agent(s) that may be retained to represent Hamilton County Highway, depending on the location of the work. I) Authority of the Engineer over the work shall be per Section 105.01 of the Standard Specifications. J) Prior to commencing the work, the Contractor performing the work shall contact the Engineer to schedule a pre - construction meeting to review the Engineer's construction requirements, staff notification requirements, required inspections for certain stages of the work and to review the authority of the Engineer as it relates to the work. K) Under no circumstances shall work subject to the standards established by this policy commence without obtaining approved construction drawings by the City of Carmel Department of Engineering. 2) Foundation A) General i) This work shall consist of the construction/preparation of the foundation in accordance with Section 105.03 of the Standard Specifications. B)Excavation and Embankment i) Prior to beginning excavation and embankment operations, all necessary clearing, grubbing, scalping and topsoil stripping and subsequent backfilling for removed items within the slope stake limits shall be performed in accordance with Section 201.03 and 201.04 of the Standard Specifications. All topsoil, vegetation, roots, stumps, friable and deleterious material shall be completely removed within the limits of the slope stakes. ii) Excavations (1) After excavation operations, all spongy and yielding material that does not readily compact shall be removed from within the slope stake limits and the resulting void shall be refilled with suitable material and compacted in accordance with Section 203 of the Standard Specifications. (2) Any pronounced depressions within the slope stake limits resulting after excavation operations shall be refilled with suitable material and compacted in accordance with Section 203 of the Standard Specifications. lll) Embankments (1) Embankments shall be constructed in accordance with Section 203 of the Standard Specifications. (2) All spongy and yielding material that does not readily compact shall be removed from within the slope stake limits prior to embankment operations. (3) Any pronounced depressions within the slope stake limits resulting after clearing, grubbing, scalping and topsoil removal shall be refilled with suitable material and compacted in accordance with Section 203 of the Standard Specifications prior to embankment operations. (4) Prior to the construction of any embankment, the original ground surface within the limits of the slope stakes shall be leveled and the upper 6- inches shall be compacted in accordance with Section 203 of the Standard Specifications. (5) Embankments shall be shaped to be well drained and shall be protected to prevent erosion. (6) Loose depth of each embankment lift, final compacted depth, compaction method and compaction requirements shall be in accordance with Section 203 of the Standard Specifications. A) Soil Subgrades i) Subgrades shall be prepared only after the installation of all utilities and subsurface drains indicated on the approved construction documents to be located under the pavement are completed. Trench backfilling work of these installations shall be in accordance with the City of Carmel Trench Backfilling specifications. ii) The subgrade shall be shaped to the required grade and sections, free from all ruts, corrugations, or other irregularities. iii) The subgrade shall be uniformly prepared, compacted and approved in accordance with Sections 207.02, 207.03 and 207.04 of the Standard Specifications. iv) Subgrades shall be inspected and approved by the Engineer before any aggregate base or hot mix asphalt pavements are constructed. A proofroll shall be conducted in accordance with Section 203.26 of the Standard Specifications. Unacceptable areas shall be corrected to the satisfaction of the Engineer before any aggregate base or hot mix asphalt paving operations commence. v) At the discretion of the Engineer, Subgrade that has satisfactorily passed a proofroll, but remains uncovered for a period of 14 calendar days prior to placing stone or is subject to a measurable rain event prior to placing stone, shall be subject to additional proof rolls prior to placement of the Aggregate Base. A) Existing Pavement i) Milling of existing pavement surfaces shall be in accordance with Section 306.02, 306.03, 306.05, 306.07 and 306.08 of the Standard Specifications. ii) Localized weak areas of the existing pavement section uncovered during the milling process shall be repaired in accordance with Section 304.02, 304.035 304.05 or 305 of the Standard Specifications. iii) Prior to opening milled areas to traffic, the milled areas shall be cleaned of all material, debris and dust resulting from the operation. iv) Milled areas that remain open to traffic longer than those times stipulated in Section 306.05 of the Standard Specifications shall be subject to liquidated damages outlined in Section 306.05 of the Standard Specifications. The Contractor shall be responsible for payment of these liquidated damages. 2) Aggregate Bases A) General i) This work shall consist of placing a compacted aggregate on a prepared soil subgrade in accordance with Section 105.03 of the Standard Specifications. ii) Aggregate Base materials shall be in accordance with Section 301.02 of the Standard Specifications. iii) The material shall be obtained from a Certified Aggregate Producer in accordance with Section 917 of the Standard Specifications. iv) The Aggregate Base material shall be handled and transported to, and on, the work site in a manner that minimizes segregation and moisture loss. v) Aggregate Bases shall be constructed on prepared foundations and to thicknesses equal or greater than those indicated on the approved construction documents. B)Temperature and Seasonal Limitations i) The Aggregate Base shall be placed in accordance with the temperature limitations of Section 301.04 of the Standard Specifications. ii) Frozen material shall not be placed. iii) Aggregate Bases must be placed and pass proof roll prior to November 30 in order to allow paving in accordance with Section 4C(iv) of this policy. C)Preparation i) The prepared foundation shall be free from objectionable or foreign materials at the time of placement. ii) The subgrade shall be subject to additional proof rolls in accordance with Section 203.26 of the Standard Specifications just prior to placing the Aggregate Base on the subgrade in accordance with Section 2C(v) of this policy. Unacceptable areas shall be corrected to the satisfaction of the Engineer before any Aggregate Base is placed. D) Spreading and Finishing i) The Aggregate Base shall be spread in accordance with Section 301.05 of the Standard Specifications. ii) The Aggregate Base shall be compacted in accordance with Section 301.06 of the Standard Specifications. iii) Subsequent paving courses shall be placed over the Aggregate Base within 14 calendar days. Aggregate Bases that lay exposed for a period of time greater than 14 calendar days or experience a measurable rain event prior to the placement of subsequent paving courses shall be subject to inspection and acceptance by the Engineer. At the discretion of the Engineer, additional proof rolls may be required. 3) Asphalt Pavement A) General i) This work shall consist of placing one or more courses of base, intermediate, or surface hot mix asphalt (HMA) mixtures on a prepared foundation in accordance with Section 105.03 of the Standard Specifications. ii) HMA base, intermediate, or surface mixtures shall be constructed on prepared foundations and to thicknesses equal or greater than those indicated on the approved construction documents. iii) Materials used in the production of the HMA mixtures shall be in accordance with Section 401.03 of the Standard Specifications. iv) Equipment for HMA operations, including but not limited to production, hauling/transportation, laydown, compaction and miscellaneous /ancillary activity shall be in accordance with Section 409 of the Standard Specifications. v) Installation of the full pavement section indicated on the approved construction documents for the entire area to be paved must be completed in the same paving season. vi) Widening operations shall comply with the following: (1) The outside face of the excavated area shall be left as nearly vertical as the nature of the material will permit and not wider than the outside limits of the widening section. (2) The existing pavement adjacent to the widening area shall be sawcut to a clean edge. (3) The subgrade in the widened area shall be compacted in accordance with this policy. (4) Widening mixtures shall comply with the pavement section indicated on the approved construction documents. (5) Compaction of the widening shall be in accordance with Section 304.05 of the Standard Specifications. A) Preparation i) The Aggregate Base shall be subject to additional proof rolls in accordance with Section 203.26 of the Standard Specifications just prior to placing the HMA courses in accordance with Section 3D(iii) of this policy. Unacceptable areas shall be corrected to the satisfaction of the Engineer before any paving operations commence. ii) All displacement or rutting of the Aggregate Base shall be repaired prior to placing HMA mixtures. iii) Milled asphalt surfaces shall be tacked in accordance with Section 406 of the Standard Specifications. iv) Asphalt surfaces between courses shall be tacked in accordance with Section 406 of the Standard Specifications. v) Contact surfaces of curbing, gutters, manholes, and other structures shall be tacked in accordance with Section 406 of the Standard Specifications. vi) Surfaces on which a mixture is placed shall be free from objectionable or foreign materials at the time of placement. vii) Tack Coat material shall be distributed with equipment meeting the requirements of Section 409.03(a) of the Standard Specifications. B) Weather and Seasonal Limitations i) HMA courses shall be placed when the ambient temperature and the temperature of the surface on which it is to be placed is 45 °F (7 °C) or above. The Engineer shall determine the ambient temperature. There shall be no provision for low temperature compaction allowed by Section 402.16 of the Standard Specifications. ii) No mixture shall be placed on a frozen subgrade. iii) Under no circumstances shall HMA mixtures be placed between December 15 and March 30. iv) If a foundation that is to receive one or more courses of base, intermediate, or surface HMA mixtures is placed and determined to be an approved foundation by the City prior to November 30, placement of HMA courses will be allowed up to December 15, provided that the ambient and foundation surface temperature complies with the requirements of Section 4C(i) of this policy and the paving contractor pay for the services of a full time construction inspector and who shall act as an authorized agent of the Engineer. The Engineer shall select the construction inspector. v) If the ambient and foundation surface temperature complies with the requirements of Section 4C(i) of this policy between April 1 and April 15, HMA course shall be allowed to be placed on an approved foundation provided that the paving contractor pay for the services of a full time construction inspector and who shall act as an authorized agent of the Engineer. The Engineer shall select the construction inspector. vi) The Engineer reserves the right to suspend all paving operations if, in the opinion of the Engineer, that prevailing weather conditions and/or the condition of the Subgrade and /or the Aggregate Base may result in substandard HMA placement, spreading and finishing. C) Spreading and Finishing i) HMA courses shall be placed upon an approved foundation or other HMA course by means of laydown equipment in accordance with Section 409.03(c) of the Standard Specifications. ii) Segregation or flushing or bleeding of HMA mixtures will not be permitted. Corrective action shall be taken to prevent continuation of these conditions. Segregated or flushed or bleeding HMA mixtures shall be removed if directed. iii) All areas showing an excess or deficiency of binder shall be removed and replaced. iv) All HMA mixtures that become loose and broken, mixed with dirt, or is in any way defective shall be removed and replaced. D) Joints i) Joints shall conform to the requirements of Section 401.15 of the Standard Specifications. E) Compaction i) The HMA mixture shall be compacted with equipment in accordance with Section 409.03(d) of the Standard Specifications immediately after the mixture has been spread and finished. ii) Rollers shall not cause undue displacement, cracking, or shoving. 2) Inspections A) All materials furnished and each part or detail of the work will be subject to inspection per Section 105.10 of the Standard Specifications for the purpose of ascertaining that the work is in substantial conformance with this policy and the approved construction documents. B)The Contractor shall notify the Engineer a minimum of 48 -hours in advance of commencing any work subject to the standards established by this policy. C)The Contractor shall schedule proofrolls with the Engineer a minimum of 48 -hours in advance of such proofrolls. D) Sampling and testing of materials, equipment or construction work may be required at the expense of the Contractor at the discretion of the Engineer for the purpose of ascertaining that the work is in substantial conformance with this policy and the approved construction documents. Sampling and testing shall conform to the requirements of the sections of the Standard Specifications applicable to the portion of the work suspected to be non - compliant or as directed by the Engineer. E) Where the Engineer determines that is necessary to confirm compliance with standards of quality or thickness, pavements shall be cored and tested at the expense of the Contractor. The average thicknesses of all courses must equal or exceed the minimum prescribed by the approved construction documents, and no single core shall show a deficiency greater than one half inch (1 /2 ") in any course or total thickness from the pavement section indicated on the approved construction documents. F) Such inspections shall not be construed to relieve the developers' engineers or contractors in any way from their obligations and responsibilities under their contracts. Specifically, inspection by the Engineer, or by retained engineers or testing agencies, shall not require them to assume responsibilities for the approved construction documents, for any misinterpretation of the approved construction documents by the contractors during construction, or for the means and methods of construction, nor for safety on the job site. G) Work identified to not meet the requirements of this policy or the approved construction documents, unacceptable work, whether the result of poor workmanship, use of defective materials, damage through carelessness, or any other cause found to exist prior to the final acceptance of the work, shall be removed immediately and replaced in an acceptable manner at the Contractor's expense. H) If the Contractor fails to comply forthwith with any order made under the provisions of this subsection, the Engineer will have authority to cause unacceptable work to be remedied or removed and replaced; to cause unauthorized work to be removed; and to deduct the costs from any monies due or to become due. I) Work done contrary to instructions provided by the Engineer shall be considered unacceptable and subject to immediate removal and replacement in accordance with the instructions provided by the Engineer. 3) Acceptance A) Before acceptance of any phase of construction, the Engineer shall determine if the improvements are in substantial compliance with this policy (except for any variances granted) and the approved construction documents B)The Engineer may, at his sole discretion, accept work that is not in conformance with this policy provided that the work is bonded for a period greater than three years. The Engineer shall establish the extended bonding requirement. (1) 1 V) Z 0 V) w Y Q' Q w Q 0 �•` p R I NEly G1STE,q No. 10200495 _= -o STATE OF ` "................. •...........• G� I 8 /6NAL 0 N 0 w Li 0 V � Z o V) > Q � - o V Z O rC� � V I Q � Qf w z w J � W z CL J Wc=5 O zo ~ V) U i-n N 0 0 N 0 P4-) 00 0 CD U 0 Ln LO L0 Of 00 CDo -� 0 Q_ 00 N 0 0 00 0 w U DRAWN BY: CHECKED BY: BKR I BKR SHEET NO. C406 S &AJOBNO. 52790S1 z Q 0 z w 0 > z 0 0 _J .J V 0 LLJ a. w Q:� CD F- z > >_ Q Of Of w U w U DRAWN BY: CHECKED BY: BKR I BKR SHEET NO. C406 S &AJOBNO. 52790S1 L a N N 66 0 N n 0 0 N to N 0 J I o _0 vi a� 0 a Cd a cv c ca 6 0 Ln i rn 0 N Ln I m STA. 5 +99 � / I 25' B.L. 0 MANHOLE 410 / 2 12 L.F. . -6" STA. 1+98 WYE & LAT. / G z OF LOT STA. 0 +97 / �'�� CL O 10 T.P.E. \ \�o, v� ` &S.S� I > 2 D.U� LJ &s 403 — MANHOLE 412 \ \ SF ` / 20' U. &S.S.E. — _� 5' B.L. I �o o \ \ / S 50 ___ 5 STA. 0 +79 I &s \ / 25' B.L. STA. 10 +29 I E\ agMANHOLE 40L o STA. 8 +53 10 SANITARY 12 11 17 L.F. - 6" / / 13 L.F. -6" 14 L.F. -6" WYE & LAT. I WATER I LATERAL 16 27 J 22 \ 15 L.F. -6" WYE & LAT. WYE & LAT. STA. 0 +67 LATERAL 12 L.F. -6 /LZ; 15 L.F. -6" WYE & LAT. STA. 9 +63 STA. 0 +14 I 5' 5' 5' I WYE & LAT. m WYE & LAT. \ STA. 8 +83 � I STA. 0 +95 N L o 30• STA. 4 +92 \ �`- •' SANITARY LINE ' < 0 50' W - �N MANHOLE 402 _ 20 _ — — - — — STA. 5 +14 p E _ — — S.S.D. o 24' D E' LATERAL • • -- - - - - -- - - S.S.D. - - - -- ,,i • - - - .�`� S p• R INE& -II I I Ln moo\ `• ��; .•'99�• •, 26 ( a\ �s' 23 I S.S.D. o: = No. 82 L.F. -6' - - - - - -- ------ - - - - -- WYE & LAT. �S`s\ 'C 50 L.F. -6" _ I WYE &LAT. STA. 4 +27 F` STA. 4 +14 ••• ••. v v v WATERLINE v 1000495 0 I 15 D.U. &S.E. I �� ••• ..• " .a �: \ ••• ••• � STATE OF Q TYPICAL UTIUTY O �N P • ='• �i DIAN 15' D.U. &S.E ••. LATERAL PLACEMENT %,�c�ss�•• ..... •'NG��.` I � • 40' RAO 15' D.U. &S.E �, so• 15' D.U. &S.E. ••• a 24 C" ,✓ . I 63 25_6 \ 9G 44 L.F. -6" " WYE &LAT. WYE & LAT. I r's, �� STA. 3 +30 I �' ' • I STA. 3 +28 � \ / 71 0 \ ••• I MANHOLE 400 co I STA. 1+82 ` •.• ... u• •• •.. •.• •.• _ N MANHOLE 401 ••• � o I STA. 2 +84 20' T.P.E• SCALE: 1 "= 50' U cry Z o w lv > o CD { Q 0 RE CD � Q CO RY z NER ( C!1 � ST �� 6g ( z EX� S-� AT ES I Q 48 ICD Go o Cki LnC)f `� CO NO w w u7 z or- CIO: z - w o J c- Q w z o i3 Minimum Cover or Pipe Crossings of City Streets �'" � 0') O f � �' NOTE: THERE ARE TO B NO WATER VALVES OR MANHOLES For installation of Storm Mains, Water Mains, Sanitary Mains, Water Service Laterals, Sanitary Service w U, Laterals under City streets, regardless of the jurisdiction of the utility, the minimum cover from the top of the Q WITHIN THE PAVEMENT, CURBS, OR S installed pavement to the top of the installed pipe shall be the pavement section thickness (all bituminous and O U aggregate material above the subgrade) plus 1 -0 ". If the standard practice of the utility that has jurisdiction V) over the installation has a more stringent cover requirement, the more stringent requirement shall govern 13 UU 0- OW p Ld _ c) 0 0 o O O o Q 0000 �NO� q- 4- O J IQ— O�O ��O �N- � Z = O c6 W 00 r7 W 00 In U W a0 W L0 4 J+ N W+ N Q C) z +o0 J+ rn J+ 0) w - CD O cp � O aO � » s -J o M Or, 1 o=� o=N 1 5 o=� _ �1 _ �1 SCALE: 1 =50 HOR. _`- � QC_j zQU Z Q U O zQ zQU Q�C3 » , zQ z x� Q� QF- <-� Q� 1 =5 VERT. <�- - 800 w 0 � 0 ~ � cn f-= �_ [n F--: � 07 cn F r n J V l.l-J z aO _ o > o w z a- EXIS TING GRADE o O ~ - J PROPOSED GRADE 0 18., R.C.P. NW GRANULAR _ Q INV.= 701.07, BACKFILL 790 - _....._ _ W _....._._._.___...,,,,y.. GRANULAR - BA FILL 42% _ - OS L.F. (--' 0,42% 8" SDR 35 P.V.C. i ! 203 L.F. 0.42% 8" SDR 35 P.V.C. 784. n 783.63 783.73 ONCRETE 0.42% 8" SDR 35 P.V.C. RADLE 136 L.F. 78 .78 z 8" SDR 35 P.V.C. 782.58 8" WATERLINE — 230 L.F 0.42% 782.01 = 1" R.C.P.[ 781.91 V.= 782.6' ry 0.42% 8" SDR 35 P.V.C. U 182 L.F. 780.32 780 780.12 W 7. 15" R.C.P. NW J EX. 8" S.D.R. 35 P.V.C. 102 L.F. O INV.= 778.57 INV.= 779.35 N 0.42% 36" R.C.P. NE U INV.= 776.61 CONTRACTOR SHALL VERIFY INVERT 8" SDR 35 P.V.C. "HOLEY MOLEY" Z PRIOR TO CONSTRUCTION SAYS: CAUTION Q ® LOCATION OF ALL EXISTING UNDERGROUND U) UTILITIES SHOWN ON THIS PLAN ARE BASED -� UPON ABOVE GROUND EVIDENCE. (including, W but not limited to, manholes, inlets, valves, & :E marks made upon the ground by others.) AND ct� ARE SPECULATIVE IN NATURE. THERE MAY ALSO Q - BE OTHER EXISITING UNDERGROUND UTILIITIES U FOR WHICH THERE IS NO ABOVE GROUND p EVIDENCE OR FOR WHICH NO ABOVE GROUND DRAWN BY: CHECKED BY: EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS AAA K R G B K R 13 1-800-3(92-5544 OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR SHEET N0. • CALL TOLL FREE PRIOR TO ANY AND ALL CONSTRUCTION. 1- 800 - 428 -5200 500 FOR CALLS OUTSIDE OF INDIANA s & A JOB No. 52790S1 ,--1 L CL �r M N n 0 0 N l�0 N ,-i O J Cn vi O L a Cd a co 'c M ILn 0 in U Cn 0 rn N L M, 1 1 Li Cri I� 0 in 0N O W± N 0 0 D o O r4-) N �.� 1 Minimum Cover for Pipe Crossings of City Streets For installation of Storm Mains, Water Mains, Sanitary Mains, Water Service Laterals, Sanitary Service Laterals under City streets, regardless of the jurisdiction of the utility, the minimum cover +J- 'om the top of the installed pavement to the top of the installed pipe shall be the pavement section thickness (all bituminous and aggregate material above the subgrade) plus 1 -0 ". If the standard practice of the utility that has jurisdiction 6" over the installation has a more stringent cover requirement, the more stringent requirement shall govern AT 17 r- O Ln O � cD 00 boo 800 790 DATUM ELEV 780.00 1A /VC D. I A T Cn O L C 0 U L L_ 0 L� I Ui 4I o. A i O It O UJ004 �Ln�0 0017- SCALE: 1 " =50' HOR. 0MCo Q�� 1"=-R' VF'RT : Q "HOLEY MOLEY" SAYS: NOTE.- THERE ARE TO BE NO WATER VALVES OR MANHOLES WITHIN \ THE PAVEMENT, N CURBS, 0 Li OR SIDEWALK. LL 1- 800 - 382 -5544 CALL TOLL FREE 1 - 800 - 428 -5200 FOR CALLS OUTSIDE OF INDIANA SCALE: 1 "= 50' OF LOT I SANITARY WATER I LATERAL LATERAL [5'[ 5' 5' SANITARY LINE ' S.S.D. LATERAL _ - � - S. S. D. S.S.D. ' WATERLINE TYPICAL UTILITY LATERAL PLACEMENT M U) Z O M W Q_' Y D' Q w Q Sp,RINEly ' Q, FO = No. 1000495 �`• STATE OF 0,, 1NDIANP ., •••........ •••'�C �. �•,SSAONAL EN .`,. 1j111111111\1 \ \`` ' 0 \ N 0 Li LL w U U � Z (D i� � o � CD M Lr) N 00 ro _Q U ° 00 V) Q � L Q) L>_ do �0 `U) o FEw w z z _ °° _ U-11 o C7 Q �= o W to O o ~ C) U W J O > � O ry 0 � W Z w Q ry ry J ~ Q W - U Z CAUTION Q z Q z z 0 U O __J Q Z LOCATION OF ALL EXISTING UNDERGROUND v / UTILITIES SHOWN ON THIS PLAN ARE BASED J UPON ABOVE GROUND EVIDENCE. (including, LLJ but not limited to, manholes, inlets, valves, & marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO Q BE OTHER EXISITING UNDERGROUND UTILIITIES U FOR WHICH THERE IS NO ABOVE GROUND DRAWN BY: CHECKED BY: EVIDENCE OR FOR WHICH NO ABOVE GROUND AAA K R G B K R EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHEET NO. SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. C501 S &A JOB NO. I 52790S1 TA ,-i = .(o C� L a N N Ln N O O N ILO N O J N _O O a aS c a �v N O Ln U i rn O rn n N L m cv f cv a 0 Ln Ln 0 N N 0 M rn _0 a� 0 L a 06 C cn a E 0 cn °o c0 U -0 V) O 01 N Ln i M "X 790 DATUM ELEV 775.40 f i f Storm SewMinhnum Cover for Pipe CYOSSilzgs of .City Streets For installation of Storm Mains, Water Mains, Sanitary Mains, Water Service Laterals, Sanitary Service Laterals under City streets, regardless of the jurisdiction of the utility, the minimum cover from the top of the installed pavement to the top of the installed pipe shall be the pavement section thickness (all bituminous and aggregate material above the subgrade) plus 1 -0 ". If the standard practice of the utility that has jurisdiction over the installation has a more stringent cover requirement, the more stringent requirement shall govern ., • L J I I 5 r:. NOTE,* ALL CASTINGS SHALL BE LABELED "DUMP NO W TO WATERWAY ". o No Mo N4 0 PROPOSED GRADE z+ f L0 0 0 1 " =5' VERT, 0 5" ORIFICE N.P.�= 776.50 ° 0 z WO°O W + 0 ��N RCN +`� J +`� F- o wr--O z +� SCALE: 1"=50' ,- O O wT-(0 jr-CD HOR* ? +° z° W o w�0 z +� N F- d' O z�� ��� U� II. I oN� w » � 1 =5 W + +° mm�� M�� VERT. I( Q II f {L_ Z +00 zoQ ozQU ozQ Cr Q 1= D�Q � ° W m .I(, m II CAUTION >- U) z o U � � Q V) �- U) s C) D --. 0U) 0U)F- PROPOSED GRADE w 89.45 o w z 789.3 but not limited to, manholes, inlets, valves, & 0f w J GRANULAR BA 0 8' S.D.R. 35 P.V.C. > O I J W _J co �F FOR WHICH THERE IS NO ABOVE GROUND Y EXISTING GRADE �- 6 ° 'w -J z � I � 30 L. F. ' PROPOSED GRADE 0.30% Cn U) Ln 15" R.C.P w w z „ M � � Ld > U •> 00 LJ W 7071 o BKR _ O o � ' C600 W z FULL DEPTH J w J 6. _ FULL DEPTH = SQ GRANULAR BACKFILL Y GRANULAR BACKFILL 27" R.C.P. N .8 .._S.D.R. 35 P.V.C. c� O 8" WATERLINE INV.= 786.78 N I 785 V.= .35T " :�.._.- _.�._._�__ Q - y . CONCRETE FULL DEPTH IF _ 36" R.C.P. I CRADLE 21 R.C.P. GRANULAR 6, 140 L.F. 0.307o . 8" S. D. R. 35 P. V. C. 782.45 783.57 INV.= 783.56 �� 7 82.54 782.64 783.06 783.16 783.47 _783.66 781.83 781.93 782.35 Z 781.44 00 15" R.C.P. N 8" WATERLINE 8" WATER INE INV.= 783.16 Z78'.34 781.2 102 L.F. 31 L.F. N. P. = 776.50 776.50 776.64 0.30% 0.30% 21" R. '� 12 R.C.P. 6 9 L. F. 30 L.F. 0.20% 0.30% 30 L.F. 36" R.C.P. 6" R. C. P 0.30% 2" R.C.P 79C 800 790 00 O O N O z w000 WHO W't� WOO Z+� _J ';t J�(D z N M z+ SCALE: 1"=50' HOR. �� 0 0 I I M _ 11 m_ I I A » r- 790 780 770 in QcD >_ O 00 ° c� 00 z 000 X JQU W z (/) 1- w _U O �o C) x U WO J 3: CO Q o �_ I `L_ ON ° SCALE.- 1 " =50' HOR. �cr:XQw » > ��N ;W 1 =5 VERT. EXISTING GRADE O SCALE.- 1= 50 HOR. -J "'4- Li to LO PROPOSED GRADE z+ f z+ 1 " =5' VERT, 5" ORIFICE N.P.�= 776.50 776.23 776.5 0 Cf) 81 L. F. 0.33% 12" R.C.P. C o U W M N LAKE 6" 94" NTl RIP NEENAH R -4833 OR EQUAL � N (0 N O SCALE.- 1= 50 HOR. -J "'4- Li to LO O Lq n z+ f z+ 1 " =5' VERT, D!Q �Q U 0 Cf) D� 0 U) 800 790 n I 800 790 0 F_- O LLJ wW+ c1f C'() CD U zoQ Ozi- ♦ _ SCALE: 1 "= 50' �CKFILL 780 800 CO Q J 0 z z C o U W M N > 0 DATUM ELEV 760.00 O O w I- Q f {L_ I CI J W 1= -' Q EXISTING GRADE W CAUTION z LOCATION OF ALL EXISTING .UNDERGROUND UTILITIES SHOWN ON THIS PLAN s C) U) PROPOSED GRADE 89.45 o UPON ABOVE GROUND EVIDENCE. (including, 789.3 but not limited to, manholes, inlets, valves, & FULL DEPTH w KFILL GRANULAR BA 0 8' S.D.R. 35 P.V.C. > INV.- 782.98 73 co �F FOR WHICH THERE IS NO ABOVE GROUND • 30 z Q �- 6 ° 'w -J z � I � 30 L. F. ' X 0.30% Cn U) Ln 15" R.C.P w w z �CKFILL 780 800 p.RINE& ` •••••.........•• ei �` Q�• •' C�1STFiq ••'••.• i '�• ' G F40 . • Now 102Q0495 -0 % STATE OF .= � �O �•,,�� TONAL 0 CO Q z Q 0 z z C o _1 W M N > �7 DATUM ELEV 760.00 O O w Q f {L_ I v W 1= W CAUTION z LOCATION OF ALL EXISTING .UNDERGROUND UTILITIES SHOWN ON THIS PLAN s C) U) ARE BASED _ o UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & rO V / w marks made upon the ground by others.) AND > CO M co FOR WHICH THERE IS NO ABOVE GROUND C:) z Q �- 'w -J z � I � LLJ :�i U X cidOf Cn U) Ln CD CD w w z „ M � � DC U •> 00 LJ W z w o BKR _ O � � Q C600 W z o 0') J = SQ Q 0 p.RINE& ` •••••.........•• ei �` Q�• •' C�1STFiq ••'••.• i '�• ' G F40 . • Now 102Q0495 -0 % STATE OF .= � �O �•,,�� TONAL 0 CO Q z Q 0 z z C o _1 W U N > �7 DATUM ELEV 760.00 O O w Q f {L_ I v W 1= W CAUTION U LOCATION OF ALL EXISTING .UNDERGROUND UTILITIES SHOWN ON THIS PLAN s C) U) ARE BASED _ o UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & w marks made upon the ground by others.) AND CD C CO M co FOR WHICH THERE IS NO ABOVE GROUND C:) z Q �- V) -J z � I � LLJ :�i U X cidOf Cn U) Ln CD CD w w z „ M � � DC U •> 00 LJ W z w o BKR _ O � � Q C600 W z o 0') J = W cn O z �. o � U Aso CO Q z Q 0 z z W o _1 W U � > �7 DATUM ELEV 760.00 O O � -I Q (D I v W S &A JOB NO. 5279051 CO CAUTION LOCATION OF ALL EXISTING .UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND -J EVIDENCE WAS OBSERVED. THE EXACT LOCATION LLJ :�i OF SAID EXISTING UNDERGROUND UTILITIES ct� SHOULD BE VERIFIED BY THE CONTRACTOR Q PRIOR TO ANY AND ALL CONSTRUCTION. U DRAWN BY: CHECKED BY: AA KRG BKR SHEET NO. C600 S &A JOB NO. 5279051 L ..a �O a n �o Ln 0 N N 0 M J 0) -v v's a� 0 a dS a E 0 cn 0 V 't7 U) O Cn N L M 810 IT11 790 / � J 7.7 D� Storm SewMininunn Cover for Pipe Crossings of City Streets For installation of Storm Mains, Water Mains, Sanitary Mains, Water Service N 0 TE : ALL CASTINGS SHALL BE LABELED Laterals, Sanitary Service Laterals under City streets, regardless of the jurisdiction " D U M P N 0 WASTE - DRAINS TO WA TE R WA Y�� , of the utility, the minimum cover from the top of the installed pavement to the top of the installed pipe shall be the pavement section thickness all himminr,,,s, and aggregate material above the sub rade )p lus 1 -0 ". If the standard practice of the utility that has jurisdiction over the installation has a more stringent cover • g requirement, the more stringent requirement shall govern - s i -- 10 P. E. N N N N U N O O CN- _ O F- 0 JON J WO � 0 L j0000 00 j� -0 0 ~c�J O O WLo0 WcflO Z +C6 O O CD Z +O X00 o ? +O �00 m ��. Z+0 '�t m SCALE.* 1"=50' HOR. z +,t - -CV0 J00N -�LnCN Z +O Z +O �- °° °° �Q . �Q U cn f- 0 cn J0 Z +O o,� . Q��? >_ n�- . ��� 0 n�- . 1 ��� » > 1 =5 VERT, o . �� Qa� .- �Q� ofQ �� 5�" Z + °Q 11 W z +G) -N� UM JAL �Q. U �-cn� �c�n� �� � .11 Q�-" VERT. W Y _ m�� mn� Z +Q, o Q� . � cn i-- C*14 U' Q�� >-- (n l- CD N L0 W - PROPOSED GRADE UPON ABOVE GROUND EVIDENCE. (including, EXISTING 128 L.F. 0.30% 18" R. C. P 00 V) F--: UcnF- UV) �V� C0 GRADE 792.81 � x 792.43 792.33 8' WATERLINE .. _ 4 C LOO U3 Ln CD O oo W W -D 792.21 -- = ter- °O L W w o 8" S.D.R. 35 P.V.C. J Q FULL DEPTH GRANULAR BACKFILL W Z o 0 INV. = 790.81 _ e,... - W Y PROPOSED GRADE a CONCRETE 788-61 18„ R. C. P. 0 CRADLE V) v UJ 37 L.F. 787.20 0.30% 18" R.C.P. 21" R.C.P. PROPOSED GRADE INV. =787.2 INV.= 787.1 � o o r- 125 L.F. 0.30% 12" R.C.P. w0 00 JOB zo O OF ZO� 792.14 792.33 791.88 792.04 792.23 W -(0 WU +0 W ° .11 SCALE: 1 "= 50' H OR. U N INV.= 791.88 00 Z ��� 1 -5 VERT. 11 OZ►- . f N. FULL DEPTH 107 _J o 163 L.F. o �� 8' WATERLI E 8" S.Q.R. 35 P.V.C. 192 L.F. GRANULAR BACKFILL IN ._ 4 786.78 J 787.10 787.20 787.70 CO z . 80U. 90 1.56 0.30% Y 18 11 R. C. P. W 15" R. C. P. INV.= 787.20 8" "ATERLINE6 R.C.P. E 34 L.F. 54 L.F. ITcn INV.= 36 781.93 R.C.P. S c� 0.30% 0.30% INV. 781.83 797.90 18" R.C.P. :" FULL DEPTH 35 L.F. 12" R.C.P. 797.80 797.55 799.45 7.36 _ :z.. GRANULAR BACKFILL 1.41%r ... 12" R.C.P. 1+56 . L.F - 86 L. F. 794 22 :.15„ .R . C, P. 1 0.30% co 12" R. C. P. �M 8 WATERLINE 791. 88 18" R. C. P. co z INV. =791.8 8" WATERLINE 30 L.F. 0.30% 21" R.C.P. 5" R.C.P. INV. =787.7 810 800 E 790 800 790 810 800 790 i f t � N U 0 I- O J�� _ O F- 0 JON J p W p � Z +rn Z +M z +M Z +C6 ° •� (D t� Ir- m� i m�� SCALE: "_ HOR* 1 50 o °'ii �Q W�� �Q . �Q U cn f- 0 cn 1 =5' � . >- cn F-- ~�t� ~�t'� J�� - EXISTING GRADE w U Z + . lf_ 1 SCALE: 1 -50 W z +G) -N� zNlf� +� Z +o, JAL �Q. U - o _ I �� � .11 1» =5 VERT. W Y _ m�� mn� Z +Q, o Q� . � cn i-- C*14 U' Q�� >-- (n l- CD N L0 Q ~ - PROPOSED GRADE UPON ABOVE GROUND EVIDENCE. (including, �.-. 128 L.F. 0.30% 18" R. C. P 00 V) F--: UcnF- UV) �V� C0 U) 792.81 � x 792.43 792.33 8' WATERLINE .. _ 4 C LOO U3 Ln CD O oo W W -D 792.21 -- = ter- °O L W w o 8" S.D.R. 35 P.V.C. J Q FULL DEPTH GRANULAR BACKFILL W Z o 0 INV. = 790.81 _ : 141 L.F. Q Z CONCRETE 788-61 18„ R. C. P. 0 CRADLE V) v U 37 L.F. 787.20 0.30% 18" R.C.P. 21" R.C.P. PROPOSED GRADE INV. =787.2 INV.= 787.1 � o o r- 125 L.F. 0.30% 12" R.C.P. w0 00 JOB zo O OF ZO� 792.14 792.33 791.88 792.04 792.23 W -(0 WU +0 ° .11 SCALE: 1 "= 50' H OR. U N INV.= 791.88 00 Z ��� 1 -5 VERT. 11 OZ►- . f N. 790 780 800 790 780 810 790 DA TUM ELEV 780.00 790 "HOLEY MOLEY" SAYS: 1-800-382-5544 CALL TOLL FREE 1-800-42.8-5200 FOR CALLS OUTSIDE OF INDIANA 1-317-571-2648 CALL CARMEL UTILITIES (FOR WATER MAIN LOCATIONS) M z 0 cn w Y Q 0 cJ 0 W INE& 1, IT 9 . O. 10200495 'o STATE OF Q IONAL ♦ •� `� " "11j11111111110 1 SCALE: 1 "= 50' U 0 CHECKED BY: BKR .SHEET N0. O N Ln (D t� Ir- 00 Jo0 l.L W�� W00 ~�t� ~�t'� J�� � 0 Z +,T- O o� w U Z + . lf_ 1 SCALE: 1 -50 HOR. z +G) -N� zNlf� +� Z +o, JAL �Q. U �� � .11 1» =5 VERT. o �¢U _ m�� mn� Z +Q, o Q� . � cn i-- C*14 Q�� >-- (n l- CD N L0 Q ~ �Q . �Q . :D - v :D - v < < U UPON ABOVE GROUND EVIDENCE. (including, �.-. 0 00 V) F--: UcnF- UV) �V� C0 U) z _ � x I N - 4 C LOO U3 Ln CD O oo W W -D � Ln Z a� ter- °O L W w o ,� J Q W Z o 0 :D J EXISTING GRADE _ V I Q Z YI 0 V) v U PROPOSED GRADE - 125 L.F. 0.30% 12" R.C.P. OF ,, 15 R.C.P. NW 792.14 792.33 791.88 792.04 792.23 792.70 INV.= 791.88 00 Z 107 L.F. o 163 L.F. o �� 8' WATERLI E 8" S.Q.R. 35 P.V.C. IN ._ 4 786.78 787.10 787.20 787.70 30 L.F. 0.30% 18 11 R. C. P. W 15" R. C. P. INV.= 787.20 24" R.C.P. E 54 L.F. INV.= 36 781.93 R.C.P. S 0.30% INV. 781.83 18" R.C.P. 800 790 780 810 790 DA TUM ELEV 780.00 790 "HOLEY MOLEY" SAYS: 1-800-382-5544 CALL TOLL FREE 1-800-42.8-5200 FOR CALLS OUTSIDE OF INDIANA 1-317-571-2648 CALL CARMEL UTILITIES (FOR WATER MAIN LOCATIONS) M z 0 cn w Y Q 0 cJ 0 W INE& 1, IT 9 . O. 10200495 'o STATE OF Q IONAL ♦ •� `� " "11j11111111110 1 SCALE: 1 "= 50' U 0 CHECKED BY: BKR .SHEET N0. N W_ l.L w U • V U) - o w Cn C*14 CAUTION CD N L0 LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED 0 00 UPON ABOVE GROUND EVIDENCE. (including, �.-. 0 00 c) Q C0 U) z _ � x I N Q� 4 C LOO U3 Ln CD O oo W W -D � Ln a� ter- °O L W w o ,� U Q W Z o 0 :D V I Q Z 0 V) v Q z Q 0 z z 0 U z 0 -I Q EVIDENCE OR FOR WHICH NO ABOVE GROUND -J EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS L i OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND At I MW'URIIrDnW Q U W CHECKED BY: BKR .SHEET N0. L1_ CAUTION LL.. LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED 0 UPON ABOVE GROUND EVIDENCE. (including, �.-. but not limited to, manholes, inlets, valves, & marks made upon the ground by others.) AND v, ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND Q z Q 0 z z 0 U z 0 -I Q EVIDENCE OR FOR WHICH NO ABOVE GROUND -J EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS L i OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND At I MW'URIIrDnW Q S &A JOB NO. 52790S1 U DRAWN BY: AA KRG CHECKED BY: BKR .SHEET N0. S &A JOB NO. 52790S1 ,i M a N n Ln 0 N N O to rn M a M U Cn M 0 n Ln ,M w z N � r V —p „(MIN.) N (CONFORM TO LOCAL REQUIREMENTS) X VALVE BOX 4' SIDEWALK COVER z 1z r_­1 CURB IN ACCORDANCE WITH SPECIFICATIONS GATE VALVE WATER MAIN TEE OR ANCHORING TEE F- I F-) I-- I I \/ F�N 1-1 A K I -T r-'\ 1-" T A I 1 CONCRETE THRUST BLOCK �LL WATERMAIN SERVICE LINES TO GERMINATE 8 FEET BEHIND SIDEWALK AND MARKED WITH A 4" PVC PIPE /VITH A PAINTFn RI [IF Tnp vv it: ru,�:)i —�Hr�) U N L Q U I V A L� IN I REQUIRED ON ALL WATER ✓ INSALLATION AND MEGA LUGS ✓IUST BE INSTALLED AT ALL A Frk-I A NI I r A I . InI NI TQ JO WATERMAIN VALVES ARE TO BE 'LACED WITHIN THE STREETS, CURBS �R �inFWAI K� NOTE: ALL HYDRANTS SHALL INCLUDE A 6" VALVE. UVI\ I � ° .LINE LENGTH OF PIPE TO I Q a p'_6” m MIN. DIRECTION FROM 2' -0" DIA.X2' -0 "DEEP I BASED ON 150 psi TEST PRESSURE PROTECTED DEGREE OF BEND DRAINAGE PIT WITH PLASTIC a W X111= 24 30 WRAP III II II w J 42 NNQ 1.1. O �' Ld 65 DARSE CL CD 95 GRAVEL COCK a 9' 11 ' CONCRETE / CONCRETE BEARING PAD THRUST BLOCK OR ANCHOR CAST —IN —PLACE AGAINST BLOCKING IF UNDISTURBED GROUND REQUIRED IN ACCORDANCE WITH SPECIFICATIONS GATE VALVE WATER MAIN TEE OR ANCHORING TEE F- I F-) I-- I I \/ F�N 1-1 A K I -T r-'\ 1-" T A I 1 CONCRETE THRUST BLOCK �LL WATERMAIN SERVICE LINES TO GERMINATE 8 FEET BEHIND SIDEWALK AND MARKED WITH A 4" PVC PIPE /VITH A PAINTFn RI [IF Tnp vv it: ru,�:)i —�Hr�) U N L Q U I V A L� IN I REQUIRED ON ALL WATER ✓ INSALLATION AND MEGA LUGS ✓IUST BE INSTALLED AT ALL A Frk-I A NI I r A I . InI NI TQ JO WATERMAIN VALVES ARE TO BE 'LACED WITHIN THE STREETS, CURBS �R �inFWAI K� NOTE: ALL HYDRANTS SHALL INCLUDE A 6" VALVE. (NO SCALE) LEGEND 0 PROPOSED HYDRANT w/1 6 VALVE O VALVE REDUCER Ir, e 1 1 _ � ? �•-1 f� may- "o .ter ; ` �'3 �''; F / c::] _ M. I�r / 3 � / rr , SCALE: 1 "= 50' PRESSURE PIPE JOINT RESTRAINT TABLE � O.D. + 1' � LENGTH OF PIPE TO 15 -20' Q IN EACH DIRECTION FROM 1/4 OF BEND ANGLE VALVE BASED ON 150 psi TEST PRESSURE PROTECTED DEGREE OF BEND VIII WITH PLASTIC -III X111= 24 30 WRAP III II II w J 42 I II I I �' Ld 65 1 SO CORP. CL CD 95 , 115 COCK a 9' 11 ' II I II / 1 I 1" COPPER SERVICE 17' 19' 21' ISO PIPE TO BE SUPPORTED ALONG ENTIRE LENGTH - EXCAVATE FOR EACH JOINT WATER SERVICE INSTALLATION (NO SCALE) LEGEND 0 PROPOSED HYDRANT w/1 6 VALVE O VALVE REDUCER Ir, e 1 1 _ � ? �•-1 f� may- "o .ter ; ` �'3 �''; F / c::] _ M. I�r / 3 � / rr , SCALE: 1 "= 50' PRESSURE PIPE JOINT RESTRAINT TABLE LENGTH OF PIPE TO BE RESTRAINED Q IN EACH DIRECTION FROM 1/4 OF BEND } H BASED ON 150 psi TEST PRESSURE N DEGREE OF BEND 6 8 10 12 14 16 18 20 24 30 90 °, TEES & PLUGS 27 35 42 50 58 65 73 80 95 , 115 450 7' 9' 11 ' 13' 15' 17' 19' 21' 24' 29' 22-1/2" 3' 4' 5' 6' 7' 8' 9' 10' 12' 14' 11-1/4,, 2' 2' 3' 3 4' 4' 4' 5' 6' 7' Misiiminn Cover for Pipe Crossings of City Streets For installation of Storm Mains, Water Mains, Sanitary Mains, Water Service Laterals, Sanitary Service Laterals under City streets, regardless of the jurisdiction of the utility, the minimum cover from the top of the installed pavement to the top of the installed pipe shall be the pavement section thickness (all bituminous and aggregate material above the subgrade) plus 1 -0 ". If the standard practice of the utility that has jurisdiction over the installation has a more stringent cover requirement, the more stringent requirement shall govern RESTRAINED JOINTS SHALL BE MECHANICAL JOINT MEGALUG WITH RETAINER GLANDS, US PIPE TR FLEX JOINT SYSTEM, US PIPE FIELD LOK GASKET SYSTEM, OR EQUAL. NOTE: THE ABOVE RESTRAINED JOINT LENGTHS ARE MINIMUM LENGTHS THE DESIGN ENGINEER SHALL DETERMINE IF LONGER LENGTHS ARE REQUIRED. "HOLEY MOLEY" SAYS: 1-800-382-5544 CALL TOLL FREE 1-800-428-5200 FOR CALLS OUTSIDE OF INDIANA 1-317-571-2648 LATERAL S.S.D. 3 S. S. D. TV01 f% A I 1 IM 1 T/ CAUTION LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE 'VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. M z O Of Q Q 0 p. R I NE/,/ S ' �G1STEl � .• �� No. 10200495 'o •. STATE OF �% 0,- �••.•• /NDIA AP' •: Q . •,,�� 0NAL 0 Q Z Q U Z c } H Z N W O U i W o __J z � CD Q J � w W w ~ W U Q � Z -- � 0 W Z U V) LLJ �> 0 CN d- UJ r o Ln 00 CD 00 C) z Q V) ___I z `� Chi L0 CD o o0 w Lj J Ln z a, Q) V Z • j 00 - W 0 I— J C7 Q w Z 0 J w V) O z F- o C) U J W Q U DRAWN BY: CHECKED BY: AA KRG BKR SHEET N0. C /00 S & A JOB N0. 52790S1 I ' Q Z Q U Z } H Z W O U i z ° o __J z � CD Q J � w W ~ W Q � W Z U J W Q U DRAWN BY: CHECKED BY: AA KRG BKR SHEET N0. C /00 S & A JOB N0. 52790S1 I ' W z J N � l' -0 "(MIN.) N (CONFORM TO LOCAL REQUIREMENTS) X Q VALVE BOX r- 4' SIDEWALK COVER CURB IN ACCORDANCE WITH SPECIFICATIONS GATE VALVE WATER MAIN TEE OR ANCHORING TEE CONCRETE THRUST BLOCK FIRE HYDRANT DETAIL (NO SCALE) ALL WATERMAIN SERVICE LINES TO TERMINATE 8 FEET BEHIND SIDEWALK AND MARKED WITH A 4" PVC PIPE WITH A PAINTED BLUE TOP. NOTE-. POSI —CAPS OR EQUIVALENT IS REQUIRED ON ALL WATER VALVE INSALLATION AND MEGA LUGS MUST BE INSTALLED AT ALL MECHANICAL JOINTS. NO WATERMAIN VALVES ARE TO BE PLACED WITHIN THE STREETS, CURBS, OR SIDEWALKS. INSTALL WATERMAIN TRACER WIRE WITH ALL WATER MAINS LAID AND BLUE REFLECTIVE WARNING TAPE MUST BE INSTALLED 18" ABOVE ALL WATERMAINS SAID. NOTE: FIRE HYDRANT MARKERS TO BE INSTALLED IN THE STREET PAVEMENT PERPENDICULAR TO THE FIRE HYDRANT. ALL WATERMAINS SHALL BE DUCTILE IRON AND INSTALLED PER THE CITY OF CARMEL SPECIFICATIONS CONTACT CARMEL UTILITIES FOR WATER MAIN LOCATIONS. O U V I\ I LINE LENGTH OF PIPE TO BE RESTRAINED I HYDRANTS SHALL INCLUDE A 6" VALVE. W Q 0, — 6„ DIRECTION 0. D. + 1• 15' -20' MIN. ANGLE VALVE 2' -0" DIA.X2' -0 "DEEP — WITH ITH PUSTIC III. WRAP M 14 16 18 20 24 DRAINAGE PIT � ° L D a UJ w N AA KRG Ln Ln SHEET N0. III rc N/Q LL O 27 COCORP. 0 50 CONCRETE CONCRETE BEARING PAD THRUST BLOCK OR ANCHOR CAST —IN —PLACE AGAINST BLOCKING IF UNDISTURBED GROUND REQUIRED IN ACCORDANCE WITH SPECIFICATIONS GATE VALVE WATER MAIN TEE OR ANCHORING TEE CONCRETE THRUST BLOCK FIRE HYDRANT DETAIL (NO SCALE) ALL WATERMAIN SERVICE LINES TO TERMINATE 8 FEET BEHIND SIDEWALK AND MARKED WITH A 4" PVC PIPE WITH A PAINTED BLUE TOP. NOTE-. POSI —CAPS OR EQUIVALENT IS REQUIRED ON ALL WATER VALVE INSALLATION AND MEGA LUGS MUST BE INSTALLED AT ALL MECHANICAL JOINTS. NO WATERMAIN VALVES ARE TO BE PLACED WITHIN THE STREETS, CURBS, OR SIDEWALKS. INSTALL WATERMAIN TRACER WIRE WITH ALL WATER MAINS LAID AND BLUE REFLECTIVE WARNING TAPE MUST BE INSTALLED 18" ABOVE ALL WATERMAINS SAID. NOTE: FIRE HYDRANT MARKERS TO BE INSTALLED IN THE STREET PAVEMENT PERPENDICULAR TO THE FIRE HYDRANT. ALL WATERMAINS SHALL BE DUCTILE IRON AND INSTALLED PER THE CITY OF CARMEL SPECIFICATIONS CONTACT CARMEL UTILITIES FOR WATER MAIN LOCATIONS. ALL DUCTILE IRON WATER MAINS SHALL BE BEDDED IN SAND FROM THE BOTTOM OF THE TRENCH TO 12" ABOVE THE PIPE. PRESSURE PIPE JOINT RESTRAINT TABLE NOTE: LENGTH OF PIPE TO BE RESTRAINED ALL HYDRANTS SHALL INCLUDE A 6" VALVE. IN EACH DIRECTION 0. D. + 1• 15' -20' ANGLE VALVE — _III — WITH ITH PUSTIC III. WRAP 10 12 14 16 18 20 24 30 BEND .8 AA KRG Ln Ln SHEET N0. III rc Ln 27 COCORP. 0 50 58 65 73 N 95 , 115 1" COPPER SERVICE %-.. MI \ / 450 7' 9' 11' PIPE LENGTH TO BE SUPPORTED ALONG ENTIRE — EXCAVATE FOR EACH JOINT � 19' WATER SERVICE INSTALLATION 24' 29' 22-1/2 ° 3' 4' 5' 6' (NO SCALE) 8' 9' 10' 12' 14' 11-1/4 0 LEGEND 2' 3' 3' 4' 4' 4' 5' G � PROPOSED HYDRANT 111 6" VALVE 3 -0 O VALVE Cn REDUCER ALL DUCTILE IRON WATER MAINS SHALL BE BEDDED IN SAND FROM THE BOTTOM OF THE TRENCH TO 12" ABOVE THE PIPE. PRESSURE PIPE JOINT RESTRAINT TABLE LENGTH OF PIPE TO BE RESTRAINED IN EACH DIRECTION FROM 1/4 OF BEND BASED ON 150 psi TEST PRESSURE DEGREE OF 6 10 12 14 16 18 20 24 30 BEND .8 AA KRG BKR SHEET N0. 90 °, TEES 27 35 42 50 58 65 73 80 95 , 115 & PLUGS 450 7' 9' 11' 13' 15' 17' 19' 21' 24' 29' 22-1/2 ° 3' 4' 5' 6' 7' 8' 9' 10' 12' 14' 11-1/4 0 2' 2' 3' 3' 4' 4' 4' 5' 6' 7' ONLY MUELLER FIRE HYDRANTS AND VALVES MAY BE USED. Mininuc»t Cover for Pipe Crossings of City Streets For installation of Storm Mains, Water Mains, Sanitary Mains, Water Service Laterals, Sanitary Service Laterals under City streets, regardless of the jurisdiction of the utility, the minimum cover from the top of the installed pavement to the top of the installed pipe shall be the pavement section thickness (all bituminous and aggregate material above the subgrade) plus 1 -0 ". If the standard practice of the utility that has jurisdiction over the installation has a more stringent cover requirement, the more stringent requirement shall govern RESTRAINED JOINTS SHALL BE MECHANICAL JOINT MEGALUG WITH RETAINER GLANDS, US PIPE TR FLEX JOINT SYSTEM, US PIPE FIELD LOK GASKET SYSTEM, OR EQUAL. NOTE: THE ABOVE RESTRAINED JOINT LENGTHS ARE MINIMUM LENGTHS THE DESIGN ENGINEER SHALL DETERMINE IF LONGER LENGTHS ARE REQUIRED. SANITY "HOLEY MOLEY" SAYS: SCALE: 1 "= 50' 1-800-382-5544 CALL TOLL FREE 1-800-428-5200 FOR CALLS OUTSIDE OF INDIANA 1-317-571 2648 S.S.D. 3 S.S.D. W W W W W WATERLINE TYPICAL UTILITY LATERAL PLACEMENT CAUTION LOCATION OF ALL EXISTING UNDERGROUND UTILITIES SHOWN ON THIS PLAN ARE BASED UPON ABOVE GROUND EVIDENCE. (including, but not limited to, manholes, inlets, valves, & marks made upon the ground by others.) AND ARE SPECULATIVE IN NATURE. THERE MAY ALSO BE OTHER EXISITING UNDERGROUND UTILIITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS OF SAID EXISTING UNDERGROUND UTILITIES SHOULD BE VERIFIED BY THE CONTRACTOR PRIOR TO ANY AND ALL CONSTRUCTION. M V) z 0 U) Of Y Q w F- Q 0 �p.RINEti SISTER ' •., �� Q i aft No. 10200495: 'o STATE OF �''�• SS/6NAL 0 CD ly- N 0 W L� w U U C Z � 0 w LU N V) > o W o u7 Q 0 0 O Z T- Q Cn z �- � X � 48 � Ln 00 CD w w ry Ln a> Z a, C� LL- z — W o � CD W Z ° Q) �—' CY) ° w V) C:) z 1- 0 Cp V w 0 < (D z � J w � w w � Q � w z U Q z Q 0 z I— z 0 U z 0 Q z S & A JOB NO. 5279051 w Q U DRAWN BY: CHECKED BY: AA KRG BKR SHEET N0. C / 0 1 S & A JOB NO. 5279051 ,-I -11 , L .f fu Q_ N 0 O 0 N N O J Cn -v U) ._ a O° U Cn i U) O Cn N Ln GENERAL NOTES: I f'f equa . I lame er, a an a l long teen (15) seconds and for manholes six (6) feet in diameter, add an additional . thirty (30) seconds to the time requirements for four (4) C. Blow -off valves shall be those manufactured by Mueller Corporation foot diameter manholes. For all manholes. deeper than twenty -five (H010283 or H- 10291), or equal. (25) feet, the Engineer will determine the applicable minimum elapsed time. D. Angle valves at the end of water service stub are to be copper compression D. If the manhole fails the test, necessary repairs must be made type fitting also and are to be and the vacuum test and repairs must be repeated until the manhole yp g protected with plastic bay over the passes the test. va I ve . E. If manhole joint sealants are pulled out during the vacuum E. 3/4" taps in lines smaller than 4 inches shall be only topped tee or test, the manhole must be disassembled and the joint sealants y y PP replaced. tapping saddle. Water service lines should be marked on curbs with blue paint. (Sewer lateral locations - red). F. Manholes will be subject to visual inspection with all visual . leaks being repaired. 5. Butyl rubber coating shall be applied around each manhole joint from 8. All water mains to be pressure tested for leakage and sterilized in 6- inches above to 6- inches below each joint. The appropriate primer shall be applied prior to applying the rubber coating. Inside joints accordance with _directions from Carmel Water Department. to be filled with precoat plug material. 9. No traffic will be allowed on prepared subgrade prior to paving. 6. The manhole chimneys, including all riser rings shall be sealed using Infi- Shield Uniband or approved equal. Prior to placement, the . top 4- inches of the manhole cone and casting frame shall be cleaned and 10. All street construction within the lines of dedicated right -of -way shall be primed. The Uniband shall extend from 3- inches below the top of the in accordance with the Specifications of the City of Carmel. cone section to 2- inches over the flange of the . manhole casting frame. 7. The casting elevations are set by plan. However, the castings are 11. Property line corners of street intersections are rounded by an arc having to be adjusted in the field by the Engineers representative a 20' radius. Property lines drawn hereon are carried to the P.I. of the should a discrepancy occur between plan grade and existing grade. New manhole ring and cover shall be installed to establish grade. Maximum arc. 9 I . height of adjusting rings shall be 12- inches. 12. A temporary seeding mixture in the areas where stripping of fills have been 8. Backfill around all structures and all cuts under paved areas with granular material. Trenches opening within 5 -feet of paved roadways graded shall be seeded for silt and erosion protection. After grading all shall be backfilled with granular material in accordance with Section - construction areas are to be seeded as follows: 1 211. Backfill under sidewalks shall be granular; unless the walks . I are constructed a minimum of 6 months after backfill has been in place. A. Swale seeding : Seed and fertilize within construction limits with 5# /acre 9. The Contractor shall be responsible for verifying that all state R " highways, city, and county permits have been obtained .by the _ edtop grass, 20# /acre Rye Gross", 20# /acre _Blue Gross", 25# /acre developer prior to start of construction. "Tall Fescue" grass, and 600# /acre 12 -12 -12 fertilizer. 10. The Contractor shall be required to furnish the developer's B. Cut /Fill Seeding Along Paved Areas: Seed and fertilize with 25# /acre "Tall Engineer with a set of prints, marked in red pencil, showing actual sewer location and invert, to include lateral location, depth and Fescue" grass, 20# /acre "Rye Grass ", 15# /acre "Blue Grass" and 600# /acre length. Such asbuilt prints must be received by the Engineer . I 12 -12 -12 fertilizer. before the final contract payment can be authorized. The sanitary sewer laterals and stubs termination shall be indicated on the surface with a metal fence post set immediately above the said termination point. 13. The location of houses (depicted by rectangles) show the pad elevation and /or I 11. All sanitary sewer lines upon completion will be required to pass a low pressure air test. Said test shall be conducted according to outside grade. The finished floor elevation is 8 inches higher, more or less ASTM 1417 -92, and shall be witnessed by an Engineer and a 9 than the outside grade. representative of the District. The testing shall be in accordance with Table 1. Add 0.5 psig for each foot of water above the sewer line 14. It shall be the responsibility of each contractor to verify all existing being tested. utilities and conditions pertaining to his phase of the work. It shall also 12. Deflection tests shall be performed on all flexible* pipe be the contractors responsibility to contact the owners of the various after the final backfill has been in place at least 30 days. No pipe shall exceed a vertical deflection of 5% deflection test results. utilities before work is started. The contractor shall notify in writing the ( *The following are considered non - flexible pipes: concrete pipe, . owners and /or the engineers of any changes, errors, or omissions found on ductile iron pipe) and cast iron pipe). The deflection test shall be these plans or in the field before work is started or resumed. performed with a nine -point mandrel. Proving rings shall be available. 15. All drainage pipe and ditch outfolls to receiving streams shall be 13. All mandrel testing shall be observed by a professional engineer . representative for certification and a representative of the constructed in accordance with drawings, subject however, to any modification District. required by the City of Carmel at the time installation is completed and to . any adjustments needed for field conditions that could not be anticipated on 14. The ends of laterals are to be plugged tight with a braced plastic disc or cap capable of withstanding a low pressure air test without the design drawings. leakage. 15. Bedding for flexible pipe shall be No. 8 crushed stone from 16. Contractor to record dimensions measured along sewer line from nearest 6- inches below the pipe to 12- inches above the pipe. Bedding for rigid pipe shall be No. 8 crushed stone from 6- inches below the pipe manhole to each sanitary sewer lateral. I to the spring line of the pipe and from this point to 12- inches above shall be fill sand or equivalent. Manholes shall be placed on no less 1 17. Contractor to record dimension of each water stub from nearest fire hydrant than 6- inches of No. 8 crushed stone bedding. measured along the water main. 16. Water and sewer line crossings and separations shall be in accordance . with 327 IAC 3 -6 -9. 18. The above locations of laterals, along with any other construction changes 17. Trench shall be opened sufficiently ahead of pipe laying to are to be incorporated on the original construction drawings and record reveal obstruction, and shall be properly protected and /or barricaded drawings submitted to the City Engineer's Office as soon after completion of when left unattended. construction as possible. 18. No water shall be permitted to flow into the sanitary sewer system during construction. Contractor shall utilize a pump to 19. Contractor shall verify subsurface conditions prior to bidding. keep the water level below the pipe. Pump discharge shall be directed to a storm outlet in accordance with state and federal laws and regulations (327 IAC 3- 6 -20). Any pipe entering existing sewers 20. "The engineer and /or owner disclaim any role in the construction means and shall be plugged with screw type mechanical, braced plug until such methods associated with the project as set forth in these plans." time as all tests on the sewers have been completed and the lines have passed all punch lists. 19. All sewer laterals installed by the mainline Contractor shall be bedded the same as the main line sewer. DUCTILE IRON PIPE SPECIFICATIONS 20. Forty -eight (48) hours notice shall be given to the District a. Material: Ductile Iron Pipe in diameters from eight (8) inches through thirty six (36) prior to the start of sewer construction. Also, 48 hours notice shall be given prior to doing any testing on the sewer.. inches shall be centrifugally cast and shall conform to ANSI Specifications A21.51 and AWWA C -151, latest revision. Ductile Iron Pipe shall be Class 50, 51, 52, or 54 wall thickness 21. Manhole castings shall be stamped SANITARY SEWER (Neenah Casting dependent upon site conditions and . provided in minimum laying lenghts of eighteen (18) feet. R 1642A or equal) and be self - sealing type. The casting flange shall be 34 inches and the clear opening shall be 24 inches. Waterproof castings shall be b. Fittings: Fittings shall be standardized for the type of pipe and joint specified and shall Neenah R- 1916 -F1 and stamped SANITARY SEWER. . comply with ANSI A- 21.10, AWWA C -110. 22. The minimum slope for sewer acceptance by the Clay Township Regional Waste District are: c. Joints: Mechanical joints, slip or flanged joints shall be provided. Size of Pipe Minimum Constructed Slope Mechanical joints and accessories shall conform to AWWA Standard C -111, ANSI A- 21.11. The 8 -inch 0.40 10 -inch 0.28 bolts and nuts shall be corrosion resistant high strenght alloy steel. 12 -inch 0.22 The 0 -ring gaskets sealing the slip joint shall be made of rubber of special composition 15 -inch 0.15% having a texture to assure a watertight and permanent seal and shall be the product of a 18 -inch 1 0.12% manufacturer having at least five (5) years experience in the manufacuter of rubber gaskets 23. The Contractor shall provide measurements of the sloe of the for pipe joints. The gasket shall be a continous ring of flexible joint rubber of a composition P p sewer for each manhole section as construction progresses. Such and texture which is resistant to common ingredients of sewage, industrial wastes and measurements shall be certified by a Registered Land Surveyor or groundwater, and which will endure permanently under the conditions likely to be imposed by Engineer and be available on -site for observation by the District's this service. The gasket shall conform to the requirements of AWWA C -111 (ANSI A- 2111). Inspector. No more than three manhole sections can be constructed in Flanged jofnts shall be manufactured with laying dimesions, facing and flange detailed in advance of such measurements. accordance with AWWA Standard C -115 (ANSI A21.15) Class 125. 24. In the event the Contractor does not meet the minimum slopes, the sewer section and any other affected sewer sections shall be reconstructed to. meet such minimum slopes. . 25. Laterals are to be traced with a minimum size of 14 gauge wire from the wye to the terminus. The contractor for the building or home will extend the wire from this terminus to the building cleanout adjacent to the building. CLAY TOWNSHIP REGIONAL WASTE DISTRICT SUN'11ARY OF LATERAL INSTALLATION REQUIREMENTS 1. All houses, buildings, etc., shall correct to the District's sanitary sewer system within 90 days of notice providing a sewer Is within 300 feet for Haaftri County or 100 feet for Boone County of the property Iin7 Onhy one building may connect to the sewer main per lateral unless otherwise approved by the District. 2. No foundation or other storm water drains shall the interconnected to the sewer lateral installed and connected to the Districts sanitary sewer. .3. The existing sewer line from the building to the septic tank may only be used if it is located under a building addition, patio, porch or paved driveway. Air test is required to show if acceptable for re -use. The property owner shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test. 4. The (timer or contractor shall notifj the District prior to covering the installed lateral so that the District can make an inspection to determine compliance with the District's sewer use ordinance. Such notificabon shall be made 24 hours prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on site for scheduled inspection, or fails to cancel inspecAion, an additional fee of $100.00 will be due. This must be paid prior to the time of the follow up inspection. 5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public stirrer, a septic tank "...shall be abandoned and filled v4i earthen material In a safe and sanitary manger." Please contact the appropriate County Board of Health for further information. 6. Acceptable Pipe Liaterials: PVC PIPE: SDR 35, ASTM D -3034, SIX INCH PIPE • PVC PIPE: SDR 21, ASTM D -241, SIX INCH PIPE GASKETS JOINTS ASTTV1 D 3212 . GASKETS ASTM F477 FITTINGS - SDR -26 DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS. CLEAN OUTS TO BE LOCATED THREE FEET WITHIN THE FOUNDATION AND NO MORE THAN 300 FEET APART. 7. Bedding: Use fill sand o; Number 8, 9 or 11 stone Fill rnatehal is to be placed from 6 inches below to 6 inches above the pipe The trench should be a minimum of 18 inches wide 8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting SDR 21 and ASTM D -2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the District and the District's engineer prior to installation_ 9. Where a transition is made betNeen SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed mechanical coupling shall be used. . 10. Laterals shall terminate within 3 feet of the building uraess the conditions ire item #3 above are met. No vlued nine shall be installed outside of buik,ing fouri,dation walls. 11. Additional information on District standards and specifications may be obtained from the District's office during business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site at h ttp :l /wvnv. ct rwd . org r. . Clay Township Regional Waste District 10701 North Col!ege Suite A. Indianapolis, Indiana 46280 Phone: 844 -9200 Fax: 844 -9203 12. Septic effluent shall not be purerped cut into the sanitary sewer system. 13. The District shall Inspect ALL laterals. Please call Vie District office at 844.9200 24 hours prior to time of inspection 14. Contractors shall lay 14 gauge - stranded wire the entire length of the lateral. wire is to be placed on top of the lateral The District Inspector will verify placement of the wire. After inspection, bedding is to be placed on top. 15. Call before you dig. IUPPS 1- 800 - 382 -5544, 48 hours prior to digging, Lateral- rev.01 -05akr 1. CONCRETE OR STONE BEDDING TO EXTEND TO UNDISTURBED TRENCH WALLS. 2. FOR TRENCH WIDTH, REFER TO SPECIFICATIONS. 3. FOR PIPE DIA., REFER TO PLAN AND PROFILES. EDGE OF PAVEMENT, MIN. 6" TOPSOIL TO CURB, GUTTER OR ENSURE GRASS GROWTH SIMILAR STRUCTURE IF NOT UNDER PAVEMENT IN THE PUBLIC R/W ' OR LES MIN. 6" #53 CAP IF . .. -0 UNDER PAVEMENT • _ •! ... 0-1, . I I XW1 . �� ; - - '� FINAL BACKFILL. �� ..;., . - - _ I ....� ..B" BORROW t' r '��M ti • COMPACTED TO 95% :.•• : � -1" .. , . ? STANDARD PROCTOR 1 DENSITY ... :• i .. 3,000 P.S.I. ... r - .. ,.,. CONCRETE I . •.. •• Z • P• • . O tiff >; t0 6" MIN. 6" MIN. CONCRETE ENCASEMENT CLASS "A -A" EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE IN THE PUBLIC R/W FINAL BACKFILL: T_�, B BORROW COMPACTED TO 95% STANDARD PROCTOR DENSITY COMPACTED #8 STONE 6" MIN. 6" MIN. FLEXIBLE PIPE BEDDING iZ OR COMPACTED GRANULAR MATERIAL 3,000 P.S.I. - CONCRETE MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT MIN. 6" #53 CAP IF UNDER PAVEMENT BEDDING, HAUNCHING, INITIAL BACKFILL BEDDING, HAUNCHING AND INITIAL BACKFILL MATERIALS, PLACEMENT AND COMPACTION FOR WATER MAINS, WATER SERVICE LATERALS, SANITARY MAINS AND SANITARY SERVICE LATERALS SHALL BE IN ACCORDANCE WITH THE STANDARD PRACTICE OF THE UTILITY THAT - EDGE OF PAVEMENT, HAS JURISDICTION OVER THE INSTALLATION. CURB, GUTTER OR FINAL BACKFILL SIMILAR STRUCTURE FINAL BACKFILL FOR WATER MAINS, WATER SERVICE LATERALS, IN THE PUBLIC R/W SANITARY MAINS AND SANITARY SERVICE LATERALS UNDER AND WITHIN 5 -FEET OF PAVEMENT SHALL BE B- BORROW FOR MIN. 6" TOPSOIL TO STRUCTURE BACKFILL MEETING THE MATERIAL REQUIREMENTS OF ENSURE GRASS GROWTH THE INDOT AND SHALL BE COMPACTED IN 6 -INCH MAXIMUM LIFTS IF NOT UNDER PAVEMENT TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY FOR THE ENTIRE. DEPTH OF THE MATERIAL PLACED. THE BACKFILL FOR THE MIN. 6" #53 CAP IF TOP 6- INCHES OF THE EXCAVATION BELOW THE START OF THE / . UNDER PAVEMENT AGGREGATE SUBBASE OF THE PAVEMENT SHALL BE NO. 53 STONE MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL . ... :I _11-111-- . / BE COMPACTED TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY. IF THE STANDARD PRACTICE OF THE UTILITY THAT HAS ~ - :.,,••'`'.''•• ;-• : :•`''., '••. °,'t -1.* '-�' ' FINAL BACKFILL: JURISDICTION OVER THE INSTALLATION HAS A MORE STRINGENT `'��''��� "B" BORROW FINAL BACKFILL REQUIREMENT, THE MORE STRINGENT RE UI Q REMENT ' Z_ COMPACTED TO 95% SHALL GOVERN. 1. STANDARD PROCTOR MINIMUM COVER FO-, - ­:_`­ , . ;­­ - :,,. I I %, la, ".. - - .1 . R OR PIPE CROSSINGS OF CITY N STREETS ' .- FOR INSTALLATION OF STORM MAINS, WATER MAINS, SANITARY . - - -. MAINS, WATER SERVICE LATERALS, SANITARY SERVICE LATERALS `' i _ : =: UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE ��`Z UTILITY, THE MINIMUM COVER FROM THE TOP OF THE INSTALLED i . . '' . -.' . :. M PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE .W. �.. :• , <0 PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1 -0 ". IF THE STANDARD. PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE -_ �- INSTALLATION HAS A MORE STRINGENT COVER REQUIREMENT, THE 6 MIN. 6 MIN. MORE STRINGENT REQUIREMENT SHALL GOVERN. CONCRETE CRADLE CLASS "A" W � W I I V I 11 . / -I,,--,`,, I / I-, ol, I I ,�� �,-, I--,-\ . / lo, , \ \ \ / 01 I � � , lo, . . . X, \, 4 .oll Nll��\ t, * .. .. - X "�� . it> * , \\V_i��\ - I-,- .. . . . . . . I "*'�� �\,�>, \__ A . . ,\- �\\\ \� � D, D \ 2500 psi CONCRETE BOTTOM OF TRENCH /� � PIPE BEDDING DETAILS_ NOT TO SCALE MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R-1 916-Fl EAST JORDAN 104522 I 1045V1IT CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, - (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS . SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL, OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). FINISH GRADE " PRECAST CONCRETE ADJUSTING RING N x 24 .13 Q 1 M .. DIA. DOUBLE ROW OF KENT SEAL K, MANHOLE STEPS PER SPECS INFISHIELD "UNIBAND" I - FINISH GRADE INTERIOR JOINTS AND LIFT HOLES ° BUTYL RUBBER • SHALL BE SEALED WITH NON - SHRINK _ • ' GROUT PER SPECS, NO GROUT ABOVE N X TOP OF CONE SECTION V_ Q n--**' ' 4 SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL .: TO ASTM C -443 AND„ ON DOUBLE ROW OF %2" KENT SEAL UNIB NE OR SINGLE ROW OF 1 KENT SEAL UNIBANC 1 } . BUTYL RUBBEI � Z T I ' ~ - � x MANHOLE REINF. PER ASTM SPECS cV PIPE DIA. PER PLAN & PROFILE . I -) s BENCHWALL SHALL BE CLASS "B" CONC. . BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. • i ,f .. MANHOLE TO PIPE CONNECTION BOOTS, INCLUDIN N r- ' LATERALS, SHALL BE A -LOCK, DURA SEAL OR I - I APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL A :; OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN r_ _ _ '%I M `S'� s r � MANHOLES a ' Al vrl In rIrE IN VCR I uEr ins. OF i4 r I. UK GREATER. 4$-On 6" MIN. COMPACTED #8 STONE I.D. SANITARY MANHOLE -TYPE "A" � . "I N 26" SANITARY. MANHOLE R -1642A NOT -TO -SCALE TiOLE 1 TABLE I MINIMUM SPECIFIED TIME REQUIRED FOR A 1.0 psie DROP FOR SIZE AND LENGTH OF PIPE INDICATED Pipe Nlinimum Length for Time for Diameter Time, Minimum Longer Specification Time for Length (L) Shown, mints In. mints Time, ft Length, S 100 ft 150 ft 200 ft 250 ft 300 ft 350 ft 400 ft 450 ft 4 3:48 597 0.360 L 3:46 3:46 3:46 3:46 3:46 3:46 3:46 3:46 6 5:40 386 0.854 L 5:40 5:40 5:40 5AU 5:40 5:40 5:42 6:24 8 7:34 298 1.520 L 7:34 7:34 7:34 7:34 7:36 8:52 10:08 11:24 10 8:26 239 2.374 L 9:28 9:28 9:28 9:63 11:52 13:51 1 15:49 17:48 12 11:20 199 3.418 L 11:20 11:20 11:24 14:15 17:05 19:58 22:47 25:38 16 14:10 158 5.342 L 14:10 14:10 17:48 22:15 26:42 31:09 35:36 40:04 18 17:00 133 7.682 L 17:00 19:13 1 25:38 32:03 26:27 44:52 51:16 57:41. 21 19:50 114 10.470 L 18:60 26:10 34 :54 43:37 52:21 61:00 69:48 78:31 24 22:40 89 13.674 L 22:47 34:11 45:34 56:58 68:22 79:46 91:10 102:33 27 25:30 88 17.306 L 28:51 43:16 57:41 72:07 86:32 100:57 115:22 129:48 30 28:20 80 21.388 L 96:37 53:26 71:13 89:02 108:50 1 124:38 142:25 160:15 33 31:10 72 25.852 L 49:05 64:38 88:10 107:49 129.18 1 150:43 172:21 193:53 38 34:00 I 86 1 30.788 L 1 61:17 76:55 102:12 128:12 153:80 179:29 205:07 230:46 NOT TO SCALE PERSPECTIVE VIEW - EARTH CUT AWAY 0 TO BE USED WHEN CLEAR DISTANCE BETWEEN PIPES IS 18" OR LESS, OR WERE NOTED ON THE DRAWINGS. CONCRETE CRADLE NOT -TO -SCALE EAST JORDAN 104522 1045WT MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R- 1916 -F1 MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R -1642A R- 1916 -F1 CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS -- SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). NOTE: ALL BEDDING & INTAIL BACKFILL SHALL BE INSTALLED IN 6" . TO 12" BALANCED LIFTS DX2 (MAX) TRENCH WIDTH 6" PIPE .12� TAMPED IN PLACE : #8 CRUSHED STONE _\ . . . . . ... . . . ... . . .. . x •. 90� - : . III . El I Wil 6. . l l 1_ .II I 111 II SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE PRECAST CONCRETE ADJUSTING RING DOUBLE ROW OF KENT SEAL . MANHOLE STEPS PER SPECS INTERIOR JOINTS AND LIFT HOLES SHALL BE SEALED WITH NON - SHRINK GROUT PER SPECS, NO GROUT ABOVE TOP OF CONE SECTION SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL TO ASTM C -443 AND ON DOUBLE ROW OF %2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL. MANHOLE REINF. PER ASTM SPECS PIPE DIA. PER PLAN & PROFILE BENCHWALL SHALL BE CLASS "B" CONC. BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. -_ :__ . _ . MANHOLE TO PIPE CONNECTION BOOTS, INCLUDING LATERALS, SHALL BE A -LOCK, DURA SEAL OR APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL AND OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN MANHOLES WITH PIPE INVERT DEPTHS OF 14 FT. OR GREATER. 6" MIN. CONCRETE ENCASEMENT I.D. 6" MIN. COMPACTED #8 STONE SANITARY MANHOLE - TYPE "B" NOT TO SCALE APPROVED SURFACE MARKER iii = iii = iii = iii = iii = iii =iTi =1 I Iii = iii =iii =i UNDISTURBED EARTH NOT -TO -SCALE SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE o MIN. SLOPE SHALL BE >- m Z 0 Cn w Of < LrJ < 0 ** %\ p. R I N,% '''', % �9; �5 •• . �••.••.......••� . , `�� i , �.�j��.., Q-• OG = : • Nos = ' == a . - :1. = * .� . 10200495 : ft. -off STATE OF �� (.c� •''••. //VDIAtNP..••' �C` Gn `.` '�''4' ss�01VAL IN � I_ O N 0 . IJ J LL F-- LJ U - N 0 C.,) Cn = ck� -_ O >_ 04 W cv V) > O Ln d- W Of 0 Ln I =) N Ln .< V) 00 � r-) 00 U 0 co CD 1_1 1` OZ d- r__ O < z � c C,l1 � -- - X N Oct 48 Q) 00 L� - Cn co Oo 4 rn __ CO W M W -° I .. Z O-) N W I Z C � o W o �- W J . L1J Z O i13 ..;j- q _J � � CL LIJ Cn C:) Z I- O up) U (of) J W � O w � D CD Z w O w IIII-iiiiiiiiiiiii- ~ U :D >- I-- (of) W Z = O (.) U < Z < 0 Z I- Z O U Z O I- < Z J w Q MAIN SEWER U DRAWN BY: CHECKED BY: BKR BKR SHEET N0. 5 &A JOB NO. 52790S1 ' TYPICAL SANITARY SEWER SPECIFICATIONS TO BE USED FOR PRIVATE SEWER DEVELOPMENT 1. A All storm sewers shall be constructed with reinforced concrete pipe Class III W WITHIN CLAY TOWNSHIP REGIONAL WASTE DISTRICT or as noted and conform to A.S.T.M. C -76 or latest revision. All manholes R REVISED MAY 2002 shall be precast concrete construction in accordance with State of Indiana 1 1. Standard specifications of the District and Indiana Department of Specifications and shall have Type " A " cast iron ring and cover. i Transportation shall apply for all work and materials. Pipe shall be installed in accordance with Section 715. 2. J Joints in sewer pipe shall conform to A.S.T.M. Specification C -425 or latest 2 2. Sanitary sewer pipe shall be PVC in accordance with ASTM D -3034 revision. T (S.D.R. 35) and ASTM 2321. PVC pipe shall have grooved bell and gasket. The pipe shall be made of PVC plastic having a cell classification of 124548. 3. S Sewer pipe shall be bedded in accordance with detail shown. Sewer trenches 3 shall be kept free of all water. Do not allow water or mud to enter the D 3 PVC sewer fittings shall conform to the requirements of ASTM sewer. m molded in one piece with elastomeric joints and minimum socket depths as specified in sections 6.2 and 7.3.2. Fittings 10" and . l larger shall be molded or fabricated in accordance with section 7.11 with 4. A All pipe or drainage structures in trenches under paved surfaces and within 10 f manufacturers standard pipe bells and gaskets. Wall thickness of. feet of the pavement shall be backfilled with granular material and compacted s specifications. Gaskets for elastomeric joints shall be molded with by approved methods. a a minimum crosssectional area of 0.20 square inches and conform to ASTM F -477 specification. Fittings shall be manufactured by HarcO or equal. 5. N No roof drains, footing drains and / or surface water drains may be connected 4 4. All sanitary manholes shall be precast concrete manholes in accordance to the sanitary sewer system, including temporary connections during S with ASTM C -478 and Section 720. 0 -rings shall conform to C -443. Kent construction. r riser rings and castings. Manhole step spacing shall be no more than 16- inches. Manholes shall be air tested for leakage in accordance with ASTM C1244 -93, Standard Test Method for Concrete Sewer Manholes by 6. S Sewers crossing mains shall be laid to provide minimum distance of 18 inches t the Negative Air Pressure (vacuum) Test. between the outside of the water main and the outside of the sewer. This shall A A. Installation and operation of vacuum equipment an ' p d indicating . b be the case where the water main is L either above or below the sewer. The d devices must be in accordance with manufacturers recommendations and crossing shall be arranged so that the sewer joints will be equidistant and as p performance specifications which have been provided by the for as possible from the water main joints. Where a water main crosses under m manufacturer and accepted by the Engineer. The vacuum equipment must be capable of testing the entire manhole, including the a sewer, adequate structural support shall be provided for the sewer to c casting and riser rings. prevent damage to the water main. When it is impossible to obtain proper horizontal and vertical separation as stipulated above, the sewer shall be 1 B. With the vacuum tester set in place: designed and constructed equal to water pipe and shall be pressure tested to o open. assure watertightness prior to backfilling. 2 2. Draw a vacuum of ten (10) inches of Hg. and close the valve. C. Accepted standards for leakage will be established from the 7. W Water mains shall be of ductile iron Class 350 cement lined pipe, unless e elapsed time for a negative pressure change from ten (10) inches otherwise noted in the plans. t to nine (9) inches of mercury. The maximum allowable leakage rate for a four (4) foot diameter manhole must be in accordance with the following: L A. Water lines shall be of ductile iron pipe, Class 50 cement . I M Minimum Elapsed Time for a . L L I M 10 feet or less 60 seconds B. Stop shall be those manufactured by Ford or Mueller Corporation with AWWA > >10 feet but <15 feet 75 seconds taper thread, and with copper compression type fitting on outlet, or I F For manholes five (5) feet 'n d' t dd dd't' I equa . I lame er, a an a l long teen (15) seconds and for manholes six (6) feet in diameter, add an additional . thirty (30) seconds to the time requirements for four (4) C. Blow -off valves shall be those manufactured by Mueller Corporation foot diameter manholes. For all manholes. deeper than twenty -five (H010283 or H- 10291), or equal. (25) feet, the Engineer will determine the applicable minimum elapsed time. D. Angle valves at the end of water service stub are to be copper compression D. If the manhole fails the test, necessary repairs must be made type fitting also and are to be and the vacuum test and repairs must be repeated until the manhole yp g protected with plastic bay over the passes the test. va I ve . E. If manhole joint sealants are pulled out during the vacuum E. 3/4" taps in lines smaller than 4 inches shall be only topped tee or test, the manhole must be disassembled and the joint sealants y y PP replaced. tapping saddle. Water service lines should be marked on curbs with blue paint. (Sewer lateral locations - red). F. Manholes will be subject to visual inspection with all visual . leaks being repaired. 5. Butyl rubber coating shall be applied around each manhole joint from 8. All water mains to be pressure tested for leakage and sterilized in 6- inches above to 6- inches below each joint. The appropriate primer shall be applied prior to applying the rubber coating. Inside joints accordance with _directions from Carmel Water Department. to be filled with precoat plug material. 9. No traffic will be allowed on prepared subgrade prior to paving. 6. The manhole chimneys, including all riser rings shall be sealed using Infi- Shield Uniband or approved equal. Prior to placement, the . top 4- inches of the manhole cone and casting frame shall be cleaned and 10. All street construction within the lines of dedicated right -of -way shall be primed. The Uniband shall extend from 3- inches below the top of the in accordance with the Specifications of the City of Carmel. cone section to 2- inches over the flange of the . manhole casting frame. 7. The casting elevations are set by plan. However, the castings are 11. Property line corners of street intersections are rounded by an arc having to be adjusted in the field by the Engineers representative a 20' radius. Property lines drawn hereon are carried to the P.I. of the should a discrepancy occur between plan grade and existing grade. New manhole ring and cover shall be installed to establish grade. Maximum arc. 9 I . height of adjusting rings shall be 12- inches. 12. A temporary seeding mixture in the areas where stripping of fills have been 8. Backfill around all structures and all cuts under paved areas with granular material. Trenches opening within 5 -feet of paved roadways graded shall be seeded for silt and erosion protection. After grading all shall be backfilled with granular material in accordance with Section - construction areas are to be seeded as follows: 1 211. Backfill under sidewalks shall be granular; unless the walks . I are constructed a minimum of 6 months after backfill has been in place. A. Swale seeding : Seed and fertilize within construction limits with 5# /acre 9. The Contractor shall be responsible for verifying that all state R " highways, city, and county permits have been obtained .by the _ edtop grass, 20# /acre Rye Gross", 20# /acre _Blue Gross", 25# /acre developer prior to start of construction. "Tall Fescue" grass, and 600# /acre 12 -12 -12 fertilizer. 10. The Contractor shall be required to furnish the developer's B. Cut /Fill Seeding Along Paved Areas: Seed and fertilize with 25# /acre "Tall Engineer with a set of prints, marked in red pencil, showing actual sewer location and invert, to include lateral location, depth and Fescue" grass, 20# /acre "Rye Grass ", 15# /acre "Blue Grass" and 600# /acre length. Such asbuilt prints must be received by the Engineer . I 12 -12 -12 fertilizer. before the final contract payment can be authorized. The sanitary sewer laterals and stubs termination shall be indicated on the surface with a metal fence post set immediately above the said termination point. 13. The location of houses (depicted by rectangles) show the pad elevation and /or I 11. All sanitary sewer lines upon completion will be required to pass a low pressure air test. Said test shall be conducted according to outside grade. The finished floor elevation is 8 inches higher, more or less ASTM 1417 -92, and shall be witnessed by an Engineer and a 9 than the outside grade. representative of the District. The testing shall be in accordance with Table 1. Add 0.5 psig for each foot of water above the sewer line 14. It shall be the responsibility of each contractor to verify all existing being tested. utilities and conditions pertaining to his phase of the work. It shall also 12. Deflection tests shall be performed on all flexible* pipe be the contractors responsibility to contact the owners of the various after the final backfill has been in place at least 30 days. No pipe shall exceed a vertical deflection of 5% deflection test results. utilities before work is started. The contractor shall notify in writing the ( *The following are considered non - flexible pipes: concrete pipe, . owners and /or the engineers of any changes, errors, or omissions found on ductile iron pipe) and cast iron pipe). The deflection test shall be these plans or in the field before work is started or resumed. performed with a nine -point mandrel. Proving rings shall be available. 15. All drainage pipe and ditch outfolls to receiving streams shall be 13. All mandrel testing shall be observed by a professional engineer . representative for certification and a representative of the constructed in accordance with drawings, subject however, to any modification District. required by the City of Carmel at the time installation is completed and to . any adjustments needed for field conditions that could not be anticipated on 14. The ends of laterals are to be plugged tight with a braced plastic disc or cap capable of withstanding a low pressure air test without the design drawings. leakage. 15. Bedding for flexible pipe shall be No. 8 crushed stone from 16. Contractor to record dimensions measured along sewer line from nearest 6- inches below the pipe to 12- inches above the pipe. Bedding for rigid pipe shall be No. 8 crushed stone from 6- inches below the pipe manhole to each sanitary sewer lateral. I to the spring line of the pipe and from this point to 12- inches above shall be fill sand or equivalent. Manholes shall be placed on no less 1 17. Contractor to record dimension of each water stub from nearest fire hydrant than 6- inches of No. 8 crushed stone bedding. measured along the water main. 16. Water and sewer line crossings and separations shall be in accordance . with 327 IAC 3 -6 -9. 18. The above locations of laterals, along with any other construction changes 17. Trench shall be opened sufficiently ahead of pipe laying to are to be incorporated on the original construction drawings and record reveal obstruction, and shall be properly protected and /or barricaded drawings submitted to the City Engineer's Office as soon after completion of when left unattended. construction as possible. 18. No water shall be permitted to flow into the sanitary sewer system during construction. Contractor shall utilize a pump to 19. Contractor shall verify subsurface conditions prior to bidding. keep the water level below the pipe. Pump discharge shall be directed to a storm outlet in accordance with state and federal laws and regulations (327 IAC 3- 6 -20). Any pipe entering existing sewers 20. "The engineer and /or owner disclaim any role in the construction means and shall be plugged with screw type mechanical, braced plug until such methods associated with the project as set forth in these plans." time as all tests on the sewers have been completed and the lines have passed all punch lists. 19. All sewer laterals installed by the mainline Contractor shall be bedded the same as the main line sewer. DUCTILE IRON PIPE SPECIFICATIONS 20. Forty -eight (48) hours notice shall be given to the District a. Material: Ductile Iron Pipe in diameters from eight (8) inches through thirty six (36) prior to the start of sewer construction. Also, 48 hours notice shall be given prior to doing any testing on the sewer.. inches shall be centrifugally cast and shall conform to ANSI Specifications A21.51 and AWWA C -151, latest revision. Ductile Iron Pipe shall be Class 50, 51, 52, or 54 wall thickness 21. Manhole castings shall be stamped SANITARY SEWER (Neenah Casting dependent upon site conditions and . provided in minimum laying lenghts of eighteen (18) feet. R 1642A or equal) and be self - sealing type. The casting flange shall be 34 inches and the clear opening shall be 24 inches. Waterproof castings shall be b. Fittings: Fittings shall be standardized for the type of pipe and joint specified and shall Neenah R- 1916 -F1 and stamped SANITARY SEWER. . comply with ANSI A- 21.10, AWWA C -110. 22. The minimum slope for sewer acceptance by the Clay Township Regional Waste District are: c. Joints: Mechanical joints, slip or flanged joints shall be provided. Size of Pipe Minimum Constructed Slope Mechanical joints and accessories shall conform to AWWA Standard C -111, ANSI A- 21.11. The 8 -inch 0.40 10 -inch 0.28 bolts and nuts shall be corrosion resistant high strenght alloy steel. 12 -inch 0.22 The 0 -ring gaskets sealing the slip joint shall be made of rubber of special composition 15 -inch 0.15% having a texture to assure a watertight and permanent seal and shall be the product of a 18 -inch 1 0.12% manufacturer having at least five (5) years experience in the manufacuter of rubber gaskets 23. The Contractor shall provide measurements of the sloe of the for pipe joints. The gasket shall be a continous ring of flexible joint rubber of a composition P p sewer for each manhole section as construction progresses. Such and texture which is resistant to common ingredients of sewage, industrial wastes and measurements shall be certified by a Registered Land Surveyor or groundwater, and which will endure permanently under the conditions likely to be imposed by Engineer and be available on -site for observation by the District's this service. The gasket shall conform to the requirements of AWWA C -111 (ANSI A- 2111). Inspector. No more than three manhole sections can be constructed in Flanged jofnts shall be manufactured with laying dimesions, facing and flange detailed in advance of such measurements. accordance with AWWA Standard C -115 (ANSI A21.15) Class 125. 24. In the event the Contractor does not meet the minimum slopes, the sewer section and any other affected sewer sections shall be reconstructed to. meet such minimum slopes. . 25. Laterals are to be traced with a minimum size of 14 gauge wire from the wye to the terminus. The contractor for the building or home will extend the wire from this terminus to the building cleanout adjacent to the building. CLAY TOWNSHIP REGIONAL WASTE DISTRICT SUN'11ARY OF LATERAL INSTALLATION REQUIREMENTS 1. All houses, buildings, etc., shall correct to the District's sanitary sewer system within 90 days of notice providing a sewer Is within 300 feet for Haaftri County or 100 feet for Boone County of the property Iin7 Onhy one building may connect to the sewer main per lateral unless otherwise approved by the District. 2. No foundation or other storm water drains shall the interconnected to the sewer lateral installed and connected to the Districts sanitary sewer. .3. The existing sewer line from the building to the septic tank may only be used if it is located under a building addition, patio, porch or paved driveway. Air test is required to show if acceptable for re -use. The property owner shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test. 4. The (timer or contractor shall notifj the District prior to covering the installed lateral so that the District can make an inspection to determine compliance with the District's sewer use ordinance. Such notificabon shall be made 24 hours prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on site for scheduled inspection, or fails to cancel inspecAion, an additional fee of $100.00 will be due. This must be paid prior to the time of the follow up inspection. 5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public stirrer, a septic tank "...shall be abandoned and filled v4i earthen material In a safe and sanitary manger." Please contact the appropriate County Board of Health for further information. 6. Acceptable Pipe Liaterials: PVC PIPE: SDR 35, ASTM D -3034, SIX INCH PIPE • PVC PIPE: SDR 21, ASTM D -241, SIX INCH PIPE GASKETS JOINTS ASTTV1 D 3212 . GASKETS ASTM F477 FITTINGS - SDR -26 DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS. CLEAN OUTS TO BE LOCATED THREE FEET WITHIN THE FOUNDATION AND NO MORE THAN 300 FEET APART. 7. Bedding: Use fill sand o; Number 8, 9 or 11 stone Fill rnatehal is to be placed from 6 inches below to 6 inches above the pipe The trench should be a minimum of 18 inches wide 8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting SDR 21 and ASTM D -2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the District and the District's engineer prior to installation_ 9. Where a transition is made betNeen SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed mechanical coupling shall be used. . 10. Laterals shall terminate within 3 feet of the building uraess the conditions ire item #3 above are met. No vlued nine shall be installed outside of buik,ing fouri,dation walls. 11. Additional information on District standards and specifications may be obtained from the District's office during business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site at h ttp :l /wvnv. ct rwd . org r. . Clay Township Regional Waste District 10701 North Col!ege Suite A. Indianapolis, Indiana 46280 Phone: 844 -9200 Fax: 844 -9203 12. Septic effluent shall not be purerped cut into the sanitary sewer system. 13. The District shall Inspect ALL laterals. Please call Vie District office at 844.9200 24 hours prior to time of inspection 14. Contractors shall lay 14 gauge - stranded wire the entire length of the lateral. wire is to be placed on top of the lateral The District Inspector will verify placement of the wire. After inspection, bedding is to be placed on top. 15. Call before you dig. IUPPS 1- 800 - 382 -5544, 48 hours prior to digging, Lateral- rev.01 -05akr 1. CONCRETE OR STONE BEDDING TO EXTEND TO UNDISTURBED TRENCH WALLS. 2. FOR TRENCH WIDTH, REFER TO SPECIFICATIONS. 3. FOR PIPE DIA., REFER TO PLAN AND PROFILES. EDGE OF PAVEMENT, MIN. 6" TOPSOIL TO CURB, GUTTER OR ENSURE GRASS GROWTH SIMILAR STRUCTURE IF NOT UNDER PAVEMENT IN THE PUBLIC R/W ' OR LES MIN. 6" #53 CAP IF . .. -0 UNDER PAVEMENT • _ •! ... 0-1, . I I XW1 . �� ; - - '� FINAL BACKFILL. �� ..;., . - - _ I ....� ..B" BORROW t' r '��M ti • COMPACTED TO 95% :.•• : � -1" .. , . ? STANDARD PROCTOR 1 DENSITY ... :• i .. 3,000 P.S.I. ... r - .. ,.,. CONCRETE I . •.. •• Z • P• • . O tiff >; t0 6" MIN. 6" MIN. CONCRETE ENCASEMENT CLASS "A -A" EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE IN THE PUBLIC R/W FINAL BACKFILL: T_�, B BORROW COMPACTED TO 95% STANDARD PROCTOR DENSITY COMPACTED #8 STONE 6" MIN. 6" MIN. FLEXIBLE PIPE BEDDING iZ OR COMPACTED GRANULAR MATERIAL 3,000 P.S.I. - CONCRETE MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT MIN. 6" #53 CAP IF UNDER PAVEMENT BEDDING, HAUNCHING, INITIAL BACKFILL BEDDING, HAUNCHING AND INITIAL BACKFILL MATERIALS, PLACEMENT AND COMPACTION FOR WATER MAINS, WATER SERVICE LATERALS, SANITARY MAINS AND SANITARY SERVICE LATERALS SHALL BE IN ACCORDANCE WITH THE STANDARD PRACTICE OF THE UTILITY THAT - EDGE OF PAVEMENT, HAS JURISDICTION OVER THE INSTALLATION. CURB, GUTTER OR FINAL BACKFILL SIMILAR STRUCTURE FINAL BACKFILL FOR WATER MAINS, WATER SERVICE LATERALS, IN THE PUBLIC R/W SANITARY MAINS AND SANITARY SERVICE LATERALS UNDER AND WITHIN 5 -FEET OF PAVEMENT SHALL BE B- BORROW FOR MIN. 6" TOPSOIL TO STRUCTURE BACKFILL MEETING THE MATERIAL REQUIREMENTS OF ENSURE GRASS GROWTH THE INDOT AND SHALL BE COMPACTED IN 6 -INCH MAXIMUM LIFTS IF NOT UNDER PAVEMENT TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY FOR THE ENTIRE. DEPTH OF THE MATERIAL PLACED. THE BACKFILL FOR THE MIN. 6" #53 CAP IF TOP 6- INCHES OF THE EXCAVATION BELOW THE START OF THE / . UNDER PAVEMENT AGGREGATE SUBBASE OF THE PAVEMENT SHALL BE NO. 53 STONE MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL . ... :I _11-111-- . / BE COMPACTED TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY. IF THE STANDARD PRACTICE OF THE UTILITY THAT HAS ~ - :.,,••'`'.''•• ;-• : :•`''., '••. °,'t -1.* '-�' ' FINAL BACKFILL: JURISDICTION OVER THE INSTALLATION HAS A MORE STRINGENT `'��''��� "B" BORROW FINAL BACKFILL REQUIREMENT, THE MORE STRINGENT RE UI Q REMENT ' Z_ COMPACTED TO 95% SHALL GOVERN. 1. STANDARD PROCTOR MINIMUM COVER FO-, - ­:_`­ , . ;­­ - :,,. I I %, la, ".. - - .1 . R OR PIPE CROSSINGS OF CITY N STREETS ' .- FOR INSTALLATION OF STORM MAINS, WATER MAINS, SANITARY . - - -. MAINS, WATER SERVICE LATERALS, SANITARY SERVICE LATERALS `' i _ : =: UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE ��`Z UTILITY, THE MINIMUM COVER FROM THE TOP OF THE INSTALLED i . . '' . -.' . :. M PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE .W. �.. :• , <0 PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1 -0 ". IF THE STANDARD. PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE -_ �- INSTALLATION HAS A MORE STRINGENT COVER REQUIREMENT, THE 6 MIN. 6 MIN. MORE STRINGENT REQUIREMENT SHALL GOVERN. CONCRETE CRADLE CLASS "A" W � W I I V I 11 . / -I,,--,`,, I / I-, ol, I I ,�� �,-, I--,-\ . / lo, , \ \ \ / 01 I � � , lo, . . . X, \, 4 .oll Nll��\ t, * .. .. - X "�� . it> * , \\V_i��\ - I-,- .. . . . . . . I "*'�� �\,�>, \__ A . . ,\- �\\\ \� � D, D \ 2500 psi CONCRETE BOTTOM OF TRENCH /� � PIPE BEDDING DETAILS_ NOT TO SCALE MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R-1 916-Fl EAST JORDAN 104522 I 1045V1IT CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, - (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS . SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL, OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). FINISH GRADE " PRECAST CONCRETE ADJUSTING RING N x 24 .13 Q 1 M .. DIA. DOUBLE ROW OF KENT SEAL K, MANHOLE STEPS PER SPECS INFISHIELD "UNIBAND" I - FINISH GRADE INTERIOR JOINTS AND LIFT HOLES ° BUTYL RUBBER • SHALL BE SEALED WITH NON - SHRINK _ • ' GROUT PER SPECS, NO GROUT ABOVE N X TOP OF CONE SECTION V_ Q n--**' ' 4 SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL .: TO ASTM C -443 AND„ ON DOUBLE ROW OF %2" KENT SEAL UNIB NE OR SINGLE ROW OF 1 KENT SEAL UNIBANC 1 } . BUTYL RUBBEI � Z T I ' ~ - � x MANHOLE REINF. PER ASTM SPECS cV PIPE DIA. PER PLAN & PROFILE . I -) s BENCHWALL SHALL BE CLASS "B" CONC. . BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. • i ,f .. MANHOLE TO PIPE CONNECTION BOOTS, INCLUDIN N r- ' LATERALS, SHALL BE A -LOCK, DURA SEAL OR I - I APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL A :; OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN r_ _ _ '%I M `S'� s r � MANHOLES a ' Al vrl In rIrE IN VCR I uEr ins. OF i4 r I. UK GREATER. 4$-On 6" MIN. COMPACTED #8 STONE I.D. SANITARY MANHOLE -TYPE "A" � . "I N 26" SANITARY. MANHOLE R -1642A NOT -TO -SCALE TiOLE 1 TABLE I MINIMUM SPECIFIED TIME REQUIRED FOR A 1.0 psie DROP FOR SIZE AND LENGTH OF PIPE INDICATED Pipe Nlinimum Length for Time for Diameter Time, Minimum Longer Specification Time for Length (L) Shown, mints In. mints Time, ft Length, S 100 ft 150 ft 200 ft 250 ft 300 ft 350 ft 400 ft 450 ft 4 3:48 597 0.360 L 3:46 3:46 3:46 3:46 3:46 3:46 3:46 3:46 6 5:40 386 0.854 L 5:40 5:40 5:40 5AU 5:40 5:40 5:42 6:24 8 7:34 298 1.520 L 7:34 7:34 7:34 7:34 7:36 8:52 10:08 11:24 10 8:26 239 2.374 L 9:28 9:28 9:28 9:63 11:52 13:51 1 15:49 17:48 12 11:20 199 3.418 L 11:20 11:20 11:24 14:15 17:05 19:58 22:47 25:38 16 14:10 158 5.342 L 14:10 14:10 17:48 22:15 26:42 31:09 35:36 40:04 18 17:00 133 7.682 L 17:00 19:13 1 25:38 32:03 26:27 44:52 51:16 57:41. 21 19:50 114 10.470 L 18:60 26:10 34 :54 43:37 52:21 61:00 69:48 78:31 24 22:40 89 13.674 L 22:47 34:11 45:34 56:58 68:22 79:46 91:10 102:33 27 25:30 88 17.306 L 28:51 43:16 57:41 72:07 86:32 100:57 115:22 129:48 30 28:20 80 21.388 L 96:37 53:26 71:13 89:02 108:50 1 124:38 142:25 160:15 33 31:10 72 25.852 L 49:05 64:38 88:10 107:49 129.18 1 150:43 172:21 193:53 38 34:00 I 86 1 30.788 L 1 61:17 76:55 102:12 128:12 153:80 179:29 205:07 230:46 NOT TO SCALE PERSPECTIVE VIEW - EARTH CUT AWAY 0 TO BE USED WHEN CLEAR DISTANCE BETWEEN PIPES IS 18" OR LESS, OR WERE NOTED ON THE DRAWINGS. CONCRETE CRADLE NOT -TO -SCALE EAST JORDAN 104522 1045WT MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R- 1916 -F1 MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R -1642A R- 1916 -F1 CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS -- SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). NOTE: ALL BEDDING & INTAIL BACKFILL SHALL BE INSTALLED IN 6" . TO 12" BALANCED LIFTS DX2 (MAX) TRENCH WIDTH 6" PIPE .12� TAMPED IN PLACE : #8 CRUSHED STONE _\ . . . . . ... . . . ... . . .. . x •. 90� - : . III . El I Wil 6. . l l 1_ .II I 111 II SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE PRECAST CONCRETE ADJUSTING RING DOUBLE ROW OF KENT SEAL . MANHOLE STEPS PER SPECS INTERIOR JOINTS AND LIFT HOLES SHALL BE SEALED WITH NON - SHRINK GROUT PER SPECS, NO GROUT ABOVE TOP OF CONE SECTION SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL TO ASTM C -443 AND ON DOUBLE ROW OF %2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL. MANHOLE REINF. PER ASTM SPECS PIPE DIA. PER PLAN & PROFILE BENCHWALL SHALL BE CLASS "B" CONC. BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. -_ :__ . _ . MANHOLE TO PIPE CONNECTION BOOTS, INCLUDING LATERALS, SHALL BE A -LOCK, DURA SEAL OR APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL AND OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN MANHOLES WITH PIPE INVERT DEPTHS OF 14 FT. OR GREATER. 6" MIN. CONCRETE ENCASEMENT I.D. 6" MIN. COMPACTED #8 STONE SANITARY MANHOLE - TYPE "B" NOT TO SCALE APPROVED SURFACE MARKER iii = iii = iii = iii = iii = iii =iTi =1 I Iii = iii =iii =i UNDISTURBED EARTH NOT -TO -SCALE SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE o MIN. SLOPE SHALL BE >- m Z 0 Cn w Of < LrJ < 0 ** %\ p. R I N,% '''', % �9; �5 •• . �••.••.......••� . , `�� i , �.�j��.., Q-• OG = : • Nos = ' == a . - :1. = * .� . 10200495 : ft. -off STATE OF �� (.c� •''••. //VDIAtNP..••' �C` Gn `.` '�''4' ss�01VAL IN � I_ O N 0 . IJ J LL F-- LJ U - N 0 C.,) Cn = ck� -_ O >_ 04 W cv V) > O Ln d- W Of 0 Ln I =) N Ln .< V) 00 � r-) 00 U 0 co CD 1_1 1` OZ d- r__ O < z � c C,l1 � -- - X N Oct 48 Q) 00 L� - Cn co Oo 4 rn __ CO W M W -° I .. Z O-) N W I Z C � o W o �- W J . L1J Z O i13 ..;j- q _J � � CL LIJ Cn C:) Z I- O up) U (of) J W � O w � D CD Z w O w IIII-iiiiiiiiiiiii- ~ U :D >- I-- (of) W Z = O (.) U < Z < 0 Z I- Z O U Z O I- < Z J w Q MAIN SEWER U DRAWN BY: CHECKED BY: BKR BKR SHEET N0. 5 &A JOB NO. 52790S1 ' any adjustments needed for field conditions that could not be anticipated on 14. The ends of laterals are to be plugged tight with a braced plastic disc or cap capable of withstanding a low pressure air test without the design drawings. leakage. 15. Bedding for flexible pipe shall be No. 8 crushed stone from 16. Contractor to record dimensions measured along sewer line from nearest 6- inches below the pipe to 12- inches above the pipe. Bedding for rigid pipe shall be No. 8 crushed stone from 6- inches below the pipe manhole to each sanitary sewer lateral. I to the spring line of the pipe and from this point to 12- inches above shall be fill sand or equivalent. Manholes shall be placed on no less 1 17. Contractor to record dimension of each water stub from nearest fire hydrant than 6- inches of No. 8 crushed stone bedding. measured along the water main. 16. Water and sewer line crossings and separations shall be in accordance . with 327 IAC 3 -6 -9. 18. The above locations of laterals, along with any other construction changes 17. Trench shall be opened sufficiently ahead of pipe laying to are to be incorporated on the original construction drawings and record reveal obstruction, and shall be properly protected and /or barricaded drawings submitted to the City Engineer's Office as soon after completion of when left unattended. construction as possible. 18. No water shall be permitted to flow into the sanitary sewer system during construction. Contractor shall utilize a pump to 19. Contractor shall verify subsurface conditions prior to bidding. keep the water level below the pipe. Pump discharge shall be directed to a storm outlet in accordance with state and federal laws and regulations (327 IAC 3- 6 -20). Any pipe entering existing sewers 20. "The engineer and /or owner disclaim any role in the construction means and shall be plugged with screw type mechanical, braced plug until such methods associated with the project as set forth in these plans." time as all tests on the sewers have been completed and the lines have passed all punch lists. 19. All sewer laterals installed by the mainline Contractor shall be bedded the same as the main line sewer. DUCTILE IRON PIPE SPECIFICATIONS 20. Forty -eight (48) hours notice shall be given to the District a. Material: Ductile Iron Pipe in diameters from eight (8) inches through thirty six (36) prior to the start of sewer construction. Also, 48 hours notice shall be given prior to doing any testing on the sewer.. inches shall be centrifugally cast and shall conform to ANSI Specifications A21.51 and AWWA C -151, latest revision. Ductile Iron Pipe shall be Class 50, 51, 52, or 54 wall thickness 21. Manhole castings shall be stamped SANITARY SEWER (Neenah Casting dependent upon site conditions and . provided in minimum laying lenghts of eighteen (18) feet. R 1642A or equal) and be self - sealing type. The casting flange shall be 34 inches and the clear opening shall be 24 inches. Waterproof castings shall be b. Fittings: Fittings shall be standardized for the type of pipe and joint specified and shall Neenah R- 1916 -F1 and stamped SANITARY SEWER. . comply with ANSI A- 21.10, AWWA C -110. 22. The minimum slope for sewer acceptance by the Clay Township Regional Waste District are: c. Joints: Mechanical joints, slip or flanged joints shall be provided. Size of Pipe Minimum Constructed Slope Mechanical joints and accessories shall conform to AWWA Standard C -111, ANSI A- 21.11. The 8 -inch 0.40 10 -inch 0.28 bolts and nuts shall be corrosion resistant high strenght alloy steel. 12 -inch 0.22 The 0 -ring gaskets sealing the slip joint shall be made of rubber of special composition 15 -inch 0.15% having a texture to assure a watertight and permanent seal and shall be the product of a 18 -inch 1 0.12% manufacturer having at least five (5) years experience in the manufacuter of rubber gaskets 23. The Contractor shall provide measurements of the sloe of the for pipe joints. The gasket shall be a continous ring of flexible joint rubber of a composition P p sewer for each manhole section as construction progresses. Such and texture which is resistant to common ingredients of sewage, industrial wastes and measurements shall be certified by a Registered Land Surveyor or groundwater, and which will endure permanently under the conditions likely to be imposed by Engineer and be available on -site for observation by the District's this service. The gasket shall conform to the requirements of AWWA C -111 (ANSI A- 2111). Inspector. No more than three manhole sections can be constructed in Flanged jofnts shall be manufactured with laying dimesions, facing and flange detailed in advance of such measurements. accordance with AWWA Standard C -115 (ANSI A21.15) Class 125. 24. In the event the Contractor does not meet the minimum slopes, the sewer section and any other affected sewer sections shall be reconstructed to. meet such minimum slopes. . 25. Laterals are to be traced with a minimum size of 14 gauge wire from the wye to the terminus. The contractor for the building or home will extend the wire from this terminus to the building cleanout adjacent to the building. CLAY TOWNSHIP REGIONAL WASTE DISTRICT SUN'11ARY OF LATERAL INSTALLATION REQUIREMENTS 1. All houses, buildings, etc., shall correct to the District's sanitary sewer system within 90 days of notice providing a sewer Is within 300 feet for Haaftri County or 100 feet for Boone County of the property Iin7 Onhy one building may connect to the sewer main per lateral unless otherwise approved by the District. 2. No foundation or other storm water drains shall the interconnected to the sewer lateral installed and connected to the Districts sanitary sewer. .3. The existing sewer line from the building to the septic tank may only be used if it is located under a building addition, patio, porch or paved driveway. Air test is required to show if acceptable for re -use. The property owner shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test. 4. The (timer or contractor shall notifj the District prior to covering the installed lateral so that the District can make an inspection to determine compliance with the District's sewer use ordinance. Such notificabon shall be made 24 hours prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on site for scheduled inspection, or fails to cancel inspecAion, an additional fee of $100.00 will be due. This must be paid prior to the time of the follow up inspection. 5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public stirrer, a septic tank "...shall be abandoned and filled v4i earthen material In a safe and sanitary manger." Please contact the appropriate County Board of Health for further information. 6. Acceptable Pipe Liaterials: PVC PIPE: SDR 35, ASTM D -3034, SIX INCH PIPE • PVC PIPE: SDR 21, ASTM D -241, SIX INCH PIPE GASKETS JOINTS ASTTV1 D 3212 . GASKETS ASTM F477 FITTINGS - SDR -26 DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS. CLEAN OUTS TO BE LOCATED THREE FEET WITHIN THE FOUNDATION AND NO MORE THAN 300 FEET APART. 7. Bedding: Use fill sand o; Number 8, 9 or 11 stone Fill rnatehal is to be placed from 6 inches below to 6 inches above the pipe The trench should be a minimum of 18 inches wide 8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting SDR 21 and ASTM D -2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the District and the District's engineer prior to installation_ 9. Where a transition is made betNeen SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed mechanical coupling shall be used. . 10. Laterals shall terminate within 3 feet of the building uraess the conditions ire item #3 above are met. No vlued nine shall be installed outside of buik,ing fouri,dation walls. 11. Additional information on District standards and specifications may be obtained from the District's office during business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site at h ttp :l /wvnv. ct rwd . org r. . Clay Township Regional Waste District 10701 North Col!ege Suite A. Indianapolis, Indiana 46280 Phone: 844 -9200 Fax: 844 -9203 12. Septic effluent shall not be purerped cut into the sanitary sewer system. 13. The District shall Inspect ALL laterals. Please call Vie District office at 844.9200 24 hours prior to time of inspection 14. Contractors shall lay 14 gauge - stranded wire the entire length of the lateral. wire is to be placed on top of the lateral The District Inspector will verify placement of the wire. After inspection, bedding is to be placed on top. 15. Call before you dig. IUPPS 1- 800 - 382 -5544, 48 hours prior to digging, Lateral- rev.01 -05akr 1. CONCRETE OR STONE BEDDING TO EXTEND TO UNDISTURBED TRENCH WALLS. 2. FOR TRENCH WIDTH, REFER TO SPECIFICATIONS. 3. FOR PIPE DIA., REFER TO PLAN AND PROFILES. EDGE OF PAVEMENT, MIN. 6" TOPSOIL TO CURB, GUTTER OR ENSURE GRASS GROWTH SIMILAR STRUCTURE IF NOT UNDER PAVEMENT IN THE PUBLIC R/W ' OR LES MIN. 6" #53 CAP IF . .. -0 UNDER PAVEMENT • _ •! ... 0-1, . I I XW1 . �� ; - - '� FINAL BACKFILL. �� ..;., . - - _ I ....� ..B" BORROW t' r '��M ti • COMPACTED TO 95% :.•• : � -1" .. , . ? STANDARD PROCTOR 1 DENSITY ... :• i .. 3,000 P.S.I. ... r - .. ,.,. CONCRETE I . •.. •• Z • P• • . O tiff >; t0 6" MIN. 6" MIN. CONCRETE ENCASEMENT CLASS "A -A" EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE IN THE PUBLIC R/W FINAL BACKFILL: T_�, B BORROW COMPACTED TO 95% STANDARD PROCTOR DENSITY COMPACTED #8 STONE 6" MIN. 6" MIN. FLEXIBLE PIPE BEDDING iZ OR COMPACTED GRANULAR MATERIAL 3,000 P.S.I. - CONCRETE MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT MIN. 6" #53 CAP IF UNDER PAVEMENT BEDDING, HAUNCHING, INITIAL BACKFILL BEDDING, HAUNCHING AND INITIAL BACKFILL MATERIALS, PLACEMENT AND COMPACTION FOR WATER MAINS, WATER SERVICE LATERALS, SANITARY MAINS AND SANITARY SERVICE LATERALS SHALL BE IN ACCORDANCE WITH THE STANDARD PRACTICE OF THE UTILITY THAT - EDGE OF PAVEMENT, HAS JURISDICTION OVER THE INSTALLATION. CURB, GUTTER OR FINAL BACKFILL SIMILAR STRUCTURE FINAL BACKFILL FOR WATER MAINS, WATER SERVICE LATERALS, IN THE PUBLIC R/W SANITARY MAINS AND SANITARY SERVICE LATERALS UNDER AND WITHIN 5 -FEET OF PAVEMENT SHALL BE B- BORROW FOR MIN. 6" TOPSOIL TO STRUCTURE BACKFILL MEETING THE MATERIAL REQUIREMENTS OF ENSURE GRASS GROWTH THE INDOT AND SHALL BE COMPACTED IN 6 -INCH MAXIMUM LIFTS IF NOT UNDER PAVEMENT TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY FOR THE ENTIRE. DEPTH OF THE MATERIAL PLACED. THE BACKFILL FOR THE MIN. 6" #53 CAP IF TOP 6- INCHES OF THE EXCAVATION BELOW THE START OF THE / . UNDER PAVEMENT AGGREGATE SUBBASE OF THE PAVEMENT SHALL BE NO. 53 STONE MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL . ... :I _11-111-- . / BE COMPACTED TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY. IF THE STANDARD PRACTICE OF THE UTILITY THAT HAS ~ - :.,,••'`'.''•• ;-• : :•`''., '••. °,'t -1.* '-�' ' FINAL BACKFILL: JURISDICTION OVER THE INSTALLATION HAS A MORE STRINGENT `'��''��� "B" BORROW FINAL BACKFILL REQUIREMENT, THE MORE STRINGENT RE UI Q REMENT ' Z_ COMPACTED TO 95% SHALL GOVERN. 1. STANDARD PROCTOR MINIMUM COVER FO-, - ­:_`­ , . ;­­ - :,,. I I %, la, ".. - - .1 . R OR PIPE CROSSINGS OF CITY N STREETS ' .- FOR INSTALLATION OF STORM MAINS, WATER MAINS, SANITARY . - - -. MAINS, WATER SERVICE LATERALS, SANITARY SERVICE LATERALS `' i _ : =: UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE ��`Z UTILITY, THE MINIMUM COVER FROM THE TOP OF THE INSTALLED i . . '' . -.' . :. M PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE .W. �.. :• , <0 PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1 -0 ". IF THE STANDARD. PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE -_ �- INSTALLATION HAS A MORE STRINGENT COVER REQUIREMENT, THE 6 MIN. 6 MIN. MORE STRINGENT REQUIREMENT SHALL GOVERN. CONCRETE CRADLE CLASS "A" W � W I I V I 11 . / -I,,--,`,, I / I-, ol, I I ,�� �,-, I--,-\ . / lo, , \ \ \ / 01 I � � , lo, . . . X, \, 4 .oll Nll��\ t, * .. .. - X "�� . it> * , \\V_i��\ - I-,- .. . . . . . . I "*'�� �\,�>, \__ A . . ,\- �\\\ \� � D, D \ 2500 psi CONCRETE BOTTOM OF TRENCH /� � PIPE BEDDING DETAILS_ NOT TO SCALE MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R-1 916-Fl EAST JORDAN 104522 I 1045V1IT CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, - (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS . SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL, OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). FINISH GRADE " PRECAST CONCRETE ADJUSTING RING N x 24 .13 Q 1 M .. DIA. DOUBLE ROW OF KENT SEAL K, MANHOLE STEPS PER SPECS INFISHIELD "UNIBAND" I - FINISH GRADE INTERIOR JOINTS AND LIFT HOLES ° BUTYL RUBBER • SHALL BE SEALED WITH NON - SHRINK _ • ' GROUT PER SPECS, NO GROUT ABOVE N X TOP OF CONE SECTION V_ Q n--**' ' 4 SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL .: TO ASTM C -443 AND„ ON DOUBLE ROW OF %2" KENT SEAL UNIB NE OR SINGLE ROW OF 1 KENT SEAL UNIBANC 1 } . BUTYL RUBBEI � Z T I ' ~ - � x MANHOLE REINF. PER ASTM SPECS cV PIPE DIA. PER PLAN & PROFILE . I -) s BENCHWALL SHALL BE CLASS "B" CONC. . BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. • i ,f .. MANHOLE TO PIPE CONNECTION BOOTS, INCLUDIN N r- ' LATERALS, SHALL BE A -LOCK, DURA SEAL OR I - I APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL A :; OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN r_ _ _ '%I M `S'� s r � MANHOLES a ' Al vrl In rIrE IN VCR I uEr ins. OF i4 r I. UK GREATER. 4$-On 6" MIN. COMPACTED #8 STONE I.D. SANITARY MANHOLE -TYPE "A" � . "I N 26" SANITARY. MANHOLE R -1642A NOT -TO -SCALE TiOLE 1 TABLE I MINIMUM SPECIFIED TIME REQUIRED FOR A 1.0 psie DROP FOR SIZE AND LENGTH OF PIPE INDICATED Pipe Nlinimum Length for Time for Diameter Time, Minimum Longer Specification Time for Length (L) Shown, mints In. mints Time, ft Length, S 100 ft 150 ft 200 ft 250 ft 300 ft 350 ft 400 ft 450 ft 4 3:48 597 0.360 L 3:46 3:46 3:46 3:46 3:46 3:46 3:46 3:46 6 5:40 386 0.854 L 5:40 5:40 5:40 5AU 5:40 5:40 5:42 6:24 8 7:34 298 1.520 L 7:34 7:34 7:34 7:34 7:36 8:52 10:08 11:24 10 8:26 239 2.374 L 9:28 9:28 9:28 9:63 11:52 13:51 1 15:49 17:48 12 11:20 199 3.418 L 11:20 11:20 11:24 14:15 17:05 19:58 22:47 25:38 16 14:10 158 5.342 L 14:10 14:10 17:48 22:15 26:42 31:09 35:36 40:04 18 17:00 133 7.682 L 17:00 19:13 1 25:38 32:03 26:27 44:52 51:16 57:41. 21 19:50 114 10.470 L 18:60 26:10 34 :54 43:37 52:21 61:00 69:48 78:31 24 22:40 89 13.674 L 22:47 34:11 45:34 56:58 68:22 79:46 91:10 102:33 27 25:30 88 17.306 L 28:51 43:16 57:41 72:07 86:32 100:57 115:22 129:48 30 28:20 80 21.388 L 96:37 53:26 71:13 89:02 108:50 1 124:38 142:25 160:15 33 31:10 72 25.852 L 49:05 64:38 88:10 107:49 129.18 1 150:43 172:21 193:53 38 34:00 I 86 1 30.788 L 1 61:17 76:55 102:12 128:12 153:80 179:29 205:07 230:46 NOT TO SCALE PERSPECTIVE VIEW - EARTH CUT AWAY 0 TO BE USED WHEN CLEAR DISTANCE BETWEEN PIPES IS 18" OR LESS, OR WERE NOTED ON THE DRAWINGS. CONCRETE CRADLE NOT -TO -SCALE EAST JORDAN 104522 1045WT MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R- 1916 -F1 MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R -1642A R- 1916 -F1 CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS -- SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). NOTE: ALL BEDDING & INTAIL BACKFILL SHALL BE INSTALLED IN 6" . TO 12" BALANCED LIFTS DX2 (MAX) TRENCH WIDTH 6" PIPE .12� TAMPED IN PLACE : #8 CRUSHED STONE _\ . . . . . ... . . . ... . . .. . x •. 90� - : . III . El I Wil 6. . l l 1_ .II I 111 II SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE PRECAST CONCRETE ADJUSTING RING DOUBLE ROW OF KENT SEAL . MANHOLE STEPS PER SPECS INTERIOR JOINTS AND LIFT HOLES SHALL BE SEALED WITH NON - SHRINK GROUT PER SPECS, NO GROUT ABOVE TOP OF CONE SECTION SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL TO ASTM C -443 AND ON DOUBLE ROW OF %2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL. MANHOLE REINF. PER ASTM SPECS PIPE DIA. PER PLAN & PROFILE BENCHWALL SHALL BE CLASS "B" CONC. BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. -_ :__ . _ . MANHOLE TO PIPE CONNECTION BOOTS, INCLUDING LATERALS, SHALL BE A -LOCK, DURA SEAL OR APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL AND OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN MANHOLES WITH PIPE INVERT DEPTHS OF 14 FT. OR GREATER. 6" MIN. CONCRETE ENCASEMENT I.D. 6" MIN. COMPACTED #8 STONE SANITARY MANHOLE - TYPE "B" NOT TO SCALE APPROVED SURFACE MARKER iii = iii = iii = iii = iii = iii =iTi =1 I Iii = iii =iii =i UNDISTURBED EARTH NOT -TO -SCALE SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE o MIN. SLOPE SHALL BE >- m Z 0 Cn w Of < LrJ < 0 ** %\ p. R I N,% '''', % �9; �5 •• . �••.••.......••� . , `�� i , �.�j��.., Q-• OG = : • Nos = ' == a . - :1. = * .� . 10200495 : ft. -off STATE OF �� (.c� •''••. //VDIAtNP..••' �C` Gn `.` '�''4' ss�01VAL IN � I_ O N 0 . IJ J LL F-- LJ U - N 0 C.,) Cn = ck� -_ O >_ 04 W cv V) > O Ln d- W Of 0 Ln I =) N Ln .< V) 00 � r-) 00 U 0 co CD 1_1 1` OZ d- r__ O < z � c C,l1 � -- - X N Oct 48 Q) 00 L� - Cn co Oo 4 rn __ CO W M W -° I .. Z O-) N W I Z C � o W o �- W J . L1J Z O i13 ..;j- q _J � � CL LIJ Cn C:) Z I- O up) U (of) J W � O w � D CD Z w O w IIII-iiiiiiiiiiiii- ~ U :D >- I-- (of) W Z = O (.) U < Z < 0 Z I- Z O U Z O I- < Z J w Q MAIN SEWER U DRAWN BY: CHECKED BY: BKR BKR SHEET N0. 5 &A JOB NO. 52790S1 ' CLAY TOWNSHIP REGIONAL WASTE DISTRICT SUN'11ARY OF LATERAL INSTALLATION REQUIREMENTS 1. All houses, buildings, etc., shall correct to the District's sanitary sewer system within 90 days of notice providing a sewer Is within 300 feet for Haaftri County or 100 feet for Boone County of the property Iin7 Onhy one building may connect to the sewer main per lateral unless otherwise approved by the District. 2. No foundation or other storm water drains shall the interconnected to the sewer lateral installed and connected to the Districts sanitary sewer. .3. The existing sewer line from the building to the septic tank may only be used if it is located under a building addition, patio, porch or paved driveway. Air test is required to show if acceptable for re -use. The property owner shall bear the cost of all testing. The District inspector must be onsite for the duration of the air test. 4. The (timer or contractor shall notifj the District prior to covering the installed lateral so that the District can make an inspection to determine compliance with the District's sewer use ordinance. Such notificabon shall be made 24 hours prior to the need for the inspection. If the inspection fails and a second inspection is required, or contractor is not on site for scheduled inspection, or fails to cancel inspecAion, an additional fee of $100.00 will be due. This must be paid prior to the time of the follow up inspection. 5. Property owners are hereby advised that the County Board of Health regulates the operation and maintenance of private sewage disposal (septic) systems. The County Ordinance provides in part that, upon connection to a public stirrer, a septic tank "...shall be abandoned and filled v4i earthen material In a safe and sanitary manger." Please contact the appropriate County Board of Health for further information. 6. Acceptable Pipe Liaterials: PVC PIPE: SDR 35, ASTM D -3034, SIX INCH PIPE • PVC PIPE: SDR 21, ASTM D -241, SIX INCH PIPE GASKETS JOINTS ASTTV1 D 3212 . GASKETS ASTM F477 FITTINGS - SDR -26 DUCTILE IRON MECHANICAL COUPLING WITH PROPER FITTINGS. CLEAN OUTS TO BE LOCATED THREE FEET WITHIN THE FOUNDATION AND NO MORE THAN 300 FEET APART. 7. Bedding: Use fill sand o; Number 8, 9 or 11 stone Fill rnatehal is to be placed from 6 inches below to 6 inches above the pipe The trench should be a minimum of 18 inches wide 8. Laterals shall be installed no closer than 20 feet from water wells unless PVC pressure grade pipe is used meeting SDR 21 and ASTM D -2241. Any proposed installation requiring pressure pipe shall be reviewed and accepted by the District and the District's engineer prior to installation_ 9. Where a transition is made betNeen SDR 35 pipe and pressure grade SDR 21 pipe, a ductile iron gasketed mechanical coupling shall be used. . 10. Laterals shall terminate within 3 feet of the building uraess the conditions ire item #3 above are met. No vlued nine shall be installed outside of buik,ing fouri,dation walls. 11. Additional information on District standards and specifications may be obtained from the District's office during business hours of 8:00a.m. to 4:30 p.m. Monday through Friday: All District standards can be located on our web site at h ttp :l /wvnv. ct rwd . org r. . Clay Township Regional Waste District 10701 North Col!ege Suite A. Indianapolis, Indiana 46280 Phone: 844 -9200 Fax: 844 -9203 12. Septic effluent shall not be purerped cut into the sanitary sewer system. 13. The District shall Inspect ALL laterals. Please call Vie District office at 844.9200 24 hours prior to time of inspection 14. Contractors shall lay 14 gauge - stranded wire the entire length of the lateral. wire is to be placed on top of the lateral The District Inspector will verify placement of the wire. After inspection, bedding is to be placed on top. 15. Call before you dig. IUPPS 1- 800 - 382 -5544, 48 hours prior to digging, Lateral- rev.01 -05akr 1. CONCRETE OR STONE BEDDING TO EXTEND TO UNDISTURBED TRENCH WALLS. 2. FOR TRENCH WIDTH, REFER TO SPECIFICATIONS. 3. FOR PIPE DIA., REFER TO PLAN AND PROFILES. EDGE OF PAVEMENT, MIN. 6" TOPSOIL TO CURB, GUTTER OR ENSURE GRASS GROWTH SIMILAR STRUCTURE IF NOT UNDER PAVEMENT IN THE PUBLIC R/W ' OR LES MIN. 6" #53 CAP IF . .. -0 UNDER PAVEMENT • _ •! ... 0-1, . I I XW1 . �� ; - - '� FINAL BACKFILL. �� ..;., . - - _ I ....� ..B" BORROW t' r '��M ti • COMPACTED TO 95% :.•• : � -1" .. , . ? STANDARD PROCTOR 1 DENSITY ... :• i .. 3,000 P.S.I. ... r - .. ,.,. CONCRETE I . •.. •• Z • P• • . O tiff >; t0 6" MIN. 6" MIN. CONCRETE ENCASEMENT CLASS "A -A" EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE IN THE PUBLIC R/W FINAL BACKFILL: T_�, B BORROW COMPACTED TO 95% STANDARD PROCTOR DENSITY COMPACTED #8 STONE 6" MIN. 6" MIN. FLEXIBLE PIPE BEDDING iZ OR COMPACTED GRANULAR MATERIAL 3,000 P.S.I. - CONCRETE MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT MIN. 6" #53 CAP IF UNDER PAVEMENT BEDDING, HAUNCHING, INITIAL BACKFILL BEDDING, HAUNCHING AND INITIAL BACKFILL MATERIALS, PLACEMENT AND COMPACTION FOR WATER MAINS, WATER SERVICE LATERALS, SANITARY MAINS AND SANITARY SERVICE LATERALS SHALL BE IN ACCORDANCE WITH THE STANDARD PRACTICE OF THE UTILITY THAT - EDGE OF PAVEMENT, HAS JURISDICTION OVER THE INSTALLATION. CURB, GUTTER OR FINAL BACKFILL SIMILAR STRUCTURE FINAL BACKFILL FOR WATER MAINS, WATER SERVICE LATERALS, IN THE PUBLIC R/W SANITARY MAINS AND SANITARY SERVICE LATERALS UNDER AND WITHIN 5 -FEET OF PAVEMENT SHALL BE B- BORROW FOR MIN. 6" TOPSOIL TO STRUCTURE BACKFILL MEETING THE MATERIAL REQUIREMENTS OF ENSURE GRASS GROWTH THE INDOT AND SHALL BE COMPACTED IN 6 -INCH MAXIMUM LIFTS IF NOT UNDER PAVEMENT TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY FOR THE ENTIRE. DEPTH OF THE MATERIAL PLACED. THE BACKFILL FOR THE MIN. 6" #53 CAP IF TOP 6- INCHES OF THE EXCAVATION BELOW THE START OF THE / . UNDER PAVEMENT AGGREGATE SUBBASE OF THE PAVEMENT SHALL BE NO. 53 STONE MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL . ... :I _11-111-- . / BE COMPACTED TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY. IF THE STANDARD PRACTICE OF THE UTILITY THAT HAS ~ - :.,,••'`'.''•• ;-• : :•`''., '••. °,'t -1.* '-�' ' FINAL BACKFILL: JURISDICTION OVER THE INSTALLATION HAS A MORE STRINGENT `'��''��� "B" BORROW FINAL BACKFILL REQUIREMENT, THE MORE STRINGENT RE UI Q REMENT ' Z_ COMPACTED TO 95% SHALL GOVERN. 1. STANDARD PROCTOR MINIMUM COVER FO-, - ­:_`­ , . ;­­ - :,,. I I %, la, ".. - - .1 . R OR PIPE CROSSINGS OF CITY N STREETS ' .- FOR INSTALLATION OF STORM MAINS, WATER MAINS, SANITARY . - - -. MAINS, WATER SERVICE LATERALS, SANITARY SERVICE LATERALS `' i _ : =: UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE ��`Z UTILITY, THE MINIMUM COVER FROM THE TOP OF THE INSTALLED i . . '' . -.' . :. M PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE .W. �.. :• , <0 PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1 -0 ". IF THE STANDARD. PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE -_ �- INSTALLATION HAS A MORE STRINGENT COVER REQUIREMENT, THE 6 MIN. 6 MIN. MORE STRINGENT REQUIREMENT SHALL GOVERN. CONCRETE CRADLE CLASS "A" W � W I I V I 11 . / -I,,--,`,, I / I-, ol, I I ,�� �,-, I--,-\ . / lo, , \ \ \ / 01 I � � , lo, . . . X, \, 4 .oll Nll��\ t, * .. .. - X "�� . it> * , \\V_i��\ - I-,- .. . . . . . . I "*'�� �\,�>, \__ A . . ,\- �\\\ \� � D, D \ 2500 psi CONCRETE BOTTOM OF TRENCH /� � PIPE BEDDING DETAILS_ NOT TO SCALE MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R-1 916-Fl EAST JORDAN 104522 I 1045V1IT CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, - (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS . SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL, OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). FINISH GRADE " PRECAST CONCRETE ADJUSTING RING N x 24 .13 Q 1 M .. DIA. DOUBLE ROW OF KENT SEAL K, MANHOLE STEPS PER SPECS INFISHIELD "UNIBAND" I - FINISH GRADE INTERIOR JOINTS AND LIFT HOLES ° BUTYL RUBBER • SHALL BE SEALED WITH NON - SHRINK _ • ' GROUT PER SPECS, NO GROUT ABOVE N X TOP OF CONE SECTION V_ Q n--**' ' 4 SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL .: TO ASTM C -443 AND„ ON DOUBLE ROW OF %2" KENT SEAL UNIB NE OR SINGLE ROW OF 1 KENT SEAL UNIBANC 1 } . BUTYL RUBBEI � Z T I ' ~ - � x MANHOLE REINF. PER ASTM SPECS cV PIPE DIA. PER PLAN & PROFILE . I -) s BENCHWALL SHALL BE CLASS "B" CONC. . BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. • i ,f .. MANHOLE TO PIPE CONNECTION BOOTS, INCLUDIN N r- ' LATERALS, SHALL BE A -LOCK, DURA SEAL OR I - I APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL A :; OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN r_ _ _ '%I M `S'� s r � MANHOLES a ' Al vrl In rIrE IN VCR I uEr ins. OF i4 r I. UK GREATER. 4$-On 6" MIN. COMPACTED #8 STONE I.D. SANITARY MANHOLE -TYPE "A" � . "I N 26" SANITARY. MANHOLE R -1642A NOT -TO -SCALE TiOLE 1 TABLE I MINIMUM SPECIFIED TIME REQUIRED FOR A 1.0 psie DROP FOR SIZE AND LENGTH OF PIPE INDICATED Pipe Nlinimum Length for Time for Diameter Time, Minimum Longer Specification Time for Length (L) Shown, mints In. mints Time, ft Length, S 100 ft 150 ft 200 ft 250 ft 300 ft 350 ft 400 ft 450 ft 4 3:48 597 0.360 L 3:46 3:46 3:46 3:46 3:46 3:46 3:46 3:46 6 5:40 386 0.854 L 5:40 5:40 5:40 5AU 5:40 5:40 5:42 6:24 8 7:34 298 1.520 L 7:34 7:34 7:34 7:34 7:36 8:52 10:08 11:24 10 8:26 239 2.374 L 9:28 9:28 9:28 9:63 11:52 13:51 1 15:49 17:48 12 11:20 199 3.418 L 11:20 11:20 11:24 14:15 17:05 19:58 22:47 25:38 16 14:10 158 5.342 L 14:10 14:10 17:48 22:15 26:42 31:09 35:36 40:04 18 17:00 133 7.682 L 17:00 19:13 1 25:38 32:03 26:27 44:52 51:16 57:41. 21 19:50 114 10.470 L 18:60 26:10 34 :54 43:37 52:21 61:00 69:48 78:31 24 22:40 89 13.674 L 22:47 34:11 45:34 56:58 68:22 79:46 91:10 102:33 27 25:30 88 17.306 L 28:51 43:16 57:41 72:07 86:32 100:57 115:22 129:48 30 28:20 80 21.388 L 96:37 53:26 71:13 89:02 108:50 1 124:38 142:25 160:15 33 31:10 72 25.852 L 49:05 64:38 88:10 107:49 129.18 1 150:43 172:21 193:53 38 34:00 I 86 1 30.788 L 1 61:17 76:55 102:12 128:12 153:80 179:29 205:07 230:46 NOT TO SCALE PERSPECTIVE VIEW - EARTH CUT AWAY 0 TO BE USED WHEN CLEAR DISTANCE BETWEEN PIPES IS 18" OR LESS, OR WERE NOTED ON THE DRAWINGS. CONCRETE CRADLE NOT -TO -SCALE EAST JORDAN 104522 1045WT MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R- 1916 -F1 MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R -1642A R- 1916 -F1 CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS -- SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). NOTE: ALL BEDDING & INTAIL BACKFILL SHALL BE INSTALLED IN 6" . TO 12" BALANCED LIFTS DX2 (MAX) TRENCH WIDTH 6" PIPE .12� TAMPED IN PLACE : #8 CRUSHED STONE _\ . . . . . ... . . . ... . . .. . x •. 90� - : . III . El I Wil 6. . l l 1_ .II I 111 II SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE PRECAST CONCRETE ADJUSTING RING DOUBLE ROW OF KENT SEAL . MANHOLE STEPS PER SPECS INTERIOR JOINTS AND LIFT HOLES SHALL BE SEALED WITH NON - SHRINK GROUT PER SPECS, NO GROUT ABOVE TOP OF CONE SECTION SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL TO ASTM C -443 AND ON DOUBLE ROW OF %2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL. MANHOLE REINF. PER ASTM SPECS PIPE DIA. PER PLAN & PROFILE BENCHWALL SHALL BE CLASS "B" CONC. BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. -_ :__ . _ . MANHOLE TO PIPE CONNECTION BOOTS, INCLUDING LATERALS, SHALL BE A -LOCK, DURA SEAL OR APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL AND OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN MANHOLES WITH PIPE INVERT DEPTHS OF 14 FT. OR GREATER. 6" MIN. CONCRETE ENCASEMENT I.D. 6" MIN. COMPACTED #8 STONE SANITARY MANHOLE - TYPE "B" NOT TO SCALE APPROVED SURFACE MARKER iii = iii = iii = iii = iii = iii =iTi =1 I Iii = iii =iii =i UNDISTURBED EARTH NOT -TO -SCALE SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE o MIN. SLOPE SHALL BE >- m Z 0 Cn w Of < LrJ < 0 ** %\ p. R I N,% '''', % �9; �5 •• . �••.••.......••� . , `�� i , �.�j��.., Q-• OG = : • Nos = ' == a . - :1. = * .� . 10200495 : ft. -off STATE OF �� (.c� •''••. //VDIAtNP..••' �C` Gn `.` '�''4' ss�01VAL IN � I_ O N 0 . IJ J LL F-- LJ U - N 0 C.,) Cn = ck� -_ O >_ 04 W cv V) > O Ln d- W Of 0 Ln I =) N Ln .< V) 00 � r-) 00 U 0 co CD 1_1 1` OZ d- r__ O < z � c C,l1 � -- - X N Oct 48 Q) 00 L� - Cn co Oo 4 rn __ CO W M W -° I .. Z O-) N W I Z C � o W o �- W J . L1J Z O i13 ..;j- q _J � � CL LIJ Cn C:) Z I- O up) U (of) J W � O w � D CD Z w O w IIII-iiiiiiiiiiiii- ~ U :D >- I-- (of) W Z = O (.) U < Z < 0 Z I- Z O U Z O I- < Z J w Q MAIN SEWER U DRAWN BY: CHECKED BY: BKR BKR SHEET N0. 5 &A JOB NO. 52790S1 ' <0 PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1 -0 ". IF THE STANDARD. PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE -_ �- INSTALLATION HAS A MORE STRINGENT COVER REQUIREMENT, THE 6 MIN. 6 MIN. MORE STRINGENT REQUIREMENT SHALL GOVERN. CONCRETE CRADLE CLASS "A" W � W I I V I 11 . / -I,,--,`,, I / I-, ol, I I ,�� �,-, I--,-\ . / lo, , \ \ \ / 01 I � � , lo, . . . X, \, 4 .oll Nll��\ t, * .. .. - X "�� . it> * , \\V_i��\ - I-,- .. . . . . . . I "*'�� �\,�>, \__ A . . ,\- �\\\ \� � D, D \ 2500 psi CONCRETE BOTTOM OF TRENCH /� � PIPE BEDDING DETAILS_ NOT TO SCALE MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R-1 916-Fl EAST JORDAN 104522 I 1045V1IT CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, - (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS . SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL, OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). FINISH GRADE " PRECAST CONCRETE ADJUSTING RING N x 24 .13 Q 1 M .. DIA. DOUBLE ROW OF KENT SEAL K, MANHOLE STEPS PER SPECS INFISHIELD "UNIBAND" I - FINISH GRADE INTERIOR JOINTS AND LIFT HOLES ° BUTYL RUBBER • SHALL BE SEALED WITH NON - SHRINK _ • ' GROUT PER SPECS, NO GROUT ABOVE N X TOP OF CONE SECTION V_ Q n--**' ' 4 SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL .: TO ASTM C -443 AND„ ON DOUBLE ROW OF %2" KENT SEAL UNIB NE OR SINGLE ROW OF 1 KENT SEAL UNIBANC 1 } . BUTYL RUBBEI � Z T I ' ~ - � x MANHOLE REINF. PER ASTM SPECS cV PIPE DIA. PER PLAN & PROFILE . I -) s BENCHWALL SHALL BE CLASS "B" CONC. . BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. • i ,f .. MANHOLE TO PIPE CONNECTION BOOTS, INCLUDIN N r- ' LATERALS, SHALL BE A -LOCK, DURA SEAL OR I - I APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL A :; OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN r_ _ _ '%I M `S'� s r � MANHOLES a ' Al vrl In rIrE IN VCR I uEr ins. OF i4 r I. UK GREATER. 4$-On 6" MIN. COMPACTED #8 STONE I.D. SANITARY MANHOLE -TYPE "A" � . "I N 26" SANITARY. MANHOLE R -1642A NOT -TO -SCALE TiOLE 1 TABLE I MINIMUM SPECIFIED TIME REQUIRED FOR A 1.0 psie DROP FOR SIZE AND LENGTH OF PIPE INDICATED Pipe Nlinimum Length for Time for Diameter Time, Minimum Longer Specification Time for Length (L) Shown, mints In. mints Time, ft Length, S 100 ft 150 ft 200 ft 250 ft 300 ft 350 ft 400 ft 450 ft 4 3:48 597 0.360 L 3:46 3:46 3:46 3:46 3:46 3:46 3:46 3:46 6 5:40 386 0.854 L 5:40 5:40 5:40 5AU 5:40 5:40 5:42 6:24 8 7:34 298 1.520 L 7:34 7:34 7:34 7:34 7:36 8:52 10:08 11:24 10 8:26 239 2.374 L 9:28 9:28 9:28 9:63 11:52 13:51 1 15:49 17:48 12 11:20 199 3.418 L 11:20 11:20 11:24 14:15 17:05 19:58 22:47 25:38 16 14:10 158 5.342 L 14:10 14:10 17:48 22:15 26:42 31:09 35:36 40:04 18 17:00 133 7.682 L 17:00 19:13 1 25:38 32:03 26:27 44:52 51:16 57:41. 21 19:50 114 10.470 L 18:60 26:10 34 :54 43:37 52:21 61:00 69:48 78:31 24 22:40 89 13.674 L 22:47 34:11 45:34 56:58 68:22 79:46 91:10 102:33 27 25:30 88 17.306 L 28:51 43:16 57:41 72:07 86:32 100:57 115:22 129:48 30 28:20 80 21.388 L 96:37 53:26 71:13 89:02 108:50 1 124:38 142:25 160:15 33 31:10 72 25.852 L 49:05 64:38 88:10 107:49 129.18 1 150:43 172:21 193:53 38 34:00 I 86 1 30.788 L 1 61:17 76:55 102:12 128:12 153:80 179:29 205:07 230:46 NOT TO SCALE PERSPECTIVE VIEW - EARTH CUT AWAY 0 TO BE USED WHEN CLEAR DISTANCE BETWEEN PIPES IS 18" OR LESS, OR WERE NOTED ON THE DRAWINGS. CONCRETE CRADLE NOT -TO -SCALE EAST JORDAN 104522 1045WT MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R- 1916 -F1 MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R -1642A R- 1916 -F1 CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS -- SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). NOTE: ALL BEDDING & INTAIL BACKFILL SHALL BE INSTALLED IN 6" . TO 12" BALANCED LIFTS DX2 (MAX) TRENCH WIDTH 6" PIPE .12� TAMPED IN PLACE : #8 CRUSHED STONE _\ . . . . . ... . . . ... . . .. . x •. 90� - : . III . El I Wil 6. . l l 1_ .II I 111 II SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE PRECAST CONCRETE ADJUSTING RING DOUBLE ROW OF KENT SEAL . MANHOLE STEPS PER SPECS INTERIOR JOINTS AND LIFT HOLES SHALL BE SEALED WITH NON - SHRINK GROUT PER SPECS, NO GROUT ABOVE TOP OF CONE SECTION SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL TO ASTM C -443 AND ON DOUBLE ROW OF %2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL. MANHOLE REINF. PER ASTM SPECS PIPE DIA. PER PLAN & PROFILE BENCHWALL SHALL BE CLASS "B" CONC. BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. -_ :__ . _ . MANHOLE TO PIPE CONNECTION BOOTS, INCLUDING LATERALS, SHALL BE A -LOCK, DURA SEAL OR APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL AND OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN MANHOLES WITH PIPE INVERT DEPTHS OF 14 FT. OR GREATER. 6" MIN. CONCRETE ENCASEMENT I.D. 6" MIN. COMPACTED #8 STONE SANITARY MANHOLE - TYPE "B" NOT TO SCALE APPROVED SURFACE MARKER iii = iii = iii = iii = iii = iii =iTi =1 I Iii = iii =iii =i UNDISTURBED EARTH NOT -TO -SCALE SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE o MIN. SLOPE SHALL BE >- m Z 0 Cn w Of < LrJ < 0 ** %\ p. R I N,% '''', % �9; �5 •• . �••.••.......••� . , `�� i , �.�j��.., Q-• OG = : • Nos = ' == a . - :1. = * .� . 10200495 : ft. -off STATE OF �� (.c� •''••. //VDIAtNP..••' �C` Gn `.` '�''4' ss�01VAL IN � I_ O N 0 . IJ J LL F-- LJ U - N 0 C.,) Cn = ck� -_ O >_ 04 W cv V) > O Ln d- W Of 0 Ln I =) N Ln .< V) 00 � r-) 00 U 0 co CD 1_1 1` OZ d- r__ O < z � c C,l1 � -- - X N Oct 48 Q) 00 L� - Cn co Oo 4 rn __ CO W M W -° I .. Z O-) N W I Z C � o W o �- W J . L1J Z O i13 ..;j- q _J � � CL LIJ Cn C:) Z I- O up) U (of) J W � O w � D CD Z w O w IIII-iiiiiiiiiiiii- ~ U :D >- I-- (of) W Z = O (.) U < Z < 0 Z I- Z O U Z O I- < Z J w Q MAIN SEWER U DRAWN BY: CHECKED BY: BKR BKR SHEET N0. 5 &A JOB NO. 52790S1 ' CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, - (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS . SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL, OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). FINISH GRADE " PRECAST CONCRETE ADJUSTING RING N x 24 .13 Q 1 M .. DIA. DOUBLE ROW OF KENT SEAL K, MANHOLE STEPS PER SPECS INFISHIELD "UNIBAND" I - FINISH GRADE INTERIOR JOINTS AND LIFT HOLES ° BUTYL RUBBER • SHALL BE SEALED WITH NON - SHRINK _ • ' GROUT PER SPECS, NO GROUT ABOVE N X TOP OF CONE SECTION V_ Q n--**' ' 4 SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL .: TO ASTM C -443 AND„ ON DOUBLE ROW OF %2" KENT SEAL UNIB NE OR SINGLE ROW OF 1 KENT SEAL UNIBANC 1 } . BUTYL RUBBEI � Z T I ' ~ - � x MANHOLE REINF. PER ASTM SPECS cV PIPE DIA. PER PLAN & PROFILE . I -) s BENCHWALL SHALL BE CLASS "B" CONC. . BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. • i ,f .. MANHOLE TO PIPE CONNECTION BOOTS, INCLUDIN N r- ' LATERALS, SHALL BE A -LOCK, DURA SEAL OR I - I APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL A :; OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN r_ _ _ '%I M `S'� s r � MANHOLES a ' Al vrl In rIrE IN VCR I uEr ins. OF i4 r I. UK GREATER. 4$-On 6" MIN. COMPACTED #8 STONE I.D. SANITARY MANHOLE -TYPE "A" � . "I N 26" SANITARY. MANHOLE R -1642A NOT -TO -SCALE TiOLE 1 TABLE I MINIMUM SPECIFIED TIME REQUIRED FOR A 1.0 psie DROP FOR SIZE AND LENGTH OF PIPE INDICATED Pipe Nlinimum Length for Time for Diameter Time, Minimum Longer Specification Time for Length (L) Shown, mints In. mints Time, ft Length, S 100 ft 150 ft 200 ft 250 ft 300 ft 350 ft 400 ft 450 ft 4 3:48 597 0.360 L 3:46 3:46 3:46 3:46 3:46 3:46 3:46 3:46 6 5:40 386 0.854 L 5:40 5:40 5:40 5AU 5:40 5:40 5:42 6:24 8 7:34 298 1.520 L 7:34 7:34 7:34 7:34 7:36 8:52 10:08 11:24 10 8:26 239 2.374 L 9:28 9:28 9:28 9:63 11:52 13:51 1 15:49 17:48 12 11:20 199 3.418 L 11:20 11:20 11:24 14:15 17:05 19:58 22:47 25:38 16 14:10 158 5.342 L 14:10 14:10 17:48 22:15 26:42 31:09 35:36 40:04 18 17:00 133 7.682 L 17:00 19:13 1 25:38 32:03 26:27 44:52 51:16 57:41. 21 19:50 114 10.470 L 18:60 26:10 34 :54 43:37 52:21 61:00 69:48 78:31 24 22:40 89 13.674 L 22:47 34:11 45:34 56:58 68:22 79:46 91:10 102:33 27 25:30 88 17.306 L 28:51 43:16 57:41 72:07 86:32 100:57 115:22 129:48 30 28:20 80 21.388 L 96:37 53:26 71:13 89:02 108:50 1 124:38 142:25 160:15 33 31:10 72 25.852 L 49:05 64:38 88:10 107:49 129.18 1 150:43 172:21 193:53 38 34:00 I 86 1 30.788 L 1 61:17 76:55 102:12 128:12 153:80 179:29 205:07 230:46 NOT TO SCALE PERSPECTIVE VIEW - EARTH CUT AWAY 0 TO BE USED WHEN CLEAR DISTANCE BETWEEN PIPES IS 18" OR LESS, OR WERE NOTED ON THE DRAWINGS. CONCRETE CRADLE NOT -TO -SCALE EAST JORDAN 104522 1045WT MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R- 1916 -F1 MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R -1642A R- 1916 -F1 CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS -- SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). NOTE: ALL BEDDING & INTAIL BACKFILL SHALL BE INSTALLED IN 6" . TO 12" BALANCED LIFTS DX2 (MAX) TRENCH WIDTH 6" PIPE .12� TAMPED IN PLACE : #8 CRUSHED STONE _\ . . . . . ... . . . ... . . .. . x •. 90� - : . III . El I Wil 6. . l l 1_ .II I 111 II SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE PRECAST CONCRETE ADJUSTING RING DOUBLE ROW OF KENT SEAL . MANHOLE STEPS PER SPECS INTERIOR JOINTS AND LIFT HOLES SHALL BE SEALED WITH NON - SHRINK GROUT PER SPECS, NO GROUT ABOVE TOP OF CONE SECTION SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL TO ASTM C -443 AND ON DOUBLE ROW OF %2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL. MANHOLE REINF. PER ASTM SPECS PIPE DIA. PER PLAN & PROFILE BENCHWALL SHALL BE CLASS "B" CONC. BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. -_ :__ . _ . MANHOLE TO PIPE CONNECTION BOOTS, INCLUDING LATERALS, SHALL BE A -LOCK, DURA SEAL OR APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL AND OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN MANHOLES WITH PIPE INVERT DEPTHS OF 14 FT. OR GREATER. 6" MIN. CONCRETE ENCASEMENT I.D. 6" MIN. COMPACTED #8 STONE SANITARY MANHOLE - TYPE "B" NOT TO SCALE APPROVED SURFACE MARKER iii = iii = iii = iii = iii = iii =iTi =1 I Iii = iii =iii =i UNDISTURBED EARTH NOT -TO -SCALE SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE o MIN. SLOPE SHALL BE >- m Z 0 Cn w Of < LrJ < 0 ** %\ p. R I N,% '''', % �9; �5 •• . �••.••.......••� . , `�� i , �.�j��.., Q-• OG = : • Nos = ' == a . - :1. = * .� . 10200495 : ft. -off STATE OF �� (.c� •''••. //VDIAtNP..••' �C` Gn `.` '�''4' ss�01VAL IN � I_ O N 0 . IJ J LL F-- LJ U - N 0 C.,) Cn = ck� -_ O >_ 04 W cv V) > O Ln d- W Of 0 Ln I =) N Ln .< V) 00 � r-) 00 U 0 co CD 1_1 1` OZ d- r__ O < z � c C,l1 � -- - X N Oct 48 Q) 00 L� - Cn co Oo 4 rn __ CO W M W -° I .. Z O-) N W I Z C � o W o �- W J . L1J Z O i13 ..;j- q _J � � CL LIJ Cn C:) Z I- O up) U (of) J W � O w � D CD Z w O w IIII-iiiiiiiiiiiii- ~ U :D >- I-- (of) W Z = O (.) U < Z < 0 Z I- Z O U Z O I- < Z J w Q MAIN SEWER U DRAWN BY: CHECKED BY: BKR BKR SHEET N0. 5 &A JOB NO. 52790S1 ' ' Al vrl In rIrE IN VCR I uEr ins. OF i4 r I. UK GREATER. 4$-On 6" MIN. COMPACTED #8 STONE I.D. SANITARY MANHOLE -TYPE "A" � . "I N 26" SANITARY. MANHOLE R -1642A NOT -TO -SCALE TiOLE 1 TABLE I MINIMUM SPECIFIED TIME REQUIRED FOR A 1.0 psie DROP FOR SIZE AND LENGTH OF PIPE INDICATED Pipe Nlinimum Length for Time for Diameter Time, Minimum Longer Specification Time for Length (L) Shown, mints In. mints Time, ft Length, S 100 ft 150 ft 200 ft 250 ft 300 ft 350 ft 400 ft 450 ft 4 3:48 597 0.360 L 3:46 3:46 3:46 3:46 3:46 3:46 3:46 3:46 6 5:40 386 0.854 L 5:40 5:40 5:40 5AU 5:40 5:40 5:42 6:24 8 7:34 298 1.520 L 7:34 7:34 7:34 7:34 7:36 8:52 10:08 11:24 10 8:26 239 2.374 L 9:28 9:28 9:28 9:63 11:52 13:51 1 15:49 17:48 12 11:20 199 3.418 L 11:20 11:20 11:24 14:15 17:05 19:58 22:47 25:38 16 14:10 158 5.342 L 14:10 14:10 17:48 22:15 26:42 31:09 35:36 40:04 18 17:00 133 7.682 L 17:00 19:13 1 25:38 32:03 26:27 44:52 51:16 57:41. 21 19:50 114 10.470 L 18:60 26:10 34 :54 43:37 52:21 61:00 69:48 78:31 24 22:40 89 13.674 L 22:47 34:11 45:34 56:58 68:22 79:46 91:10 102:33 27 25:30 88 17.306 L 28:51 43:16 57:41 72:07 86:32 100:57 115:22 129:48 30 28:20 80 21.388 L 96:37 53:26 71:13 89:02 108:50 1 124:38 142:25 160:15 33 31:10 72 25.852 L 49:05 64:38 88:10 107:49 129.18 1 150:43 172:21 193:53 38 34:00 I 86 1 30.788 L 1 61:17 76:55 102:12 128:12 153:80 179:29 205:07 230:46 NOT TO SCALE PERSPECTIVE VIEW - EARTH CUT AWAY 0 TO BE USED WHEN CLEAR DISTANCE BETWEEN PIPES IS 18" OR LESS, OR WERE NOTED ON THE DRAWINGS. CONCRETE CRADLE NOT -TO -SCALE EAST JORDAN 104522 1045WT MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R- 1916 -F1 MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R -1642A R- 1916 -F1 CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS -- SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). NOTE: ALL BEDDING & INTAIL BACKFILL SHALL BE INSTALLED IN 6" . TO 12" BALANCED LIFTS DX2 (MAX) TRENCH WIDTH 6" PIPE .12� TAMPED IN PLACE : #8 CRUSHED STONE _\ . . . . . ... . . . ... . . .. . x •. 90� - : . III . El I Wil 6. . l l 1_ .II I 111 II SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE PRECAST CONCRETE ADJUSTING RING DOUBLE ROW OF KENT SEAL . MANHOLE STEPS PER SPECS INTERIOR JOINTS AND LIFT HOLES SHALL BE SEALED WITH NON - SHRINK GROUT PER SPECS, NO GROUT ABOVE TOP OF CONE SECTION SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL TO ASTM C -443 AND ON DOUBLE ROW OF %2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL. MANHOLE REINF. PER ASTM SPECS PIPE DIA. PER PLAN & PROFILE BENCHWALL SHALL BE CLASS "B" CONC. BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. -_ :__ . _ . MANHOLE TO PIPE CONNECTION BOOTS, INCLUDING LATERALS, SHALL BE A -LOCK, DURA SEAL OR APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL AND OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN MANHOLES WITH PIPE INVERT DEPTHS OF 14 FT. OR GREATER. 6" MIN. CONCRETE ENCASEMENT I.D. 6" MIN. COMPACTED #8 STONE SANITARY MANHOLE - TYPE "B" NOT TO SCALE APPROVED SURFACE MARKER iii = iii = iii = iii = iii = iii =iTi =1 I Iii = iii =iii =i UNDISTURBED EARTH NOT -TO -SCALE SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE o MIN. SLOPE SHALL BE >- m Z 0 Cn w Of < LrJ < 0 ** %\ p. R I N,% '''', % �9; �5 •• . �••.••.......••� . , `�� i , �.�j��.., Q-• OG = : • Nos = ' == a . - :1. = * .� . 10200495 : ft. -off STATE OF �� (.c� •''••. //VDIAtNP..••' �C` Gn `.` '�''4' ss�01VAL IN � I_ O N 0 . IJ J LL F-- LJ U - N 0 C.,) Cn = ck� -_ O >_ 04 W cv V) > O Ln d- W Of 0 Ln I =) N Ln .< V) 00 � r-) 00 U 0 co CD 1_1 1` OZ d- r__ O < z � c C,l1 � -- - X N Oct 48 Q) 00 L� - Cn co Oo 4 rn __ CO W M W -° I .. Z O-) N W I Z C � o W o �- W J . L1J Z O i13 ..;j- q _J � � CL LIJ Cn C:) Z I- O up) U (of) J W � O w � D CD Z w O w IIII-iiiiiiiiiiiii- ~ U :D >- I-- (of) W Z = O (.) U < Z < 0 Z I- Z O U Z O I- < Z J w Q MAIN SEWER U DRAWN BY: CHECKED BY: BKR BKR SHEET N0. 5 &A JOB NO. 52790S1 ' NOT TO SCALE PERSPECTIVE VIEW - EARTH CUT AWAY 0 TO BE USED WHEN CLEAR DISTANCE BETWEEN PIPES IS 18" OR LESS, OR WERE NOTED ON THE DRAWINGS. CONCRETE CRADLE NOT -TO -SCALE EAST JORDAN 104522 1045WT MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R- 1916 -F1 MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R -1642A R- 1916 -F1 CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS -- SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). NOTE: ALL BEDDING & INTAIL BACKFILL SHALL BE INSTALLED IN 6" . TO 12" BALANCED LIFTS DX2 (MAX) TRENCH WIDTH 6" PIPE .12� TAMPED IN PLACE : #8 CRUSHED STONE _\ . . . . . ... . . . ... . . .. . x •. 90� - : . III . El I Wil 6. . l l 1_ .II I 111 II SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE PRECAST CONCRETE ADJUSTING RING DOUBLE ROW OF KENT SEAL . MANHOLE STEPS PER SPECS INTERIOR JOINTS AND LIFT HOLES SHALL BE SEALED WITH NON - SHRINK GROUT PER SPECS, NO GROUT ABOVE TOP OF CONE SECTION SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL TO ASTM C -443 AND ON DOUBLE ROW OF %2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL. MANHOLE REINF. PER ASTM SPECS PIPE DIA. PER PLAN & PROFILE BENCHWALL SHALL BE CLASS "B" CONC. BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. -_ :__ . _ . MANHOLE TO PIPE CONNECTION BOOTS, INCLUDING LATERALS, SHALL BE A -LOCK, DURA SEAL OR APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL AND OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN MANHOLES WITH PIPE INVERT DEPTHS OF 14 FT. OR GREATER. 6" MIN. CONCRETE ENCASEMENT I.D. 6" MIN. COMPACTED #8 STONE SANITARY MANHOLE - TYPE "B" NOT TO SCALE APPROVED SURFACE MARKER iii = iii = iii = iii = iii = iii =iTi =1 I Iii = iii =iii =i UNDISTURBED EARTH NOT -TO -SCALE SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE o MIN. SLOPE SHALL BE >- m Z 0 Cn w Of < LrJ < 0 ** %\ p. R I N,% '''', % �9; �5 •• . �••.••.......••� . , `�� i , �.�j��.., Q-• OG = : • Nos = ' == a . - :1. = * .� . 10200495 : ft. -off STATE OF �� (.c� •''••. //VDIAtNP..••' �C` Gn `.` '�''4' ss�01VAL IN � I_ O N 0 . IJ J LL F-- LJ U - N 0 C.,) Cn = ck� -_ O >_ 04 W cv V) > O Ln d- W Of 0 Ln I =) N Ln .< V) 00 � r-) 00 U 0 co CD 1_1 1` OZ d- r__ O < z � c C,l1 � -- - X N Oct 48 Q) 00 L� - Cn co Oo 4 rn __ CO W M W -° I .. Z O-) N W I Z C � o W o �- W J . L1J Z O i13 ..;j- q _J � � CL LIJ Cn C:) Z I- O up) U (of) J W � O w � D CD Z w O w IIII-iiiiiiiiiiiii- ~ U :D >- I-- (of) W Z = O (.) U < Z < 0 Z I- Z O U Z O I- < Z J w Q MAIN SEWER U DRAWN BY: CHECKED BY: BKR BKR SHEET N0. 5 &A JOB NO. 52790S1 ' MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R-1 642A R- 1916 -F1 MANHOLE CASTING SCHEDULE MANUFACTURER SELF SEALING WATERTIGHT NEENAH R -1642A R- 1916 -F1 CASTING SHALL BE EITHER SELF - SEALING OR WATERTIGHT, (SEE PLAN & PROFILE SHEETS FOR CASTING TYPE). LIDS -- SHALL BE STAMPED "SANITARY SEWER" AND HAVE CLOSED PICKHOLES. FRAME SHALL BE SET ON DOUBLE ROW OF 1/2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL (SEE MANHOLE CASTING SCHEDULE). NOTE: ALL BEDDING & INTAIL BACKFILL SHALL BE INSTALLED IN 6" . TO 12" BALANCED LIFTS DX2 (MAX) TRENCH WIDTH 6" PIPE .12� TAMPED IN PLACE : #8 CRUSHED STONE _\ . . . . . ... . . . ... . . .. . x •. 90� - : . III . El I Wil 6. . l l 1_ .II I 111 II SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE PRECAST CONCRETE ADJUSTING RING DOUBLE ROW OF KENT SEAL . MANHOLE STEPS PER SPECS INTERIOR JOINTS AND LIFT HOLES SHALL BE SEALED WITH NON - SHRINK GROUT PER SPECS, NO GROUT ABOVE TOP OF CONE SECTION SET BARREL JOINTS WITH RUBBER TYPE GASKET EQUAL TO ASTM C -443 AND ON DOUBLE ROW OF %2" KENT SEAL OR SINGLE ROW OF 1" KENT SEAL. MANHOLE REINF. PER ASTM SPECS PIPE DIA. PER PLAN & PROFILE BENCHWALL SHALL BE CLASS "B" CONC. BENCHWALL HEIGHT SHALL BE 80% OF PIPE DIA. -_ :__ . _ . MANHOLE TO PIPE CONNECTION BOOTS, INCLUDING LATERALS, SHALL BE A -LOCK, DURA SEAL OR APPROVED EQUAL. PRESS -SEAL, KOR -N -SEAL AND OTHER FLEXIBLE BOOTS SHALL NOT BE USED IN MANHOLES WITH PIPE INVERT DEPTHS OF 14 FT. OR GREATER. 6" MIN. CONCRETE ENCASEMENT I.D. 6" MIN. COMPACTED #8 STONE SANITARY MANHOLE - TYPE "B" NOT TO SCALE APPROVED SURFACE MARKER iii = iii = iii = iii = iii = iii =iTi =1 I Iii = iii =iii =i UNDISTURBED EARTH NOT -TO -SCALE SANITARY SEWER SERVICE CONNECTION NOT -TO -SCALE o MIN. SLOPE SHALL BE >- m Z 0 Cn w Of < LrJ < 0 ** %\ p. R I N,% '''', % �9; �5 •• . �••.••.......••� . , `�� i , �.�j��.., Q-• OG = : • Nos = ' == a . - :1. = * .� . 10200495 : ft. -off STATE OF �� (.c� •''••. //VDIAtNP..••' �C` Gn `.` '�''4' ss�01VAL IN � I_ O N 0 . IJ J LL F-- LJ U - N 0 C.,) Cn = ck� -_ O >_ 04 W cv V) > O Ln d- W Of 0 Ln I =) N Ln .< V) 00 � r-) 00 U 0 co CD 1_1 1` OZ d- r__ O < z � c C,l1 � -- - X N Oct 48 Q) 00 L� - Cn co Oo 4 rn __ CO W M W -° I .. Z O-) N W I Z C � o W o �- W J . L1J Z O i13 ..;j- q _J � � CL LIJ Cn C:) Z I- O up) U (of) J W � O w � D CD Z w O w IIII-iiiiiiiiiiiii- ~ U :D >- I-- (of) W Z = O (.) U < Z < 0 Z I- Z O U Z O I- < Z J w Q MAIN SEWER U DRAWN BY: CHECKED BY: BKR BKR SHEET N0. 5 &A JOB NO. 52790S1 ' (of) J W � O w � D CD Z w O w IIII-iiiiiiiiiiiii- ~ U :D >- I-- (of) W Z = O (.) U < Z < 0 Z I- Z O U Z O I- < Z J w Q MAIN SEWER U DRAWN BY: CHECKED BY: BKR BKR SHEET N0. 5 &A JOB NO. 52790S1 ' rl L_ Ln N O r-I n O O N kD N 0 9 rn -a c� a� E L 0 1 rl 0 00 V i cn i cn O rn n N Ln m L lrn N rl N 0 O N kI N O lry J rn 'v 1t13 ltd i MO 00 't7 O O n (%4 L M r - LLJ In UHUIF l FF1F �. MAY. MIN. �` QE IihfdEG T4GETtiER 4R '�- 1 1IAKNUI.NItlr Attr, UI Ci -�• L'� .l +�r:•.�•f.�:1!•::•i:,?r;= -�i :z •v 1+`:fr�`.";'�'.. _ - - •' ' � •; •.�Lti1 a, r �`IK; .Y�'•.{ t►r raIMLIM 4 24 UCCP IIt .;k - —�`� - 'v.• ftr:'��t, �'f. UTWTY EA.`E404T) — ' t�ASIItJc I WA If R MAV4 41" a0j) I AP 10 HOUSE i DT IC:AI \,�Condults for fritilrc 11111Hy canssinya rnuy Le urstulled utter uriderd ails �j�riUf t0 curb $t pgyrrncnl if desurcl In avoit. lulurr hxrs at 4t5r, DqMt shul be 24" bE;OW Vp of back of curb. NOTES. 1,) All trps, Icltrrul , pushes, bores arid uthcr undcrgrQurd fond rrassirlys Ic:r u;l utilil e� sl-ri,ll be at a minirrrlrm of 4$° below lilt �tuYerireilt 1urfQee to avnL1 Onfl"..tions which wall ckrnai�e tilt un�rickairr 3y5lerrr. 2.) All Ltllitie3 to bC installed under the rOnd or bulb 3lrull be lastalleiJ prig t� the l��Crdrklin; if n Irrnrhinq r:T�erullor� ii Ib t�' J, 64. Jut mqutnf lea the und�'rdrrrn�, l r. rr� ire -M'ed, NO Belo #iinq er Filctiirirtq i0 be, aliowctf the: note! ui arts L, Ubb3.e far utlllty in3trallaticr3 wi,hin Ihr• r /w. In no event shall eutt:n� of the C3tholt binder, ssurfaCr: {x r.rnrlrte. r 11110wed. Hu UriCCiCLttlrlg of in plat[ curb "s will he downd, &fly repai to the uoderdrain sysiem shalt be in,j!CCtCd try the `:cnvt!y,r`x Dttice wtlerr a regulated drain is invcly d, rthr.rwi:,c by till•. Hrunillun Cuunty Fighwoy DiportMe.rit. 4.) ►4'ntrr tr�� & yus tdp FitB shall be tTrac�ulvr bo(1filled to willl IUr !ca lt,r tu}r r1! 1:urt7. u.) Tilts typical di-Aail cpplir only t,,} rare; having lire Fk /W wi4 us�rner7t <t:,arc;tcristics o� shown �n kills T�Inn; f,) All drpft-, trinosurud.Irurrr (up of balk of Cuib. l.) t ?&Wllicari� 14ii1 require it vcriance from tho County Glgirwor. TYPICAL UTILITY LOCATIONS. AND -LOCAL ROAD CROSSING DETAIL NO SCAil F t1AY -26 -2005 WED 11:33 AM 0'717Y TY OF CARMEL FAX ti01 317 5711 2439 P. 04 PrOperty I.ne Sock Of Curb r 5' —C" Slope -41 Graded Qwn l pe % " /ft. j in �' rm .f 1 • , 4" $iQewcix ' : '_ 'r'- 4" Tcp Sc" - � 8ockfili Prtpared Sut)y ►ade TYPICAL SIDEWALK SECTION NOT TO SCALE * THE SPACE BEHIND THE' CURB SHALL BE FILLED WITH SUITABLE MATERIAL TO THE REOUIRED ELEVATION AND COMPACTED IN LAIRS NOT TO EXCEED 6" IN DEPTH. SUBGRADE OR BASE UNDER ALL CURBS, SIDEWALKS, AND DRIVES SHALL DE COMPACTED IN ACCORDANCE WITH SECTION 207.02 OF THE STANDARD SPECIFICATIONS. r— \ C � d O •G N o Spocing Between cu v P N ° > > Transverse Joints r > shell Net Exeesd o o 0 >` 1.25 Times Width = Tea!ed Or Sawec Joints ?4 Thickness �:. • . Clcss •A Concrete •. 4" Knimurn SidCwQlk Uitilt With Drnve,way$ Sna:l Have Minimum Thickness Of p" Or Thickness Of Driveway Which EYer Is Greater. COONCRETF SzDamA. NOT TO SCALE •rawr�•r r r rr , w - - �rr�" � A�� CITY OF CARMEL STANDARDS SIDEWALK DETAILS PMSZD_ 17GURE 10 -14 1.57 HMA #11 SURFACE 2•• HMA #8 BINDER 3" HMA LSD BASE 7° #53 COMPACTED STONE. PREPARED SUBGRADE 1 , _ O„ PAVEMENT COMPOSITION NOTE: ALL PAVING MUST BE COMPLETED IN ONE PAVING SEASON. NOT -TO -SCALE NOTE TO CONTRACTOR, THE CITY OF CARMEL REQUIRES DOUBLE WALL HANCOR H1 –Q SSD PIPE OR EQUAL TO BE USED, Ec-t i C- Sidewclk Surf "-c: ,, - C-.rcr -- e Curb Of CU D 'u' culler Ifeaerant f � I Joe r�• � r�f�•rnbxn• 17� i w:i•:d1�c;.ta�•�c:�7a.1 , jl NI-J c Mir 1b iilSaJ •ti���'� r , w irA -A - Washed Aggccgote z In T-- f 45 ra Jf „r 4. y PI U ERDR.AIN (Typical Instal!- otions) NOTE: PIPE SHIALI- CGt4FORM TO REO,U REMEt--1'TS OF SECTION OF STANDARD SPECIFICATIONS. 1 yf'/TN C Dc-S OF PAVEPiENT VOOENRE REQUIRE"ID INS iA..LrtTI0P1 RE: VYREG : Z! -- B 1HE ENGINEER. Cf 4%f OF CARMEL STANDARDS ANDARDS SUBSURFACE IJpl*t" RT4SED f?SUP.E iff 10 -9 VARIABLE 26' -0" TO 36' -0" FROM CURB TO CURB 2' -0" 10' MIN. 2,_0" 6+ 2 "x8" WOOD RAILS I.S.H.C. SIGN XR -1 ** = K VAL.I WHITE * CLOSED 4 "x4" WOOD POST REFLECTIVE SHEETING 00 zz 17 I ORANGE REFLECTIVE SHEETING EZ _ GRADE LEVEL II III III III III III III III III III III III III III III III 111- 1/4" 0 THRU BOLTS 6" LARGE WITH WASHERS 4 "x4" WOOD POST 0 2 "x4" WOOD BRACES -1 (2 PER POST) `v 2 "x8" WOOD RAILS SANDBAGS 1' -6" 0I 0 ° ) i (MIN. 2 BAGS 1' -0" U-) * * * ** !, 50' MAX PER POST) I I TOP OF CURB GRADE LEVEL 60-0" 1 8 " STEEL PLATES O Z -4 "x4" WOOD POST 4 "x4" WOOD POST ° ° '• �.. . PAVEMENT BOTTOM OF CURB TRANSVERSE EXPANSION JOINTS TRANSVERSE CONTRACTION JOINTS GENERAL NOTES * * * ** WHEN BUILT IN CONJUCTI ON WITH CONCRETE PAVEMENT, EXPANSION 10 ALL WOOD POST AND SUPPORT MEMBERS REFER TO SECTION 800 OF THE INDIANA AND CONTRACTION JOINTS SHOULD BE PLACED AT THE SAME SHALL BE PAINTED WITH TWO (2) COATS STATE HIGHWAY COMMISSIONS STANDARD LOCATIONS AS IN THE PAVEMENT SLABS. THE CURB AND GUTTER OF WHITE PAINT. SPECIFICATIONS AND LATEST ADDITION OF SHOULD BE TIED TO THE PAVEMENT BY 1/2" ROUND DEFORMED BARS (D LOCATION OF BARRICADE AS PER PLANS INDIANA MANUAL OF UNIFORM TRAFFIC AT ABOUT 3 FOOT INTERVALS. IF NO CONCRETE PAVEMENT IS BEING 03 * REFLECTIVE SHEETING TO BE IN ACCORDANCE CONTROL DEVICES. BUILT AT THE TIME THE CURB IS CONSTRUCTED EXPANSION JOINTS WITH I.S.H.C. STANDARD SPECIFICATION 912.10. WHEN THE PROPOSED EXTENSION of THE SHOULD BE PLACED AT THE ENDS OF ALL RETURNS AND AT V ** SEE I.S.H.C. STANDARD DETOUR SIGNS SHT. 3. STREET IS TO BE a) LESS THAN TWO (2) YEARS USE THE SANDBAGS ON POSTS INTERVALS NOT TO EXCEED 50 FEET MAX. CONTRACTION JOINTS SHOULD b) GREATER THAN TWO (2) YEARS USE THE BE INSTALLED AT 10 FOOT SPACING (5 FOOT ON RADII). GROUND POSTS. STANDARD BAR RICADE DETAIL CURB JOINT D w _z J 5' _ 0 "- 1 _ 4' - 0�, SIDEWALK 4" THICK SLOPE 1 4" FT V 4" MIN. GRANULAR MATERIAL TEMPORARY SEEDING SHALL BE DONE IN ACCORDANCE WITH SECTION 621 OF I.D.O.H. SPECIFICATIONS WITHIN THE STREET RIGHT -OF -WAY. NOTE: 6 SUBSURFACE SHALL BE DOUBLE WALL HANCOR HI-0 OR EQUIVALENT. 50' R /W 30' - 0" J TYPICAL STREET CROSS - SECTION NOT -TO -SCALE RESIDENTIAL STREETS ONLY BEDDING, HAUNCHING, INITIAL BACKFILL BEDDING, HAUNCHING AND INITIAL BACKFILL MATERIALS, PLACEMENT AND COMPACTION FOR WATER MAINS, WATER SERVICE LATERALS, SANITARY MAINS AND SANITARY SERVICE LATERALS SHALL BE IN ACCORDANCE WITH THE STANDARD PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE INSTALLATION. FINAL BACKFILL FINAL BACKFILL FOR WATER MAINS, WATER SERVICE LATERALS, SANITARY MAINS AND SANITARY SERVICE LATERALS UNDER AND WITHIN 5 -FEET OF PAVEMENT SHALL BE B- BORROW FOR STRUCTURE BACKFILL MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL BE COMPACTED IN 6 -INCH MAXIMUM LIFTS TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY FOR THE ENTIRE DEPTH OF THE MATERIAL PLACED. THE BACKFILL FOR THE TOP 6- INCHES OF THE EXCAVATION BELOW THE START OF THE AGGREGATE SUBBASE OF THE PAVEMENT SHALL BE NO. 53 STONE MEETING THE MATERIAL REQUIREMENTS OF THE INDOT AND SHALL BE COMPACTED TO NOT LESS THAN 95% STANDARD PROCTOR DENSITY. IF THE STANDARD PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE INSTALLATION HAS A MORE STRINGENT FINAL BACKFILL REQUIREMENT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. MINIMUM COVER FOR PIPE CROSSINGS OF CITY STREETS FOR INSTALLATION OF STORM MAINS, WATER MAINS, SANITARY MAINS, WATER SERVICE LATERALS, SANITARY SERVICE LATERALS UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE UTILITY, THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1 -0 ". IF THE STANDARD PRACTICE OF THE UTILITY THAT HAS JURISDICTION OVER THE INSTALLATION HAS A MORE STRINGENT COVER REQUIREMENT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. RCP STORM SEWER MINIMUM COVER HEIGHTS WHICH ARE LESS THAN THOSE DESCRIBED WILL BE EVALUATED ON A CASE BY CASE CONDITION AND APPROVED ONLY WITH WRITTEN PERMISSION BY THE CITY ENGINEER. 11 W l l l 1 1' -0" R/W TYPICAL SIDEWALK SECTION NOT -TO -SCALE NOTE: 1. ALL TRANSVERSE JOINTS SHALL BE TOOLED OR SAWCUT JOINTS 1/4 THE THICKNESS OF THE CONCRETE SIDEWALK. 2. WALKS ACROSS DRIVEWAYS SHALL BE 6" OR THE THICKNESS OF THE PROPOSED DRIVEWAY WHICHEVER IS THICKER. SOIL —0 5' — o' w z J 3 SIDEWALK 4" THICK SLOPE 1/4" FT. MIN. 3" TOPSOIL " MIN. ROLL CURB &GUTTER 4 GRANULAR TYPE I MATERIAL NOTE: 6" SUBSURFACE SHALL BE DOUBLE WALL HANCOR HI -0 OR EQUIVALENT. NOTE: Contractor shall con tact the Department of En ineerin to g' g schedule a pre – construction mee tin-9 to review the De p artmen i It construction requirements, staff no tlflca Lion requirements, required inspections fo q r certain stages of the work and to re vie w the au th on t y of the Dep artm en t as it relates to work within the existing g an d proposed City right – of– way. S ALegahCarmel RCP Installation Review02 -0 1- O5\ DepartmentoEE✓ngineeringNote.doc NOTE: THAT ALL CONCRETE AND BITUMINOUS MATERIAL PRODUCTION, TRANSPORT AND DELIVERY, PAVING AND PLACEMENT OPERATIONS FOR IMPROVEMENTS LOCATED WITHIN EXISTING OR FUTURE CIT Y OF CARMEL RIGHT–OF–WAY SHALL CONFORM TO THE REQUIREMENTS OF THE INDOT STANDARD AND SUPPLEMENTAL SPECIFICATIONS LATEST EDITION. 6' -0" & 10' -0" SLOPE ASPHALT PATH TO ROAD 1 /4 " /FT. MIN. OR TOWARD TOP OF BANK OF DITCH TYPICAL ASPHALT ASPHALT PATH .PEDESTRIAN PATH X- SECTION 110# SYD. BITUM SURFACE N0. 11. LV ON 220# SYD. BITUM BINDER N0. 81 LV ON 5" COMPACTED AGGREGATE BASE, SIZE N0. 53 M z O I) LU 0 ���•�`�0.R1NEjy Now r 102005: 'o = STATE OF 00 VDIM • • S`SZONAL '''��ttlllft111 ►�,``` 0 \ co N 0 W LL I— W U s i) Z ct: 0 LL_1 Q:f CD O , v En Q (� 0 CD Q0 rn °° I� 0 Q � � V) x N L) to O (y 00 w w z Ln U Z w = '> o 0 _ — J U Z — ~. Ln Q o �- CD 0 W W Z to Q Z O � U Cn J L�J � O w ry D CD Z w U ~ C/) W Z = O U U Q z Q 0 z z O U z O i– Q Z I LJ 1E U DRAWN BY: CHECKED BY: BKR BKR SHEET N0. S &A JOB NO. 52790S1 L M c� G C) O O N 1.O N O c� J 0) .O Q3 O O L 00 V i cn i to O n N Ln i m :i r -:a ;1 'c -1 :•rrr► r= �- fdh .; AC M' LIF V t if sr { l � r� � ' '� r � r v �� • , � � .r � r do Ri 5181 I� r i• -e 44010 � r •° 1 s ; I r► • ! 'R �► r r 4 / k( / k` r / / y I I I a r I I • � a ! a 1 r"_1 a a & • a i * . , • APO - �r _... FY_ _ s: si- -r-r =- _ •rte,o;o!-Io- E a_ T�► .o1E �`�o t o fin rt _o �� �•. r =�' � .. ►�o w .i��. ` o.;t^ o�__ � �+.� � = o �� o .n �� a ��wr� 1 a NFo•' .err � ` �, ,�'"�► ��•• �► r JA t' o (5) TRANSPLAN - t MAPLE — 3" 4 BN '� �\ � (28) TRANSPLA TED � � � JF (4) TRANSPLANIEL��� AR80RVITAE — 10' j j _ _ —� � � I� z � WHITE PINE 7 —8 � — — .—. — — — — � _... / r —� � rJ � �w (9) TRANSPLANTED./ . � i ---- - - - - -- ----- --- - -( � awl 3 SPRUCE 7' -8' ' , 33 � � � � IQ. 0 3� 1 t � �� � � iw Z C. A. j�Z MR ` (3) TRANSPLANTED � I � � � �� E= � BLUE SPRUCE 7'— ') ��` � z X ''' Poll I vi � � Iw (4) TRANSPLANTEDI� BLUE SPRUCE — 7'—$'I I � � � � � E ri XISTING CANOPY TO REMAIN QR 6 No 18 MR 17 (13) TRANSPLANTFD � al BN I ' � � � ( f j �{ WHITE PINES — 7 —}S � � (6) TRANSPLANTE 1 BLUE SPRUCE ac i 31 -ET. SPRUCE i � i � � � i 16 'I 10' LANDSCAPE EASEMENT /TREE PRESERVATION LINE EXIST. EXIST. 1 L SEE i - �-------- - - - -F i TREES EXISTING CANOPY TO REMAIN `� I � � I I j � i i 8 � EXCEPT AS REQUIRED FOR I 1 PROPOSED HOME CONSTRUCTION � I� � I 2� 1 1 15 29 LOT 34 CONSERVANCY LOT � i � i �, `, � 91 I 14 9 I PROPOSED , I .1 DWELLING ♦, 1 I I I I ohl 1 o I I I 41 r 28 ♦ -- — � --! �. WWI � `' -♦ 110000 EXISTING CANOPY TO REMAIN xoe w It WOW, 3 goo / �0' LANDSCAPE EASEMENT EE PRESERVATION LINE NN= 0' -- so= »,� 4 �• �1 ors: l� ;� 1 y V / i�ti .��ri i•.i �1�w, tiRy � I .� .. j , , . ` , ,•� i►. �/' - s '�J ;.. 1, j , �f .x`. ��' � - �- �, l' J � �' }i. � - � ; � ''� �''. � - '� � r� r ! �.� �t.�N �R. • 4� ;yam ,� � `+ � � ,* .- ! � ,, , .i � � r � / � .� cam• j � �� -.� -� '♦ .�t ;YJ +_!1� � .�''r:� � , 't � � �,�11 /�►��. 9�! t 1 t r- � � t„w�t 111 4A I Z_ SIGNAGE AREA ELEVATION f_� - - + 1� �• � �.. r� .r •"r �.r...._ ..way.. .�.�.. - ~~► ��` ~' �". �"'+ y .� �..� w �+�. !� l�� �..� rte. � r � I 13 � r 10 26 , ,� 12 l ` 11 I / EXISTING CANOPY TO REMAIN , (8) TRAN Sp LAN TED WHITE PINES _ 7`_g' I l � ANNUALS SIGNAGE AREA PLAN VIEW, I t 22 f 1 I 2 ! �~ r .� '00F ' j glowl 00000or e C .A. • POND #1 I 23 , 24 1 LANDSr,...Af='1 NO LAN •... � -... ..... �� .� �� _.r ...� ..... ....� ru.- ...... �..� �• �� r.�. •..r. .� .� .fir,.,.. an rr.r...-r 4= am ob-0 .r on r one .....^ir A ow a m ma - M ------ -- am an ....rr w on w. _ -... .....r +�.+.�� �w.r an.rw .��+.� r ...��� rom.•n..► r.l .�. �..w+ .rr w� �+w r -...- �..�.�- �w .�.- rrr w�. r-� w mow.. ...-_ -ter rr •w. �.-� i� r.� �� d.~.� t"a t • i LAN S APE EASEMEN EE PRESE A 0 I EXISTING CANOPY TO REMAIN I � EX4ST1NG FENCE TO REMAIN I I 7 a_ 0 z o< a z x w O o _ ( %3 V wr 0)$0 O z � � Lu r ti > i > sr { do lilt di :•,t� will, a al 0 .� Y t h� t_ i° i; s: k� 1° L� y yT 5. i� 6�• Y' t T, is t s 5' 3'. ALLOW THIN LAYER OF SOIL TO COYER BALL RWT BALL TO BE 113 — 1/2 ABOVE EXISTING GRADE BASIM ON SOIL DRAINAGE r IMPORTED TOP SOIL TV, 1 ♦ i'i i'! r♦ ► M ! t' • -��'! sir! �i.♦ �� .� sir , �l�.! `• %•�:.:: Ionization .. e►i �♦ ��.♦ Air♦ �►�. 1N�4 .,f &X: .�r�:..� ..... - . = • ee re 01 Is. .sue• ss +• .sst •ss. as .s.• •as• ■��a , f 1 1 1 t ,•...Its � .■w .r.w �! �.r. am mill Owns r CONTAINER AND NOT TO SCALE TREE PROTECTION FENCING NOTES 1. Tree protection shall be a minimum of 6-a" high chain fink fence mounted on vertical pipes driven 2'.0' into the ground. at approximately, W-00 to 10 -0' (max.) on center/ with no gates. In areas where super sill fence (SSF) and the free protection fence run parallel, SSF may be Wized for Uee protection purposes upon approval by the County's Urban Forester. 2. "free protection fencing shall be erected at the critical root zone or beyond prior to start of any clearing, grading or other constructlon activity. Signs stating 'No Entry, Tree Protection Area are to be pasted in both English and Spanish. See Reference Detail II.A.5. Trea protection shall not be removed until completion of all construction activity. C! At- nit C/ NM.t 1 ■w.i7V1115V ICAL I• SINGLE OR SPECIMEN TREE I MULTIPLE OR CLUSTERED TREES TREE FR-OTEC0000TION — PLAN \/IEN SCALE: N.T.S. %" / I V LL EVERGREEN PLANTING. DETAIL NOT TO SCALE TREE BACK 4AINING fAL TREE JNG STRING FROM BASE 4 LAYER OF SOIL TO L 1 FOR WATER ACCUMULATION TO BE PROMINENT )LITER EDGE 11TH FOOTPRINT BURLAP i PART COMPOST WITH (]STING SOIL ACK FILL IN BOTTOM w TREE FROTECofTION — ELE\/ATION SCAIZ: KT .9. RUBBER HOSE AT CONTACT POINTS 1/4" NYLON CORD NOTE: PRUNE LOWER BRANCHES OF TREE BACK TO MAIN TRUNK SO THAT REMAINING HEAD IS APPROX. 1/2 OF TOTAL TREE HEIGHT TREE STAKING AND. PLANTING DETAIL N OT TO SCALE WRAP TRUNK OF TREE WITH STANDARD TREE WRAPPING PAPER (CRAPE) STARTING FROM BOTTOM WINDING UPWARDS UNTIE BALLING STRING FROM BASE OF TRUNK ALLOW THIN LAYER OF SOIL TO COYER BALL DEPRESSION FOR WATER ACCUMULATION BERM SIZE TO BE PROMINENT COMPACT OUTER EDGE WITH FOOTPRINT GROUND TREATED STAKES (3 STAKES SPACED EQUIDISTANT) PEEL BACK BURLAP BACK FILL 1 PART COMPOST WITH 5 PARTS QQSTING SOIL COMPACT BACK FILL IN BOTTOM OF HOLE Q � be%) o :5 C 0 C IL to L v CL ft �A TTE .a lj 1 , l� S 111 i 1 CSi ua O o z $ � war o� Q tx DA'fF= v 0 0 SHEET