Loading...
HomeMy WebLinkAbout07070040-43 Landscape Plan plotted 9/6/2007 Rcv. 9/11/2007 DOCSat HOSE GUARDS AND GUY WIRE - , GUY TREES 9' HT. AND TALLER. USE--,, ORN. TREES 2"x 4" STAKES DRIVEN BELOW GRADE. A r 3 STAKES @ 120' APART 3 - 9 B 5 10 3 3 SET TOP OF ROOT CROWN 4" ABOVE C 10 FINISH GRADE 3 4 CUT ALL BINDING AND REMOVE WRAPPING D f = FROM TOP OF BALL S ` - 3" MULCH LAYER AS SPECIFIE — 4 DIA. X 4 SAUCER AROUND PLANTING PIT ----- - - - - -- CONTOURS - KR INTERVAL PULVERIZE SOIL EXCAVATED FROM HOLE B. L. BUONG SETBACK LINE D.U. &S.E. DRAW[ W AM SEWER [UP D.U. &S. S. E. AND USE AS BACKFILL N.A.E. & S.W.E. ' LOOSEN SUBGRADE AROUND CENTER MOUND\ AND INSTALL SAND AS NEEDED TO PROVIDE ADEQUATE DRAINAGE AND AERATION \ \ STAKE TO BE 18" BELOW PIT IN UNDISTURBED SUBGRADE (SET 120' APART) UNDISTURBED SUBGRADE BASE EVERGREEN TREE PLANTING DETAIL NO SCALE W SHRUB PLANTING NO SCALE ROOTBALL -STAKE TREES UP TO 8' HEIGHT. 3 STAKES 0 120' APART EXCAVATE HOLE 12" LARGER THAN ROOT BALL SCARIFY SIDES OF HOLE NISH GRADE • " 3" shredded hardwood bark mulch 3" high topsoil saucer for individual plants. NOTE: Remove burlap from top 1/3 of root ball or carefully remove container. Refer to plans for finish grade. Slope & scarify sides of pit. Width of pit to be three times ball diameter. Excavated soil or topsoil backfill. Set root ball on undisturbed soil "cone" at bottom of pit. 12 GUAGE WIRE (TYP. OF 3) r SAUCER `. TREE NOTE: LOCATE 1 STAKE DIRECTLY SOUTHWEST OF TREE TRUNK TREE STAKING DETAIL NO SCALE METAL STAKE (TYP. OF 3) MULCH PLY HOSE 41t; t 311N Rebar Found Current Owr�6r: Potrick Sullivan per Inst. No. 200000032459, o" Rebar Found 011 do 0.2N 1 I I � CU J L CU a 0 0 I � I > T v O v 0 ca .� v 0 L CL rn LANDSCAPE PLAN CHESTERTON WOODS 9.00± ACRES ZONED: S -2 LANDSCAPING NOTES: The exisitng property is heavily wooded with lush vegetation and growth that will be used whenever feasible and is planned for maximum conservation of the existing vegetation. the following ordinance shall govern the proposed development. 26.04 Perimeter Buffering Requirements. 26.04.01 The requirements of this Section shall apply to all Special Uses, Subdivision Plats, properties containing multi - family uses, and properties within all Business, Manufacturing, and Industrial districts, unless other buffer or perimeter planting standards are specified within an individual district or zone. 26.04.02 Where required, perimeter buffering shall be located along the front, side and rear lot lines of a lot/parcel and shall extend the entire length of the front, side and rear lot lines. 26.04.03 Where residential or other buildings back onto a public thoroughfare, buffer plantings shall occur outside of the public right-of-way, per the Tables below. 26.04.04 Perimeter buffering shall not be located within any portion of a dedicated public street right- ofway, private street right-of-way, or County regulated drain easement. 26.04.05 Existing vegetation may be used to achieve project buffering if: (a) the vegetation located upon the subject parcel is of a quality and state of health to achieve buffering, and, (b) the vegetation is proposed to be preserved using accepted best management practices for tree protection during construction. 26.04.06 To determine the applicable bufferyard requirements: (a) Use the Table for Bufferyard Determination to identify the land use category of the proposed project use. (b) Use the Table for Bufferyard Determination to identify the land use(s) of the adjoining properties, or identify the street classification adjoining the proposed use by referring to the Official Thoroughfare Plan of Carmel -Clay Township. (c) Determine the bufferyard(s) required on each boundary (or segment thereof) of the subject parcel by referring to the Table for Bufferyard Determination. Bufferyard Design Standards in the table below are stated in terms of minimum width and number of plants required per one hundred linear foot increment. BUFFER YARD MINIMUM YARD WIDTH FRONT & SIDE REAR SHADE TREES ORN. TREES SHRUBS A 5' 10' 3 2 9 B 5 10 3 3 15 C 10 20' 3 4 21 D 15' 25' S 5 27 PDINT OF pen of .TT�.73751 Sec. 7 — T17N — RK Mag Nail �VHD �''� "� Found and Field OVH 4� N89' 17'00"W - 352.00' E:. 16' i i hh `o o` CD ° z L6 CD L: d• a> c � c — CD o o o `r✓ 0 U O o EL � C) V) Z Q I I Lo Group, S Li r- v e y o r s Engineers Architects 433 West Carmel Drive Phone: 317.844.3333 Carmel, IN 46032 Fax: 317.844.3383 www.SEAGroupLLC.com PROJECT ADDRESS: 2405 EAST 99TH STREET CARMEL, IN 46032 PROJECT LOCATED IN: � SECTION 07 - TOWNSHIP 11 NORTH -RANGE 04 EAST i CLAY TOWNSHIP, HAMILTON COUNTY 04 W v CD o I can m o > o ca o = CD I07 SW% Mft Coma Sec. 7 — T1 7N — R4E M09 Nat Found and Feld (IN FEET) 1 inch = 50 ft. LANDSCAPE PLAN PREPARED FOR: 56TH DEVELOPMENT Attn: MARK HUMPHREY 865 West Carmel Drive S116 Carmel, IN 46032 Office 317.805.4663 Fax 317.805.7361 � REV. # I DATE IREV. DESC. 1 1 8/8/07 1 REV. PER TAC COMMENTS. DRAWING LEGEND WTR WIN'< EXITING WATER LNE w,:R ev;R "IR01D WATER Lk" D-- — — -- — — — —® PROP. STORM SEWR FIRE HYDRANT PROP. SIVIiARY SEWER low SAN EX. SAN = UNDERGR(XJND SANfiARY SINER —aro —ate — � = OVERTIDAD U11J1Y — — — — DC ROX = RW OF WAY (AS NOTED) — — — — PROP. R.O.W. = W OF WAY (AS NOTD) — — CEN11 W AS NOTED --- -- - --- -- B.L= HDINCSETBACKX ------------ - - - - -- EAW (AS NOTED) CONC. CURB (AS NOTED) DC SPOT DRAIN X — CONTOURS - WEIR INTERVAL ----- - - - - -- CONTOURS - KR INTERVAL PROPOSED CONTOUR - 1 FOOT INfE k B. L. BUONG SETBACK LINE D.U. &S.E. DRAW[ W AM SEWER [UP D.U. &S. S. E. MJAGE OR AND SANITARY SEWER M N.A.E. & S.W.E. NON ACCESS AND SIDEWALK EASEMENT SYMBOL LEGEND cD-.) OVERHEAD UTILITY POLE MT WATER METER FIRE HYDRANT O SURVEY MARKER FOUND ® DRAINAGE INLET Wv WATER VALVE SIGN O WELL GMTR V V GAS METER 070700 0-'/J Approved By: BCR/TJW Drawn By: TJW Date of Last Field Work: 06/13/07 Date Plotted: 09/06/07 Reference #: Project Number: C7 -1357 Sheet Number: 3 of 3