HomeMy WebLinkAboutThe Bridges - MEP.pdfCODED NOTES: 1.INSTALL FIRE PROTECTION SYSTEM IN VERTICAL, TIGHT TO WALL. 2.DOMESTIC WATER BACKFLOW PREVENTER. 3.2" DOMESTIC WATER UP THRU FLOOR TO MASTER METER. 4.WATER SUB-METER REMOTE READ PANEL LOCATION. 5.GAS METER MANIFOLD FURNISHED & INSTALLED PER LOCAL GAS CO. REQUIREMENTS. TWO (2) METERS PROVIDED FOR TWO (2) FUTURE RESTAURANT-TYPE TENANTS. LOCATION OF METERS SHALL BE VERIFIED WITH LOCAL GAS CO. PRIOR TO ROUGH-IN. SCREEN METERS AS REQUIRED. TOTAL ASSUMED LOAD = 400 MBH (CONTRACTOR TO VERIFY). 6.SPRINKLER RISER WITH WALL P.I.V. AND MOTOR ALARM BELL. 7.6"STORM DOWN THRU SLAB W/WCO @ 18"AFF. 8.MOUNT @18" AFF 6" OVERFLOW STORM DOWN W/ CLEANOUT AT BASE. 9."CW VALVED & CAPPED. FUTURE TENANT TO PROVIDE SUBMETER WITHIN TENANT'S CEILING SPACE. TO BE READ REMOTELY FROM LANDLORD ROOM. SEE BOX NOTE BELOW FOR ADDITIONAL INFO (TYP). 10.4"SAN CAPPED FOR FUTURE USE (TYP) 11.4" VTR. 12.REMOTELY LOCATED FIRE DEPARTMENT CONNECTION LOCATED ON ISLAND. SEE CIVIL DRAWINGS. 13.PROTECT FROM FREEZING. # DR I V E TH R U {TENANT A1 lease area2,000 s.f.} {TENANT A2 lease area 2,400 s.f.} {TENANT A3 lease area 1,760 s.f.} {TENANT A5 lease area 1,840 s.f.} {TENANT A4 lease area 1,551 s.f.} A.1 3.91.1 3.52.51.5 C A B 3 412 %MECHANICAL PLAN 1/8" = 1'-0"N EUH 1 3 KW 4" SANITARY CO FD RAIN CONDUCTORRC INCLUDED IN THIS BID. ALL OTHER TRADES. ALL EQUIPMENT. ORC CW E.C. CO FD REGULATIONS. ALL OWNER'S CRITERIA SHALL BE COMPLIED WITH AND 4. MAINTAIN ALL MANUFACTURER'S RECOMMENDED SERVICE CLEARANCES FOR 3. SPRINKLER CONTRACTOR SHALL COORDINATE SPRINKLER SYSTEM WITH SHALL TAKE ALL INTERFERENCES INTO CONSIDERATION. PROCESS AND FIELD VERIFY EXISTING CONDITIONS. CONTRACTOR 1. MECHANICAL CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING 2. CONTRACTOR SHALL BE FAMILIAR WITH OWNER'S STANDARDS, RULES AND P.C. M.C. G.C. OD TPV RPBP RD WH-1 F.P.C. REDUCED PRESSURE BACKFLOW PREVENTER ELECTRICAL CONTRACTOR FLOOR DRAIN PLUMBING CONTRACTOR GENERAL CONTRACTOR MECHANICAL CONTRACTOR OVERFLOW DRAIN TRAP PRIMER VALVE ROOF DRAIN WALL HYDRANT FIRE PROTECTION CONTRACTOR OVERFLOW CONDUCTOR DIRECTION OF FLOW GAS PIPING DOMESTIC COLD WATER PIPING CHECK VALVE BALANCE VALVE PIPE UNION CLEANOUT SHUTOFF VALVE G SAN SANITARY SEWER PIPING CO4"4"4" 4" CO 2"2"2" G BY OTHERS FORCONTINUATION (TYP) SEE SITE PLAN 3/4" WH-1 M WATER METER NOTE FOR FUTURE TENANTS 9283, X127. GUARDIAN WATER AND POWER, CONTACT JENNIFER DUFFY, 1-800-444- COORDINATE INSTALLATION AND PAYMENT ARRANGEMENTS WITH SUBMETERS. ALL HARDWARE. PLUMBING SUBCONTRACTOR TO INSTALL WATER X127. PLUMBING CONTRACTOR TO PURCHASE WATER SUBMETERS, AND COLUMBUS, OHIO. CONTACT JENNIFER DUFFY, 1-800-444-9283, PURCHASE WATER SUBMETERS FROM GUARDIAN WATER AND POWER IN AND POWER. INSTALL AMCO C700 WATER METERS FURNISHED BY GUARDIAN WATER CONSTRUCTION OF THE SHELL. FUTURE TENANTS SHALL DESIGN FOR A DUCTED RETURN DUE TO THE WOOD 3/4" CW 3/4" CWSAN WH-1 CW 3/4" 4" RD1 (3200 SF) 4" ORD 4" RD1 (3200 SF) 4" ORD 4" RD1 (3200 SF) 4" ORD OD-1 CO4"4" OC 6" RC CO 6"STORM ST 6" RCSAN CWF SAN 1 2 3 4 5 6 7 8 10 9 11 CW CO WH-1 ROOFTOP UNITS. FUTURE TENANTS SHALL DESIGN FOR ELECTRIC HEATING AND COOLING PROVIDE SPLASH BLOCK 12 4" OC OC COCO 13 13 (TYP) (TYP) 5'- 0 " (T Y P ) FROM FREEZING. 5. CONTRACTOR TO PROVIDE TEMPORARY HEAT AS REQUIRED TO PREVENT PIPES 13 ã2011 DORSKY+YUEINTERNATIONALLL C IN T E R N A T I O N A L LLC AR C H I T E C T U R E Th e B R I D G E S CA R M E L , I N (A D D R E S S ) Jo b N o . : D Y 2 0 1 0 2 6 Da t e : DO R S K Y +YU E CL E V E L A N D FO R T L A U D E R D A L E P: 2 1 6 . 4 6 8 . 1 8 5 0 P: 9 5 4 . 7 0 3 . 7 8 3 0 F: 2 1 6 . 4 6 4 . 3 6 1 0 F: 9 5 4 . 5 2 4 . 8 6 0 4 WA S H I N G T O N D . C . P: 2 0 2 . 7 7 6 . 0 4 0 0 F: 2 0 2 . 7 7 6 . 9 3 4 7 Issue: Date: Dr a w n : Ch e c k e d : THORSON BAKER & Associates, Inc. 3030 West Streetsboro Road Richfield, Ohio 44286 (330) 659-6688 Ph.(330) 659-6675 Fax Consulting Engineers Owner Review 2/21/2013 Permit Submittal 3/01/2013 Bid/Construction 3/13/2013 M101 ME C H A N I C A L P L A N TB A Y: \ 2 0 1 3 \ 2 0 1 3 - 0 1 0 2 \ C a d \ M e p \ 2 0 1 3 - 0 1 0 2 M 1 0 1 . d w g , M 1 0 1 , 3 / 1 3 / 2 0 1 3 4 : 2 7 : 3 8 P M , 1 : 1 WALL HYDRANT DETAIL ANCHOR WATER PIPE NTS SHUTOFF VALVE WITH COPPER PLATEDCLAMPS/SUPPORTS WATER PIPING FINISHED EXTERIOR WALL KEY OPERATED VALVE ACCESS DOOR VACUUM BREAKER FINISHED GRADE36 " VERIFY WALL THICKNESS RUN IN JOIST SPACE (TYP.) RUN DOWN INSIDE OF WALL FRAMING (NOT INSIDE TENANT SPACE AS SHOWN) NTS EIGHTH BEND FINISHED FLOORSECURE RIM FLUSH WITH FINISHED FLOOR ADJUSTABLE HOUSING PIPE EXTENSION WYE FITTING SANITARY/STORM PIPING FLOW AS THE PIPE TO WHICH IT IS CONNECTED1. CLEANOUT SHALL BE THE SAME SIZE UP TO 4". FOR PIPES LARGER THAN 4", THE MINIMUM SIZE OF THE CLEANOUT IS 4". GENERAL NOTE: (CAST IRON; FUSED JOINT (PVC) "NO-HUB" CLAMP ASSEMBLY (TYP.) 3 8 WALL POST INDICATOR VALVE 1 FLOW & TAMPER SWITCHES TO BE PROVIDED& INSTALLED BY F.P.C., WIRED BY E.C.@ EACH TENANT SPACE. VERIFY EXACTREQ'MTS PRIOR TO START OF WORK WALL AND TURNED DOWN 45° TO SPLASH SYSTEM DRAIN PIPED THROUGH EXTERIOR ISOLATION CHECK VALVE WITH AUTO BALL DRIP TO FIRE PROTECTION SYSTEM FLOW SWITCH WIRED BY E.C. THREADS TO MATCH LOCAL FIRE INCOMING FIRE PROTECTION WATER SUPPLY WATER MOTOR ALARM BELL REMOTELY LOCATED 2-1/2" x 2-1/2" x 4" FIRE DEPARTMENT SIAMESE CONNECTION WITH 'UL' LISTED ALARM CHECK VALVE PRIOR TO START OF WORK.CONTRACTOR BY HYDRAULIC CALCULATIONSTO BE DETERMINED BY FIRE PROTECTION FIRE PROTECTION WATER SERVICE SIZE INCOMING FIRE PROTECTION SERVICE PIPING DIAGRAM 11 NTS THRUST BLOCK 5 6"* D 10 6 D 4 3 M 2 NOTE: 5 4 6 8 10 11 9 *NOTE: WITH TAMPER SWITCH DEPARTMENTS WITH CAPS AND CHAINS WITH RETARD CHAMBER WITH TAMPER SWITCH ON SHUT OFF VALVESBACKFLOW PREVENTER, AMES NO. 3000SS DOUBLE CHECK DETECTOR ASSEMBLY SLEEVE AND SEAL THRU FLOOR 2 1 9 CODED NOTES: 12 DRAIN TO DRAIN APPROVED LOCATION COATS OF RUST INHIBITIVE PAINT WITH 3/4" PROVIDE DRIP PAN UNDER HORIZONTAL PIPING AND VALVES, 1-1/2" HIGH SIDES WITH WELDED SEAMS, GALV. STEEL WITH 2 FROM SPRINKLER RISER. 12 FUTURE CAPPED FOR LOUVERED DIFFUSER AND CEILING BRACKET #MCMB-10. 1. PROVIDE WITH INTEGRAL THERMOSTAT, DISCONNECT SWITCH, ELECTRICAL DATA (VOLT/PH.) 2. APPROVED EQUALS: MARKEL REMARKS REMARKS: UNIT HEATER MODEL No. CFM MBH TYPE KW MARK MANUFACTURER 208/1 1,2 MUH03-71 350 10.2 CEILING 3 Q MARK EUH-1 INCOMING WATER SERVICE NTS PER LOCAL WATER DEPT'S. REQ'MTS.WATER METER. FURNISH & INSTALL #1, WITH 1/2" DRAIN TO FLOOR DRAIN PLUMBING PRODUCTS, MODEL OREGON TRAP PRIMER VALVE, PRECISION NEW INCOMING WATER SERVICE5 6 7 WATER SERVICE TIGHT TO WALL, NOTE: PROPERLY SUPPORT WITH WALL DURING TENANT OFF HOURS). IRRIGATION WILL RUN ON TIMER BLDG. FOR SITE IRRIGATION. (NOTE: ROUTE THRU WALL TO OUTSIDE OF CODED NOTES: SHUT-OFF VALVE PREVENTER, WATTS No. 909S-QT, 2" 'RPZ' REDUCED PRESSURE BACKFLOW SLEEVE AND SEAL THRU FLOOR PRESSURE REDUCING VALVE, PIPE RELIEF PORT TO FLOOR DRAIN. 3 4 2 1 1 1 1/2" 2 x PIPE DIA. 2" 5 AIR GAP= 7 M 2 1/2" ABOVE FINISHED FLOOR 3"FD 3 FINISHED FLOOR CENTERLINE 18" ABOVE FINISHED FLOOR 3 4 6 CENTERLINE 36" CLAMPS. WITH WELDED SEAMS, GALV. STEEL WITH 2PIPING AND VALVES, 1-1/2" HIGH SIDESPROVIDE DRIP PAN UNDER HORIZONTAL COATS OF RUST INHIBITIVE PAINT WITH 3/4"DRAIN TO FLOOR DRAIN. 8 2 CEILING ROUTE IN JOIST SPACE. SANITARY DIAGRAM PRIMER DRAIN 4" %C O NTS CAPPED FOR FUTUREUSE (TYP) 4"VTR %4 " F D 4" %C O 2" 4" 1/2" TRAP %C O %C O 4" %C O %C O 4" %C O 4" %C O 4" 4" %C O (SHOWN OUT OF PLACE FOR CLARITY) ã2011 DORSKY+YUEINTERNATIONALLL C IN T E R N A T I O N A L LLC AR C H I T E C T U R E Th e B R I D G E S CA R M E L , I N (A D D R E S S ) Jo b N o . : D Y 2 0 1 0 2 6 Da t e : DO R S K Y +YU E CL E V E L A N D FO R T L A U D E R D A L E P: 2 1 6 . 4 6 8 . 1 8 5 0 P: 9 5 4 . 7 0 3 . 7 8 3 0 F: 2 1 6 . 4 6 4 . 3 6 1 0 F: 9 5 4 . 5 2 4 . 8 6 0 4 WA S H I N G T O N D . C . P: 2 0 2 . 7 7 6 . 0 4 0 0 F: 2 0 2 . 7 7 6 . 9 3 4 7 Issue: Date: Dr a w n : Ch e c k e d : THORSON BAKER & Associates, Inc. 3030 West Streetsboro Road Richfield, Ohio 44286 (330) 659-6688 Ph.(330) 659-6675 Fax Consulting Engineers Owner Review 2/21/2013 Permit Submittal 3/01/2013 Bid/Construction 3/13/2013 M201 ME C H A N I C A L D E T A I L S TB A Y: \ 2 0 1 3 \ 2 0 1 3 - 0 1 0 2 \ C a d \ M e p \ 2 0 1 3 - 0 1 0 2 M 2 0 1 . d w g , M 2 0 1 , 3 / 1 3 / 2 0 1 3 4 : 2 7 : 4 7 P M , 1 : 1 SECTION 15010 - GENERAL REQUIREMENTS A. GENERAL 1. SPECIFICATIONS ARE APPLICABLE TO ALL CONTRACTORS AND/OR SUBCONTRACTORS FOR MECHANICAL SYSTEMS. 2. CHECK OTHER PLANS AND SPECIFICATIONS AND FULLY COORDINATE WITH OTHER TRADES, OWNER AND ARCHITECT REQUIREMENTS. 3. CONFORM TO ALL GENERAL AND SPECIAL CONDITIONS OF CONTRACT AS SPECIFIED BY ARCHITECT AND/OR OWNER. 4. VISIT SITE, CHECK FACILITIES AND CONDITIONS AND MAKE ALL NECESSARY OBSERVATIONS AND MEASUREMENTS. NOTE CONDITIONS UNDER WHICH WORK IS TO BE PERFORMED AND TAKE ALL ITEMS INTO CONSIDERATION IN BID. 5. SYSTEMS ARE TO BE COMPLETE AND WORKABLE IN ALL RESPECTS, PLACED IN OPERATION AND PROPERLY ADJUSTED. 6. EACH CONTRACTOR SHALL PROVIDE FOR HIS OWN CLEAN-UP, REMOVAL AND LEGAL DISPOSAL OF ALL RUBBISH DAILY. 7. CONTRACTOR SHALL PROTECT HIS WORK, HIS EXISTING AND ADJACENT PROPERTY AGAINST WEATHER. 8. TO PROTECT HIS WORK, MATERIALS, APPARATUS AND FIXTURES FROM DAMAGE. ANY WORK DAMAGED BY FAILURE TO PROVIDE PROTECTION REQUIRED, SHALL BE REMOVED AND REPLACED WITH NEW MATERIAL AT THE CONTRACTOR'S EXPENSE. 9. CONTRACTOR MUST CONFIRM ALL UTILITY COMPANY REQUIREMENTS AND CONNECTION POINTS IN FIELD, PRIOR TO STARTING WORK. 10. ARRANGE FOR AND OBTAIN OWNER'S AND INSURANCE REPRESENTATIVE'S PERMISSION FOR ANY SERVICE SHUTDOWNS. 11. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, SEQUENCES OF CONSTRUCTION AND THE SAFETY OF WORKMEN. 12. NO PIPING, DUCTWORK, WIRING, ETC., SHALL BE INSTALLED OR ROUTED ABOVE ELECTRICAL PANELS AND EQUIPMENT. 13. THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE ELECTRICAL CONTACTOR AND OBTAIN A WRITTEN APPROVAL IDENTIFYING THE ELECTRICAL CHARACTERISTICS OF ALL MECHANICAL EQUIPMENT PRIOR TO ORDERING OF EQUIPMENT. NO ADDITIONAL PAYMENT WILL BE MADE FOR LACK OF CONTRACTOR COORDINATION OF ELECTRICAL CHARACTERISTICS. 14. DURING CONSTRUCTION THE CONTRACTOR MAY UNCOVER AN EXISTING CONDITION THAT WILL HAVE TO BE MODIFIED. ANY SUCH WORK WHICH COMES UNDER THE JURISDICTION OF THIS CONTRACTOR SHALL BE DONE BY THIS CONTRACTOR WITHOUT EXTRA COST TO THE OWNER, AS THOUGH FULLY DETAILED ON PLANS AND/OR DESCRIBED IN THE SPECIFICATIONS. 15. WORK RELATED TO THE EXISTING BUILDING SHALL BE COORDINATED TO MINIMIZE INTERFERENCE OR INTERRUPTION OF NORMAL BUILDING USE BY OWNER. REFER TO ARCHITECTURAL PLANS FOR PHASING REQUIREMENTS. B. CODES, PERMITS, STANDARDS AND REGULATIONS 1. CONFORM TO ALL APPLICABLE CODES (LOCAL, STATE, NATIONAL CODES, NFPA, OSHA, ETC.), GOVERNMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND APPLICABLE STANDARDS. 2. OBTAIN PERMITS AND PAY ALL FEES. ARRANGE FOR ALL REQUIRED INSPECTIONS AND APPROVALS. C. RELATED WORK SPECIFIED ELSEWHERE 1. OPENINGS AND CHASES, WHEN SHOWN ON ARCHITECTURAL DRAWINGS. 2. TEMPORARY WATER SERVICE, SANITARY FACILITIES, FIRE PROTECTION AND HEATING DURING CONSTRUCTION. 3. POURED-IN-PLACE CONCRETE. 4. FINISHED PAINTING. 5. ELECTRIC POWER WIRING. D. DRAWINGS 1. THE SYSTEMS AS SHOWN ON MECHANICAL DRAWINGS ARE DIAGRAMMATIC. CONFIRM ALL DIMENSIONS BY FIELD MEASUREMENT. 2. THE EXACT LOCATIONS FOR FIXTURES, EQUIPMENT AND PIPING WHICH IS NOT COVERED BY DRAWINGS, SHALL BE OBTAINED FROM THE ARCHITECT OR HIS REPRESENTATIVE IN THE FIELD AND THE WORK SHALL BE LAID OUT ACCORDINGLY. 3. DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT ONE ANOTHER. ANY MATERIALS OR LABOR CALLED FOR IN ONE BUT NOT THE OTHER SHALL BE FURNISHED AS IF BOTH WERE MENTIONED IN THE SPECIFICATIONS AND SHOWN ON THE DRAWINGS. E. BASE EQUIPMENT, MATERIALS AND SUBSTITUTIONS 1. ALL EQUIPMENT AND MATERIALS SHALL BE NEW, FREE OF DEFECTS AND U.L. LABELED. 2. BASE BID MANUFACTURERS ARE INCLUDED IN THE SPECIFICATIONS OR LISTED IN SCHEDULES ON THE DRAWINGS. ALL OTHER MANUFACTURERS ARE CONSIDERED A SUBSTITUTION. 3. THE NAME OR MAKE OF ANY ARTICLE, DEVICE, MATERIAL, FORM OF CONSTRUCTION, FIXTURE, ETC., STATED IN THIS SPECIFICATION, WHETHER OR NOT THE WORDS "OR APPROVED EQUAL" ARE USED, SHALL BE KNOWN AS A "STANDARD". 4. ALL PROPOSALS SHALL BE BASED ON "STANDARDS" SPECIFIED. 5. THE EQUIPMENT SCHEDULES ON THE DRAWINGS INDICATE MANUFACTURERS EQUIPMENT MODEL NUMBERS THAT THIS DESIGN HAS BEEN BASED ON. THE USE OF OTHER MANUFACTURERS EQUIPMENT THAT IS LISTED AS ACCEPTABLE ALTERNATES THAT ENTAILS GENERAL TRADES, STRUCTURAL, MECHANICAL, ELECTRICAL, ETC., REVISIONS IS THIS CONTRACTOR'S RESPONSIBILITY. ANY ADDITIONAL COST OF SUCH CHANGES SHALL BE PAID BY THE CONTRACTOR SUBMITTING THE ACCEPTABLE ALTERNATES WHICH NECESSITATES CHANGES IN INSTALLING SUCH SUBMITTED ALTERNATE EQUIPMENT, EVEN THOUGH SUCH COSTS MAY BE PART OF ANOTHER DIVISION OF WORK. 6. SUBSTITUTIONS ARE SUBJECT TO THE APPROVAL OF THE OWNER. IF A SUBSTITUTION IS SUBMITTED, IT IS THE CONTRACTOR'S RESPONSIBILITY TO EVALUATE IT AND CERTIFY THAT THE SUBSTITUTION IS EQUIVALENT IN ALL RESPECTS TO THE BASE SPECIFICATIONS. 7. IF SUBSTITUTIONS ARE APPROVED, NOTIFY ALL OTHER CONTRACTORS, SUBCONTRACTORS, ETC., AFFECTED BY THE SUBSTITUTION AND FULLY COORDINATE WITH THEM. ANY COSTS RESULTING FROM SUBSTITUTION, WHETHER BY THIS CONTRACTOR OR OTHERS, SHALL BE THE RESPONSIBILITY OF AND FROM SUBSTITUTION, WHETHER BY THIS CONTRACTOR OR OTHERS, SHALL BE THE RESPONSIBILITY OF AND PAID FOR BY THE SUBSTITUTING CONTRACTOR. APPROVED SHOP DRAWINGS DO NOT ABSOLVE THIS CONTRACTOR FROM THIS RESPONSIBILITY. 8. ALL EQUIPMENT SHALL BE INSTALLED IN FULL ACCORDANCE WITH THE MANUFACTURER'S DATA AND INSTALLATION INSTRUCTIONS. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO CHECK AND CONFORM THESE REQUIREMENTS PRIOR TO STARTING WORK. F. WARRANTY 1. FULLY WARRANT ALL MATERIALS, EQUIPMENT AND WORKMANSHIP FOR ONE (1) YEAR FROM DATE OF ACCEPTANCE. 2. EXTEND ALL MANUFACTURER'S WARRANTIES TO OWNER, INCLUDING FIVE YEAR (5) COMPRESSOR AND TEN (10) YEAR HEAT EXCHANGER EXTENDED WARRANTY ON HVAC EQUIPMENT. 3. REPAIR OR REPLACE WITHOUT CHARGE TO THE OWNER ALL ITEMS FOUND DEFECTIVE DURING THE WARRANTY PERIOD. IN THE CASE OF REPLACEMENT OR REPAIR DUE TO FAILURE WITHIN THE WARRANTY PERIOD, THE WARRANTY ON THAT PORTION OF THE WORK SHALL BE EXTENDED FOR A MINIMUM PERIOD OF ONE (1) YEAR FROM THE DATE OF SUCH REPLACEMENT OR REPAIR. G. SHOP DRAWING SUBMITTALS 1. SUBMIT SHOP DRAWINGS FOR MECHANICAL, PLUMBING AND FIRE PROTECTION SYSTEMS, INCLUDING BUT NOT LIMITED TO PLUMBING FIXTURES AND EQUIPMENT WITH ADEQUATE DETAILS AND SCALES TO CLEARLY SHOW CONSTRUCTION. INDICATE THE OPERATING CHARACTERISTICS FOR EACH REQUIRED ITEM. CLEARLY IDENTIFY EACH ITEM ON THE SUBMITTAL AS TO MARK, LOCATION AND USE, USING SAME IDENTIFICATION AS PROVIDED ON THE CONSTRUCTION DOCUMENTS. 2. FIRE PROTECTION DRAWINGS SHALL BE FULLY DIMENSIONED AND COORDINATED BASED ON FIELD VERIFIED BUILDING CLEARANCES AND ARCHITECTURAL CEILING LAYOUTS. INDICATE STRUCTURAL, LIGHTING, DUCTWORK AND PIPING AT ALL CRITICAL LOCATIONS. 3. CONTRACTOR SHALL REVIEW AND INDICATE HIS APPROVAL OF EACH SHOP DRAWING PRIOR TO SUBMITTAL FOR REVIEW. SHOP DRAWINGS WILL NOT BE REVIEWED BY THE ENGINEER UNLESS THE CONTRACTOR'S APPROVAL IS NOTED. DO NOT START WORK OR FABRICATION UNTIL SHOP DRAWINGS HAVE BEEN REVIEWED BY THE ENGINEER AND RETURNED TO THE CONTRACTOR. 4. SUBMITTALS WILL BE REVIEWED ONLY FOR GENERAL COMPLIANCE WITH THE CONTRACT DOCUMENTS AND NOT FOR DIMENSIONS OR QUANTITIES. THE SUBMITTAL REVIEW SHALL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY FOR PURCHASE OF ANY ITEM IN FULL COMPLIANCE WITH THE CONTRACT DOCUMENTS OR ITS COMPLETE AND PROPER INSTALLATION. 5. WHERE SUBMITTALS VARY FROM THE CONTRACT REQUIREMENTS, THE CONTRACTOR SHALL CLEARLY INDICATE ON SUBMITTAL OR ACCOMPANYING DOCUMENTS THE NATURE AND REASON FOR THE VARIATIONS. 6. EACH MANUFACTURER OR HIS REPRESENTATIVE MUST CHECK THE APPLICATION OF HIS EQUIPMENT AND CERTIFY AT TIME OF SHOP DRAWING SUBMITTAL THAT THE EQUIPMENT SPECIFIED HAS BEEN PROPERLY APPLIED AND CAN BE INSTALLED, SERVICED AND MAINTAINED WHERE INDICATED ON THE DRAWINGS. ADVISE ENGINEER IN WRITING WITH SUBMITTAL DRAWINGS OF ANY POTENTIAL PROBLEMS. THE MANUFACTURER SHALL BE RESPONSIBLE FOR ANY CHANGES THAT MIGHT BE NECESSARY BECAUSE OF PHYSICAL CHARACTERISTICS OF EQUIPMENT THAT HAVE NOT BEEN CALLED TO THE ENGINEER'S ATTENTION AT THE TIME OF SUBMITTAL. H. RECORD DRAWINGS 1. EACH CONTRACTOR OR SUBCONTRACTOR SHALL KEEP ONE (1) COMPLETE SET OF THE CONTRACT DRAWINGS ON THE JOB SITE ON WHICH HE SHALL REGULARLY RECORD ANY DEVIATIONS OR CHANGES FROM SUCH CONTRACT DRAWINGS MADE DURING CONSTRUCTION. 2. THESE DRAWINGS SHALL RECORD THE INSTALLED LOCATION OF ALL CONCEALED EQUIPMENT, PIPING, ELECTRIC SERVICE, SEWERS, WASTES, VENTS, DUCTS, CONDUIT, ETC., BY MEASURED DIMENSIONS TO EACH SUCH ITEM FROM COLUMN CENTERLINES OR READILY IDENTIFIABLE AND ACCESSIBLE WALLS OR CORNERS OF THE BUILDING. PLANS ALSO SHALL SHOW INVERT ELEVATION OF SEWERS AND TOP ELEVATION OF ALL OTHER BELOW-GRADE LINES. 3. RECORD DRAWINGS SHALL BE KEPT CLEAN AND UNDAMAGED AND SHALL NOT BE USED FOR ANY PURPOSE OTHER THAN RECORDING DEVIATIONS FROM WORKING DRAWINGS AND EXACT LOCATIONS OF CONCEALED WORK. 4. AFTER THE PROJECT IS COMPLETED, THESE DRAWINGS SHALL BE DELIVERED TO THE ARCHITECT IN GOOD CONDITION, AS A PERMANENT RECORD OF THE INSTALLATION AS ACTUALLY CONSTRUCTED. SECTION 15050 - BASIC MATERIALS AND METHODS A. GENERAL 1. PROVIDE ALL MATERIALS, LABOR, EQUIPMENT, AND ACCESSORIES REQUIRED TO FURNISH AND INSTALL THE MECHANICAL ITEMS IDENTIFIED IN THIS SECTION. 2. THIS SECTION INCLUDES BASIC MECHANICAL MATERIALS AND METHODS TO COMPLEMENT OTHER DIVISION 15 SECTIONS IN THIS SPECIFICATION AND REQUIREMENTS INDICATED ON THE MECHANICAL DRAWINGS. B. EXCAVATION AND BACKFILL 1. PERFORM ALL EXCAVATION AND GRANULAR BACKFILL REQUIRED FOR INSTALLATION OF BELOW-GRADE PIPING. 2. EXCAVATE AS REQUIRED TO INSTALL PIPING AT REQUIRED DEPTH AND PITCH. PIPE TO BE LAID ON SAND BEDDING TO GIVE UNIFORM BEARING ALONG LENGTH OF PIPE (SAND INSIDE BUILDING AND INTERLOCKING AGGREGATE OUTSIDE BUILDING). 3. BACKFILL WITH BEDDING MATERIAL TO A MINIMUM OF TWELVE (12) INCHES ABOVE TOP OF PIPE AND COMPACT. BALANCE OF BACKFILL IN OUTDOOR GRASS AREAS SHALL BE CLEAN EARTH UP TO SIX (6) INCHES ABOVE SURROUNDING GRADES. BACKFILL BELOW FINISHED FLOORS SHALL BE SAND, AND OUTDOORS UNDER PAVING SHALL BE INTERLOCKING AGGREGATE. ALL BACKFILL SHALL BE COMPACTED IN MAXIMUM TWELVE (12) INCH LAYERS. 4. ALL OTHER EXCAVATIONS SHALL BE BACKFILLED WITH CLEAN EARTH, EXCLUDING RUBBISH AND BOULDERS. BACKFILL SHALL BE THOROUGHLY TAMPED AND PUDDLED. FULLY COORDINATE WITH ALL OTHER DISCIPLINES. 5. PATCH FLOOR TO MATCH EXISTING ADJACENT SURFACES. C. SUPPORTS AND HANGERS 1. HANGERS AND SUPPORTS ARE TO BE PROVIDED TO PROPERLY SUPPORT, SECURE AND ALIGN PIPING AND TO MEET FIELD CONDITIONS AND AS MANUFACTURED BY GRINNELL OR MICHIGAN. 2. SPACING TO COMPLY WITH ASHRAE STANDARDS AND LOCAL CODE REQUIREMENTS. D. ESCUTCHEONS 1. FIT ALL PIPE PASSING THROUGH WALLS, FLOORS OR CEILINGS IN FINISHED ROOMS WITH STEEL OR BRASS ESCUTCHEONS. WHERE SURFACE IS TO RECEIVE A PAINT FINISH MAKE ESCUTCHEONS PRIME PAINTED; OTHERWISE MAKE ESCUTCHEONS NICKEL OR CHROME PLATED. WHERE PIPING IS INSULATED, FIT ESCUTCHEONS OUTSIDE INSULATION. E. PIPE IDENTIFICATION 1. IDENTIFY EACH PIPE, VALVE IN EQUIPMENT ROOMS, ABOVE ACCESSIBLE CEILINGS AND IN ACCESSIBLE SHAFTS. 2. COLOR CODE IDENTIFICATION BANDS OR MARKER BACKGROUNDS TO IDENTIFY CONTENTS OF PIPE AND DIRECTION OF FLOW LOCATED NEAR EACH VALVE AND FITTING, ON BOTH SIDES OF PIPE PASSING THROUGH WALLS AND ON LONG RUNS AT NOT OVER 20 FOOT INTERVALS. F. ROOF CURBS (AS MANUFACTURED BY PATE, ROOF PRODUCTS AND SYSTEMS AND THY CURB) 1. CURB SHALL BE 18 GAUGE GALVANIZED STEEL WITH CONTINUOUS WELDED SEAMS, WOOD NAILER, COUNTERFLASHING AND INSULATION. TOP OF CURB SHALL BE A MINIMUM OF 12" ABOVE THE FINISHED ROOF SURFACE. 2. PROVIDE CURB FOR ALL ROOF PENETRATIONS OF DUCTS AND PIPING. 3. ALL CUTTING AND PATCHING OF EXISTING ROOF SHALL BE BY THE OWNER'S ROOFING CONTRACTOR AND PAID FOR BY THE MECHANICAL CONTRACTOR. G. FIRESTOPPING 1. ALL OPENINGS THROUGH FIRE RATED WALLS, FLOORS, AND/OR ROOFS FOR DUCTWORK, PIPING, ETC., SHALL BE FIRE SEALED WITH CALCIUM SALICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS, HILTI FIRESTOP SYSTEMS, OR APPROVED EQUAL TO MAINTAIN THE INTENDED FIRE RATING AND ASSOCIATED `UL' RATINGS. H. CUTTING, PATCHING AND DRILLING 1. ALL CUTTING AND PATCHING OF THE BUILDING CONSTRUCTION REQUIRED FOR THIS WORK SHALL BE BY THIS CONTRACTOR UNLESS SHOWN ON ARCHITECTURAL DRAWINGS AND CONFIRMED AS TO SIZE AND LOCATION PRIOR TO NEW CONSTRUCTION. CUTTING SHALL BE IN A NEAT AND WORKMANLIKE MANNER. 2. NEATLY SAW CUT ALL RECTANGULAR OPENINGS, SET SLEEVE THROUGH OPENING, AND FINISH PATCH OR PROVIDE TRIM FLANGE AROUND OPENING. 3. NEATLY SAW CUT FLOORS AND PATCH FLOOR TO MATCH EXISTING, INCLUDING FLOOR COVERING. 4. CONTRACTOR SHALL FIELD VERIFY SLAB-ON-GRADE OR SUPPORTED FLOOR CONSTRUCTION TYPE PRIOR TO CUTTING. UNDER NO CIRCUMSTANCES SHALL THIS CONTRACTOR CUT A STRUCTURAL FLOOR SLAB, WHETHER ON GRADE OR SUPPORTED, WITHOUT PRIOR WRITTEN APPROVAL FROM THE ARCHITECT. IF FLOOR SLAB INDICATED TO BE CUT ON MECHANICAL PLANS IS FOUND TO BE STRUCTURAL IN NATURE, DO NOT CUT. CONTACT ARCHITECT IMMEDIATELY FOR FURTHER DIRECTIONS. 5. CORE DRILL AND SLEEVE ALL ROUND OPENINGS. 6. DO NOT CUT ANY STRUCTURAL COMPONENTS WITHOUT ARCHITECT'S WRITTEN APPROVAL, INCLUDING, BUT NOT LIMITED TO ROOF JOISTS, COLUMNS, FLOOR JOISTS, BEAMS, GIRDERS, STRUCTURAL FLOOR SLABS, ETC. 7. PATCH AND FINISH TO MATCH ADJACENT AREAS THAT HAVE BEEN CUT, DAMAGED OR MODIFIED AS A RESULT OF THE INSTALLATION OF THE MECHANICAL SYSTEMS. FIRE STOP ALL PENETRATIONS OF FIRE RATED CONSTRUCTION IN A CODE APPROVED MANNER. 8. ALL CONTRACTORS SHALL CONFIRM WITH OWNER, PRIOR TO BID, TIMES AVAILABLE FOR NOISE PRODUCING WORK SUCH AS CUTTING AND CORE DRILLING OF FLOORS, WALLS, ETC., AS WELL AS TIMES FOR WORK WHICH REQUIRES ACCESS INTO ADJOINING TENANT SPACES. INCLUDE ANY PREMIUM TIME IN BID. 9. THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR PRIOR TO CONSTRUCTION. THE MECHANICAL CONTRACTOR SHALL PROVIDE INFORMATION REGARDING OPENINGS IN WALLS, FLOORS, ETC., CONCRETE EQUIPMENT PADS AND FOUNDATIONS TO THE GENERAL CONTRACTOR. IF THE MECHANICAL CONTRACTOR FAILS TO COMPLY WITH THIS REQUEST, OR IF INCORRECT INFORMATION IS GIVEN, THE NECESSARY CUTTING AND PATCHING WILL BE PERFORMED BY THE GENERAL CONTRACTOR, AT THE MECHANICAL CONTRACTOR'S EXPENSE. SECTION 15100 - INSULATION A. GENERAL 1. FURNISH ALL MATERIAL, LABOR AND EQUIPMENT AS REQUIRED TO INSTALL COMPLETE PLUMBING AND HVAC INSULATION AS INDICATED ON MECHANICAL DRAWINGS AND IN THESE SPECIFICATIONS. 2. INSTALL IN FULL ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. B. PLUMBING INSULATION (AS MANUFACTURED BY OWENS CORNING, KNAUF OR SCHULLER) 1. INSULATE ALL ABOVE GRADE COLD WATER PIPING WITH MOLDED FIBERGLASS HAVING AN ALL SERVICE JACKET. A. INSULATION THICKNESS SCHEDULE: 1. LESS THAN (<) 1-1/2" DIAMETER PIPE: 3/4" THICK. 2. 1-1/2"-8" DIAMETER PIPE: 1" THICK. 2. INCLUDE INSULATION OF FITTINGS AND VALVES. KEEP VAPOR BARRIERS INTACT. APPLY TO MANUFACTURER'S RECOMMENDATIONS. SECTION 15200 - PIPING AND VALVES A. GENERAL 1. FURNISH ALL MATERIAL, LABOR, EQUIPMENT, AND ACCESSORIES AS REQUIRED TO INSTALL COMPLETE PLUMBING AND HVAC PIPING SYSTEMS AS INDICATED ON MECHANICAL DRAWINGS AND IN THESE SPECIFICATIONS. 2. INSTALL IN FULL ACCORDANCE WITH LOCAL CODE 2. INSTALL IN FULL ACCORDANCE WITH LOCAL CODE REQUIREMENTS, OTHER SPECIFICATION SECTION REQUIREMENTS AND MANUFACTURER'S RECOMMENDATIONS. B. CONNECTIONS TO EQUIPMENT FURNISHED BY OTHERS 1. PROVIDE VALVED WATER AND/OR GAS CONNECTION FOR EQUIPMENT FURNISHED BY OTHER CONTRACTORS OR OWNER. 2. INCLUDE ACCESSORIES REQUIRED BY CODE, DRAWING OR MANUFACTURER'S INSTRUCTIONS. C. SANITARY AND STORM SEWERS 1. INSTALL SANITARY AND STORM SEWERS, STACKS, VENTS, DRAINS, CLEANOUTS, ETC., AS INDICATED ON THE DRAWINGS. 2. SEWERS TO BE PITCHED A MINIMUM OF 1/4" PER FOOT FOR 3" SIZES AND UNDER AND 1/8" PER FOOT FOR 4" SIZES AND LARGER OR TO GRADES INDICATED ON DRAWINGS. 3. CHANGES IN DIRECTION AND BRANCH CONNECTIONS SHALL BE MADE WITH APPROVED DRAINAGE FITTINGS COMPATIBLE WITH THE PIPING SYSTEM MATERIAL IN WHICH IT IS INSTALLED. 4. ALL FIXTURES AND SANITARY DRAINS SHALL BE VENTED AS INDICATED ON DRAWINGS AND IN ACCORDANCE WITH CODE. 5. VENTS ARE TO BE EXTENDED THROUGH ROOF AS INDICATED ON DRAWINGS AND FLASHED WITH 4 LB. LEAD WITH VENT FLASHING TOP TURNED DOWN TWO (2) INCHES MINIMUM INSIDE PIPE. 6. ROOF DRAINS SHALL BE PROVIDED WITH A FLASHING RING AND A 30" X 30" X 4 LB. LEAD FLASHING PROPERLY FASTENED TO THE FLASHING RING. 7. PVC PIPING SHALL NOT BE INSTALLED UNLESS PERMITTED BY CODE AND SHALL NOT BE INSTALLED IN RETURN AIR PLENUMS. 8. SANITARY/STORM SEWER AND VENT MATERIAL SHALL BE AS FOLLOWS: A. BELOW GRADE STORM AND SANITARY INSIDE BUILDING 1. SERVICE WEIGHT - CAST IRON PIPE ASTM A-74-82 WITH ASTM C-564-70 NEOPRENE COMPRESSION JOINTS OR NO- HUB WITH CLAMPS. 2. PVC-DWV PLASTIC ASTM D-1785 WITH ASTM D-2665 DWV SOLVENT WELD SOCKET FITTINGS. B. ABOVE GRADE SANITARY/STORM SEWER AND VENT MATERIAL SHALL BE AS FOLLOWS: 1. NO-HUB CAST IRON PIPE CISPI 1-301- 78. 2. PVC-DWV PLASTIC ASTM D-1785 WITH ASTM D-2665 DWV SOLVENT WELD SOCKET FITTINGS. 3. SCH. 40 GALVANIZED STEEL PIPE ASTM A-120-83 WITH CAST IRON SCREWED FITTINGS ANSI B-16.22 1983. C. SITE STORM AND SANITARY SEWERS 1. UP TO 15" - PVC PLASTIC ASTM D-3034 SDR 35 WITH ASTM D-3212 GASKET JOINTS. 2. 18" AND OVER - REINFORCED CONCRETE PIPE (RCP) ASTM C 76-83 WITH ASTM C 443-79 RUBBER GASKET JOINTS. D. DOMESTIC WATER PIPING 1. INSTALL DOMESTIC WATER PIPING AS INDICATED ON DRAWINGS. INCLUDE ALL FITTINGS, VALVES, HANGERS, AND OTHER ACCESSORIES INCLUDING WATER METER AND BACKFLOW PREVENTER. EXTEND DOMESTIC WATER PIPING TO ALL FIXTURES AND EQUIPMENT REQUIRED FOR COMPLETE INSTALLATION. 2. INCLUDE UNIONS, OR OTHER DISCONNECT MEANS, STOPS OR VALVES FOR ISOLATION OF FIXTURES AND EQUIPMENT. VALVES TO BE FULLY COMPATIBLE WITH PIPING FOR SERVICE INTENDED AS MANUFACTURED BY NIBCO, CRANE OR MILWAUKEE. INCLUDE HOSE OR DRAIN VALVES AT LOW POINTS WHERE FIXTURES CANNOT BE USED FOR DRAINAGE. 3. INSTALL SHOCK ABSORBERS AT EACH QUICK CLOSING FIXTURE AND WHERE REQUIRED TO PREVENT WATER HAMMER AS MANUFACTURED BY J.R. SMITH, SIOUX CHIEF OF ZURN. 4. HANGERS ON INSULATED PIPE TO BE OUTSIDE OF INSULATION, SIZED ACCORDINGLY AND WITH A SUFFICIENT SADDLE TO PROTECT INSULATION AS MANUFACTURED BY GRINNELL OR MICHIGAN. 5. DOMESTIC WATER PIPING SHALL BE AS FOLLOWS: A. ABOVE GRADE - TYPE "L" HARD COPPER ASTM B 88-832 WITH WROUGHT COPPER FITTINGS ASTM B 16.22 1980 AND NON-LEAD OR ANTIMONY SOLDER JOINTS. B. BELOW GRADE - TYPE "K" SOFT COPPER WITHOUT JOINTS. 6. FLUSH, VENT AND SANITIZE ALL WATER PIPING WITH CHLORINE AS REQUIRED PER AWWA, LOCAL BUILDING DEPARTMENT AND HEALTH DEPARTMENT CODES. 7. DOMESTIC COLD WATER PIPING UNDER CONCRETE FLOOR TO BE COVERED WITH SAND SO THAT PIPING WILL NOT BECOME EMBEDDED IN THE FLOOR SLAB. 8. ALL PIPING UNDER CONCRETE FLOOR SHALL BE TYPE "K" SOFT COPPER, CONTINUOUS. NO SPLICES OR FITTINGS WILL ALLOWED. 9. EXTREME CAUTION MUST BE TAKEN SO THAT NO COPPER PIPING AND INSULATION UNDER CONCRETE FLOORS BECOMES CRUSHED, CUT, SPLIT OR DEFORMED DURING THE POURING OF THE FLOOR SLAB. E. GAS PIPING 1. INSTALL GAS PIPING. 2. INCLUDING METER AND REGULATOR AS INDICATED ON DRAWINGS AND CONNECT TO ALL GAS USING EQUIPMENT. 3. EQUIPMENT CONNECTIONS AT EACH UNIT SHALL INCLUDE GAS COCK, UNION AND DIRT LEG. 4. CONSTRUCT CONCRETE BASE TO BELOW FROST LINE FOR METER INSTALLATION. 5. ALL GAS PIPING SHALL CONFORM TO RECOMMENDED PRACTICE AND REGULATIONS OF THE NFPA, LOCAL GAS CO. AND STATE OF INDIANA CODE. 6. GAS PIPING SHALL BE AS FOLLOWS: A. ABOVE-GRADE INSIDE OR OUTSIDE BUILDING, LOW PRESSURE. 1. SCHEDULE 40 SEAMLESS BLACK STEEL PIPE, BEVELED ENDS. A) 2" AND SMALLER - SCREWED FITTINGS, WROUGHT IRON. B) 2 1/2" AND LARGER - WELDED FITTINGS, BLACK STEEL. B. INSIDE BUILDING, MEDIUM PRESSURE 1. SCHEDULE 40 BLACK STEEL WITH WELDED BLACK STEEL FITTINGS. C. BELOW GRADE OUTSIDE BUILDING, LOW AND MEDIUM PRESSURE GAS SERVICE 1. POLYETHYLENE PLASTIC ASTM D-2513 WITH STAB COUPLINGS OR FUSION WELD JOINTS. D. BELOW GRADE, HIGH PRESSURE SERVICE 60 PSI AND OVER 1. SCHEDULE 40 BLACK STEEL COATED AND WRAPPED WITH WELDED BLACK STEEL FITTINGS. INSTALL CATHODIC PROTECTION ANODE ON SERVICE LINE. E. VALVES SHALL NOT BE LOCATED ABOVE ACCESSIBLE CEILING SPACES, WHETHER OR NOT SUCH SPACES ARE USED AS A PLENUM. F. EXTERIOR EXPOSED BARE STEEL PIPE SHALL BE PAINTED WITH TWO (2) COATS OF RUST INHIBITIVE PAINT. G. ALL WELDING SHALL BE PERFORMED BY STATE CERTIFIED WELDERS. F. FIRE PROTECTION PIPING 1. SEE SECTION 15300, FIRE PROTECTION SYSTEMS. G. FIRESTOPPING 1. SEE SECTION 15050, BASIC MATERIALS AND METHODS. SECTION 15300 - FIRE PROTECTION SYSTEMS A. GENERAL 1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO INSTALL A COMPLETE FIRE PROTECTION SYSTEM FOR PROJECT. B. DESIGN BASIS 1. DESIGN BASIS FOR SYSTEM SHALL BE PER NFPA 13 (LATEST EDITION) AND LOCAL CODE REQUIREMENTS. 2. SYSTEM SHALL BE HYDRAULICALLY CALCULATED AS REQUIRED BY CODE. 3. PIPE SIZES INDICATED ON DRAWING ARE APPROXIMATE AND SHALL BE VERIFIED PER THE CONTRACTORS HYDRAULIC CALCULATIONS. C. DRAWINGS AND CALCULATIONS 1. CONTRACTOR SHALL PREPARE SUBMITTAL DRAWINGS AND HYDRAULIC CALCULATIONS FOR SPACE IN ACCORDANCE WITH OWNER'S INSURANCE COMPANY BUILDING DEPARTMENT, AND LOCAL FIRE AUTHORITY REQUIREMENTS. 2. CONTRACTOR SHALL PERFORM A FLOW TEST DATA ON CITY WATER MAIN AND SUBMIT DATA WITH CALCULATIONS. 3. CONTRACTOR AND DESIGNER SHALL BE STATE CERTIFIED. D. PIPING 1. ALL PIPING SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 13, 14 (LATEST EDITION) AND LOCAL CODE REQUIREMENTS. 2. FIRE PROTECTION PIPING SHALL BE AS FOLLOWS: A. BELOW-GRADE OUTSIDE BUILDING - DUCTILE IRON, CEMENT LINED. CLASS OF PIPE AS DIRECTED BY LOCAL WATER PURVEYOR WITH MECHANICAL OR PUSH-ON TYPE JOINTS. B. INSIDE BUILDING - PIPE AND TUBING SHALL BE STEEL OR COPPER IN ACCORDANCE WITH NFPA REQUIREMENTS. C. PIPING SHALL MATCH EXISTING BUILDING STANDARDS. D. CONTRACTOR SHALL ARRANGE WITH OWNER AND INSURANCE UNDERWRITER PRIOR TO SHUTDOWN OF EXISTING SYSTEMS. E. FLUSH ALL PIPING UPON COMPLETION OF PROJECT AND TEST PER NFPA REQUIREMENTS. F. NO PIPING SHALL BE INSTALLED AT LOCATIONS SUBJECT TO FREEZING. 3. EXCAVATION AND BACKFILL - SEE SECTION 15050, BASIC MATERIALS AND METHODS. E. SPRINKLER HEADS 1. SPRINKLER HEADS SHALL BE U.L. LISTED, MATCH EXISTING BUILDING STANDARDS AND BE MANUFACTURED BY CENTRAL, STAR OR VIKING. 2. SPRINKLER HEADS SHALL BE AS FOLLOWS: A. AREAS WITH EXPOSED STRUCTURE 1. UPRIGHT - ROUGH BRASS. B. AREAS WITH CEILINGS 1. PENDENT - CHROME PLATED WITH MATCHING TWO (2) PIECE, FLUSH ESCUTCHEON. 2. SEMI-RECESSED - CHROME PLATED WITH TWO (2) PIECE ADJUSTABLE ESCUTCHEON. 3. RECESSED - BRASS FINISH WITH OFF- WHITE CEILING COVER PLATE. 4. SIDEWALL - CHROME PLATED WITH OFF- WHITE, TWO (2) PIECE, SEMI-RECESSED ESCUTCHEON. 3. INSTALL RECESSED HEADS WITH WHITE FLUSH MOUNTED COVER PLATE IN SALES AREA. 4. INSTALL HIGHER TEMPERATURE SPRINKLER HEADS WHERE REQUIRED BY CODE OR APPLICATION. 5. SUBMIT SAMPLES OF SPRINKLER HEADS TO ARCHITECT PRIOR TO FABRICATION OF ANY PIPING. 6. INSTALL INSPECTOR'S TEST CONNECTION WITH VALVE AND TERMINATE DRAIN THROUGH EXTERIOR WALL WITH TEST FITTING AND SPLASH BLOCK. F. VALVES 1. INSTALL ALL VALVES AS REQUIRED BY NFPA 13, "UL" OR "FM" LISTED AND AS MANUFACTURED BY GRINNELL, HAMMOND OR MILWAUKEE. 2. ALL SHUT-OFF VALVES SHALL BE FITTED WITH TAMPER SWITCHES BY FIRE PROTECTION CONTRACTOR AND WIRED BY ELECTRICAL CONTRACTOR. TAMPER SWITCHES SHALL BE AS MANUFACTURED BY NOTIFIER, POTTER OR VIKING. 3. INSTALL FLOW SWITCH IN RISER AS MANUFACTURED BY NOTIFIER, POTTER OR VIKING AND WIRED BY ELECTRICAL CONTRACTOR. 4. INSTALL "UL" LISTED ALARM CHECK VALVE WITH ALL REQUIRED TRIM, INCLUDING WATER MOTOR ALARM BELL AND DRAINS AS MANUFACTURED BY CENTRAL STAR OR VIKING. 5. INSTALL WALL MOUNTED INDICATOR VALVE AS MANUFACTURED BY POTTER ROEMER, CROKER OR ELKHART AND APPROVED BY LOCAL AUTHORITIES. 6. INSTALL DOUBLE CHECK DETECTOR ASSEMBLY BACKFLOW PREVENTER, AS REQUIRED BY LOCAL WATER PURVEYOR AND AS MANUFACTURED BY WATTS, ZURN OR CONBRACO. 7. INSTALL CHROME PLATED WALL SIAMESE [STORZ] FIRE DEPARTMENT CONNECTION INCLUDING NAMEPLATE, CAPS AND CHAINS AND CHECK VALVE WITH 3/4" AUTOMATIC BALL DRIP PIPED TO FLOOR DRAIN AS MANUFACTURED BY POTTER ROEMER, CROKER OR ELKHART. G. FIRESTOPPING 1. SEE SECTION 15050, BASIC MATERIALS AND METHODS. SECTION 15400 - PLUMBING FIXTURES AND EQUIPMENT A. GENERAL 1. FURNISH ALL FIXTURES AND EQUIPMENT INDICATED AND SCHEDULED ON DRAWINGS, COMPLETE WITH ALL ACCESSORIES, CONTROLS, ETC., AS REQUIRED. 2. INSTALL IN FULL ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND PLACE IN SATISFACTORY OPERATION. B. WALL HYDRANTS (AS MANUFACTURED BY J.R. SMITH, JOSAM OR ZURN) 1. WH: CONCEALED J.R. SMITH SERIES 5509QT, NON-FREEZE TYPE WITH VACUUM BREAKER, REMOVABLE KEY, 3/4" HOSE THREAD, 3/4" INLET STAINLESS STEEL BOX WITH NICKEL BRONZE FACE AND ADJUSTABLE WALL CLAMP. C. ROOF DRAINS (AS MANUFACTURED BY J.R. SMITH, JOSAM, MIFAB OR ZURN) 1. RD-1: J.R. SMITH SERIES NO. 1015 WITH DECK CLAMP, SUMP RECEIVER AND ALUMINUM DOME. D. FLOOR DRAINS (AS MANUFACTURED BY J.R. SMITH, JOSAM, MIFAB, OR ZURN) 1. FD: (GENERAL SERVICE) J.R. SMITH SERIES 2005 (6" DIAMETER FOR POURED FLOORS, 6" SQUARE FOR FLOORS WITH A STRAIGHT LINE PATTERN), FLAT STRAINER WITH NICKEL BRONZE FINISH, FLASHING CLAMP AND 1/2" TRAP PRIMER CONNECTION. E. CLEANOUTS (AS MANUFACTURED BY J.R. SMITH, JOSAM, MIFAB OR ZURN) 1. CO: FLOOR MOUNTED J.R. SMITH SERIES 4020 (POURED FLOORS OR SERIES 4040 FINISHED FLOOR WITH A STRAIGHT LINE PATTERN) WITH SATIN FINISH BRONZE TOP. 2. WCO: WALL MOUNTED J.R. SMITH SERIES 4402 WITH STAINLESS STEEL ACCESS COVER. F. TRAP PRIMER VALVES (AS MANUFACTURED BY PRECISION PLUMBING PRODUCTS, SIOUX CHIEF OR ZURN) 1. TPV: PRECISION PLUMBING PRODUCTS OREGON NO. 1. PROVIDE DISTRIBUTION UNIT FOR MULTIPLE DRAIN CONNECTIONS. MECHANICAL SPECIFICATIONS ã2011 DORSKY+YUEINTERNATIONALLL C IN T E R N A T I O N A L LLC AR C H I T E C T U R E Th e B R I D G E S CA R M E L , I N (A D D R E S S ) Jo b N o . : D Y 2 0 1 0 2 6 Da t e : DO R S K Y +YU E CL E V E L A N D FO R T L A U D E R D A L E P: 2 1 6 . 4 6 8 . 1 8 5 0 P: 9 5 4 . 7 0 3 . 7 8 3 0 F: 2 1 6 . 4 6 4 . 3 6 1 0 F: 9 5 4 . 5 2 4 . 8 6 0 4 WA S H I N G T O N D . C . P: 2 0 2 . 7 7 6 . 0 4 0 0 F: 2 0 2 . 7 7 6 . 9 3 4 7 Issue: Date: Dr a w n : Ch e c k e d : THORSON BAKER & Associates, Inc. 3030 West Streetsboro Road Richfield, Ohio 44286 (330) 659-6688 Ph.(330) 659-6675 Fax Consulting Engineers Owner Review 2/21/2013 Permit Submittal 3/01/2013 Bid/Construction 3/13/2013 M301 ME C H A N I C A L S P E C I F I C A T I O N S TB A Y: \ 2 0 1 3 \ 2 0 1 3 - 0 1 0 2 \ C a d \ M e p \ 2 0 1 3 - 0 1 0 2 M 3 0 1 . d w g , M 3 0 1 , 3 / 1 3 / 2 0 1 3 4 : 2 7 : 5 6 P M , 1 : 1 DR I V E TH R U {TENANT A1 lease area 2,000 s.f.} {TENANT A2 lease area 2,400 s.f.} {TENANT A3 lease area 1,760 s.f.} {TENANT A5 lease area 1,840 s.f.} {TENANT A4 lease area 1,551 s.f.} A.1 3.91.1 3.52.51.5 C A B 3 412 CODED NOTES: 1.3"C WITH PULLWIRE FOR TELEPHONE TO ACCOMMODATE A MINIMUM OF TEN (10) LINES. 2.VERIFY EXACT LOCATION AND HEIGHT WITH ARCHITECTURAL DRAWINGS FOR ALL LIGHTING FIXTURES. 3.LOCATED ON BACKSIDE OF PARAPET. 4.MAX LINK OF 40 FEET OF "C" TYPE FIXTURES TO SAME CIRCUIT. 5.PROVIDE CIRCUITING TO PUMP AT WATER FEATURE AS REQUIRED. VERIFY LOCATION AND ROUTING METHOD WITH OWNER PRIOR TO BID. TRENCH AND BACKFILL AS NECESSARY. CONNECT TO PANEL LLP. 6.FLOW AND TAMPER SWITCH WIRED BY E.C UNDER L.L. SCOPE. COORDINATE WORK WITH PLUMBING CONTRACTOR. # %ELECTRICAL PLAN 1/8" = 1'-0"N PANEL 'LLP ' SITE LIGHTING PANEL 'SLP' SERVICE METERS AND DISCONNECTS. REFER TO ONE-LINE DIAGRAM ON DWG E201 NEW UTILITY TRANSFORMER. REFER TO ONE-LINE DIAGRAM ON E201. PROVIDE BOLLARDS PER POWER COMPANY REQUIREMENTS. REFER TO CIVIL DRAWINGS FOR EXACT LOCATION. VERIFY WITH POWER COMPANY ALL CIRCUITING, TRENCHING AND BACKFILLING REQUIREMENTS PRIOR TO BID TELEPHONE BOARD 4" CONDUIT W/ PULLSTRING FOR TELEPHONE. VERIFY REQUIREMENTS AND ROUTING WITH TELEPHONE COMPANY. PROVIDE ALL TRENCHING AND BACKFILL. 1 1 %UTILITY ROOM PLAN 1/8" = 1'-0"N s A PRIMARY OF TRANSFORMER BY CIVIL CONTRACTOR LLP-1 EUH 13 KW FS TS LLP-2 LLP-4,6 208V-1Ø INTEGRAL DISC. SW. 2 B B E E E E B B BBBB B B (TYP) D D WP,GFI WP,GFI INTERIOR DESIGN BY FUTURE TENANT INTERIOR DESIGN BY FUTURE TENANT INTERIOR DESIGN BY FUTURE TENANT INTERIOR DESIGN BY FUTURE TENANT INTERIOR DESIGN BY FUTURE TENANT WP,GFIWP,GFIWP,GFIWP,GFI 3 333 WP,GFI 3 WP,GFI WP,GFI C C C C C C C C C C C C C C C C C C C C C CD D D C C C C D 2(TYP)4LLP-5 LLP-3 LLP-7 LLP-9 LLP-11 LLP-13 F F F F F #6 GND PROVIDE BOLLARDS TO POWER COMPANY SPECIFICATIONS (TYP) LLP-8 STUB INTO SPACE AND CAP. REFER TO E201 FOR SIZES STUB INTO SPACE AND CAP. REFER TO E201 FOR SIZES S.A.C.P. 3'-8" +48" 5 6 WP,GFI LLP-14 WP,GFI 3 ã2011 DORSKY+YUEINTERNATIONALLL C IN T E R N A T I O N A L LLC AR C H I T E C T U R E Th e B R I D G E S CA R M E L , I N (A D D R E S S ) Jo b N o . : D Y 2 0 1 0 2 6 Da t e : DO R S K Y +YU E CL E V E L A N D FO R T L A U D E R D A L E P: 2 1 6 . 4 6 8 . 1 8 5 0 P: 9 5 4 . 7 0 3 . 7 8 3 0 F: 2 1 6 . 4 6 4 . 3 6 1 0 F: 9 5 4 . 5 2 4 . 8 6 0 4 WA S H I N G T O N D . C . P: 2 0 2 . 7 7 6 . 0 4 0 0 F: 2 0 2 . 7 7 6 . 9 3 4 7 Issue: Date: Dr a w n : Ch e c k e d : THORSON BAKER & Associates, Inc. 3030 West Streetsboro Road Richfield, Ohio 44286 (330) 659-6688 Ph.(330) 659-6675 Fax Consulting Engineers Owner Review 2/21/2013 Permit Submittal 3/01/2013 Bid/Construction 3/13/2013 E101 EL E C T R I C A L P L A N TB A Y: \ 2 0 1 3 \ 2 0 1 3 - 0 1 0 2 \ C a d \ M e p \ 2 0 1 3 - 0 1 0 2 E 1 0 1 . d w g , E 1 0 1 , 3 / 1 3 / 2 0 1 3 4 : 2 6 : 2 7 P M , 1 : 1 ALL TAPS SHALL BE MADE USING TERMINAL BLOCKS (TYP.) DESCRIPTION MOUNTING: FLUSH SACP PANELBOARD DESIGNATION TOTAL CONNECTED LOAD KVA SUB TOTALS 25 23 29 27 21 19 SPARE SPARE SPARE - - - SPARE SPARE- - 5.6 7.48.6 7.7 - - - 5.6 - PANEL 'SLP' - SPACE SPACE SPACE DESCRIPTION SPECIAL REQUIREMENTS 200 11 17 15 13 9 5 7 0.3 5.6 0.5 5.5 0.2 0.2 0.2 CKTNO. 1 3 0.3 0.1 KVA AMPERE BUS 120/208 200 VOLTS 0.3 5.5 1.4 1.1 TIME CLOCK0.4 5.6 SPARE SPARE EXTERIOR RECPTS 1.7 WIRE SOLID NEUTRAL B 1.6 0.5 A 4 AMPERE MAIN PH.3 C CIRCUIT BREAKER 23.7 KVA 20 22 26 24 30 28 - - - - - - 6 10 8 14 18 16 12 - - 0.9 0.1 0.1 CKT 2 No. 4 KVA LLP SURFACE - X EXTERIOR LTG UTILITY ROOM LTG/ RECPT EXTERIOR RECPTS 0.9 1.5 EUH-1 1.5 PHONE REC 0.2 ONE-LINE DIAGRAM NOTES 1.THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL POWER COMPANY REQUIREMENTS PRIOR TO BIDDING & INCLUDE THE COST OF ALL ASSOCIATED LABOR, MATERIALS, & CHARGES IN HIS BID. 2.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE AVAILABLE FAULT CURRENT WITH THE UTILITY COMPANY PRIOR TO BIDDING AND PROVIDE EQUIPMENT RATED ACCORDINGLY. SUBMIT FAULT CURRENT CALCULATIONS WITH SHOP DRAWING SUBMITTAL. 3.ALL BUSSING SHALL BE COPPER. 4.PROVIDE FULL LENGTH VERTICAL BUSSING IN ALL SWITCHBOARDS, DISTRIBUTION PANELS, & PANELBOARDS. 5.PROVIDE FULL SIZE HORIZONTAL BUSSING IN ALL SWITCHBOARDS. 6.ALL CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE. 7.ALL WALL-MOUNTED EQUIPMENT SHALL BE MOUNTED ON 3/4" FIRE RATED BACKBOARD. 8.ALL FLOOR-MOUNTED EQUIPMENT SHALL BE MOUNTED ON 4" HIGH CONCRETE HOUSEKEEPING PAD. 9.PROVIDE NAMEPLATES PER NAMEPLATE DETAIL. 10.COORDINATE SPACE WITH ALL OTHER TRADES TO MAINTAIN ALL CODE- REQUIRED CLEARANCES. 11.REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 12.THE ELECTRICAL CONTRACTOR SHALL PROVIDE FINAL SETTINGS REQUIRED FOR ALL ADJUSTABLE/ELECTRONIC TYPE CIRCUIT BREAKERS WITH LONGTIME, SHORT TIME, GF, INSTANTANEOUS, ETC. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FINAL COORDINATION STUDY. 13.THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH NEC ARTICLE 110.16 FOR LABELING OF PANELS FOR ARC FLASH HAZARD WARNING AS WELL AS FOLLOWING REQUIRED SAFETY PRECAUTIONS WHEN SERVICING OR MAINTAINING ELECTRICAL EQUIPMENT. PANELBOARD NOTES 1.INDICATES BREAKER SHALL BE "SWD" RATED. 2.INDICATES BREAKER SHALL BE "HACR" RATED. 3.INDICATES BREAKER SHALL BE 30 mA "G.F.I." TYPE. 4.INDICATES BREAKER SHALL BE SHUNT-TRIP TYPE. 5.INDICATES BREAKER TO BE "ARC-FAULT" TYPE. 6.INDICATES BREAKER TO HAVE LOCK-ON CLIP. 7.INDICATES BREAKER TO HAVE LOCK-ON CLIP AND RED MARKING. 8.FUTURE PUMP FOR WATER FEATURE. VERIFY REQUIRED BREAKER SIZE/ POLES AND TYPE WITH MANUFACTURER 9."C-#" INDICATES DESIGNATION OF CONTACTOR CONTROLLING CIRCUIT. SEE CONTACTOR SCHEDULE. 10.ALL BREAKERS SHALL BE 20A/1P, UNLESS NOTED OTHERWISE. "5" "4" "3" "2" "1" "7" "6" UTILITY CONTACT CONTACT:E PHONE: - - - 317-261-5047 RODNEY JOHNSON POWER COMPANY INDIANAPOLIS POWER & LIGHT PANEL "LLP" 208Y/120V-3Ø-4W 200A MCB ELECTRICAL ONE-LINE DIAGRAM UNDERGROUND PRIMARY ELECTRIC SERVICE N.T.S.208/120V-3Ø-4W 200AF 200/3 TO T E N A N T A " J I M M Y J O H N S " M 120/208V-3Ø-4W PAD-MOUNT TRANSFORMER. WIREWAY SIZED PER N.E.C. 400/3 400AF M M 200/3 200AF MAIN SERVICE DISCONNECT DETAIL ON THIS SHEET #4/0 GND - SEE GROUNDING M 200/3 200AF M 400/3 400AF 200/3 200AF 1600/3 1600AFPRIOR TO BIDDING. VERIFY EXACT LOCATION TRANSFORMER PAD BY E.C. TO POWER COMPANY WITH POWER CO. FOR SPECS. VERIFY/ COORDINATE RESPONSIBILITIES. NOTE: VERIFY ALL ELECTRICAL CONNECTION REQUIREMENTS AND RESPONSIBILITIES WITH POWER COMPANY EQUIPMENT GROUND BUS NEUTRAL BUS BONDING JUMPER MAIN SERVICE EQUIPMENT MGB - LOCATED NEXT TO MAIN SERVICE EQUIPMENT. SEE NOTE #1 CONNECTION TO STRUCTURAL STEEL OF BUILDING. SEE NOTE #3 EXOTHERMIC WELD (TYPICAL OF 3) (3) 3/4" COPPER-CLAD 10' LONG GROUND RODS 3/0 COPPER 10' MIN. 3/0 COPPER GROUNDING DETAIL NTS 3/0 COPPER CONNECTION TO METAL WATER SERVICE. SEE NOTE #4 3/0 COPPER 3/0 COPPER 3/0 COPPER NOTES: 1. MGB (MAIN GROUND BAR) SHALL BE ERICO #EGBA14412NN (INCLUDES MOUNTING BRACKET AND INSULATORS) OR EQUAL BY HARGER. USE PRESSURE CONNECTORS (LISTED FOR GROUNDING) TO CONNECT COPPER WIRE TO MGB. 2. TMGB (TELECOMMUNICATION MAIN GROUND BAR) SHALL BE ERICO #TMGB-A14L15PT (INCLUDES MOUNTING BRACKET AND INSULATORS) OR EQUAL BY HARGER. USE PRESSURE CONNECTORS (LISTED FOR GROUNDING) TO CONNECT COPPER WIRE TO TMGB. 3. STRUCTURAL STEEL MUST BE USED AS A GROUNDING ELECTRODE WHERE IT IS EFFECTIVELY GROUNDED PER NEC SECTION 250.52. 4. WHERE A WATER METER OR FILTERING EQUIPMENT IS IN THIS METAL WATER PIPING SYSTEM, IT MUST BE BONDED AROUND TO MAINTAIN CONTINUITY EVEN IF THE WATER METER OR FILTER IS REMOVED PER NEC SECTION 250.52. CONNECTION TO SECOND METAL WATER SERVICE. SEE NOTE #4 3/0 COPPER 2" 4'- 0 " 5'- 0 " BOLLARD DETAIL N.T.S. 8" DIAMETER STANDARD STEEL PIPE FILLED W/CONCRETE - PAINT WITH TWO (2) COATS OF YELLOW PAINT. CEMENT WASH PITCH TOP PAVEMENT 1'-6" DIAMETER CONCRETE BASE 1" 3" STANDARD COLORS: 1.NORMAL POWER - BLACK BACKGROUND, WHITE LETTERS 2.EMERGENCY POWER - RED BACKGROUND, WHITE LETTERING 3.IN ADDITION TO THE FUNCTION NAMEPLATE, PROVIDE NAMEPLATES IDENTIFYING ALL "MAIN SERVICE NAMEPLATE DISCONNECTS" - RED BACKGROUND - WHITE LETTERING NOTE: NAMEPLATES ARE REQUIRED ON ALL SWITCHBOARDS, DISTRIBUTION PANELS, PANEL BOARDS, STARTERS, DISCONNECT SWITCHES, RELAYS AND JUNCTION BOXES GREATER THAN 4 11/16" SQUARE. ALSO PROVIDE NAMEPLATES ON BRANCH SWITCHES OF SWITCHBOARDS AND DISTRIBUTION PANELS. LOCATION OF NAMEPLATE FOR SURFACE MOUNTED PANELS. FOR FLUSH-MOUNTED PANELS, INSTALL NAMEPLATE BEHIND DOOR. ENGRAVED LAMACOID, 5/32" LETTERS, SECURE TO PANEL BOARD COVER WITH ADHESIVE TYPE FASTENER. EQUIPMENT DESIGNATION NAMEPLATE DETAIL N.T.S. TO T E N A N T B TO T E N A N T C TO T E N A N T D TO T E N A N T E ELECTRICAL ONE-LINE DIAGRAM CODED NOTES: 1.(1)-2" C W/ PULLSTRING STUBBED INTO SPACE. REFER TO E101 FOR STUB LOCATION. 2.(4)-#3/0 & (1) 6 GND IN (1)-2"C. 3.(2)-2"C. EACH WITH PULLSTRING. 4.(4)#1/0 & 1#6 GND- 2"C. XX 1 SECONDARY ELECTRIC SERVICE LATERALS COMPLETE BY E.C., INCLUDING TRENCHING & BACKFILL. PROVIDE (4)-4"C. EACH WITH (4)-#600 KCMIL, 1#4/0 GND AND (1)-4"C SPARE. PER LL SCOPE. PANEL "SLP" 208Y/120V-3Ø-4W 150A MLO SITE LIGHTING PANEL2 20/2 LIGHTING FIXTURE SCHEDULE C232MVOLT GEB10IS WATTSTYPE A 64 NO. 2 TYPE 32WT8 LAMPS MANUFACTURER LITHONIA CATALOG NUMBER DESCRIPTION 2-LAMP 32W FLUORESCENT STRIP. CHAIN HUNG AT 12' A.F.F.. 120V OW1132-2QF26 (MVOLT)-XXX B 52 2 26W VISA LIGHTING SCONCE.120V HPMEXL AC W 4 35C16-WITH UNIT ACOLYTELED 120V. PROVIDE WITH 24V DC WET LOCATION REMOTE DRIVER. FUTURE TENANT METERING TO POWER CO. SPECS. (TYP.) FUTURE TENANT SERVICE RATED DISCONNECT SWITCH (TYP.) 3 D 8 -WITH UNIT EXTERIOR LTG EXTERIOR LTG EXTERIOR LTG FUTURE PUMP EXTERIOR SCONCE LTG HPMEXL AC G 2 35ACOLYTELED 120V. PROVIDE WITH 24V DC WET LOCATION REMOTE DRIVER. NOTE: VERIFY BOLLARD REQUIREMENTS WITH POWER COMPANY DESCRIPTION MOUNTING: FLUSH PANELBOARD DESIGNATION TOTAL CONNECTED LOAD KVA SUB TOTALS 25 23 29 27 21 19 - - - SPARE SPARE - - - --- - - - - - - DESCRIPTION SPECIAL REQUIREMENTS 150 11 17 15 13 9 5 7 - SPARE - - - - - - CKTNO. 1 3 - - KVA AMPERE BUS 120/208 150 VOLTS - - - - - - SPARE - WIRE SOLID NEUTRAL B - - A 4 AMPERE MAIN PH.3 C CIRCUIT BREAKER -KVA 20 22 26 24 30 28 - - - - - - 6 10 8 14 18 16 12 - - - - - CKT 2 No. 4 KVA SLP SURFACE - X - - - - SPACESPACE SPARE SPARE SPARE SPARE SPACESPACE SPACESPACE SPACESPACE SPACESPACE SPACESPACE SPACESPACE SPACESPACE SPACESPACE SPACESPACE SPACESPACE EXTERIOR SCONCE LTG 7 4 150/3 60/3 COORDINATE WITH CIVIL DRAWINGS TO GND. SEE DETAIL 2 "8" 8 TC#1 CONTROL TIMECLOCK LLP-12 UNDER CIVIL SCOPE OW1132 (MVOLT) E 52 2 26W VISA LIGHTING SOLID FACED OW1132, 24"H WITH 2-20W MR16 CMH LAMPS WITH INTEGRAL ELECTRONIC BALLASTS.120V CT M CT 3 TRANSFORMER DETAIL NTS ã2011 DORSKY+YUEINTERNATIONALLL C IN T E R N A T I O N A L LLC AR C H I T E C T U R E Th e B R I D G E S CA R M E L , I N (A D D R E S S ) Jo b N o . : D Y 2 0 1 0 2 6 Da t e : DO R S K Y +YU E CL E V E L A N D FO R T L A U D E R D A L E P: 2 1 6 . 4 6 8 . 1 8 5 0 P: 9 5 4 . 7 0 3 . 7 8 3 0 F: 2 1 6 . 4 6 4 . 3 6 1 0 F: 9 5 4 . 5 2 4 . 8 6 0 4 WA S H I N G T O N D . C . P: 2 0 2 . 7 7 6 . 0 4 0 0 F: 2 0 2 . 7 7 6 . 9 3 4 7 Issue: Date: Dr a w n : Ch e c k e d : THORSON BAKER & Associates, Inc. 3030 West Streetsboro Road Richfield, Ohio 44286 (330) 659-6688 Ph.(330) 659-6675 Fax Consulting Engineers Owner Review 2/21/2013 Permit Submittal 3/01/2013 Bid/Construction 3/13/2013 E201 EL E C T R I C A L D E T A L S TB A TB A Y: \ 2 0 1 3 \ 2 0 1 3 - 0 1 0 2 \ C a d \ M e p \ 2 0 1 3 - 0 1 0 2 E 2 0 1 . d w g , E 2 0 1 , 3 / 1 3 / 2 0 1 3 4 : 2 6 : 3 8 P M , 1 : 1 GENERAL NOTES 1.FINAL CONNECTIONS TO LIGHT FIXTURES SHALL BE MADE WITH GREENFIELD FLEXIBLE CONDUIT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE 6'-0". 2.REFER TO ARCHITECTURAL ELEVATIONS FOR EXACT LOCATION OF LIGHT FIXTURES. CONTRACTORS TO COORDINATE LOCATIONS OF LIGHTING, SPEAKERS, AIR DIFFUSERS, GRILLES, SPRINKLER HEADS & THE LIKE, WITH REFLECTED CEILING LAY-OUTS AS REQUIRED & DIRECTED BY THE ARCHITECT. 3.ALL DEVICES, EQUIPMENT, FIXTURES, & THE LIKE, MUST BE GROUNDED BY USE OF A PROPERLY SIZED GROUNDING CONDUCTOR. MECHANICAL/ ELECTRICAL BONDS OF THE METALLIC RACEWAY SYSTEM SHALL ALSO BE MAINTAINED. 4.REFER TO MECHANICAL, PLUMBING, AND FIRE PROTECTION PLANS FOR EXACT LOCATION OF MECHANICAL AND PLUMBING EQUIPMENT. COORDINATE LOCATION OF DISCONNECT SWITCH ASSOCIATED WITH EACH PIECE OF EQUIPMENT WITH RESPECTIVE CONTRACTOR AND INSTALL IN ACCORDANCE WITH THE NEC. 5.REFER TO DIVISION 15 (21, 22 & 23) SPECIFICATIONS, HVAC, PLUMBING AND FIRE PROTECTION PLANS FOR ADDITIONAL ELECTRICAL WORK REQUIREMENTS & COORDINATION. 6.ALL RECEPTACLES SHOWN BACK-TO-BACK IN WALLS SHALL BE SEPARATED HORIZONTALLY BY 8" MINIMUM. 7.WHERE OPEN WIRING METHODS FOR LOW VOLTAGE SYSTEMS ARE PERMITTED BY THE CONTRACT DOCUMENTS AND LOCAL AUTHORITY, THE CONDUCTOR INSULATION MUST BE PLENUM RATED. 8.BRANCH CIRCUIT CONDUCTOR SIZES (& CONDUITS) SHALL BE INCREASED FROM THOSE INDICATED ON THE PLANS TO PREVENT EXCESSIVE VOLTAGE DROP. BRANCH CIRCUITS SHALL BE INSTALLED WITH WIRES OF SUFFICIENT SIZE SO THAT VOLTAGE DROP BETWEEN THE PANEL & THE LOADS DO NOT EXCEED A LIMIT OF 3%. 9.REGARDLESS OF THE TEMPERATURE RATING OF THE CONDUCTOR INSULATION, ALL CONDUCTOR AMPACITY RATINGS FOR THIS PROJECT SHALL BE DETERMINED FROM THE 75°C CONDUCTOR TEMPERATURE RATINGS INDICATED IN THE NEC TABLES. WHERE EQUIPMENT OR DEVICES ARE PROVIDED WITH TERMINALS/LUGS RATED FOR 60°C, THE AMPACITY RATING OF THE 75°C CONDUCTOR SHALL BE LIMITED TO ITS ASSOCIATED 60°C RATING AS INDICATED IN THE NEC TABLES. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO INCREASE THE CONDUCTORS AND CONDUIT SIZE AS REQUIRED. 10.ALL 120V AND 277V BRANCH CIRCUITS SHALL BE PROVIDED WITH SEPARATE NEUTRAL CONDUCTORS. SHARED NEUTRALS WILL NOT BE PERMITTED FOR MULTI-CIRCUIT INSTALLATIONS. WHERE MULTIPLE CIRCUITS ARE RUN IN A COMMON RACEWAY, THE AMPACITY OF THE CONDUCTORS SHALL BE PROPERLY DERATED & CONDUIT SHALL BE SIZED PER CODE. UNDER NO CIRCUMSTANCES SHALL MORE THAN SIX (6) CURRENT CARRYING CONDUCTORS BE RUN IN A SINGLE CONDUIT. REFERENCE NEC ARTICLE AND TABLE 310.15(B)(2)(a). 11.ALL CONDUITS SHALL CONTAIN A GROUND CONDUCTOR SIZED PER NEC TABLE #250.122. IN ADDITION, WHERE AN ISOLATED, INSULATED GROUND IS REQUIRED, A SEPARATE GROUND CONDUCTOR WITH GREEN INSULATION SHALL BE RUN FROM THE PANEL GROUND BUS TO THE ISOLATED GROUND CONNECTION OF THE DEVICE. IN NO CASE SHALL THE SYSTEM GROUND (CONDUCTOR & ASSOCIATED OUTLET BOXES, CONDUIT & BUILDING STEEL) BE ALLOWED TO CONTACT THE ISOLATED GROUND (CONDUCTOR & DEVICE). WHERE CIRCUIT CONDUCTORS ARE INCREASED IN SIZE FOR VOLTAGE DROP, THE GROUND CONDUCTOR SIZE SHALL BE INCREASED PROPORTIONATELY (ACCORDING TO CIRCULAR MIL AREA) FROM THE SIZE REQUIRED BY NEC TABLE #250.122. 12.ELECTRICAL INSTALLATION REQUIREMENTS FOR ALL HVAC, PLUMBING, FIRE PROTECTION, SPECIAL SYSTEMS AND OWNER EQUIPMENT BEING FURNISHED BY OTHERS SHALL BE REVIEWED AND COORDINATED WITH OTHER TRADES PRIOR TO ROUGH-IN. OBTAIN EQUIPMENT SHOP DRAWINGS FROM INSTALLER/SUPPLIER/CONTRACTOR/OWNER FURNISHING EQUIPMENT, AS REQUIRED, FOR REVIEW AND COORDINATION. CONTACT ARCHITECT/ENGINEER WITH ANY DISCREPANCIES FOUND BETWEEN CONSTRUCTION DRAWINGS AND EQUIPMENT BEING FURNISHED PRIOR TO ROUGH-IN. 13.THE ELECTRICAL CONTRACTOR SHALL FURNISH ALL ACCESS PANELS, AS REQUIRED FOR SERVICING AND TESTING, FOR EQUIPMENT AND/OR DEVICES FURNISHED UNDER HIS CONTRACT. THE GENERAL CONTRACTOR SHALL INSTALL ACCESS PANELS. THE ELECTRICAL CONTRACTOR SHALL COORDINATE THE SIZE AND LOCATION OF EACH ACCESS PANEL WITH THE ARCHITECT AND GENERAL CONTRACTOR PRIOR TO ROUGH-IN. 14.ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS BID ALL CUTTING, TRENCHING AND PATCHING ASSOCIATED WITH THE ELECTRICAL INSTALLATION. 15.ALL PENETRATIONS THROUGH FIRE RATED WALLS ASSOCIATED WITH THE ELECTRICAL INSTALLATION SHALL BE SLEEVED AND FIRE-STOPPED USING A UL APPROVED METHOD. UL APPROVED METHOD SHALL MEET OR EXCEED FIRE RATING OF STRUCTURE BEING PENETRATED. REFERENCE ARCHITECTURAL PLANS FOR FIRE RATED STRUCTURES. 16.NO CONDUIT, BOXES, WIRING, OR CABLES SHALL BE INSTALLED WITHIN 1 1/2" OF THE LOWEST POINT OF THE UNDERSIDE OF THE ROOF DECKING, NOR SHALL THEY BE INSTALLED CONCEALED WITHIN METAL-CORRUGATED ROOF DECKING. FOR EXISTING INSTALLATIONS, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO REPLACE AND/OR REWORK EXISTING CONDUIT, BOXES, WIRING, AND CABLING THAT IS NOT IN COMPLIANCE WITH THIS REQUIREMENT. 17.ALL ELECTRICAL EQUIPMENT AND DEVICES FOR THIS PROJECT MUST BE UL LISTED. DEVICES, EQUIPMENT, SYSTEMS SHALL BE INSTALLED PER N.E.C. REQUIREMENTS AND MANUFACTURER'S INSTRUCTIONS. 18.ALL CONDUIT AND CABLING SHALL BE PROPERLY SUPPORTED AS REQUIRED BY THE NATIONAL ELECTRICAL CODE. FOR EXISTING INSTALLATIONS, THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO REPLACE AND/OR REWORK EXISTING CONDUIT AND/OR CABLING THAT IS NOT IN COMPLIANCE WITH THIS REQUIREMENT. MSB TYP. WP X'FMR W UV V UH UNO SPST TS TTB TV PVC SPKR PNL PRE NIC Ø or PH P.C. NL NTS MTD NF NEC HP LTG MFR MOD MCB M.C. MECH. MATV MAU KCMIL K.E.C. KVA INCAND. JB IG F.P.C. GFI HOA GND HID FS G.C. FC FLUOR FPB F FA FACP EWC EWH CT EUH EH EMT EQ. ETR ELEC. EM EF E.C. DWG. (E) or EXIST. EBB DS CU CUH ATS CH CATV CCTV C BKR AWG ARCH. A AFG AHU AIC AFF AC ELECTRICAL ABBREVIATIONS MCC MLO MOUNTED WATTS VOLTS UNLESS NOTED OTHERWISE GAS FIRED UNIT HEATER TELEPHONE TERMINAL BOARD SINGLE POLE SINGLE THROW SPEAKER POWER ROOF EXHAUSTER NOT TO SCALE NIGHTLIGHT NOT IN CONTRACT TRANSFORMER WEATHERPROOF TYPE DEVICE UNIT VENTILATOR TYPICAL TELEVISION TAMPER SWITCH POLYVINYL CHLORIDE PANEL PLUMBING CONTRACTOR PHASE NON FUSED NATIONAL ELECTRIC CODE CABINET UNIT HEATER GROUND FAULT INTERRUPTING MAIN SWITCHBOARD GROUND ISOLATED GROUND KITCHEN EQUIPMENT CONTRACTOR KILOVOLT AMPERE MAKE-UP AIR UNIT MAIN CIRCUIT BREAKER MECHANICAL CONTRACTOR MAIN LUGS ONLY MOTOR OPERATED DAMPER MANUFACTURER MOTOR CONTROL CENTER LIGHTING MASTER ANTENNA TV MECHANICAL HIGH INTENSITY DISCHARGE HAND-OFF-AUTOMATIC HORSEPOWER INCANDESCENT JUNCTION BOX ONE THOUSAND CIRCULAR MILS DRAWING ELECTRICAL ELECTRIC WATER HEATER ELECTRIC BASEBOARD EXISTING EXISTING TO REMAIN FIRE PROTECTION CONTRACTOR GENERAL CONTRACTOR ELECTRIC UNIT HEATER ELECTRIC WATER COOLER FUSE FIRE ALARM FIRE ALARM CONTROL PANEL FAN COIL UNIT FLUORESCENT FAN POWER BOX (VAV) FLOW SWITCH EXHAUST FAN ELECTRIC HEATER EMERGENCY ELECTRICAL METALLIC TUBING EQUAL ELECTRICAL CONTRACTOR DISCONNECT SWITCH COPPER CHILLER CLOSED CIRCUIT TELEVISION CONDUIT ABOVE FINISH GRADE ABOVE FINISH FLOOR AIR CONDITIONING UNIT AMPS COOLING TOWER CONTRACTOR BREAKER AMERICAN WIRE GAGE AUTOMATIC TRANSFER SWITCH ARCHITECTURAL ASYMMETRICAL INTERRUPTING CABLE TELEVISION AIR HANDLING UNIT ------------- ------------ ----------- ----------- ----------- ------------ ---------- ----------- ----------- ----------- ------------- ----------- ----------- ------------ ---------- ------------ ------------ ----------- ------------ ----------- ------ ----------- ----------- ------------ ------------ ---------- ------------ ----------- ------------ ----------- ----------- ----------- ----------- ------------- ------------ ---------- ------------ ---------- ----------- ---------- ------------ ----------- ------------ ----------- ----------- ----------- ------------ ------------ --------- ------------ ---------- ---------- ----------- ----------- ----------- ----------- ----------- ----------- ----------- ---------- ----------- ----------- ----------- ---------------------- ----------- ------------ ------------ ------------ ----------- -------- ----------- ----------- ----------- ----------- ---------- ----------- ------------ ----------- ------------ ----------- ------------ ----------- ------------ ------------- ------------- ------------ ---------- CONTR (NEMA 3R RATED) PROTECTION CURRENT UNDERWRITER'S LABORATORY------------UL ROOF TOP UNIT-----------RTU ------------PB PULL BOX NATIONAL FIRE PROTECTION----------NFPA ASSOCIATION MINIMUM-----------MIN METAL HALIDE------------MH MAXIMUM-----------MAX ------------KW KILOWATT -----------HVAC HEATING, VENTILATION, AIR CONDITIONING HIGH PRESSURE SODIUM-----------HPS FT.------------FOOT/FEET DN DOWN------------ ------------DE DUAL ELEMENT BUILDING----------BLDG. P -------------POLE ----------- AFC ABOVE FINISH COUNTER----------- TIE MULTIPLE OUTLETS WIRED ON------------ SAME BRANCH CICRUIT 20A - 125V GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED 18" AFF, UNLESS CONDUIT WITH WIRING RUN CONCEALED BELOW FLOOR. CROSS HATCHING INDICATES CONDUIT WITH WIRING RUN CONCEALED IN OR ABOVE CEILING OR WALL, OR RUN 20A - 125V ISOLATED GROUND TYPE DUPLEX RECEPTACLE MOUNTED 18" AFF, 20A - 125V GROUNDING TYPE QUADRAPLEX RECEPTACLE MOUNTED 18" AFF, 20A - 120V/277V SINGLE POLE TOGGLE SWITCH MOUNTED 48" AFF, UNLESS HORN/STROBE UNIT MOUNTED 80" AFF TO BOTTOM. TAMPER SWITCH SUPPLIED & INSTALLED BY SPRINKLER CONTRACTOR. FLOW SWITCH SUPPLIED & INSTALLED BY SPRINKLER CONTRACTOR. DISCONNECT SWITCH - TYPE & RATING AS SHOWN ON PLANS PANELBOARD MOUNTED 6'-6" TO TOP. SEE PANEL SCHEDULES & ELECTRICAL ELECTRICAL SYMBOL LEGEND DESCRIPTION JUNCTION BOX - SIZE AS REQUIRED BY NEC SYMBOL IG s F TS FS J EXPOSED IN UNFINISHED AREAS. CROSS HATCHING INDICATES NUMBER OF CONDUCTORS (#12 AWG - MINIMUM). PROVIDE A CODE-SIZED GROUND WIRE IN ALL CONDUITS IN ADDITION TO THE CONDUCTORS SHOWN. SHADED DOT INDICATES CODE-SIZED ISOLATED GROUND WIRE IN CONDUIT. NUMBER OF CONDUCTORS (#12 AWG - MINUMUM). PROVIDE A CODE-SIZED GROUND WIRE IN ALL CONDUITS IN ADDITION TO THE CONDUCTORS SHOWN. SHADED DOT INDICATES CODE-SIZED ISOLATED GROUND WIRE IN CONDUIT. ONE-LINE DIAGRAM. NOTED OTHERWISE (3 = 3 WAY SWITCH / 4 = 4 WAY SWITCH) NOTED OTHERWISE UNLESS NOTED OTHERWISE UNLESS NOTED OTHERWISE FLUORESCENT LIGHT FIXTURE WITH INTEGRAL EMERGENCY BACK-UP LIGHTING BALLAST. NOTE: NOT ALL SYMBOLS MAY APPLY ã2011 DORSKY+YUEINTERNATIONALLL C IN T E R N A T I O N A L LLC AR C H I T E C T U R E Th e B R I D G E S CA R M E L , I N (A D D R E S S ) Jo b N o . : D Y 2 0 1 0 2 6 Da t e : DO R S K Y +YU E CL E V E L A N D FO R T L A U D E R D A L E P: 2 1 6 . 4 6 8 . 1 8 5 0 P: 9 5 4 . 7 0 3 . 7 8 3 0 F: 2 1 6 . 4 6 4 . 3 6 1 0 F: 9 5 4 . 5 2 4 . 8 6 0 4 WA S H I N G T O N D . C . P: 2 0 2 . 7 7 6 . 0 4 0 0 F: 2 0 2 . 7 7 6 . 9 3 4 7 Issue: Date: Dr a w n : Ch e c k e d : THORSON BAKER & Associates, Inc. 3030 West Streetsboro Road Richfield, Ohio 44286 (330) 659-6688 Ph.(330) 659-6675 Fax Consulting Engineers Owner Review 2/21/2013 Permit Submittal 3/01/2013 Bid/Construction 3/13/2013 E202 EL E C T R I C A L D E T A L S TB A TB A Y: \ 2 0 1 3 \ 2 0 1 3 - 0 1 0 2 \ C a d \ M e p \ 2 0 1 3 - 0 1 0 2 E 2 0 2 . d w g , E 2 0 2 , 3 / 1 3 / 2 0 1 3 4 : 2 6 : 4 9 P M , 1 : 1 {Section 16010 - General Provisions}A. {Section 16140 - Wiring Devices} A. ã2011 DORSKY+YUEINTERNATIONALLL C IN T E R N A T I O N A L LLC AR C H I T E C T U R E Th e B R I D G E S CA R M E L , I N (A D D R E S S ) Jo b N o . : D Y 2 0 1 0 2 6 Da t e : DO R S K Y +YU E CL E V E L A N D FO R T L A U D E R D A L E P: 2 1 6 . 4 6 8 . 1 8 5 0 P: 9 5 4 . 7 0 3 . 7 8 3 0 F: 2 1 6 . 4 6 4 . 3 6 1 0 F: 9 5 4 . 5 2 4 . 8 6 0 4 WA S H I N G T O N D . C . P: 2 0 2 . 7 7 6 . 0 4 0 0 F: 2 0 2 . 7 7 6 . 9 3 4 7 Issue: Date: Dr a w n : Ch e c k e d : THORSON BAKER & Associates, Inc. 3030 West Streetsboro Road Richfield, Ohio 44286 (330) 659-6688 Ph.(330) 659-6675 Fax Consulting Engineers Owner Review 2/21/2013 Permit Submittal 3/01/2013 Bid/Construction 3/13/2013 E401 CO M P L I A N C E FO R M S S H E E T TB A TB A Y: \ 2 0 1 3 \ 2 0 1 3 - 0 1 0 2 \ C a d \ M e p \ 2 0 1 3 - 0 1 0 2 E 4 0 1 . d w g , E 4 0 1 , 3 / 1 3 / 2 0 1 3 4 : 2 7 : 1 7 P M , 1 : 1