8'-0" 1. ACCESS TO THE BUILDING SHALL BE PROVIDED AT PRIMARY 9. THERE SHALL BE A LEVEL AND CLEAR FLOOR OR LANDING ON 1 CONCRETE SERVICE AREA, FINISH CS -1 SEE A2.1 1p GREASE TRAP LOCATION- COORD. W/
ENTRANCE(S). EACH SIDE OF A DOOR. THE LEVEL AREA SHALL HAVE A LENGTH IN THE CIVIL, PLUMB. DWGS. 1. 125 PARKING SPACES PREFERRED.
2. WALKS AND SIDEWALKS SHALL HAVE A CONT. COMMON SURFACE DIRECTION OF DOOR SWING OF AT LEAST 60 ", AND THE LENGTH 2 HANDICAP RAMP - SEE DETAIL 12 /A1.1 11 LANDSCAPING - REFER TO LANDSCAPE DWGS.
NOT INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL OPPOSITE THE DIRECTION OF DOOR SWING OF 48" AS MEASURED AT 2. TWO -WAY CIRCULATION REQUIRED, 24' -0" WIDTH MINIMUM (SUBJECT
EXCEEDING 1/2", AND SHALL BE A MINIMUM OF 48" IN WIDTH. RIGHT ANGLES TO THE PLANE OF THE DOOR IN THE CLOSED POSITION. TO LOCAL CODES & ZONING)
w 3. SURFACES WITH A SLOPE OF LESS THAN 6 PERCENT GRADIENT SHALL 10. ALL WALKS WITH CONTINUOUS GRADIENTS SHALL HAVE LEVEL 3
STRIP ACCESS ROUTE 12 PRECAST CONCRETE WHEEL STOPS
BANNER LOGO TO BE AT LEAST AS SLIP RESISTANT AS THAT DESCRIBED AS A MEDIUM AREAS AT LEAST 5 FEET IN LENGTH AT INTERVALS OF AT LEAST EVERY 1 9' -0" x 18' -0" STANDARD PARKING STALL SIZE (SUBJECT TO LOCAL
BE PROVIDED BY
SALTED FINISH. 400 FEET. PROJECT SIGN LOCATION (TO PROVIDE CODES &ZONING)
OWNER _ 4. SURFACES WITH A SLOPE OF 6% GRADIENT OR GREATER SHALL BE 11. ABRUPT CHANGES IN LEVEL, EXCEPT BETWEEN A WALK OR 4 BEST VISIBILITY) SEE DETAIL 3/A1.0. REFER 13 LIMITS OF CONSTRUCTION
" IN TO SPECS SECTION 01530.
SLIP RESISTANT. SIDEWALK AND AN ADJACENT STREET OR DRIVEWAY, EXCEEDING 4 4. PROVIDE SECONDARY EXIT AS REQ'D BY CODE
5. SURFACE CROSS SLOPES SHALL NOT EXCEED 1/4" PER FOOT. A VERTICAL DIMENSION SHALL BE IDENTIFIED BY CURBS PROJECTING 5 HANDICAP SIGN - SEE 6 /A1.1 14 SERVICE RAMP, FINISH CS -1. SEE SHEET A2.1.
q 6. WALKS, SIDEWALKS AND PEDESTRIAN WAYS SHALL BE FREE OF AT LEAST 6" IN HEIGHT ABOVE THE WALK OR SIDEWALK SURFACE TO 5. SERVICE YARD TO BE DARK GREY STAINED CONC.
GRATING WHENEVER POSSIBLE. FOR GRATINGS LOCATED IN THE WARN THE BLIND OF A POTENTIAL DROP OFF. WHEN A GUARDRAIL OR
C MING SOON SURFACE OF ANY OF THESE AREAS, GRID OPENINGS IN THE GRATINGS HANDRAIL IS PROVIDED, NO CURB IS REQUIRED WHEN A GUIDE RAIL IS 6 PAINT HANDICAP SIGN PER 7 /A1.1 15 TOGO SIGN 6. PARKING LOT STRIPING SHOULD BE 4" WIDE FLAT WHITE
ALL LETTERS RED SHALL BE LIMITED TO 1/2" IN THE DIRECTION OF TRAFFIC FLOW. PROVIDED CENTERED 3" (PLUS OR MINUS 1 "), ABOVE THE SURFACE OF SEE DETAIL 17/A1.1
W/ BLACK OUTLINE TRACTOR ARCHITECT ENGINEER 7. WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK THE WALK OR SIDEWALK, THE WALK IS 5 % OR LESS GRADIENT OR NO EXISITING LOCATION OF PAD MTD. 7. HANDICAP SPACES SHOULD BE LOCATED TO PROVIDE
N NAME NAME N EXCEEDS 1 VERTICAL TO 20 HORIZ., IT SHALL COMPLY WITH THE ADJACENT HAZARD EXITS. 7 TRANSFORMER 16 PROPERTY LINE HANDICAP PATRONS DIRECT ACCESS TO PRIMARY
ADDRESS ADDRESS ADDRESS - PROVISIONS OF A PEDESTRIAN RAMP. ENTRY WITHOUT CROSSING DRIVE AISLE.
CITY, STATE CITY, STATE CITY, STATE 8. WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED NO RETAINING WALL BY ANCHOR WALL
8 ASPHALT PAVING -SEE CIVIL DWGS. CONTACT; BRIAN BELASCO 847 - 894 -2186
GREATER THAN 1:2, EXCEPT THAT LEVEL CHANGES NOT EXCEED 1/4" 17 8. PROVIDE CLEAR ACCESS FOR EMERGENCY VEHICLES, DELIVERY
EQ. EQ. EQ. MAY BE VERTICAL. WHEN CHANGES IN LEVELS GREATER THAN 1/2 ", CONC. WALK PER DETAIL 10 /A1.1 (6)U -TYPE BIKE RACKS TO COMPLY PER TRUCKS AND WASTE HAULING VEHICLES.
THEY SHALL COMPLY WITH THE REQ'S. FOR CURB RAMPS. < 9 (COORD. W/ CIVIL) <1 8> ZONNING ORDINANCE CHAPTER 27.06
K
PROJECT SIGN 4 SITE ACCESSIBILITY NOTES
SCALE: 3/4" = l' -0" I SCALE: NONE
5 I SITE PLAN NOTES
SCALE: NONE
6 SITE PLAN DESIGN CRITERIA
SCALE: NONE
1
V)
0 to
Re o
0
01�
U)
p 0,
ON,
U.
a0
Q
Z�w
rW
V
0
CY)
p
..
so
<.—d�
�
W
Lu
u
CL
v)
F=
0
w
t)
Z_
OQ
J
QZ
Z
C�
U
�
Q
Z�
~�
U
mwz
w�
0
F-
F-
F—
W
V)
Lu
_
C
w,,I.Q
w
W
—U
Q
a-
Revisions
PERMIT / PLANNING ISSUE
3/9/07
A
0
0
A
I HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE-
PARED UNDER MY SUPERVISION AND THAT TO THE BEST
OF MY KNOWLEDGE THE SAME COMPLY WITH ALL RULES,
REGULATIONS AND ORDINANCES OF CARMEL, IN
RELATING TO STRUCTURES AND BUILDINGS.
ARCHITECT
Drawn By I Checked By
Scale Date
1" = 20'- 0" 3/9/07
Job No.
07 -4652
Sheet No.
A1.0
0 to
Re o
U)
p 0,
qq
U.
a0
Q
Z�w
arc:
;s0
0
o i0%
= po
� P
C Z - N
V
so
<.—d�
Revisions
PERMIT / PLANNING ISSUE
3/9/07
A
0
0
A
I HEREBY CERTIFY THAT THESE PLANS HAVE BEEN PRE-
PARED UNDER MY SUPERVISION AND THAT TO THE BEST
OF MY KNOWLEDGE THE SAME COMPLY WITH ALL RULES,
REGULATIONS AND ORDINANCES OF CARMEL, IN
RELATING TO STRUCTURES AND BUILDINGS.
ARCHITECT
Drawn By I Checked By
Scale Date
1" = 20'- 0" 3/9/07
Job No.
07 -4652
Sheet No.
A1.0