HomeMy WebLinkAbout07070040-43 Landscape Plan plotted 9/6/2007 Rcv. 9/11/2007 DOCSat
HOSE GUARDS AND GUY WIRE
- ,
GUY TREES 9' HT. AND TALLER. USE--,,
ORN. TREES
2"x 4" STAKES DRIVEN BELOW GRADE.
A
r
3 STAKES @ 120' APART
3
-
9
B
5
10
3
3
SET TOP OF ROOT CROWN 4" ABOVE
C
10
FINISH GRADE
3
4
CUT ALL BINDING AND REMOVE WRAPPING
D
f =
FROM TOP OF BALL
S
`
-
3" MULCH LAYER AS SPECIFIE
—
4 DIA. X 4 SAUCER AROUND PLANTING PIT
----- - - - - --
CONTOURS - KR INTERVAL
PULVERIZE SOIL
EXCAVATED FROM HOLE
B. L.
BUONG SETBACK LINE
D.U. &S.E.
DRAW[ W AM SEWER [UP
D.U. &S. S. E.
AND USE AS BACKFILL
N.A.E. & S.W.E.
'
LOOSEN SUBGRADE AROUND CENTER MOUND\
AND INSTALL SAND AS NEEDED TO PROVIDE
ADEQUATE DRAINAGE AND AERATION
\ \
STAKE TO BE 18" BELOW PIT IN
UNDISTURBED SUBGRADE
(SET 120' APART)
UNDISTURBED SUBGRADE BASE
EVERGREEN TREE PLANTING DETAIL
NO SCALE
W
SHRUB PLANTING
NO SCALE
ROOTBALL
-STAKE TREES UP TO
8' HEIGHT. 3 STAKES
0 120' APART
EXCAVATE HOLE 12" LARGER
THAN ROOT BALL
SCARIFY SIDES OF HOLE
NISH GRADE
• "
3" shredded hardwood bark mulch
3" high topsoil saucer for
individual plants.
NOTE: Remove burlap from top 1/3 of
root ball or carefully remove container.
Refer to plans for finish grade.
Slope & scarify sides of pit.
Width of pit to be three
times ball diameter.
Excavated soil or topsoil backfill.
Set root ball on undisturbed soil "cone"
at bottom of pit.
12 GUAGE WIRE
(TYP. OF 3) r
SAUCER
`. TREE
NOTE: LOCATE 1 STAKE DIRECTLY
SOUTHWEST OF TREE TRUNK
TREE STAKING DETAIL
NO SCALE
METAL STAKE
(TYP. OF 3)
MULCH
PLY HOSE
41t; t
311N
Rebar Found
Current Owr�6r:
Potrick Sullivan
per Inst. No.
200000032459,
o"
Rebar Found
011 do 0.2N
1 I
I �
CU
J
L
CU
a
0
0
I �
I
> T
v
O
v
0
ca
.� v
0 L
CL
rn
LANDSCAPE PLAN
CHESTERTON WOODS
9.00± ACRES
ZONED: S -2
LANDSCAPING NOTES:
The exisitng property is heavily wooded with lush vegetation and growth that will be used
whenever feasible and is planned for maximum conservation of the existing vegetation. the following
ordinance shall govern the proposed development.
26.04 Perimeter Buffering Requirements.
26.04.01
The requirements of this Section shall apply to all Special Uses, Subdivision Plats, properties
containing multi - family uses, and properties within all Business, Manufacturing, and Industrial
districts, unless other buffer or perimeter planting standards are specified within an individual
district or zone.
26.04.02
Where required, perimeter buffering shall be located along the front, side and rear lot lines of a
lot/parcel and shall extend the entire length of the front, side and rear lot lines.
26.04.03
Where residential or other buildings back onto a public thoroughfare, buffer plantings shall occur
outside of the public right-of-way, per the Tables below.
26.04.04
Perimeter buffering shall not be located within any portion of a dedicated public street right- ofway,
private street right-of-way, or County regulated drain easement.
26.04.05
Existing vegetation may be used to achieve project buffering if:
(a) the vegetation located upon the subject parcel is of a quality and state of health to achieve
buffering, and,
(b) the vegetation is proposed to be preserved using accepted best management practices for
tree protection during construction.
26.04.06
To determine the applicable bufferyard requirements:
(a) Use the Table for Bufferyard Determination to identify the land use category of the
proposed project use.
(b) Use the Table for Bufferyard Determination to identify the land use(s) of the adjoining
properties, or identify the street classification adjoining the proposed use by referring to
the Official Thoroughfare Plan of Carmel -Clay Township.
(c) Determine the bufferyard(s) required on each boundary (or segment thereof) of the
subject parcel by referring to the Table for Bufferyard Determination.
Bufferyard Design Standards in the table below are stated in terms of minimum width and
number of plants required per one hundred linear foot increment.
BUFFER YARD
MINIMUM YARD WIDTH
FRONT & SIDE REAR
SHADE TREES
ORN. TREES
SHRUBS
A
5'
10'
3
2
9
B
5
10
3
3
15
C
10
20'
3
4
21
D
15'
25'
S
5
27
PDINT OF
pen of .TT�.73751
Sec. 7 — T17N — RK
Mag Nail
�VHD �''� "� Found and Field
OVH
4� N89' 17'00"W - 352.00'
E:. 16'
i
i
hh `o
o`
CD °
z
L6
CD
L:
d• a> c
� c —
CD
o
o
o `r✓
0 U O
o EL �
C) V)
Z Q
I
I
Lo
Group,
S Li r- v e y o r s
Engineers Architects
433 West Carmel Drive Phone: 317.844.3333
Carmel, IN 46032 Fax: 317.844.3383
www.SEAGroupLLC.com
PROJECT ADDRESS:
2405 EAST 99TH STREET
CARMEL, IN 46032
PROJECT LOCATED IN:
� SECTION 07 - TOWNSHIP 11 NORTH -RANGE 04 EAST
i CLAY TOWNSHIP, HAMILTON COUNTY
04
W v
CD
o I can
m
o >
o ca
o =
CD I07
SW% Mft Coma
Sec. 7 — T1 7N — R4E
M09 Nat
Found and Feld
(IN FEET)
1 inch = 50 ft.
LANDSCAPE
PLAN
PREPARED FOR:
56TH DEVELOPMENT
Attn: MARK HUMPHREY
865 West Carmel Drive S116
Carmel, IN 46032
Office 317.805.4663
Fax 317.805.7361
� REV. # I DATE IREV. DESC.
1 1 8/8/07 1 REV. PER TAC COMMENTS.
DRAWING LEGEND
WTR WIN'<
EXITING WATER LNE
w,:R ev;R
"IR01D WATER Lk"
D-- — — -- — — — —®
PROP. STORM SEWR
FIRE HYDRANT
PROP. SIVIiARY SEWER
low
SAN
EX. SAN = UNDERGR(XJND SANfiARY SINER
—aro —ate —
� = OVERTIDAD U11J1Y
— — — —
DC ROX = RW OF WAY (AS NOTED)
— — — —
PROP. R.O.W. = W OF WAY (AS NOTD)
— —
CEN11 W AS NOTED
--- -- - --- --
B.L= HDINCSETBACKX
------------ - - - - --
EAW (AS NOTED)
CONC. CURB (AS NOTED)
DC SPOT DRAIN
X
—
CONTOURS - WEIR INTERVAL
----- - - - - --
CONTOURS - KR INTERVAL
PROPOSED CONTOUR - 1 FOOT INfE k
B. L.
BUONG SETBACK LINE
D.U. &S.E.
DRAW[ W AM SEWER [UP
D.U. &S. S. E.
MJAGE OR AND SANITARY SEWER M
N.A.E. & S.W.E.
NON ACCESS AND SIDEWALK EASEMENT
SYMBOL LEGEND
cD-.)
OVERHEAD UTILITY POLE
MT
WATER METER
FIRE HYDRANT
O
SURVEY MARKER FOUND
®
DRAINAGE INLET
Wv
WATER VALVE
SIGN
O
WELL
GMTR
V V
GAS METER
070700 0-'/J
Approved By: BCR/TJW
Drawn By: TJW
Date of Last Field Work: 06/13/07
Date Plotted: 09/06/07
Reference #:
Project Number:
C7 -1357
Sheet Number:
3 of 3