HomeMy WebLinkAbout07040013.3GENERAL (VOTES
GENERAL
1. THE STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE INTERNATIONAL
BUILDING CODE, 2000 EDITION, AND INDIANA BUILDING CODE AMENDMENTS.
2. THE LOADS THAT HAVE BEEN USED IN THE STRUCTURAL DESIGN
INCLUDE THE FOLLOWING:
DEAD LOADS AT PATIO ROOF: 20 PSF
LIVE LOAD AT PATIO ROOF 20 PSF
GROUND SNOW LOAD 20 PSF
SNOW LOAD DESIGN DATA:
1. GROUND SNOW LOAD: 20 PSF
2. SNOW EXPOSURE FACTOR C
3. SNOW LOAD IMPORTANCE FACTOR 1.0
4. THERMAL FACTOR 1.0
5. FLAT ROOF SNOW LOAD 20 PSF
ALL LIVE LOADS HAVE BEEN REDUCED BASED ON TRIBUTARY AREAS IN
ACCORDANCE WITH CODE PROVISIONS AND HAVE BEEN APPLIED TO BOTH
ALTERNATE AND ADJACENT SPANS WHERE APPROPRIATE TO DERIVE
GOVERNING CONDITIONS.
ALLOWABLE STRESSES HAVE BEEN INCREASED BY 1/3 FOR LOADING
COMBINATIONS INCLUDING WIND AND SEISMIC WHERE ALLOWED BY CODE.
DEAD LOADS HAVE BEEN CALCULATED TO INCLUDE THE ACTUAL WEIGHT
OF ALL WORK SHOWN ON THE STRUCTURAL, MECHANICAL, ELECTRICAL
AND ARCHITECTURAL DRAWINGS. NO OTHER EQUIPMENT SHALL BE
PLACED ON OR HUNG FROM THE ROOF SYSTEM WITHOUT PRIOR WRITTEN
APPROVAL OF THE ENGINEER. ROOF- MOUNTED HVAC UNITS SHALL BE
PLACED WITHIN THE DESIGNATED AREAS SHOWN ON THE FRAMING PLANS.
3 COMPLETE SHOP DRAWINGS FOR THE STRUCTURAL WORK SHALL BE
SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO COMMENCEMENT OF
CONSTRUCTION, IN ACCORDANCE WITH THE SPECIFICATIONS. SUCH
REVIEW BY THE ENGINEER DOES NOT RELIEVE THE CONTRACTOR OF FULL
RESPONSIBILITY FOR CORRECT FABRICATION AND CONSTRUCTION OF THE
WORK. THE STRUCTURAL ENGINEER SHALL NOT BE RESPONSIBLE FOR
MATERIALS PURCHASED PRIOR TO REVIEW OF SHOP DRAWINGS.
4. ANY DEVIATION FROM, ADDITION TO, SUBSTITUTION FOR, OR
MODIFICATION TO THE STRUCTURE OR ANY PART OF THE STRUCTURE
DETAILED ON THESE DRAWINGS SHALL BE SUBMITTED IN WRITING TO
THE ENGINEER FOR REVIEW. SHOP DRAWINGS THAT ARE SUBMITTED FOR
REVIEW DO NOT CONSTITUTE "IN- WRITING" UNLESS IT IS CLEARLY
NOTED THAT SPECIFIC CHANGES ARE BEING SUGGESTED.
5. THE CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR
ELEVATIONS NOT SHOWN AND FOR EXACT LOCATIONS OF ALL ARCHI-
TECTURAL DETAILS. THE CONTRACTOR SHALL COMPARE THE STRUCTURAL
AND ARCHITECTURAL DRAWINGS AND REPORT ANY DISCREPANCIES TO
THE ENGINEER PRIOR TO COMPLETION OF THE SHOP DRAWINGS.
6. THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL
DIMENSIONS AND CONDITIONS AT THE SITE AND SHALL NOTIFY THE
ENGINEER OF ANY DISCREPANCIES BETWEEN THE ACTUAL CONDITIONS
AND INFORMATION SHOWN ON THE DRAWINGS BEFORE PROCEEDING WITH
THE WORK.
7. PRINCIPAL OPENINGS ARE SHOWN ON THE STRUCTURAL DRAWINGS.
CONTRACTOR SHALL REFER TO ARCHITECTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS FOR SLEEVES, CURBS, INSERTS AND OTHER
OPENINGS NOT SHOWN. THE CONTRACTOR SHALL PROVIDE FOR ALL
OPENINGS, WHETHER SHOWN ON THE STRUCTURAL DRAWINGS OR NOT.
SIZE AND LOCATION OF ALL OPENINGS SHALL BE VERIFIED BY THE
CONTRACTOR. ANY DEVIATION FROM OPENINGS SHOWN ON THE
STRUCTURAL DRAWINGS SHALL BE BROUGHT TO THE ENGINEER'S
ATTENTION FOR APPROVAL PRIOR TO CONSTRUCTION.
8. THE STRUCTURAL DRAWINGS ARE NOT TO BE SCALED FOR
DETERMINATION OF QUANTITIES, LENGTHS, OR FIT OF MATERIALS.
9. THE STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE
FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHODS OF
CONSTRUCTION UNLESS SO STATED OR NOTED. THE CONTRACTOR SHALL
PROVIDE ALL MEASURES NECESSARY TO PROTECT THE WORKMEN AND
OTHER PERSONS DURING CONSTRUCTION.
10. THE CONTRACTOR SHALL PROVIDE TEMPORARY ERECTION BRACING
AND SHORING OF ALL STRUCTURAL WORK AS REQUIRED FOR STABILITY
OF THE STRUCTURE DURING ALL PHASES OF CONSTRUCTION. THE
CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY
CONDITION WHICH, IN HIS OPINION, MIGHT ENDANGER THE STABILITY
OF THE STRUCTURE OR CAUSE DISTRESS IN THE STRUCTURE.
11. CONSTRUCTION MATERIALS SHALL NOT BE STORED ON FLOORS OR
ROOFS IN EXCESS OF THE DESIGN LIVE LOADS WHICH ARE INDICATED
ON THE DRAWINGS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO
ENFORCE THIS REQUIREMENT. IMPACT SHALL BE AVOIDED WHEN
PLACING MATERIALS ON FLOORS OR ROOFS.
12. CONSTRUCTION SEQUENCE SHALL BE COORDINATED BY THE CONTRACTOR
AS REQUIRED FOR INSTALLATION OF ALL STRUCTURAL COMPONENTS.
13. FIELD INSPECTION REPORTS SHALL BE SUBMITTED TO THE ENGINEER
AS OUTLINED IN THE SPECIFICATIONS. INSPECTIONS SHALL BE
PROVIDED BY A QUALIFIED AGENCY HIRED BY THE OWNER.
CAST IN PLACE REINFORCED CONCRETE
1. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE MOST RECENT
EDITION OF ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE ".
2. STEEL REINFORCING BARS SHALL CONFORM TO ASTM A -615, GRADE 60.
EXCEPT WELDED REINFORCEMENT SHALL CONFORM TO ASTM A -706. REINFORCE-
MENT SHALL NOT BE WELDED UNLESS SHOWN ON THE DRAWINGS.
3. ALL CONCRETE SHALL UTILIZE NORMAL WEIGHT AGGREGATE UNLESS NOTED
OTHERWISE.
4. MIXES SHALL BE DESIGNED TO PROVIDE CONCRETE WITH A 28 DAY
COMPRESSIVE STRENGTH OF 4500 PSI AND A MAXIMUM WATER:CEMENT
RATIO OF 0.45.
5. ALL EXTERIOR CONCRETE SHALL BE AIR - ENTRAINED. AIR CONTENT SHALL BE
3%-6%. INTERIOR SLABS SHALL NOT HAVE AIR - ENTRAINMENT.
6. CONCRETE SLUMPS SHALL BE AS FOLLOWS:
CONCRETE CONTAINING SUPERPLASTICIZER 8" MAX.
ALL OTHER CONCRETE 3 " -5"
CONCRETE SLUMPS GIVEN ARE AT THE POINT OF PLACEMENT.
7. THE TESTING LABORATORY SHALL BE NOTIFIED AFTER THE MILD STEEL
REINFORCEMENT AND EMBEDS ARE POSITIONED PRIOR TO EACH CONCRETE
PLACEMENT. NO CONCRETE SHALL BE PLACED UNTIL THESE ITEMS ARE
CHECKED AND APPROVED BY THE TESTING LABRATORY.
STEEL
1. STRUCTURAL STEEL SHALL BE NEW STEEL AND SHALL CONFORM TO THE
A.1-S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION
OF STRUCTURAL STEEL FOR BUILDINGS."
2. ALL STEEL SHALL CONFORM TO ASTM A -36, U.N.O.
3. ALL STRUCTURAL STEEL CONNECTIONS AND DETAILS SHALL CONFORM TO THE
A.I.S.C. "CODE OF STANDARD PRACTICE FOR STEEL, BUILDINGS AND
BRIDGES."
4. WELDED CONSTRUCTION SHALL CONFORM TO AWS D -1.1, "STRUCTURAL
WELDING CODE." WELDING PROCESSES AND OPERATORS SHALL BE
QUALIFIED IN ACCORDANCE WITH AWS "STANDARD QUALIFICATIONS
PROCEDURE." ELECTRODES FOR FIELD AND SHOP WELDS SHALL BE E70XX,
U.N.O.
5.STEEL MEMBERS SHALL NOT BE SPLICED EXCEPT AS SHOWN ON THE
DRAWINGS.
WOOD CONSTRUCTION
1. PREPARATION, FABRICATION, AND INSTALLATION OF WOOD MEMBERS AND
FASTENING SHALL CONFORM TO ACCEPTED ENGINEERING PRACTICES AND TO
THE REQUIREMENTS OF THE BUILDING CODE. WORK SHALL BE PERFORMED
BY EXPERIENCED FABRICATORS.
2. WOOD FRAMING MATERIALS:
A. ALL WOOD FRAMING SHALL BE NO. 2 DOUGLAS -FIR OR NO. 2 SOUTHERN
PINE WITH A MINIMUM ALLOWABLE BENDING Fb =900 PSI AND A MINIMUM
ALLOWABLE SHEAR Fv =90 PSI.
3. CONNECTIONS:
A. THE FRAMING CONTRACTOR SHALL FURNISH ALL HARDWARE REQUIRED TO
MAKE CONNECTIONS BETWEEN VARIOUS ELEMENTS.
B. ALL CONNECTIONS NOT SPECIFICALLY DETAILED SHALL UTILIZE JOIST
HANGERS, BEAM HANGERS, CONNECTORS, COLUMN BASES, ETC. THIS
HARDWARE SHALL BE MANUFACTURED BY SIMPSON COMPANY AND SHALL BE
SELECTED AND INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS.
C. ALL BOLTED CONNECTIONS SHALL HAVE WASHERS AT BOLT HEAD AS WELL
AS AT THE NUT.
D. FASTENERS AND CONNECTORS IN CONTACT WITH PRESSURE TREATED
WOOD SHALL BE STAINLESS STEEL (TYPE 316L), HOT- DIPPED
GALVANIZED (G185 HDG PER ASTM A653), BATCH /POST HOT -DIP
GALVANIZED (PER ASTM A123 FOR CONNECTORS AND ASTM A153
FOR FASTENERS), OR MECHANICALLY GALVANIZED (PER ASTM 8695,
CLASS 55 OR GREATER). CONNECTORS AND FASTENERS SHALL BE
MADE OF THE SAME MATERIAL (EITHER STAINLESS STEEL OR
HOT -DIP GALVANIZED).
E. ALL NAILS CALLED OUT ON PLANS SHALL BE "COMMON NAILS ",
UNLESS NOTED OTHERWISE.
8d: 0.131" x 2.50" 12d: 0.148" x 3.25"
10d: 0.148" x 3.00" 16d: 0.162" x 3.50"
2x BLOCKING COPED
TO MATCH SLOPE -
2 -4x12
CEDAR MEMBERS
CL OF COL., GLIB &
STOREFRONT
EXIST. 8 1/2"x15" GLB
(VERIFY) IF NOT PRESENT
PROVIDE MIN_ 2 -2x12
NO. 2 SOUTHERN
YELLOW PINE I\
##4 ® 24" O.C.
GRADE
REF. ARCH.
CO�z
II-
o-
J
v
0
cV
REINF. FTG.
w/ 2 - #5 CONT.
& #4 ® 18" Q.C.
I.
SECTION
1 SCALE: 3/4 " =1' -0"
CONCENTRATED LOAD
BTWN. PANEL POINTS
/nnn H nn nor A Trn\
STOREFRONT
REF. ARCH.
STONE CAP
REF. ARCH.
8" CMU WALL
FULLY GROUT ALL CELLS
EXIST. SLAB
ON GRADE-
EACH SIDE
GRE TER HAN
R = " CONCENTRATED LOAD
IF BTWN. PANEL POINTS
(200## OR GREATER)
PANEL POINT REINFORCING AT JOIST
TYPICAL SECTION.
SCALE: 3/4"=11'-O"
POINT LOAD BRACE-
REF SECTION 3/S1.0
ADD 1 1/2" THICK W000 I FOR RO oATIONS REFER TO I
BLOCKING UNDER UNIT ROOF PLAN
CURBS AT JOISTS, VERIFY I I
CURBS OR UNIT RUNNERS
SPAN JOIST TO JOIST L-r" ----- - - - - -n
JOIST REINF. AT
CURB SUPPORT
REF. 2/S1.0 -
1/4- GUSSET PL
I �
II �
EXIST. FRAMING
1/2" DIA.
x L/2
ROD
® SPAN -
CENTER T.
& B.
EA.
SIDE.
REINFORCING AT JOIST
SCALE: 3/4 " =1' -0'
NOTE: SHORE JOIST PRIOR TO WELDING.
3/16
L3x3x3/16 CONT. REQ'D.
AROUND OPENING
6 V �- L5x3x1 /4 (LLV) BTWN.
STL. JOIST OR STL. BEAM
® 5' -0" O.C. MAX.
(FLUSH w/ BOTTOM OF DECK)
EXISTING
STL. JOIST
ROOF OPENING FRAME
TYPICAL SECTION.
SCALE: 3/4 " =1' -0"
EXIST. MTL.
ROOF DECK
z 6" WELD
z EA. END
Q
Q
z
W
U
i
LiJ
U
Q
LiJ
I-
Q
J
U
2 -23 -07 ISSUED FOR
PERMIT
12 -7 -06 LANDLORD
REVIEW
No Date Remarks
REVISIONS
Drawing Title
GENERAL NOTES
& DETAIL
Job No. Drawn
061472 GF
E Date
2/23/07
Sheet No.
S1.0
Q,% a n M
x
�Crqd � a: v
• U , Nu
m
`.1
O 0
1..03
r� SO
Y
W
N N
O
z
N
0
UL
c�
Ir
4
Ir
O
Q
Q
z
W
U
i
LiJ
U
Q
LiJ
I-
Q
J
U
2 -23 -07 ISSUED FOR
PERMIT
12 -7 -06 LANDLORD
REVIEW
No Date Remarks
REVISIONS
Drawing Title
GENERAL NOTES
& DETAIL
Job No. Drawn
061472 GF
E Date
2/23/07
Sheet No.
S1.0