Loading...
HomeMy WebLinkAboutRCI-MichiganRoad_StampedDrawing.pdfTWO LAYERS - DUGTWRAP FIREMASTER "FASTWRAP-XL"- FlLAMENTTAPE V2" STEEL BANDING 3" LONGINDINAL OVERLAP � 3"PERIMETER OVERLAP EXHAUST DUGT� \� �iremaster "�astwrap-XL" TWO LAYERS - DUGTWRAP FIREMASTER "FASTWRAP-XL" EXHAUST DUGT I/2" STEEL OANDIN6� �� � WALL aR FLOORJ / Sectlon r-e-�000. cnu�K� FIREMASTER FASTWRAP� PAGKING MRTERIAL ��" i" �J� i �iy Detail �I� �0 \Q �I� ry\ � P , ��3" OVERL4P Flrestop Through Wall or Floor Elevation ExHAUST DUGTWORK / o , � � �IREMASTER �ASTWRAP - XL Meets ASTM - E2336 Standards , Gommerclal Kitchen '� Grease Exha�st Duct Gleanout/Access Door Detall � . �i1 LLEANWTOPENIN6� ..// ��y��`_` /\�I� I6 6AUSE AGGE55 DOOR / /��/I // ONE LAYER FIREMASTER "FASTWRAP-�" / `\ ' _i��//1� ALUMINUM TAPE ALL EDGES ONE LAYER FlREMASTER "FASTWRAP-XL"� OVERLAPPED I" ON ALL SIDES / �60" MAXIMUM ON GENTER THREADED ROD HANGERS \ � NUT\ ABOVE AND BELOW � WASHER ABp�/E AND BELOW a^ \ HANGER BRAGKET WELDED TO HOOD TOP 4�� HOODIBODY HOOD MOUNTING DETAIL NO SGALE � I . BEAM GLAMP \ JAM BOLT 3/H" ALLTHREAD STEEL JOIST SP�G I� I GATI ONS HOOD: (U Master Alr Model EH, slzed as shown on the drawings. SYSTEM AGNATION GONTROL and APPLIANGE INTERLOGK�. Gonstrocted of IH gaoge type 304 stainless steel �4 finish, where HooC to indode an "AOto-Start" control system as reqoired by exposed Double thickness outside end panels solld weltled and the Intematlonal Mechanlcal Gode, as adopted by state and pollshed to face r�lth no exposed folnts. Filter rack mollion to be local at�encie>. Gontrol to monitor the dlfferential between room tack welded to Inside end panel. UL. ll0 Listed constroctlon pmblent and hoad Interface temperatwe, actNapng the Nood •365H. system fans if the temperature shauld e eed a preset Ilmit. HOOC� 9y9�em WIII fUT Off 3� (pIOViB9 PfiBY hOOC� tB(O�JEYQtUfB hP9 LI6HT5: (p Flame Gard recessed LED floorescent light fixtore cooled below the preseL IimR. Solid state control to monROr �p L82-I040-L22. UL Listed for vse in Type I canopy noods, factory ko eiyht hood locaqons wiLh all sek point and time dorin9 wred to juncqon bax and switche�. adJustment made at a s�ngle po�nt. WIREWAY GOVER: IH gputje stalnless steel vertlopl wlreway EXHAUST SYSTEM WORK 6Y OTHER TRADES: cove�, centcred on face of haatl. KITGHEN EQUIPMENT GONTRAGTOR: Goordlnate with General, $WITiiHE�J: �Iltlgfl� GO�tf01 9WItGhCS fOY h004) 11gf1�5 qlIC) GXhpV9� EICGtYI4pl, HVAii, pI14) PIVIli�01�g GOlItYqGt GIOGVf�GYItS. fan. Moonted on wlreway cover. GENERAL GONTRAGTOR: Provide wall apenin9. Set in place antl PILTERS: (2) 25'k20'k2" Kason'1002-002520 Aluminum 4apper flaeh wall louvre fornished by the hood system manufacturer. yrease filtere VL. Flle aR13192. STRUGNRAL GONTRAGTOR Frame wall opening as rea�olred. SPAGER: 18 ywge sLainless stcel rear spacer aS 3" wide. Goordlnate foist or sMOCNraI member installatlon to p ovlde reqNred clearances for dvctwork and shaft assemblies. FAN PAGKAGE Exhaust Fan (I) Greenheck madel 5WB-213 UL'162 I f r In I nvlr n If I I w ELEGTRIGAL LONT2AGTOR: Hood 5 stem Re u ents L sted o �se rease aden e o ments. Gentr v a b o er ( ) 9 9 y 0. �r of the rotatable belt tlriven t and s n le width-sin Ie Inlet. Provide 120/60/I 20 am ci�coit fo� hood II hts and controls to P° 9 P 9 y g Blower and ower assembl constrmted of steel. Blower wheel 'onetion box on to of hood. Provide sin le Fase circuit for fan 7 9 J P 9 P ( nstrucLed af non-sparklny aluminum. Fan unit to Include Inlet motor) to d�sconnect switch Extend pawer winny from motor companion flange, draln at lowest polnt of the scroll, acce5s starker pancl fa connectlon point an exhavat fan. Provide door for maintenance, discannecL swRCh, yrease catch pan, and condvit and wiriny from terminal block on hood to terminal block eather c r. Fan dischar9e ta be kop horizanLaL Exterior motor starter panel. Thls work must be In accardance with the SVffpGBS tOV�JB VPIO�C(/ fpG�Ofy StPndPYd BnqmBl fIOISh, N,EG. WALL LOUVRE: ProNCe wall lowre wRh Integ�al plenum box for ELEGIRIGAL GONIRAGTOR (Flre Protection System exhavst dlschar(Je. Lowre to be constrvcted of 18 gaVge welded Reo�vlrements) Provlde condNt and three wlres from terminal S�PIpIE99 9tEEl Wl�h DA fl0bh. PYOVIC�E Q�YQIO QOGi (�YEQ9E LQ�G11 kJIOGk Oh �100(a i0 ITiGYO-9WItGh Of fIYC FJYOiCLt101i 9y9�CIT. pan as snown on drawln9. Loovre to be glven to 6eneral Interlock wirinc� of the svpply alr systams motor control device Gontractor for Installation. throogh the Pire system micro sw¢ch, shuttlny afP supply air -in the BVEYit Of fIYC 9y9�em PG�VQfIOh. E%hpVS� fQ� f0 fBmQlh YVhhl�(� Ih FAN DISGHARGB 10'-O" minimom from any L ilding inlet. the event of flre system activaflon. Fvrnlsh and Install q p" octagon tox Por the P'ire system puu s6atian, moonting the EXHAUST DUGT: I6 gaoge welded black Iron exhaost doct, with centerllne of the box at 4H" above the finished floor. Run I/2" conqn000s I�o�o�d t�ght external welds at all seams and Jaints. only wndNt (w�th no bends) From the top of the box to 6" above Provlde I/4" per Paot minimum slape toward hood on all harizantal khe cetling. If Iretalled in a wall the area around ihe I/2" contlulL duct rms. Provlde cleanoots every 10'-O" of doct length or at shovld be notched or set back to allow the pvlley elbow f�tt�ny ever chan e af d-irection as re vired er code. N 9 � 4 P Por che pou stanon to ee'�nstauea. connecr�ons Por the 4�re system wirinc� most be made in a jmction box on the outside of EXHAVST DUGT WRAP�. Eshaost docts serviny type I hoads shall the fire system cabinet. Pwnish and install avtomatic power shvt be Installed with a rated doct wrap system meePing ASTM E2336 ofP tlevices (shunt trip treakers, or dePlnite pvrpose contactors) Standards, from the point af ceiling penetmqon (or dmt wlth fnterlock to flre syetem mlcro �wltch, shotting off all power nacdon) at the haod, Lo tha terminadon aP the tluct at tha bglow Ehe hood (IncWding control voltage) In the avent of flra exhaost fan (or exit of thc duck Prom the boiltlin9). Thc ducL wrap system actuation. This work musL be in accordance with N.FPA. system shall be Thermal Geramics Rremaster "Fastwrap-xL'l The I'IA, anC the N.EG. duct wrap system shall be installcd in stricL accordance w¢h thc system's listing and the manufacturor's inst�uctions for 2 hoor NIEpHANIGAL GONTRAGTOR: Provide net room air demand as rated sysLem O" clearance ta comWStible and grease dvct intlicated on the hoad sysLem drawinys. Thls a volume is I rekalladon. System requires two layers of 15" uncampressed required only when hood system Is In operatlon. Provide normal Insulatlon. Insulatfon to be banded to the duct wlth steel banding heatiny and coolmg of tha kiECnan area InsEall yas valve (if straps. Penetratlon of rated walls and iloars shall be reclulred, supplled with the fire eoppreselon �ystem) In the maln fire-stopped In accordance with the system manofactorers sopply Ilne serving tFe caoking equlpment ta sFOt off yas service InstallaElon Instrvctlons. to the cooking eo�vlpment In tha avant of flra sysEam actmtlon. FlRE GONTROL SYSTEM: (I) Ansul model R-102, UL 300 Llsted, Ilqoid chemical type. System to provide hood, duct, and reqoired eorface protectioa System InUodes, mechanlcal gae vaNe fif rao�virad, verify yas lina siza), dval micro-sw@ch, and remoLa eQual poll staqan. Pipin9 to be sLainless steel or chrome, where posed. IEEL JOIST NGLE IRON TRAPEZE �"x2"xl/4•' �8" ALLTHREAD Ib" NUT 96" WP.SHER �( EXHAUST DUGT �� INSTALLATION DETAIL � NO SGALE TWO LAYERS FIRE R4TED DUGT WRAP 3" PERIMETER OVERLAP FlLAMENT TAPE /2" STEEL 6ANDIN6 16 6AU6E STEEL EXHAUST DUGT 3/H" ALLTHREAD ANGLE IRON IRAPEZE �"X�"XI/4" 6" MINIMUM PULL HANDLE EXHAUST FAN EP—I 6REENHEGK si"i�-2is Q� HORIZONTAL DISGHAR6E � v GOMMERGIAL KITGHEN EXHAUST FAN U.L'f62 LISTED FOR USE IN 6REA5E LADEN ENVIRONMENTS POWEft VENTILATOR FOR RESTAURANT EXHAUST & YZHW,'163 EXHAUST FAN DISGHARGE 2� �b" EXHAUST FAN EF-I MOTOR ELEG GONNEGTION 2X2 ANGLE HAN6ER5 �_ � a m PLAN VIEW 34 3H" 2'I.O6" DISGHAR6E ��3� � 1VN a� � ______ _____ m p �9 >IA. � b _�I� MOTOR� '_HAN6ER5 �X2 ANGLE HANGERS FRONT ELEVATION SIDE ELEVATION � SPEUFIGATIONS: EXHAUST FAN�. 6reenheck SWB 5erlas cenLrlfogal blower of Lha rotatable belt driven type and singie wlath-single inlet Blower ana power a sembly Lo be constrvcLed of steelSAll s shall be cont'in000sly welded and leakproof. Blower wheel shall ba backwardly Incllned, ilat blade type aM rot�octcd of non-eparking alvmmom. Bearings to be grease obrlcated, anGf�ICGOn ball, plllow block t�ype. Drlves shall be desl9n G for I65& of rated norsapouer,connected witn oil 'i9eone �o�-9tatio xie9. Foo o�¢ to�inclode inlet companion flanye, drain at lowest point of tFe scroll, ss daor for malntanance, d�scon�ect switch, grcase caecl. pan,and wcaLhcr covcr.Fan d'ucharye to be top ho�izontal. Exterior sorfaces to be painted facEOry standard enamel flnlsh. \ HOOD GOMPLIES WITf; U.L. STANDARD "110 ExHA�ST H���S W�THD�T ExHA�ST �AMPERS U I m�s eqm se � L pmen�f Is sultaDle for u w�m cookmy vai�a�ws ae�eiop��q LISTED s��mce temae�oiwes �o m wo'r_ EH MODEL 3658 A Q¢ Moximum deamnce between rnoking suAace ond boftom fmnt edge ol M1oad. B. 4'Z Minimum deomnce between cooking surtace ond baLLam �mnt eaga of Fina_ c. 155 u��umum ri/m�� pe� root of nooa ie�qm des�q� e::naust a�� now- �. N A Maxlmum Ft/min per loot of M1ood IengiM1 design supply alr Ilow. E 160 F. Repioce damDer fusible Ilnks wifM1 UL Listeq ratetl t60'F, 3 to 30 ibs. F- STEEL Repiaoe o�iy w�m u� ciass�rrea qrease nter� spedr'�ea. Sleel or Alum. tor models EHPEL EHL and EHMUAL Sleel only mo0el BVL. G. Hood to extentl tY' pas� equipmen[ unless end cur�alns ara ms[ollea betwean woking equlpment anJ Food bo[tom eage_ H. Hootl mus[ ex�end a ot 6' beyond �M1e tmn� edga of LM1e cooking eqolpm nt sudace_ CONiROL PANEL RATINGS i. uaxlmum aa�aov �'�qncmq soo waue. 120 voiu 60 Ne«= 20.0 amp� MIGRO-SWITGH _ __ -° BLAGK MORMALLY OPEN) � - --- RED (GOMMOW AGTUATING ARM o g(ZpWN (NORMALLY GLOSED) � �� WIRE PLUG IF INSTALLED IN A WALL, THE GABMET SIZE �WALL SHOULD BE NOTGHED OR �P�x PLUG TI6HTLY I65' WIDE SET BAGK TO ALLOW THE PULLEY � 0 AGAINST TERMINALS �SS D EPL ELBOW FITING FOR THE PULL STATION TO BE INSTALLED MIGRO-SWITGH AGENT DISTRI6UTION PIPIN6 GONDUIT AND ELBOWS BY AGENT TANK FlRE SYSTEM INSTALLER PULLEY ELBOW RE6ULATOR .. AGENTTANK WIRING GONNEGTIONS MUSi BE MADE WIRE ROPE IN A JUNGTION 60X OUTSIDE OF THE PIRE SYSTEM GABINET Y.EILIN6 LME GABLE LEVER � 0 E G. TO RI1N V2" ONLY GONDUIT FROM THE TOP OF THE BOX WITH I NO BENDS TO 6" ABOVE THE GEILIN6 � E G. TO PURNISH AND INSTALL A �I 4' OGTA60N BOX FOR THE FlRE j� SYSTEM PULL STATION, MOUNTING i THE GENTERLINE OF THE BOX AT i 4H" ABOVE THE FINISHED FLOOR 0 � MOTE MANVAL � PULN ppLL STATION � � FURNISHED WITH FIRE SYSTEM � _ JI L _ � - � � ?�NSUL R-102 �IRE PROT�GTION SYST�M NO SGALE MOUNTING BRAGKET "ANK 5¢E 24" TALL RELEASE MEGHANISM ENGLOSURE � l5" DIAMETER " O O � NOTE REFERENGE NOTES A. 6eneral GonMactor to c�tovt wall openmy, anC set in place wall lowre. B. SMOCtoral Gontractor to frame wall openmg as reqoired. c. riooa systom wa�ofa�ro�o� to p�o��ao a�a install �16 gauge Polly welded steel eTMaust AVGD. D. ElecSrlcal Gantrackor ko fomish cantrol wiring between hood switch panel and motor starter. E Electncal Gontractor ta fvmish single V�1P9C �JOWEY i0 ITOtOY 9LPfSCY VQYiEI QItCI extcntl from motor sLarter pancl Lo remotc exhaust fan. E 2'k2" Angle eupporb wlth threaded rod hangers. @ Electrical Gontractor to Nrnish control wiring 02o Volt) between micro-swltch in flro VYOCEGLiOh SySCE((i QIiC hOOC SWILGII FJphCI. H. Hoad System ManofacWrer to provlde wall iowre wi«h grease catch pan for exhaost fan discharge. X. Hood System Man�factvrer to provide and iretall a flre rated doct wrap system meeting ASTM - E�336 5tandards and as reqoired by code. EXHAUST PAN EF-I NOTE Nore �n �2 GEILING LME � � '^ p� HANGER BRAGKETS � �i FWORESGENT FlxNRES �, WIREWAY/SWITGHES � HOOD BODY � � 6REASE FILTERS 4, y� 3" REAR SPAGER 3 r �m GREASE GATGH PAN HOOD WIC Q . � GOOKIN6 EQUIPMENT � �� FlNISHED ROOR m ww ELEVATION WITH ++OOD SEGTION SGALE. I/4"--I'O" WIRING GONNEGTIONS MUST 6E MADE IN A JUNGTION BOX q/T51DE OF THE FlRE SYSTEM GABWET RESJLATED RELEASE MEGHANISM UL 300 LISTED LIQUID GHEMIGAL FIRE PROTEGTION SYSTEM AND TANK 5. O ALL EXPOSED PIPEWDRK TO BE STAINLE55 STEEL OR GHROME WHERE EXP05ED. VERIFY LOGATION OF REMOTE MANUAL PULL STATION. UNIT MUST BE PLAGED WITHIN EASY AGGE55 OF EXIT DOOR. MIGRO-SWITGH FURNISHED WITH SYSTEM TO BE WiERWIRED TO THE SHUT-0FF DEVIGES FOR THE GOOKING EQVIPMENT BY THE ELEGTRIGAL GONTRAGTOR. ELEGTRIGAL GONTRAGTOR TO FURNISH AND INSTALL POWER DISGONNEGT DEVIGES FOR ALL EQUIPMENT BELOW THE HOOD, SHUTTIN6 OFF ALL SERVIGE,INGLUDIN6 GONTROL VOLTAGE, UPON AGTIVATIDN OF THE RRE PROTEGTION SYSTEM. ELEGTRIGAL GONTRAGTOR TO FURNISH AND INSTALL AN OGTAGON SHAPED HANDY BOX POR THE PULL STATION AT 4H" ABOVE THE FLOOR WITH I/2" GONDUIT FROM THE TOP OF THE BOx TO 6" ABOVE THE GEILIN6. 6A5 SHUT-0FF VAWE FURNISHED WITH THE SYSTEM OF REQUIRED) TO BE INSTALLED IN THE GAS LWE SERVING THE GOOKING EQUIPMENT BY THE PLUMBIN6 GONTRAGTOR. VERIFY SIZE OF 6A5 LWE. FPCiokY wlwrvc FlEL� WIRMG � (er mneres) FlRE PROTEGTION SYSTEM IN GABMET NOTE '6'� m 3 a a � s o m HOOD LEN6TH . 1�� . 2H" I-Beam , AT 9'-5.5" I —__— _ __—l_— 18" BAR JOIST I EXHAUST FAN'. NOTE NOTE NOTE PLAN VIEW SGALE: I/4"--I'O" FlELD WIkFD BY EQ WHEN REIAOIE MOUME�� m 0 o-p rarv m � 4._qi. \ \ �3" REAR SPAGER \ �GREASE FILTERS r�� �-r+000 ro Fir wirr+iN \ \ EXISTING WLKHEAD �HOOD BODY \� FLUORESGENT FIXNRES I�HOOD LIGHT GONNEGTION � WIREWAY/SWITGHES I I i NOTE NOTE NOTE NOTE NOTE 16"XI6" WALL LOWRE WITH INiE6RAL PLENUM BOX AND GREASE GATGH PAN, 16"XIb" WALL LOWRE WITH INTE6RAL PLEWM BOX � 4 FAN EF-I NOTE 'G' NOTE 'X' �_I4/105 __—_____�_ _________ F 6REA5E GATGHPAN- NOTE A ✓ NOTE 6 J �GE� INE � �� N O� -FLUO�ESGENT FIXNRES ry �i PREGAST �HOOD BODY � EXTERIOR �HOOD TO PIT WITHIN 0 WALL EXISTING &1LKHEAD O � �GREASE GATGH PAN ! y� �GREASE FILTERS � 0 -WIREWAY/SWITGHES � FRONT ELEVATION SGALE I/4"--I'O" _ J-BOx LIGH15 M H00� �20/60/t FOR HOOD LIGMiS FROM PPNEL - SMUNi iRiP BFEAKEF - J-BOx �NiROLLED Br nn�SUL MIGRQSWIiCM N H 140 VOLi '� i POWEft SU4PLY � I SiAR1EF BO% T � � ' �ISCON �SYIITCH io d-sox � yAl C 37 � m m T T � o � f Q T� c ° � _ _ ___ _� fj{� fx� mo �m f f ai n1 I I 95 96 a� o � � � i __ _ ______ _� o 0 d b m� �� MISUL fANNEC11�N5 wiRitiG FROU HOOD i0 I� NOiE LOW VOLiAGE WNiR06 � } WIRES FROM HOOD i0 � FlRE PROTECTION GABwET xOiE LOw MLIPGE COUiR06 TO WIL OF SHUNT TRI4 BRFAKERS oa FlRE PROTECTION TERMINAL BLOCK OF UTIIJiY �I4FIBUrION SYAEM � SiNRTER BO% I FlEL� WIRE FROM NOiE WW VOLTAGE LPINiR015 � � SiAFTEF TO E%HAU4 FAN V / > M EF_, ExxAU4 LaN wiqE rHERUnLLv PROiECiED MOiOR �'�'" 120/60/1 i0 MIGRO-SWITGN IN FiRE PROiEQiON SvSiEu rv0i SNUrvT iRiP COrvTROLLED WIRING DIAGRAM ___ __ __ 10 emmwc riae NO SGALE — — — — - AURM AS REOUIRE� FAN HOOD WALL NPE MAKE MODEL GFM STATIG WEIGHT HP VOLTAGE SERVED OPENING PRKS PHASE EF-I H-I IS"XI8" EXHAUST GREENHEGK SWB213 1,200 H25" 1�3 I/3 120/60/I HOOD HOOD SIZE HOOD EXHAUST EXHAUST EXHAUST EXHAUST ITEM WEIGHT GFM DUGT SIZE DUGT VELOGIN S.P. H-I 4'9"X4'3" 145 1,200 ID"XIO" 1�2H b25" SYSTEM TOTALS EXHAUSTED AIR 1,200 RENRN AIR THRU BVILDING 50URGE5 1,200 EeBI Bf08d $IfBe[ Iidc, Ohlo 49004 9: 614.972.7050 614.972.7049 N 0 � � � i+ ��N O�� � C� � O� ��� OC — r � C �' N � O c � C p O t � a N J � 0 O � C O N � M r O U � � L �' � Z y O j � Z — U°' � �� � � m O � m U rBy, K.BLANDFORD �v���on, Date Drawn: II Feb 2013 �rQ"��g "� RCI H-1