Loading...
HomeMy WebLinkAbout05060198-Sewer 1his ~ R.H. of Indiana Lot # 86 , containing 7,799 S.F.+ in Section it 1 INSt. ~ Z00500009385 aoy T~, H~t~ ~ty ~ 20. ~ffi, R~ 13671 Stanford Drive (50'R~ Prepared Dote: 05~7/05: B~ AMA Pr~ ~s): Michael ~ Mdisso Miller :+ Residential FF[ - 9,0' = 8osernont F Note,: The g~rege ~Ished floor elewtion is 1.8 obo'~ the curb at the drive, per plan, .S!dewalk to be pieced t , from propert½ line, 4 from bo~ of curb, per plan. Sod Calculations: Dr~ve = 513 SF± Public Walk =244 SF+ Private Walk = 54 SF:I: Hydroseeding --2 541 SF± Sod --32g SY:t:, from Rear of residence. Plot Plan ~ ~rudes 000,0 Existing Grades ~ 000 0--"'" Contour Grade Approx. Lateral Location ~ · ---,-- Sanitary Sewer Lines ~""'"'" Storm Sewer Lnes -- v , Water Service Lines ....... Sub-Surface Drain Lines · Manhole (Sanitary or Storm) O Beehive inlet (StbFm) m Curb inlet (StOrm) D End Section (Storm) J, Fire Hydrant ......... Flow Line of SWale - Building Line (eL / eSL) ....... Easement Line Gte: Soflitary Sewer ~op of Casting information ~pstreom Manhole. TC= g15,20 Downstream Manhole, TC=916.30 per plan, Note: The basement elevation, depicted nereen, has been determined and heeed upon the pad grades and/or contours taken from the construction pons for this subdivision. Unless stated, no information about fTuctuati~g water tobies, soil conditions, or soil t~ee has been provided or stated on said plans, It is recommended that the basement ?ished floor elevations be at least two feet (2) above the normal paul elevation of any edjoning bodies of water, ~nlees a study of facts reveals otherwise, If during the exco~tion process any ground water is witnessed, The Schneider C~porafion should be notified immediately. ~e basement elew~tion should be raised two feet (2) above the ground water eno additional censtructi~ techniques should be incorporated to alleviate ~ture oroniems, 120.00' Note: This drawing is based on construction ~lans or recorc drawings, and is not based uaon a field survey. The Schneider Corporation ages not warrant me accuracy or euffiolenc~ of this information, Contractors should verify existing conditions prior to any construction, Any discrepancy found on this drawing should be reported to l~e Schneider Corporation Jmmediotel~ failing to do so results in the contractors assumption of ail liability. Note: =er Carmel zoning ordinance 26.1.1: ~he rest,dontlal district limits height to twenty-five feet (25), however e dwelling may be ingressed in heght to they-five feet (35') pro,dad the side and rear yorde are increased an additional one foot (1') for each one foot (I'] the structure exceeds the first twenty-five feet (25~) in height. LOt # 86 Dst°, of nd/St ...... ~.........,._~ Water flow p~ttom for VDUb.UU bU di,,ua Assumed No~ Scale: 1" = 30' Note: Sump pump(s) to be pieced by budder as needed. Flood Hazard Statement: The accuracy of an~ flood hazard data shown on this report ts subject map scale uncertainty aha [o any omer uncertain ~, n lOCation or elevat*on on me re erenced flood insurance rate map, ALL of the within described land DOES NOT LIE within the spec a f God hazaro zone A es said land plots by scale on ftood insurance rate mad # 180081 0205F for C ~ o Corms Indiana (maps dated Februa~ 19, 2003L 15' R.D.E. FLOOD HAZARD STATEMENT CERTIFICATION No. g '"% STATE OF ~ '". I ,.'" %.,. · .......... · ~.~